HomeMy WebLinkAboutNOA, Boral Villa 900 NOA No.: 18-0509.16 Expiration Date: 09/21/21 Approval Date: 06/28/18 Page 1 of 7 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy Boral Roofing, LLC 7575 Irvine Center Drive, Suite 100 Irvine, CA 92618 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (in Miami-Dade County) and/or the AHJ (in areas other than Miami-Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Boral Villa 900 Concrete Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No.16-0711.04 and consists of pages 1 through 7. The submitted documentation was reviewed by Freddy Semino NOA No.: 18-0509.16 Expiration Date: 09/21/21 Approval Date: 06/28/18 Page 2 of 7 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub Category: Roofing Tiles Material: Concrete 1. SCOPE This renews a system using Boral Villa 900 Concrete Roof Tile, as manufactured Boral Roofing, LLC in Lake Wales, FL and described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Applicant Dimensions Test Specifications Product Description Boral Roofing Villa 900 Length = 17" Width = 13" ½" thick TAS 112 Type 1b Class III Low profile, interlocking, high pressure extruded concrete roof tile equipped with three nail holes and double rolls. For direct deck, batten, mortar or adhesive set applications. Trim Pieces l = varies w = varies varying thickness TAS 112 Accessory trim, concrete roof pieces for use at ridges, hips and rakes. 2.1 PRODUCTS MANUFACTURED BY OTHERS Product Name Product Description Manufacturer (With Current NOA) ICP Adhesives Polyset® AH-160 Two component polyurethane foam adhesive. ICP Adhesives and Sealants, Inc. TILE BONDTM Roof Tile Adhesive Single component polyurethane foam roof tile adhesive. The Dow Chemical Company “Tile Tite” Roof Tile Mortar Premixed, pre-bagged roof tile mortar. Bermuda Roof Co. Inc. DAP Foam Touch N Seal StormBond® 2 Roof Tile Adhesive Two component polyurethane foam adhesive. The Dow Chemical Company 2.2 MANUFACTURING LOCATION 2.2.1. Lake Wales, FL NOA No.: 18-0509.16 Expiration Date: 09/21/21 Approval Date: 06/28/18 Page 3 of 7 2.3 EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Report Date Nutting Engineers 13343.1 TAS 112 Apr. 2006 Redland Technologies 7161-03 Appendix III Static Uplift Testing TAS 102 & TAS 102(A) Dec. 1991 Redland Technologies 7161-03 Appendix II Wind Tunnel Testing TAS 108 (Nail-On) Dec. 1991 Redland Technologies P0402 Withdrawal Resistance Testing of screw vs. smooth shank nails Sept. 1993 The Center for Applied Engineering, Inc. 94-060B Static Uplift Testing TAS 101 (Adhesive Set) March, 1994 The Center for Applied Engineering, Inc. 94-084 Static Uplift Testing TAS 101 (Mortar Set) May 1994 Redland Technologies P0631-01 Wind Tunnel Testing TAS 108 (Mortar Set) July 1994 Redland Technologies Letter Dated Aug. 1, 1994 Wind Tunnel Testing TAS 108 (Nail-On) Aug. 1994 The Center for Applied Engineering, Inc. Project No. 307025 Test #MDC-76 Wind Driven Rain TAS 100 Oct. 1994 The Center for Applied Engineering, Inc. 25-7183-1 25-7183-2 Static Uplift Testing TAS 102 (2 Quik-Drive Screws, Direct Deck) Feb. 1995 The Center for Applied Engineering, Inc. 25-7214-2 25-7214-6 Static Uplift Testing TAS 102 (1 Quik-Drive Screw, Direct Deck) (1 Quik-Drive Screw, Battens) March, 1995 Celotex Corporation Testing Services 528454-2-1 520109-2 Static Uplift Testing TAS 101 Sep. 1998 Dec. 1998 Walker Engineering, Inc. Evaluation Calculations 25-7183 March 1995 Walker Engineering, Inc. Evaluation Calculations 25-7094 February 1996 Walker Engineering, Inc. Evaluation Calculations 25-7496 April 1996 Walker Engineering, Inc. Evaluation Calculations 25-7584 25-7804b-8 25-7804-4 & 5 25-7848-6 December 1996 Walker Engineering, Inc. Evaluation Calculations Aerodynamic Multipliers 09/01/16 Walker Engineering, Inc. Evaluation Calculations Two Patty Adhesive Set System April 1999 Walker Engineering, Inc. Evaluation Calculations Restoring Moment Due to Gravity 09/01/16 American Test Lab of South Florida RT0617.02-16 TAS 112 06/29/16 NOA No.: 18-0509.16 Expiration Date: 09/21/21 Approval Date: 06/28/18 Page 4 of 7 2.3 EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Report Date PRI Construction Materials Technologies COPO-002-02-11 Static Uplift Testing TAS 101 (Adhesive Set) 10/12/2016 PRI Construction Materials Technologies COPO-002-02-04 Static Uplift Testing TAS 101 (Adhesive Set) 10/12/2016 PRI Construction Materials Technologies COPO-002-02-03 Static Uplift Testing TAS 101 (Adhesive Set) 10/12/2016 3. LIMITATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix ‘A’. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications St andards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 4. INSTALLATION 4.1 Villa 900 Concrete Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (l x w ) Tile Profile Weight-W (lbf) Length-l (ft) Width-w (ft) Villa 900 Concrete Tile 10.90 1.42 1.08 Table 2: Aerodynamic Multipliers -  (ft3) Tile Profile  (ft3) Batten Application  (ft3) Direct Deck Application Villa 900 Concrete Tile 0.291 0.315 Table 3: Restoring Moments due to Gravity - Mg (ft.-lbf.) Tile Profile 2":12" 3":12" 4":12" 5":12" 6":12" 7":12" or greater Villa 900 Concrete Tile Direct Deck Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck 7.70 7.62 6.56 7.50 6.42 7.34 6.26 7.15 6.08 6.95 NOA No.: 18-0509.16 Expiration Date: 09/21/21 Approval Date: 06/28/18 Page 5 of 7 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Mechanically Fastened Systems Tile Profile Fastener Type Direct Deck (min 15/32" plywood) Direct Deck (min. 19/32" plywood) Battens Villa 900 Concrete Tile 2-10d Ring Shank Nails 27.8 37.4 28.8 1-10d Smooth or Screw Shank Nail 8.8 11.8 4.1 2-10d Smooth or Screw Shank Nails 16.4 21.9 7.1 1 #8 Screw 25.8 25.8 22.9 2 #8 Screw 47.1 47.1 49.1 1-10d Smooth or Screw Shank Nail (Field Clip) 24.3 24.3 24.2 1-10d Smooth or Screw Shank Nail (Eave Clip) 19.0 19.0 22.1 2-10d Smooth or Screw Shank Nails (Field Clip) 35.5 35.5 34.8 2-10d Smooth or Screw Shank Nails (Eave Clip) 31.9 31.9 32.2 Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf) for Two Paddy Adhesive1 Set Systems Tile Profile Tile Application Minimum Attachment Resistance Villa 900 Concrete Tile The Dow Chemical Company TileBond 26.12 ICP Adhesives Polyset® AH-160 two- component foam 26.13 DAP Foam Touch N Seal StormBond ® 2 Roof Tile Adhesive two-component foam 55 4 1 See foam adhesive manufacturer’s component approval for installation requirements. 2 The Dow Chemical Company TileBond one-component foam, minimum weight per paddy 11.4 grams. 3 ICP Adhesives Polyset® AH-160 two-component foam, minimum weight per paddy 8 grams. 4 DAP Foam Touch N Seal StormBond ® 2 Roof Tile Adhesive, average weight per paddy 8 grams, two component foam. Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Single Paddy Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Villa 900 Concrete Tile ICP Adhesives Polyset® AH-160 two-component foam 86.615 ICP Adhesives Polyset® AH-160 two-component foam 45.5 6 DAP Foam Touch N Seal StormBond ® 2 Roof Tile Adhesive 40 7 DAP Foam Touch N Seal StormBond ® 2 Roof Tile Adhesive 70 8 NOA No.: 18-0509.16 Expiration Date: 09/21/21 Approval Date: 06/28/18 Page 6 of 7 5 Large paddy placement of minimum 54 grams. 6 Medium paddy placement of minimum 24 grams. 7 Medium paddy placement of minimum 30 grams. 8 Large paddy placement of minimum 60 grams. Table 7: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Mortar Set Systems Tile Profile Tile Application Attachment Resistance Villa 900 Concrete Tile Mortar Set6 20.60 6 Tile-Tite Roof Tile Mortar. 5. LABELING 5.1 All tiles shall bear the imprint or identifia ble marking of the manufacturer's name or logo as detailed below, or following statement: "Miami-Dade County Product Control Approved". LABEL FOR BORAL VILLA 900 CONCRETE TILE (LOCATED ON THE UNDERSIDE OF TILE) 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. NOA No.: 18-0509.16 Expiration Date: 09/21/21 Approval Date: 06/28/18 Page 7 of 7 PROFILE DRAWING VILLA 900 CONCRETE ROOF TILE END OF THIS ACCEPTANCE