Loading...
HomeMy WebLinkAboutREVISION - Sheet 1 (05-21-2020) EFILEWIDTH PER NOTES DE P T H P E R N O T E S 6 X 6 6 X 6 6 X 6 6 X 6 3. 7 5 PF B 3. 7 5 PF B 3. 7 5 PF B 3. 7 5 PF B 3. 7 5 PF B 3. 7 5 PF B 3. 7 5 PF B 3. 7 5 PF B 3. 7 5 PF B 2X10 SMB CARRY BEAM 2X10 SMB CARRY BEAM 2X10 SMB CARRY BEAM 6X6 6X6 6X6 6X6 6X6 6X6 6X6 HOST GUTTER ATTACHMENT ROOF OVERHANG 2X3 2X3 2 X 3 2X3 2 X 3 2 X 3 2 X 3 2X3 2X3 2X3 2 X 3 2X3 2 X 3 2 X 3 2X 1 0 S M B 2X 1 0 S M B 2X 1 0 S M B 2X 1 0 S M B 2X 1 0 S M B 2X 1 0 S M B 2X 1 0 S M B 2X 1 0 S M B 2X 1 0 S M B 2X2 TYPICAL FOR ALL PURLINS 2X 3 K B 2X 3 K B 2X 3 K B 2X 3 K B 2X 3 K B 2X 3 K B 2X 3 K B 2X 3 K B 2X 3 K B 2X 3 K B 2X 3 K B 2X 3 K B 2X 3 K B 2X 3 K B 3. 7 5 PF B 3. 7 5 PF B 3. 7 5 PF B 3. 7 5 PF B 3. 7 5 PF B 3. 7 5 PF B 3. 7 5 PF B 3. 7 5 PF B 3. 7 5 PF B1X21X21X21X21X21X21X21X21X2 1X2 2X3 TRANSOM WALL ON GUTTER 1X2 2 X 2 1 X 2 ( T Y P ) 2 X 8 S M B C A R R Y B E A M 2 X 8 S M B C A R R Y B E A M 2 X 8 S M B C A R R Y B E A M 2X 8 S M B C A R R Y B E A M 2X 8 S M B C A R R Y B E A M 2X 8 S M B C A R R Y B E A M 1 X2 ( T Y P ) 1X2 2 X2 2X2 DJ 2X2 DJ2X 2 D J 6X6 2 X 4 2 X 4 2 X 4 2 X 4 2 X 4 2 X 4 2X4 2X4 2X4 M-1 2 DJ-1 2 B-1 2 BR-1 2 B-3 3 RC-7 3 RC-4 3 BR-3 2 RC-2 2 TW-2 3 RC-5 3 2X 4 2X 4 2X 4 2X 4 2X4 2X4 2X4 B-4 3 2X4 2X4 2X4 Design Parameters 1.Building Occupancy Category, Paragraph 1604.5 and Table 1604.5: Risk Category I. 2.Basic Wind Speed, Table 1609C, State of Florida Debris Region & Basic Wind Speed, Paragraph 1609.3.1 and Table 1609.3.1 Equivalent Basic Wind Speed, VULT = 150 MPH 3.Exposure Category, Paragraph 1609.4.3 : C Applicable Codes, Regulation and Standards 1.The 6th Edition (2017) Florida Building Code, specifically Chapter 16 Structural Design, Chapter 20 Aluminum, and Chapter 23 Wood. 2.AA ASM 35 and Specifications for Aluminum Structure, Part 1-A of the Aluminum Design Manual prepared by The Aluminum Association, Inc. Washington, D.C., 2010 Edition 3.ASCE 7-10 General Notes 1.The contractor shall verify all dimensions prior to construction 2.All work shall comply with all local and regional ordinances. 3.Any deviation from this plan shall be reviewed by the engineer of record and is subject to approval. Specifications The following specifications are applicable to this projects : 1.Where concrete specification are required, whether in the screen enclosure scope or not, by one or more regulatory agency, the following specifications are applicable. 1.1.Concrete shall conform to ASTM C94 for following components: 1.1.1.Portland Cement Type 1, -ASTM C 150 1.1.2.Aggregate - Large Aggregate 3/4" max - ASTM C 33 1.1.3.Air entraining +/- 1% - ASTM C 260 1.1.4.Water reducing agent - ASTM C 494 1.1.5.Clean Potable water 1.1.6.Other admixture not permitted 1.2.Metal accessories shall conform to: 1.2.1.Reinforcing Bars - ASTM A615, grade 60 1.2.2.Welded wire fabric - ASTM A185 1.3.Concrete slump at discharge per chute not less then 3" or more than 5". Water added after batching is not permitted. 1.4.Prepare and place concrete per American Concrete Institute Manual of Standard Practice, Parts 1, 2 and 3 including hot weather recommendations. 1.5.Moist cure or polyethylene curing required. 1.6.Prior to placing concrete, treat the entire subsurface area for termites in compliance with the FBC. 1.7.All aluminum components embedded within concrete shall be coated with a bituminous paint or epoxy. 1.8.Fiber reinforced concrete per ASTSM C1116 is an acceptable alternative to 6X6 W1.4/W1.4 WWF. 2.Aluminum extrusions shall be 6005 T5 Alloy. 3.Fasteners are required to be corrosion resistant, minimum SAE Grade 2 or better zinc plate to ASTM B633, or stainless steel series "300". 4.All Self Mating Beam Sections are to be stitched with either #14 screws 6" from end 24" on center or #12 screws 6" from end 12" on center. 5.Screened enclosures containing swimming pools shall comply with the applicable requirements of FBC R4501.17 and FBC 454.1.3.1.9. 6.Door location shall be determined by contractor in the field. 7.When installing pavers over concrete slab or footing which are supporting aluminum members, such as continuous screen tracks or upright, the anchors must extend past the pavers and reach proper embedment into the underlying foundation. 8.All flashing and waterproofing shall be provided by the contractor. 9.Use of these plans acknowledges and accepts a limit of liability not to exceed design and engineering fee. 10.Vinyl and acrylic panels shall be removed when wind speeds exceed 75mph Roof Type Full Mansard Screen Size 18/14 Foundation Design: New 12"x12" (2 #5 bar Cont.)(Sides)/ 16"x16" (Back) Ribbon Footing Concrete shall be a minimum 2,500 psi. Rebar 31" lap splice. Use 3" chairs. Per current edition of the FBC R401.4.1 or FBC 1806.2, soils testing is not required for design using the presumptive bearing pressure of 1,500 psf. ALUMINUM MEMBER DIMENSIONS 2 x 2: 2" x 2" x 0.046" 2 x 3: 2" x 3" x 0.050" 2 x 4: 2" x 4" x 0.050" 2 x 5: 2" x 5" x 0.050" HOLLOW SECTIONS 1 x 2: 1" x 2" x 0.040" 1 x 3: 1" x 3" x 0.045" OPEN BACK SECTIONS 2 x 2 Snap: 2" x 2" x 0.045" 2 x 3 Snap: 2" x 3" x 0.050" 2 x 4 Snap: 2" x 4" x 0.045" SNAP SECTIONS 2 x 4 SMB: 2" x 4" x 0.044" x 0.100" 2 x 5 SMB: 2" x 5" x 0.050" x 0.100" 2 x 6 SMB: 2" x 6" x 0.050" x 0.120" 2 x 7 SMB: 2" x 7" x 0.057" x 0.120" 2 x 8 SMB: 2" x 8" x 0.072" x 0.124" 2 x 9 SMB: 2" x 9" x 0.072" x 0.124" 2 x 10 SMB: 2" x 10"x0.092" x 0.398" SELF MATING BEAM (SMB) MINIMUM FASTENER EDGE DISTANCE : 1/2" MINIMUM FASTENER SPACING : 3/4" SIMPSON TITEN HD OR EQUIVALENT CONCRETE SCREW ANCHOR : ITW BUILDEX OR EQUIVALENT SHEET MATEL SCREWS (SMS) : 3.75 PFB: 2" x 3.75" x 0.050" 5.75 PFB: 2" x 5.75" x 0.055" THE PORCH FACTORY BEAM (PFB) KB: KNEE BRACE 3 x 3: 3" x 3" x 0.125" 4 x 4: 4" x 4" x 0.125" 6 x 6: 6" x 6" x 0.125" COLUMNS RC: REC. CHANNEL SHEET SE A S I D E E N G I N E E R S Ce r t i f i c a t e o f A u t h o r i z a t i o n 3 2 0 4 8 42 6 5 6 0 t h C o u r t Ve r o B e a c h , F l o r i d a 3 2 9 6 7 ww w . s e a s i d e e n g i n e e r s . c o m - ( 7 7 2 ) 2 0 2 - 8 0 0 8 - i n f o @ s e a s i d e e n g i n e e r s . c o m Pr o j e c t A d d r e s s : RK D a v i s C o n s t r u c t i o n - M i s s i o n a r y F l i g h t s 31 6 3 H a m m o n d R d Fo r t P i e r c e , F l o r i d a 3 49 4 6 Th e P o r c h F a c t o r y Ed w a r d R o s k e PE # 7 2 2 2 8 1 NOTE: THIS DRAWING IS FOR ILLUSTRATIVE PURPOSES. DRAWING NOT TO SCALE. USE DIMENSIONS GIVEN. CABLE BRACING MAY TERMINATE AT SLAB IN DIFFERENT LOCATION. MAINTAIN ANGLE PER DETAIL. 0 5 / 2 1 / 2 0