HomeMy WebLinkAboutNOA TILE BEL-AIR
NOA No.:16-0314.06
Expiration Date: 10/05/21
Approval Date: 06/16/16
Page 1 of 9
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
Eagle Roofing Products LLC
1575 East C.R. 470
Sumterville, FL 33585
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER -Product Control Section to be
used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(in Miami-Dade County) and/or the AHJ (in areas other than Miami-Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Bel Air, Bel Air Double Eagle, Ponderosa, Ponderosa Double Eagle, Golden Eagle
Low Profile Concrete Tiles
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No.15-0223.18 and consists of pages 1 through 9.
The submitted documentation was reviewed by Gaspar J Rodriguez.
NOA No.:16-0314.06
Expiration Date: 10/05/21
Approval Date: 06/16/16
Page 2 of 9
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub Category: Roofing Tiles
Material: Concrete
1. SCOPE:
This approves a new roofing system using “Low Profile Concrete Tile” as manufactured by Eagle Roofing
Products LLC in Sumterville, FL and described in Section 2 of this Notice of Acceptance. For use in
locations where the pressure requirements, as determined by applicable Building Code, do not exceed the
design pressure values obtained by calculations in compliance with RAS 127 using the values listed in
section 4 herein. The attachment calculations shall be done as a moment based system.
2. PRODUCT DESCRIPTION:
Manufactured by
Applicant
Dimensions
Test
Specifications
Product
Description
Bel Air
Concrete Tile
Lenght = 17"
Width = 12 ¼"
Thickness = ½"
TAS 112
Type 3a
Class III
Flat profile concrete roof tile equipped with two
nail holes. For adhesive set, direct deck or
battened nail-on applications.
Bel Air Double Eagle
Concrete Tile
Lenght = 17"
Width = 12 ¼"
Thickness = ½"
TAS 112
Type 3a
Class III
Flat profile concrete roof tile equipped with two
nail holes. For adhesive set, direct deck or
battened nail-on applications.
Ponderosa
Concrete Tile
Lenght = 17"
Width = 12 ¼"
Thickness = ½"
TAS 112
Type 3a
Class III
Flat profile concrete roof tile with slate finish
equipped with two nail holes. For adhesive set,
direct deck or battened nail-on applications.
Ponderosa Double Eagle
Concrete Tile
Lenght = 17"
Width = 12 ¼"
Thickness = ½"
TAS 112
Type 3a
Class III
Flat profile concrete roof tile with shake finish
equipped with two nail holes. For adhesive set,
direct deck or battened nail-on applications.
Golden Eagle
Concrete Tile
Lenght = 17"
Width = 12 ¼"
Thickness = ½"
TAS 112
Type 3a
Class III
Flat profile concrete roof tile brushed finish
equipped with two nail holes. For adhesive set,
direct deck or battened nail-on applications.
Trim Pieces Lenght = varies
Width = varies
varying thickness
TAS 112 Accessory trim, clay roof pieces for use at hips,
rakes, ridges and valley terminations.
Manufactured for each tile profile.
NOA No.:16-0314.06
Expiration Date: 10/05/21
Approval Date: 06/16/16
Page 3 of 9
2.1 EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Report Date
PRI Asphalt Technologies ERPF-001-02-01 TAS 112 Aug. 2006
Redland Technologies 7161-03
Appendix III
Static Uplift Testing
TAS 102
Dec. 1991
Redland Technologies 7161-03
Appendix III
Static Uplift Testing
TAS 102(A)
Dec. 1991
Redland Technologies 7161-03
Appendix II
Wind Tunnel Testing
TAS 108 (Nail-On)
Dec. 1991
Redland Technologies P0402 Withdrawal Resistance Testing of screw vs.
smooth shank nails
Sept. 1993
Redland Technologies Letter Dated Aug. 1,
1994
Wind Tunnel Testing
TAS 108 (Nail-On)
Aug. 1994
Redland Technologies P09647-01 Wind Tunnel Testing
TAS 108 (Mortar Set)
Aug. 1994
The Center for Applied
Engineering, Inc.
94-084 Static Uplift Testing
TAS 101 (Mortar Set)
May 1994
The Center for Applied
Engineering, Inc.
25-7094-(2, 5, & 8) Static Uplift Testing
TAS 102
Oct. 1994
The Center for Applied
Engineering, Inc.
25-7183-(5 thru 6) Static Uplift Testing
TAS 102
Feb. 1995
The Center for Applied
Engineering, Inc.
25-7214-(1, 5 , & 8) Static Uplift Testing
TAS 102
March, 1995
The Center for Applied
Engineering, Inc.
25-7487-2 Static Uplift Testing
TAS 102
Dec. 1995
The Center for Applied
Engineering, Inc.
25-7496-(1 & 4) Static Uplift Testing
TAS 102
Dec. 1995
The Center for Applied
Engineering, Inc.
25-7804-6 Static Uplift Testing
TAS 102
Sep. 1996
Celotex Corporation Testing
Service
520109-1
520111-4
Static Uplift Testing
TAS 101
Dec. 1998
Celotex Corporation Testing
Service
520191-1
Static Uplift Testing
TAS 101
March 1999
Walker Engineering, Inc. Calculations Aerodynamic Multiplier Sep. 2006
Walker Engineering, Inc. Calculations Restoring Moments Due to Gravity Sep. 2006
ATL of South Florida RT1214.01-15 TAS-112 12/17/15
NOA No.:16-0314.06
Expiration Date: 10/05/21
Approval Date: 06/16/16
Page 4 of 9
3 LIMITATIONS:
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 shall be
required, refer to applicable Building Code.
3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform quarterly test in
accordance with TAS 112, appendix ‘A’. Such testing shall be submitted to the Miami-Dade County Product
Control Section for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable Building Code.
4 INSTALLATION:
4.1 Eagle Roofing Products LLC Bel Air, Bel Air Double Eagle, Ponderosa, Golden Eagle, Ponderosa Double Eagle
Flat Concrete Roof Tiles and its components shall be installed in strict compliance with Roofing Application
Standard RAS 118, RAS 119 and RAS 120.
4.2 Data For Attachment Calculations
Table 1: Average Weight (W) and Dimensions (l x w )
Tile Profile
Weight-W (lbf) Length-l (ft) Width-w (ft)
Bel Air, Bel Air Double Eagle, Ponderosa, Golden
Eagle, Ponderosa Double Eagle Flat Tile
11.4 1.42 1.03
Table 2: Aerodynamic Multipliers - λ (ft3)
Tile Profile
λ (ft3)
Batten Application
λ (ft3)
Direct Deck Application
Bel Air, Bel Air Double Eagle, Ponderosa, Golden
Eagle, Ponderosa Double Eagle Flat Tile
0.301 0.278
Table 3: Restoring Moments due to Gravity - Mg (ft-lbf)
Tile
Profile
3":12" 4":12" 5":12" 6":12" Greater than
7":12"
Bel Air, Bel Air
Double Eagle,
Ponderosa,
Golden Eagle,
Ponderosa
Double Eagle Flat
Tile
Battens Direct
Deck
Battens Direct
Deck
Battens Direct
Deck
Battens Direct
Deck
Battens Direct
Deck
7.48 7.71 7.37 7.59 7.22 7.44 7.05 7.27 6.86 7.07
NOA No.:16-0314.06
Expiration Date: 10/05/21
Approval Date: 06/16/16
Page 5 of 9
Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf)
for Nail-On Systems
Tile
Profile
Fastener Type Direct Deck
(min 15/32” plywood)
Direct Deck
(min. 19/32” plywood)
Battens
Bel Air, Bel
Air Double
Eagle,
Ponderosa,
Golden
Eagle,
Ponderosa
Double
Eagle Flat
Tile
2-10d Ring Shank Nails 30.9 38.1 17.2
1-10d Smooth or Screw
Shank Nail
7.3 9.8 4.9
2-10d Smooth or Screw
Shank Nails
14.0 18.8 7.4
1 #8 Screw 30.8 30.8 18.2
2 #8 Screw 51.7 51.7 24.4
1-10d Smooth or Screw
Shank Nail (Field Clip)
24.3 24.3 24.2
1-10d Smooth or Screw
Shank Nail (Eave Clip)
19.0 19.0 22.1
2-10d Smooth or Screw
Shank Nails (Field Clip)
35.5 35.5 34.8
2-10d Smooth or Screw
Shank Nails (Eave Clip)
31.9 31.9 32.2
2-10d Ring Shank Nails1 50.3 65.5 48.3
1. Installation with a 4" tile headlap and fasteners are located a min. of 2½“ from head of tile.
Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf)
for Two Patty Adhesive Set Systems
Tile Profile
Tile Application Attachment Resistance
Bel Air, Bel Air Double Eagle, Ponderosa, Golden
Eagle, Ponderosa Double Eagle Flat Tile
Adhesive1 31.32
1 See manufactures component approval for installation requirements.
2 The Dow Chemical Company TileBond Average weight per patty 13.9 grams.
ICP Adhesives Polyset® AH-160 Average weight per patty 8 grams.
Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf)
for Single Patty Adhesive Set Systems
Tile Profile Tile Application Attachment Resistance
Bel Air, Bel Air Double Eagle, Ponderosa, Golden
Eagle, Ponderosa Double Eagle Flat Tile
ICP Adhesives Polyset® AH-160 118.93
ICP Adhesives Polyset® AH-160 40.44
3 Large paddy placement of 45 grams of PolyPro™.
4 Medium paddy placement of 24 grams of PolyPro™.
Table 7: Attachment Resistance Expressed as a Moment - Mf (ft-lbf)
for Mortar Set Systems
Tile Profile Tile Application Attachment Resistance
Bel Air, Bel Air Double Eagle, Ponderosa, Golden Eagle,
Ponderosa Double Eagle Flat Tile
Mortar Set5 43.9
5 Tile-Tite Roof Tile Mortar.
NOA No.:16-0314.06
Expiration Date: 10/05/21
Approval Date: 06/16/16
Page 6 of 9
5. LABELING :
All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo (See
Detail Below), or following statement: "Miami-Dade County Product Control Approved".
(LOCATED ON UNDERSIDE OF TILE)
OR
EAGLE FL
(LOCATED ON FRONTSIDE OF TILE)
BEL AIR, BEL AIR DOUBLE EAGLE, PONDEROSA, GOLDEN EAGLE, PONDEROSA DOUBLE EAGLE
CONCRETE ROOF TILE LABEL, SUMTERVILLE PLANT
6. BUILDING PERMIT REQUIREMENTS:
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by AHJ or applicable Building Code in order to properly evaluate the
installation of this system.
NOA No.:16-0314.06
Expiration Date: 10/05/21
Approval Date: 06/16/16
Page 7 of 9
PROFILE DRAWING
BEL AIR
BEL AIR DOUBLE EAGLE
NOA No.:16-0314.06
Expiration Date: 10/05/21
Approval Date: 06/16/16
Page 8 of 9
PONDEROSA
PONDEROSA DOUBLE EAGLE
NOA No.:16-0314.06
Expiration Date: 10/05/21
Approval Date: 06/16/16
Page 9 of 9
GOLDEN EAGLE
END OF THIS ACCEPTANCE