HomeMy WebLinkAboutNOA TILE BEL-AIR NOA No.:16-0314.06 Expiration Date: 10/05/21 Approval Date: 06/16/16 Page 1 of 9 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy Eagle Roofing Products LLC 1575 East C.R. 470 Sumterville, FL 33585 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER -Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (in Miami-Dade County) and/or the AHJ (in areas other than Miami-Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Bel Air, Bel Air Double Eagle, Ponderosa, Ponderosa Double Eagle, Golden Eagle Low Profile Concrete Tiles LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No.15-0223.18 and consists of pages 1 through 9. The submitted documentation was reviewed by Gaspar J Rodriguez. NOA No.:16-0314.06 Expiration Date: 10/05/21 Approval Date: 06/16/16 Page 2 of 9 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub Category: Roofing Tiles Material: Concrete 1. SCOPE: This approves a new roofing system using “Low Profile Concrete Tile” as manufactured by Eagle Roofing Products LLC in Sumterville, FL and described in Section 2 of this Notice of Acceptance. For use in locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION: Manufactured by Applicant Dimensions Test Specifications Product Description Bel Air Concrete Tile Lenght = 17" Width = 12 ¼" Thickness = ½" TAS 112 Type 3a Class III Flat profile concrete roof tile equipped with two nail holes. For adhesive set, direct deck or battened nail-on applications. Bel Air Double Eagle Concrete Tile Lenght = 17" Width = 12 ¼" Thickness = ½" TAS 112 Type 3a Class III Flat profile concrete roof tile equipped with two nail holes. For adhesive set, direct deck or battened nail-on applications. Ponderosa Concrete Tile Lenght = 17" Width = 12 ¼" Thickness = ½" TAS 112 Type 3a Class III Flat profile concrete roof tile with slate finish equipped with two nail holes. For adhesive set, direct deck or battened nail-on applications. Ponderosa Double Eagle Concrete Tile Lenght = 17" Width = 12 ¼" Thickness = ½" TAS 112 Type 3a Class III Flat profile concrete roof tile with shake finish equipped with two nail holes. For adhesive set, direct deck or battened nail-on applications. Golden Eagle Concrete Tile Lenght = 17" Width = 12 ¼" Thickness = ½" TAS 112 Type 3a Class III Flat profile concrete roof tile brushed finish equipped with two nail holes. For adhesive set, direct deck or battened nail-on applications. Trim Pieces Lenght = varies Width = varies varying thickness TAS 112 Accessory trim, clay roof pieces for use at hips, rakes, ridges and valley terminations. Manufactured for each tile profile. NOA No.:16-0314.06 Expiration Date: 10/05/21 Approval Date: 06/16/16 Page 3 of 9 2.1 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date PRI Asphalt Technologies ERPF-001-02-01 TAS 112 Aug. 2006 Redland Technologies 7161-03 Appendix III Static Uplift Testing TAS 102 Dec. 1991 Redland Technologies 7161-03 Appendix III Static Uplift Testing TAS 102(A) Dec. 1991 Redland Technologies 7161-03 Appendix II Wind Tunnel Testing TAS 108 (Nail-On) Dec. 1991 Redland Technologies P0402 Withdrawal Resistance Testing of screw vs. smooth shank nails Sept. 1993 Redland Technologies Letter Dated Aug. 1, 1994 Wind Tunnel Testing TAS 108 (Nail-On) Aug. 1994 Redland Technologies P09647-01 Wind Tunnel Testing TAS 108 (Mortar Set) Aug. 1994 The Center for Applied Engineering, Inc. 94-084 Static Uplift Testing TAS 101 (Mortar Set) May 1994 The Center for Applied Engineering, Inc. 25-7094-(2, 5, & 8) Static Uplift Testing TAS 102 Oct. 1994 The Center for Applied Engineering, Inc. 25-7183-(5 thru 6) Static Uplift Testing TAS 102 Feb. 1995 The Center for Applied Engineering, Inc. 25-7214-(1, 5 , & 8) Static Uplift Testing TAS 102 March, 1995 The Center for Applied Engineering, Inc. 25-7487-2 Static Uplift Testing TAS 102 Dec. 1995 The Center for Applied Engineering, Inc. 25-7496-(1 & 4) Static Uplift Testing TAS 102 Dec. 1995 The Center for Applied Engineering, Inc. 25-7804-6 Static Uplift Testing TAS 102 Sep. 1996 Celotex Corporation Testing Service 520109-1 520111-4 Static Uplift Testing TAS 101 Dec. 1998 Celotex Corporation Testing Service 520191-1 Static Uplift Testing TAS 101 March 1999 Walker Engineering, Inc. Calculations Aerodynamic Multiplier Sep. 2006 Walker Engineering, Inc. Calculations Restoring Moments Due to Gravity Sep. 2006 ATL of South Florida RT1214.01-15 TAS-112 12/17/15 NOA No.:16-0314.06 Expiration Date: 10/05/21 Approval Date: 06/16/16 Page 4 of 9 3 LIMITATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 shall be required, refer to applicable Building Code. 3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix ‘A’. Such testing shall be submitted to the Miami-Dade County Product Control Section for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable Building Code. 4 INSTALLATION: 4.1 Eagle Roofing Products LLC Bel Air, Bel Air Double Eagle, Ponderosa, Golden Eagle, Ponderosa Double Eagle Flat Concrete Roof Tiles and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119 and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (l x w ) Tile Profile Weight-W (lbf) Length-l (ft) Width-w (ft) Bel Air, Bel Air Double Eagle, Ponderosa, Golden Eagle, Ponderosa Double Eagle Flat Tile 11.4 1.42 1.03 Table 2: Aerodynamic Multipliers - λ (ft3) Tile Profile λ (ft3) Batten Application λ (ft3) Direct Deck Application Bel Air, Bel Air Double Eagle, Ponderosa, Golden Eagle, Ponderosa Double Eagle Flat Tile 0.301 0.278 Table 3: Restoring Moments due to Gravity - Mg (ft-lbf) Tile Profile 3":12" 4":12" 5":12" 6":12" Greater than 7":12" Bel Air, Bel Air Double Eagle, Ponderosa, Golden Eagle, Ponderosa Double Eagle Flat Tile Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck 7.48 7.71 7.37 7.59 7.22 7.44 7.05 7.27 6.86 7.07 NOA No.:16-0314.06 Expiration Date: 10/05/21 Approval Date: 06/16/16 Page 5 of 9 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Nail-On Systems Tile Profile Fastener Type Direct Deck (min 15/32” plywood) Direct Deck (min. 19/32” plywood) Battens Bel Air, Bel Air Double Eagle, Ponderosa, Golden Eagle, Ponderosa Double Eagle Flat Tile 2-10d Ring Shank Nails 30.9 38.1 17.2 1-10d Smooth or Screw Shank Nail 7.3 9.8 4.9 2-10d Smooth or Screw Shank Nails 14.0 18.8 7.4 1 #8 Screw 30.8 30.8 18.2 2 #8 Screw 51.7 51.7 24.4 1-10d Smooth or Screw Shank Nail (Field Clip) 24.3 24.3 24.2 1-10d Smooth or Screw Shank Nail (Eave Clip) 19.0 19.0 22.1 2-10d Smooth or Screw Shank Nails (Field Clip) 35.5 35.5 34.8 2-10d Smooth or Screw Shank Nails (Eave Clip) 31.9 31.9 32.2 2-10d Ring Shank Nails1 50.3 65.5 48.3 1. Installation with a 4" tile headlap and fasteners are located a min. of 2½“ from head of tile. Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Attachment Resistance Bel Air, Bel Air Double Eagle, Ponderosa, Golden Eagle, Ponderosa Double Eagle Flat Tile Adhesive1 31.32 1 See manufactures component approval for installation requirements. 2 The Dow Chemical Company TileBond Average weight per patty 13.9 grams. ICP Adhesives Polyset® AH-160 Average weight per patty 8 grams. Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Attachment Resistance Bel Air, Bel Air Double Eagle, Ponderosa, Golden Eagle, Ponderosa Double Eagle Flat Tile ICP Adhesives Polyset® AH-160 118.93 ICP Adhesives Polyset® AH-160 40.44 3 Large paddy placement of 45 grams of PolyPro™. 4 Medium paddy placement of 24 grams of PolyPro™. Table 7: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Mortar Set Systems Tile Profile Tile Application Attachment Resistance Bel Air, Bel Air Double Eagle, Ponderosa, Golden Eagle, Ponderosa Double Eagle Flat Tile Mortar Set5 43.9 5 Tile-Tite Roof Tile Mortar. NOA No.:16-0314.06 Expiration Date: 10/05/21 Approval Date: 06/16/16 Page 6 of 9 5. LABELING : All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo (See Detail Below), or following statement: "Miami-Dade County Product Control Approved". (LOCATED ON UNDERSIDE OF TILE) OR EAGLE FL (LOCATED ON FRONTSIDE OF TILE) BEL AIR, BEL AIR DOUBLE EAGLE, PONDEROSA, GOLDEN EAGLE, PONDEROSA DOUBLE EAGLE CONCRETE ROOF TILE LABEL, SUMTERVILLE PLANT 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by AHJ or applicable Building Code in order to properly evaluate the installation of this system. NOA No.:16-0314.06 Expiration Date: 10/05/21 Approval Date: 06/16/16 Page 7 of 9 PROFILE DRAWING BEL AIR BEL AIR DOUBLE EAGLE NOA No.:16-0314.06 Expiration Date: 10/05/21 Approval Date: 06/16/16 Page 8 of 9 PONDEROSA PONDEROSA DOUBLE EAGLE NOA No.:16-0314.06 Expiration Date: 10/05/21 Approval Date: 06/16/16 Page 9 of 9 GOLDEN EAGLE END OF THIS ACCEPTANCE