HomeMy WebLinkAboutEnergy Calcs and AC Plan - Stefani 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: STEFANI RESIDENCE Builder Name:
Street: 20024 SOUTHERN STAR DRIVE Permit Office: ST LUCIE COUNTY
City,State,Zip: FORT PIERCE,FL,34945 Permit Number: Y
U
Owner: DONALD STEFANI Jurisdiction: ST LUCIE COUNTY w
Design Location: FL,Fort Pierce U
COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA,
General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall
The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material.
requirements Breaks or joints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit
Ceiling/attic insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier.
Access openings,drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a
Knee walls shall be sealed. material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows,skylights The space between window/door jambs and framing,and
and doors skylights and framing shall be sealed.
Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated.
Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to
(including maintain permanent contact with the underside of
above-garage subfloor decking,or floor framing cavity insulation shall
and cantilevered floors) be permitted to be in contact with the top side of
sheathing,or continuous insulation installed on the
underside of floor framing and extends from the bottorr
to the top of all perimeter floor framing members.
Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation,insulation
Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls.
Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit,or narrow
Narrow cavities cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building
be sealed to the drywall. thermal envelope shall be air tight and IC rated.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring an J
plumbing in exterior walls,or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring.
Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be
on exterior wall tubs shall separate them from the showers and tubs. insulated.
Electrical/phone box on The air barrier shall be installed behind electrical or communication
exterior walls boxes or air-sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub-floor or drywall.
Concealed When required to be sealed,concealed fire sprinklers shall only be sealed
sprinklers in a manner that is recommended by the manufacturer.Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover plates and walls or ceilings.
a.In addition,inspection of log walls shall be in accordance with the provisions of[CC-400.
5/8/2020 12:17 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 1
This document was created with Win2PDF available at http://www.win2pdf.com.
The unregistered version of Win2PDF is for evaluation or non-commercial use only.
This page will not be added after purchasing Win2PDF.
E
o
V N O
INTICOLUMN MONO WALL TrP E)Cr MONO W/STEP SIB i ISOLA rL
TED COLUMN w O — V C
.:.a.:. . . . . .: .. >.....:..: Mai. 0 CIO
.....r. ..::
CD
a•
.... :,s.. _.s
•N .0. = <0 N N
W
A::n EXT MONO W/CURB/RECESS
777—� ® C c') J
EXT DEEP MONO LLILI
U
C)
— — — — — — — — — — b . .
U
ADD(2)#5 TOP
IT #5@ 48.OC,WALL DOWEL TO
\ /
\ / EXT MONO v :. i:.:^.:c: BOTT WILL SUFFICE
\ / I
\ / w
jX\ GARAGE FOOTING DETAILS
/ \ SCALE:112"=T-0" w
/ \ I
/ \ o
/ \ w
/ \ I o
- - - - - - - - - - � w
0
w
0
FSK Hl,J HWH w
a
Lo A
DR WA Folding — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — >< w
_ W (� a
y
t
IC9� Z LL
MU O M 1 W z
LAUNDRY I! 56D .' dOk(J� U ® o
Z U3
� ta`LZJ REAR PORCH } LL
®1/ Fn
� FUTURE OUTDOOR SKLu
a KB"R
B.R.3
L w
� y
Z
(t2x� a 12XSxn
f 8 x7 LL Q LEo
REF lr� /P'� z
I V 36WxC140 ]�`w� VJ
toO
l�C14 gl® Z N <
N 5
— -� — — — — — — — l®xcvX's w
Q PEAK G„
3C L� O O
� $ O o
00 ZIVI
B.R.2 L0�
!®` l� 101
t®Xt '8 �OXtvxCp
SK g r(! R
C� u SWR v�\ SWR
AL (B 1.!(� — \ — — — — — — —\ — — — —�BOTT OF VAULT �1O ILO
_ )\ Lo TUB N
G — — — — [CSJ
— — — — — — — — — — — — — — — — — — — — —
FAUX CLG BEAMF-
I Z
I I I LU
� I 2-
0 0O
09 lilt
II II
DINING ��1�-�^ DEN
I II Q
F F-1 ®RIC O I
0
II II o
� Er floor plan dim
I II
I I 4/16/20
II II
SHEET
FRONT PORCH -2
� I II
I ', II
® - - - - - - - - - - - - - - - - - - - - - - - - - - - - m - - - - - - - - - - - - - - - - - - -
FLOOR PLAN
SCALE: 1/4"=T-0"
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: STEFANI RESIDENCE Builder Name:
Street: 20024 SOUTHERN STAR DRIVE Permit Office: ST LUCIE COUNTY
City,State,Zip: FORT PIERCE,FL,34945 Permit Number:
Owner: DONALD STEFANI Jurisdiction: ST LUCIE COUNTY
Design Location: FL,Fort Pierce County: St.Lucie(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types (2392.0 sgft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 2216.00 ft2
b.Frame-Wood,Adjacent R=13.0 176.00 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 3 d.N/A R= ft2
5. Is this a worst case? No 10.Ceiling Types (2431.0 sqft.) Insulation Area a.Roof Deck(Unvented) R=20.0 2431.00 ft2
6. Conditioned floor area above grade(ft2) 2431 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(369.3 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Garage 6 175
a. U-Factor: Sgl,U=0.45 216.33 ft2
SHGC: SHGC=0.25
b. U-Factor: Sgl,U=0.45 153.00 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.30 a.Central Unit 41.0 SEER:16.00
c. U-Factor: N/A ft2
SHGC: 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Strip Heat 27.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 9.584 ft.
Area Weighted Average SHGC: 0.271 14.Hot water systems
8. Floor Types (2431.0 sqft.) Insulation Area a.Electric Cap:50 gallons
EF:0.980
a.Slab-On-Grade Edge Insulation R=0.0 2431.00 ft2 b. Conservation features
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits None
Glass/Floor Area: 0.152
Total Proposed Modified Loads: 80.60 PASS
Total Baseline Loads: 80.62
1 hereby certify that the plans and specifications covered by Review of the plans and COD ME
this calculation are in compliance with the Florida Energy specifications covered by this
Code. calculation indicates compliance • .Q
with the Florida Energy Code. " G
PREPARED BY: Before construction is completed
DATE: - - this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance Florida Statutes. j+ _
with the Florida Energy Code. OE IRE2��y�
OWNER/AGENT: BUILDING OFFICIAL:
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
5/8/2020 12:16 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: STEFANI RESDENCE Bedrooms: 3 Address Type: Street Address
Building Type: User Conditioned Area: 2431 Lot#
Owner Name: DONALD STEFANI Total Stories: 1 Block/Subdivision:
#of Units: 1 Worst Case: No PlatBook:
Builder Name: Rotate Angle: 0 Street: 20024 SOUTHERN STA
Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St.Lucie
Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City,State,Zip: FORT PIERCE,
Family Type: Single-family FL, 34945
New/Existing: New(From Plans)
Comment:
CLIMATE
Design Temp Int Design Temp Heating Design Daily Temp
v Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Fort Pierce FL VERO BEACH MUNI 39 90 70 75 299 62 Low
BLOCKS
Number Name Area Volume
1 Entire House 2431 22336
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 LAUNDRY 66 528 No 0 1 Yes Yes Yes
2 MUDROOM 66 528 No 0 1 Yes Yes Yes
3 BEDROOM 3 169 1352 No 0 1 1 Yes Yes Yes
4 BEDROOM 2 164 1312 No 0 1 1 Yes Yes Yes
5 CLST 2 18 144 No 0 1 Yes Yes Yes
6 BATH 2 60 480 No 0 1 Yes Yes Yes
7 WIC 2 25 200 No 0 1 No Yes Yes
8 PANTRY 40 320 No 0 1 No Yes Yes
9 HALLWAY 91 728 No 0 1 No Yes Yes
10 BATH 3 45 360 No 0 1 Yes Yes Yes
11 KITCHEN 362 4344 Yes 0 1 Yes Yes Yes
12 LIVING RM 360 4320 No 0 1 Yes Yes Yes
13 FOYER/DINING 234 1872 No 0 1 Yes Yes Yes
14 DEN 143 1144 No 0 1 Yes Yes Yes
15 M BATH 169 1352 No 0 1 Yes Yes Yes
16 M TOILET 28 224 No 0 1 No Yes Yes
17 M WIC 1 56 448 No 0 1 Yes Yes Yes
18 M W IC 2 35 280 No 0 1 No Yes Yes
19 MASTER BEDROO 300 2400 No 0 1 1 Yes Yes Yes
5/8/2020 12:16 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 2 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulation LAUNDRY 6 ft 0 66 ft2 -_-- 1 0 0
2 Slab-On-Grade Edge Insulation MUDROOM 6 ft 0 66 ft2 ---- 1 0 0
3 Slab-On-Grade Edge Insulation BEDROOM 3 13 ft 0 169 ft2 ---- 1 0 0
4 Slab-On-Grade Edge Insulation BEDROOM 2 25 ft 0 164 ft2 ---- 1 0 0
5 Slab-On-Grade Edge Insulation CLST 2 2 ft 0 18 ft2 ---- 1 0 0
6 Slab-On-Grade Edge Insulation BATH 2 loft 0 60 ft2 ---- 1 0 0
7 Slab-On-Grade Edge Insulation WIC 2 1 ft 0 25 ft2 ---- 1 0 0
8 Slab-On-Grade Edge Insulation PANTRY 1 ft 0 40 ft2 ---- 1 0 0
9 Slab-On-Grade Edge Insulation HALLWAY 1 ft 0 91 ft2 ---- 1 0 0
10SIab-On-Grade Edge Insulation BATH 3 7 ft 0 45 ft2 ---- 1 0 0
11SIab-On-Grade Edge Insulation KITCHEN 21 ft 0 362 ft2 ---- 1 0 0
12SIab-On-Grade Edge Insulation LIVING RM 25 ft 0 360 ft2 ---- 1 0 0
13SIab-On-Grade Edge Insulation FOYER/DINING 31 ft 0 234 ft2 ---- 1 0 0
14SIab-On-Grade Edge Insulation DEN 24 ft 0 143 ft2 ---- 1 0 0
15SIab-On-Grade Edge Insulation M BATH 26 ft 0 169 ft2 ---- 1 0 0
16SIab-On-Grade Edge Insulation M TOILET 1 ft 0 28 ft2 ---- 1 0 0
17SIab-On-Grade Edge Insulation M W IC 1 8 ft 0 56 ft2 ---- 1 0 0
18SIab-On-Grade Edge Insulation M W IC 2 1 ft 0 35 ft2 ---- 1 0 0
19SIab-On-Grade Edge Insulation MASTER BEDRO 50 ft 0 300 ft2 ---- 1 0 0
ROOF
Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch
V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg)
1 Hip Metal 2633 ft2 0 ft2 Light N 0.4 No 0.9 No 20 22.6
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Unvented 0 2431 ft2 N N
5/8/2020 12:16 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 3 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Unvented) LAUNDRY 0 Blown 66 ft2 0.1 Wood
2 Under Attic(Unvented) MUDROOM 0 Blown 66 ft2 0.1 Wood
3 Under Attic(Unvented) BEDROOM 3 0 Blown 169 ft2 0.1 Wood
4 Under Attic(Unvented) BEDROOM 2 0 Blown 164 ft2 0.1 Wood
5 Under Attic(Unvented) CLST 2 0 Blown 18 ft2 0.1 Wood
6 Under Attic(Unvented) BATH 2 0 Blown 60 ft2 0.1 Wood
7 Under Attic(Unvented) WIC 2 0 Blown 25 ft2 0.1 Wood
8 Under Attic(Unvented) PANTRY 0 Blown 40 ft2 0.1 Wood
9 Under Attic(U nvented) HALLWAY 0 Blown 91ft2 0.1 Wood
10 Under Attic(Unvented) BATH 3 0 Blown 45 ft2 0.1 Wood
11 Under Attic(Unvented) KITCHEN 0 Blown 362 ft2 0.1 Wood
12 Under Attic(Unvented) LIVING RM 0 Blown 360 ft2 0.1 Wood
13 Under Attic(Unvented) FOYER/DINING 0 Blown 234 ft2 0.1 Wood
14 Under Attic(Unvented) DEN 0 Blown 143 ft2 0.1 Wood
15 Under Attic(Unvented) M BATH 0 Blown 169 ft2 0.1 Wood
16 Under Attic(Unvented) M TOILET 0 Blown 28 ft2 0.1 Wood
17 Under Attic(Unvented) M W IC 1 0 Blown 56 ft2 0.1 Wood
18 Under Attic(Unvented) M W IC 2 0 Blown 35 ft2 0.1 Wood
19 Under Attic(Unvented) MASTER BEDRO 0 Blown 300 ft2 0.1 Wood
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Belowo
To Wall Typ,
Ft An
1 S Exterior Concrete Block-Int Insul LAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0
2 W Garage Frame-Wood LAUNDRY 13 11 0 8 0 88.0 ft2 0 0.1 0.4 0
3 N Exterior Concrete Block-Int InsuIMUDROOM 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0
4 W Garage Frame-Wood MUDROOM 13 11 0 8 0 88.0 ft2 0 0.1 0.4 0
5 S Exterior Concrete Block-Int InsuBEDROOM 3 4.1 13 0 8 0 104.0 ft2 0 0 0.4 0
6 E Exterior Concrete Block-Int InsuBEDROOM 2 4.1 13 0 8 0 104.0 ft2 0 0 0.4 0
7 S Exterior Concrete Block-Int InsuBEDROOM 2 4.1 12 0 8 0 96.0 ft2 0 0 0.4 0
8 S Exterior Concrete Block-Int Insul CLST 2 4.1 2 0 8 0 16.0 ft2 0 0 0.4 0
9 E Exterior Concrete Block-Int Insul BATH 2 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0
10 N Exterior Concrete Block-Int Insul BATH 3 4.1 7 0 8 0 56.0 ft2 0 0 0.4 0
11 E Exterior Concrete Block-Int Insul KITCHEN 4.1 1 0 12 0 12.0 ft2 0 0 0.4 0
12 W Exterior Concrete Block-Int Insul KITCHEN 4.1 20 0 12 0 240.0 ft2 0 0 0.4 0
13 E Exterior Concrete Block-Int Insul LIVING RM 4.1 7 0 12 0 84.0 ft2 0 0 0.4 0
14 W Exterior Concrete Block-Int Insul LIVING RM 4.1 18 0 12 0 216.0 ft2 0 0 0.4 0
15 E Exterior Concrete Block-Int InsuFOYER/DINI 4.1 18 0 8 0 144.0 ft2 0 0 0.4 0
16 S Exterior Concrete Block-Int InsuFOYER/DINI 4.1 13 0 8 0 104.0 ft2 0 0 0.4 0
17 N Exterior Concrete Block-Int Insul DEN 4.1 13 0 8 0 104.0 ft2 0 0 0.4 0
18 E Exterior Concrete Block-Int Insul DEN 4.1 11 0 8 0 88.0 ft2 0 0 0.4 0
19 N Exterior Concrete Block-Int Insul M BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.4 0
20 E Exterior Concrete Block-Int Insul M BATH 4.1 18 0 8 0 144.0 ft2 0 0 0.4 0
21 N Exterior Concrete Block-Int Insul M W IC 1 4.1 8 0 8 0 64.0 ft2 0 0 0.4 0
5/8/2020 12:16 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 4 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Belowo
To Wall Type
22 N Exterior Concrete Block-Int InsuMASTER BE 4.1 18 0 8 0 144.0 ft2 0 0 0.4 0
23 S Exterior Concrete Block-Int InsuMASTER BE 4.1 14 0 8 0 112.0 ft2 0 0 0.4 0
24 W Exterior Concrete Block-Int InsuMASTER BE 4.1 18 0 8 0 144.0 ft2 0 0 0.4 0
WINDOWS
Orientation shown is the entered,Proposed orientation.
Wall Overhang
v # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening
1 S 1 Vinyl Low-E Single Yes 0.45 0.25 N 6.0 ft2 2 ft 0 in 1 ft 4 in None None
2 N 3 Vinyl Low-E Single Yes 0.45 0.25 N 21.3 ft2 8 ft 0 in 1 ft 4 in None None
3 S 5 Vinyl Low-E Single Yes 0.45 0.25 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None
4 E 6 Vinyl Low-E Single Yes 0.45 0.25 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None
5 W 12 Vinyl Low-E Single Yes 0.45 0.3 N 25.0 ft2 15 ft 0 in 1 ft 4 in None None
6 W 14 Vinyl Low-E Single Yes 0.45 0.3 N 128.0 ft2 15 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5
7 E 15 Vinyl Low-E Single Yes 0.45 0.25 N 30.0 ft2 8 ft 0 in 1 ft 4 in None None
8 E 15 Vinyl Low-E Single Yes 0.45 0.25 N 24.0 ft2 8 ft 0 in 1 ft 4 in None None
9 S 16 Vinyl Low-E Single Yes 0.45 0.25 N 15.0 ft2 8 ft 0 in 1 ft 4 in None None
10 N 17 Vinyl Low-E Single Yes 0.45 0.25 N 15.0 ft2 8 ft 0 in 1 ft 4 in None None
11 E 18 Vinyl Low-E Single Yes 0.45 0.25 N 30.0 ft2 8 ft 0 in 1 ft 4 in None None
12 E 20 Vinyl Low-E Single Yes 0.45 0.25 N 15.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5
13 W 24 Vinyl Low-E Single Yes 0.45 0.25 N 30.0 ft2 2 ft 0 in 1 ft 4 in None None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 572 ft2 572 ft2 22 ft 8 ft 13
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 W holehouse Proposed ACH(50) .000409 2605.9 143.06 269.04 .1497 7
HEATING SYSTEM
# System Type Subtype Speed Efficiency Capacity Block Ducts
1 Electric Strip Heat/ None COP:1 27 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ Split Single SEER: 16 41 kBtu/hr 1230 cfm 0.8 1 sys#1
5/8/2020 12:16 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 5 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.98 50 gal 62.3 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
DUCTS
----Supply---- ----Return---- Air CFM 25 CFM25 HVAC#
v # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool
1 Attic 6 175 ft2 Attic 18 ft2 Default Leakage Garage (Default)c(Default)c 1 1
TEMPERATURES
Programable Thermostat: N Ceiling Fans: rj
Cooling Jan Feb Mar Apr
Jun
Nov H Dec
Oct
Mar
Nov Dec
VentinHeating H Jan H Feb l Jan Feb xJ Mar Apr Mayr May Jun rl Jul rj
Aug �Xj
Sep Oct �Oct xJ Nov Dec
Jun Jul Aug Sep
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(W D) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 80 80 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 80 80 78 78 78 78 78 78 78 78
Heating(WD) AM 65 65 65 65 65 65 65 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 68 68
Heating(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 68 68
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 LAUNDRY
Default(8 Ibs/sq.ft. ft2 ft 0.3 MUDROOM
Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 3
Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2
Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 2
Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2
Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 2
Default(8 Ibs/sq.ft. ft2 ft 0.3 PANTRY
Default(8 Ibs/sq.ft. ft2 ft 0.3 HALLWAY
Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 3
Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN
Default(8 Ibs/sq.ft. ft2 ft 0.3 LIVING RM
Default(8 Ibs/sq.ft. ft2 ft 0.3 FOYER/DINING
Default(8 Ibs/sq.ft. ft2 ft 0.3 DEN
Default(8 Ibs/sq.ft. ft2 ft 0.3 M BATH
Default(8 Ibs/sq.ft. ft2 ft 0.3 M TOILET
5/8/2020 12:16 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 6 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 Ibs/sq.ft. ft2 ft 0.3 M W IC 1
Default(8 Ibs/sq.ft. ft2 ft 0.3 M W IC 2
Default(8 Ibs/sq.ft. ft2 ft 0.3 MASTER BEDROO
5/8/2020 12:16 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 7 of 7
This document was created with Win2PDF available at http://www.win2pdf.com.
The unregistered version of Win2PDF is for evaluation or non-commercial use only.
This page will not be added after purchasing Win2PDF.
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition 1. New(From Plans) 12. Ducts, location & insulation level
a) Supply ducts R 6.0
2. Single-family or multiple-family 2. Single-family b) Return ducts R 6.0
c)AHU location Garage
3. No. of units (if multiple-family) 3. 1
4. Number of bedrooms 4. 3 13. Cooling system: Capacity 41.0
a) Split system SEER 16.0
5. Is this a worst case? (yes/no) 5. No b)Single package SEER
c)Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.) 6. 2431 d) Room unit/PTAC EER
e)Other
7. Windows, type and area
a) U-factor:(weighted average) 7a. 0.450
b)Solar Heat Gain Coefficient(SHGC) 7b. 0.271 14. Heating system: Capacity 27.0
c)Area 7c. 369.3 a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights c) Electric resistance COP 1.0
a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient(SHGC) 8b. NA e) Gas furnace, LPG AFUE
f)Other
9. Floor type, insulation level:
a) Slab-on-grade(R-value) 9a. 0.0
b)Wood, raised (R-value) 9b. 15. Water heating system
c)Concrete, raised (R-value) 9c. a) Electric resistance EF 0.98
b) Gas fired, natural gas EF
10. Wall type and insulation: c) Gas fired, LPG EF
A. Exterior: d) Solar system with tank EF
1. Wood frame(Insulation R-value) 10A1. e) Dedicated heat pump with tank EF
2. Masonry(Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec%
B. Adjacent: g) Other
1. Wood frame(Insulation R-value) 10B1. 13.0
2. Masonry(Insulation R-value) 10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level a) Ceiling fans
a) Under attic 1 la. 0.0 b) Cross ventilation No
b) Single assembly 11 b. c)Whole house fan No
c) Knee walls/skylight walls 11 c. d) Multizone cooling credit
d) Radiant barrier installed 11 d. No e) Multizone heating credit
f) Programmable thermostat No
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date:
Address of New Home: 20024 SOUTHERN STAR DRIVE City/FL Zip: FORT PIERCE, FL 34945
5/8/2020 12:16:52 PM EnergyGauge®USA 6.0.04(Rev. 1)-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1
This document was created with Win2PDF available at http://www.win2pdf.com.
The unregistered version of Win2PDF is for evaluation or non-commercial use only.
This page will not be added after purchasing Win2PDF.
MIJ�.� N� t*,a alo1 rr Project SummaryJob:
Date: May 08,2020
Entire House By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM
Project • •
For: DONALD STEFANI
20024 SOUTHERN STAR DRIVE, FORT PIERCE, FL 34945
Notes:
Design Information
Weather: Fort Pierce, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 42 °F Outside db 90 °F
Inside db 70 °F Inside db 75 °F
Design TD 28 °F Design TD 15 °F
Daily range M
Relative humidity 50 %
Moisture difference 61 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 29226 Btuh Structure 20287 Btuh
Ducts 7384 Btuh Ducts 10408 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
(none) (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 36610 Btuh Use manufacturer's data n
Rate/swing multiplier 0.95
Infiltration Equipmenf sensible load 29160 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 3988 Btuh
Ducts 2885 Btuh
Central vent (0 cfm) 0 Btuh
Heating Cooling (none)
Area (ft2) 2431 2431 Equipment latent load 6873 Btuh
Volume (ft3) 22336 22336
Air changes/hour 0.32 0.16 Equipment Total Load (Sen+Lat) 36033 Btuh
Equiv.AVF (cfm) 119 60 Req. total capacity at 0.70 S H R 3.5 ton
Heating Equipment Summary Cooling Equipment Summary
Make Make Trane
Trade Trade TRANE
Model Cond 4TTR6042J 1
AHRI ref Coil TEM4AOC42S41++TDR
AHRI ref 8703699
Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER
Heating input 10.3 kW Sensible cooling 28700 Btuh
Heating output 35247 Btuh Latent cooling 12300 Btuh
Temperature rise 23 °F Total cooling 41000 Btuh
Actual air flow 1367 cfm Actual air flow 1367 cfm
Air flow factor 0.037 cfm/Btuh Air flow factor 0.045 cfm/Btuh
Static pressure 1.00 in H2O Static pressure 1.00 in H2O
Space thermostat Load sensible heat ratio 0.82
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
nn��a N�zoM® 2020-May-08 11:38:08
,qcCd � Right-SuiteO Universal 2019 19.0.08 RSU08101 Page 1
E:\Documnets\Wrightsoft HVAC\STEFANI RESDENCE.rup Calc=MJ8 Front Door faces: E
Ml.la �20 Job:
Right-J®Worksheet Entire House Date: May 08,2020
By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM
1 Room name Entire House LAUNDRY
2 Exposed wall 254.0 ft 6.0 ft
3 Room height 9.2 ft 8.0 ft heat/cool
4 Room dimensions 11.0 x 6.0 ft
5 Room area 2431.0 ft2 66.0 ft2
Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load
number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 T� 13A-4ocs 0.143 n 4.00 2.19 480 444 1776 971 0 0 0 0
2 glazing,clr low-e 0.450 n 12.60 11.99 15 0 189 180 0 0 0 0
2 glazing,clr low-e 0.450 n 12.60 11.99 21 0 269 256 0 0 0 0
13A-4ocs 0.143 e 4.00 2.19 656 542 2170 1186 0 0 0 0
11 2 glazing,clr low-e 0.450 a 12.60 29.42 75 5 945 2207 0 0 0 0
2 glazing,clr low-e 0.450 a 12.60 29.93 24 1 302 718 0 0 0 0
2 glazing,clr low-e 0.450 a 12.60 17.53 15 1 189 263 0 0 0 0
W 13A-40cs 0,143 s 4.00 2.19 480 444 1778 971 48 42 168 92
I; GCI 2 glazing,clr low-e 0.450 s 12.60 11.99 6 6 76 72 6 6 76 72
2 glazing,clr low-e 0.450 s 12.60 11.99 30 30 378 360 0 0 0 0
V+✓ 13A-40cs 0.143 w 4.00 2.19 600 417 1670 912 0 0 0 0
I;�CGGII 2 glazing,clr low-e 0.450 w 12.60 29.42 30 2 378 883 0 0 0 0
2 glazing,clr low-e 0.450 w 12.60 29.42 25 2 315 736 0 0 0 0
2 glazing,clr low-e 0.450 w 12.60 17.81 128 6 1613 2280 0 0 0 0
C 16X19-0md 0.408 1.59 1.37 2431 2431 3854 3326 66 66 105 90
F 22A-tph 1.358 38.02 0.00 2431 254 9658 0 66 6 228 0
6 c)AED excursion 635 -66
Envelope loss/gain 25560 15955 577 188
12 a) Infiltration 3666 982 79 21
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 3350 500
Subtotal(lines 6 to 13) 29226 20287 656 709
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 29226 20287 656 709
15 Duct loads 25% 51% 7384 10408 25% 51% 166 364
FFTotal room load 36610 30694 _T 822 1074
Air required(cfm) 1367 1367 31 48
w.,...
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
--4cCb, {I- 2020-May-08 11:38:08
Right-Suite®Universal 2019 19.0.08 RSU08101 Page 1
E:\Documnets\Wrightsoft HVAC\STEFANI RESDENCE.rup Calc=MJ8 Front Door faces: E
Ml.la �20 Job:
Right-J®Worksheet Entire House Date: May 08,2020
By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM
1 Room name MUDROOM BEDROOM 3
2 Exposed wall 6.0 ft 13.0 ft
3 Room height 8.0 ft heat/cool 8.0 ft heat/cool
4 Room dimensions 11.0 x 6.0 ft 13.0 x 13.0 ft
5 Room area 66.0 ft2 169.0 ft2
Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load
number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 T� 13A-4ocs 0.143 n 4.00 2.19 48 27 107 58 0 0 0 0
2 glazing,clr low-e 0.450 n 12.60 11.99 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 n 12.60 11.99 21 0 269 256 0 0 0 0
13A-4ocs 0.143 e 4.00 2.19 0 0 0 0 0 0 0 0
1 1 2 glazing,clr low-e 0.450 a 12.60 29.42 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 a 12.60 29.93 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 a 12.60 17.53 0 0 0 0 0 0 0 0
W 13A-40cs 0,143 s 4.00 2.19 0 0 0 0 104 89 356 195
I; GCI 2 glazing,clr low-e 0.450 s 12.60 11.99 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 s 12.60 11.99 0 0 0 0 15 15 189 180
V+✓ 2 glazing,
0.143 w 2.60 2.19 0 0 0 0 0 0 0 0
I;�CGGII 2 glazing,clr low-e 0.450 w 12.60 29.42 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 w 12.60 29.42 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 w 12.60 17.81 0 0 0 0 0 0 0 0
C 16X19-0md 0.408 1.59 1.37 66 66 105 90 169 169 268 231
F 22A-tph 1.358 38.02 0.00 66 6 228 0 169 13 494 0
6 c)AED excursion -70 -140
Envelope loss/gain 708 334 1308 465
12 a) Infiltration 79 21 172 46
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 400 1000
Subtotal(lines 6 to 13) 788 756 1480 1511
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 11 9 124 56
14 Subtotal 799 764 1604 1567
15 Duct loads 25% 51% 202 392 25% 51% 405 804
FFTotal room load 1001 1156 2009 2372
Air required(cfm) 37 51 75 106
w.,...
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
--4cCb, {I- 2020-May-08 11:38:08
Right-Suite®Universal 2019 19.0.08 RSU08101 Page 2
E:\Documnets\Wrightsoft HVAC\STEFANI RESDENCE.rup Calc=MJ8 Front Door faces: E
Ml.la �20 Job:
Right-J®Worksheet Entire House Date: May 08,2020
By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM
1 Room name BEDROOM 2 CLST 2
2 Exposed wall 25.0 ft 2.0 ft
3 Room height 8.0 ft heat/cool 8.0 ft heat/cool
4 Room dimensions 1.0 x 164.0 ft 9.0 x 2.0 ft
5 Room area 164.0 ft2 18.0 ft2
Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load
number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6T� 13A-4ocs 0.143 n 4.00 2.19 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 n 12.60 11.99 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 n 12.60 11.99 0 0 0 0 0 0 0 0
13A-4ocs 0.143 e 4.00 2.19 104 89 356 195 0 0 0 0
1 1 2 glazing,clr low-e 0.450 a 12.60 29.42 15 1 189 441 0 0 0 0
2 glazing,clr low-e 0.450 a 12.60 29.93 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 a 12.60 17.53 0 0 0 0 0 0 0 0
W 13A-40cs 0,143 s 4.00 2.19 96 96 384 210 16 16 64 35
I; GCI 2 glazing,clr low-e 0.450 s 12.60 11.99 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 s 12.60 11.99 0 0 0 0 0 0 0 0
V+✓ 2 glazing,
0.143 w 2.60 2.19 0 0 0 0 0 0 0 0
I;�CGGII 2 glazing,clr low-e 0.450 w 12.60 29.42 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 w 12.60 29.42 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 w 12.60 17.81 0 0 0 0 0 0 0 0
C 16X19-0md 0.408 1.59 1.37 164 164 260 224 18 18 29 25
F 22A-tph 1.358 38.02 0.00 164 25 951 0 18 2 76 0
6 c)AED excursion -107 -6
Envelope loss/gain 2140 964 169 54
12 a) Infiltration 331 89 26 7
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 400 0
Subtotal(lines 6 to 13) 2471 1452 195 61
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 116 40 -195 -61
14 Subtotal 2587 1493 0 0
15 Duct loads 25% 51% 654 766 25% 51% 0 0
FFTotal room load 3240 2258 0 0
Air required(cfm) 121 101 0 0
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
--4cCb, -I- nn"aN�ao ,.. 2020-May-O8 11:38:08
Right-Suite®Universal 2019 19.0.08 RSU08101 Page 3
E:\Documnets\Wrightsoft HVAC\STEFANI RESDENCE.rup Calc=MJ8 Front Door faces: E
Ml.la �20 Job:
Right-J®Worksheet Entire House Date: May 08,2020
By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM
1 Room name BATH 2 WIC 2
2 Exposed wall 10.0 ft 0 ft
3 Room height 8.0 ft heat/cool 8.0 ft heat/cool
4 Room dimensions 10.0 x 6.0 ft 5.0 x 5.0 ft
5 Room area 60.0 ft2 25.0 ft2
Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load
number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6T� 13A-4ocs 0.143 n 4.00 2.19 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 n 12.60 11.99 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 n 12.60 11.99 0 0 0 0 0 0 0 0
13A-4ocs 0.143 e 4.00 2.19 80 80 320 175 0 0 0 0
1 1 2 glazing,clr low-e 0.450 a 12.60 29.42 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 a 12.60 29.93 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 a 12.60 17.53 0 0 0 0 0 0 0 0
W 13A-40cs 0,143 s 4.00 2.19 0 0 0 0 0 0 0 0
I; GCI 2 glazing,clr low-e 0.450 s 12.60 11.99 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 s 12.60 11.99 0 0 0 0 0 0 0 0
V+✓ 2 glazing,
0.143 w 2.60 2.19 0 0 0 0 0 0 0 0
I;�CGGII 2 glazing,clr low-e 0.450 w 12.60 29.42 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 w 12.60 29.42 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 w 12.60 17.81 0 0 0 0 0 0 0 0
C 16X19-0md 0.408 1.59 1.37 60 60 95 82 25 25 40 34
F 22A-tph 1.358 38.02 0.00 60 10 380 0 25 0 0 0
6 c)AED excursion -42 -3
Envelope loss/gain 796 215 40 31
12 a) Infiltration 132 35 0 0
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 200 0
Subtotal(lines 6 to 13) 928 451 40 31
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 14 11
14 Subtotal 928 451 54 42
15 Duct loads 25% 51% 234 231 25% 51% 14 22
FFTotal room load 1162 682 67 64
Air required(cfm) 43 30 3 3
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
--4cCb, -I- nn"aN�ao ,.. 2020-May-O8 11:38:08
Right-Suite®Universal 2019 19.0.08 RSU08101 Page 4
E:\Documnets\Wrightsoft HVAC\STEFANI RESDENCE.rup Calc=MJ8 Front Door faces: E
Ml.la �20 Job:
Right-J®Worksheet Entire House Date: May 08,2020
By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM
1 Room name PANTRY HALLWAY
2 Exposed wall 0 ft 0 ft
3 Room height 8.0 ft heat/cool 8.0 ft heat/cool
4 Room dimensions 5.0 x 8.0 ft 1.0 x 91.0 ft
5 Room area 40.0 ft2 91.0 ft2
Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load
number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6T� 13A-4ocs 0.143 n 4.00 2.19 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 n 12.60 11.99 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 n 12.60 11.99 0 0 0 0 0 0 0 0
13A-4ocs 0.143 e 4.00 2.19 0 0 0 0 0 0 0 0
11 2 glazing,clr low-e 0.450 a 12.60 29.42 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 a 12.60 29.93 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 a 12.60 17.53 0 0 0 0 0 0 0 0
W 13A-40cs 0,143 s 4.00 2.19 0 0 0 0 0 0 0 0
I; GCI 2 glazing,clr low-e 0.450 s 12.60 11.99 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 s 12.60 11.99 0 0 0 0 0 0 0 0
V+✓ 2 glazing,
0.143 w 2.60 2.19 0 0 0 0 0 0 0 0
I;�CGGII 2 glazing,clr low-e 0.450 w 12.60 29.42 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 w 12.60 29.42 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 w 12.60 17.81 0 0 0 0 0 0 0 0
C 16X19-0md 0.408 1.59 1.37 40 40 63 55 91 91 144 125
F 22A-tph 1.358 38.02 0.00 40 0 0 0 91 0 0 0
6 c)AED excursion -5 -11
Envelope loss/gain 63 50 144 114
12 a) Infiltration 0 0 0 0
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 63 50 144 114
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 22 18 -144 -114
14 Subtotal 86 68 0 0
15 Duct loads 25% 51% 221 35 25% 51% 0 0
Total room load 107 102 0 0
Air required(cfm) 4 5 0 0
w.,...
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
--4cCb, {I- 2020-May-08 11:38:08
Right-Suite®Universal 2019 19.0.08 RSU08101 Page 5
E:\Documnets\Wrightsoft HVAC\STEFANI RESDENCE.rup Calc=MJ8 Front Door faces: E
Ml.la �20 Job:
Right-J®Worksheet Entire House Date: May 08,2020
By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM
1 Room name BATH 3 KITCHEN
2 Exposed wall 7.0 ft 21.0 ft
3 Room height 8.0 ft heat/cool 12.0 ft heat/cool
4 Room dimensions 5.0 x 9.0 ft 1.0 x 362.0 ft
5 Room area 45.0 ft2 362.0 ft2
Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load
number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 T� 13A-4ocs 0.143 n 4.00 2.19 56 56 224 123 0 0 0 0
2 glazing,clr low-e 0.450 n 12.60 11.99 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 n 12.60 11.99 0 0 0 0 0 0 0 0
13A-4ocs 0.143 e 4.00 2.19 0 0 0 0 12 12 48 26
11 2 glazing,clr low-e 0.450 a 12.60 29.42 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 a 12.60 29.93 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 a 12.60 17.53 0 0 0 0 0 0 0 0
W 13A-40cs 0,143 s 4.00 2.19 0 0 0 0 0 0 0 0
I; GCI 2 glazing,clr low-e 0.450 s 12.60 11.99 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 s 12.60 11.99 0 0 0 0 0 0 0 0
V+✓ 13A-40cs 0.143 w 4.00 2.19 0 0 0 0 240 215 861 470
I;�CGGII 2 glazing,clr low-e 0.450 w 12.60 29.42 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 w 12.60 29.42 0 0 0 0 25 2 315 736
2 glazing,clr low-e 0.450 w 12.60 17.81 0 0 0 0 0 0 0 0
C 16X19-0md 0.408 1.59 1.37 45 45 71 62 362 362 574 495
F 22A-tph 1.358 38.02 0.00 45 7 266 0 362 21 799 0
6 c)AED excursion -28 184
Envelope loss/gain 562 156 2596 1911
12 a) Infiltration 93 25 417 112
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 125 100
Subtotal(lines 6 to 13) 654 306 3013 2123
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 39 31 14 11
14 Subtotal 693 336 3027 2134
15 Duct loads 25% 51% 1751 172 25% 51% 765 1095
Total room load 868 509 3792 3228
Air required(cfm) 32 23 142 144
w.,...
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
--4cCb, {I- 2020-May-08 11:38:08
Right-Suite®Universal 2019 19.0.08 RSU08101 Page 6
E:\Documnets\Wrightsoft HVAC\STEFANI RESDENCE.rup Calc=MJ8 Front Door faces: E
Ml.la �20 Job:
Right-J®Worksheet Entire House Date: May 08,2020
By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM
1 Room name LIVING RM FOYER/DINING
2 Exposed wall 25.0 ft 31.0 ft
3 Room height 12.0 ft heat/cool 8.0 ft heat/cool
4 Room dimensions 18.0 x 20.0 ft 18.0 x 13.0 ft
5 Room area 360.0 ft2 234.0 ft2
Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load
number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6T� 13A-4ocs 0.143 n 4.00 2.19 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 n 12.60 11.99 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 n 12.60 11.99 0 0 0 0 0 0 0 0
13A-4ocs 0.143 e 4.00 2.19 84 84 336 184 144 90 360 197
1 1 2 glazing,clr low-e 0.450 a 12.60 29.42 0 0 0 0 30 2 378 883
2 glazing,clr low-e 0.450 a 12.60 29.93 0 0 0 0 24 1 302 718
2 glazing,clr low-e 0.450 a 12.60 17.53 0 0 0 0 0 0 0 0
W 13A-40cs 0,143 s 4.00 2.19 0 0 0 0 104 89 356 195
I; GCI 2 glazing,clr low-e 0.450 s 12.60 11.99 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 s 12.60 11.99 0 0 0 0 15 15 189 180
V+✓ 2 glazing,
0.143 w 2.60 2.19 210 88 352 193 0 0 0 0
I;�CGGII 2 glazing,clr low-e 0.450 w 12.60 29.42 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 w 12.60 29.42 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 w 12.60 17.81 128 6 1613 2280 0 0 0 0
C 16X19-0md 0.408 1.59 1.37 360 360 571 493 234 234 371 320
F 22A-tph 1.358 38.02 0.00 360 25 951 0 234 31 1179 0
6 c)AED excursion 1120 -203
Envelope loss/gain 3823 4269 3136 2290
12 a) Infiltration 496 133 410 110
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 4319 4402 3546 2400
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 4319 4402 3546 2400
15 Duct loads 25% 51% 1091 2258 25% 51% 896 1231
FFTotal room load 5410 6660 4442 3631
Air required(cfm) 202 297 166 162
w.,...
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
--4cCb, {I- 2020-May-08 11:38:08
Right-Suite®Universal 2019 19.0.08 RSU08101 Page 7
E:\Documnets\Wrightsoft HVAC\STEFANI RESDENCE.rup Calc=MJ8 Front Door faces: E
Ml.la �20 Job:
Right-J®Worksheet Entire House Date: May 08,2020
By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM
1 Room name DEN M BATH
2 Exposed wall 24,0 ft 26.0 ft
3 Room height 8.0 ft heat/cool 8.0 ft heat/cool
4 Room dimensions 11.0 x 13.0 ft 1.0 x 169.0 ft
5 Room area 143.0 ft2 169.0 ft2
Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load
number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 T� 13A-4ocs 0.143 n 4.00 2.19 104 89 356 195 64 64 256 140
2 glazing,clr low-e 0.450 n 12.60 11.99 15 0 189 180 0 0 0 0
2 glazing,clr low-e 0.450 n 12.60 11.99 0 0 0 0 0 0 0 0
13A-4ocs 0.143 e 4.00 2.19 88 58 232 127 144 129 517 282
11 2 glazing,clr low-e 0.450 a 12.60 29.42 30 2 378 883 0 0 0 0
2 glazing,clr low-e 0.450 a 12.60 29.93 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 a 12.60 17.53 0 0 0 0 15 1 189 263
W 13A-40cs 0,143 s 4.00 2.19 0 0 0 0 0 0 0 0
I; GCI 2 glazing,clr low-e 0.450 s 12.60 11.99 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 s 12.60 11.99 0 0 0 0 0 0 0 0
V+✓ 2 glazing,
0.143 w 2.60 2.19 0 0 0 0 0 0 0 0
I;�CGGII 2 glazing,clr low-e 0.450 w 12.60 29.42 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 w 12.60 29.42 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 w 12.60 17.81 0 0 0 0 0 0 0 0
C 16X19-0md 0.408 1.59 1.37 143 143 227 196 169 169 268 231
F 22A-tph 1.358 38.02 0.00 143 24 913 0 169 26 989 0
6 c)AED excursion -142 9
Envelope loss/gain 2295 1438 2218 926
12 a) Infiltration 318 85 344 92
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 2613 1523 2562 1018
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 2613 1523 2562 1018
15 Duct loads 25% 51% 660 782 25% 51% 647 522
FFTotal room load 3273 2305 73210 1540
Air required(cfm) 122 103 120 69
w.,...
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
--4cCb, {I- 2020-May-08 11:38:08
Right-Suite®Universal 2019 19.0.08 RSU08101 Page 8
E:\Documnets\Wrightsoft HVAC\STEFANI RESDENCE.rup Calc=MJ8 Front Door faces: E
Ml.la �20 Job:
Right-J®Worksheet Entire House Date: May 08,2020
By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM
1 Room name M TOILET M WIC 1
2 Exposed wall 0 ft 8.0 ft
3 Room height 8.0 ft heat/cool 8.0 ft heat/cool
4 Room dimensions 7.0 x 4.0 ft 7.0 x 8.0 ft
5 Room area 28.0 ft2 56.0 ft2
Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load
number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 T� 13A-4ocs 0.143 n 4.00 2.19 0 0 0 0 64 64 256 140
2 glazing,clr low-e 0.450 n 12.60 11.99 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 n 12.60 11.99 0 0 0 0 0 0 0 0
13A-4ocs 0.143 e 4.00 2.19 0 0 0 0 0 0 0 0
11 2 glazing,clr low-e 0.450 a 12.60 29.42 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 a 12.60 29.93 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 a 12.60 17.53 0 0 0 0 0 0 0 0
W 13A-40cs 0,143 s 4.00 2.19 0 0 0 0 0 0 0 0
I; GCI 2 glazing,clr low-e 0.450 s 12.60 11.99 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 s 12.60 11.99 0 0 0 0 0 0 0 0
V+✓ 2 glazing,
0.143 w 2.60 2.19 0 0 0 0 0 0 0 0
I;�CGGII 2 glazing,clr low-e 0.450 w 12.60 29.42 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 w 12.60 29.42 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 w 12.60 17.81 0 0 0 0 0 0 0 0
C 16X19-0md 0.408 1.59 1.37 28 28 44 38 56 56 89 77
F 22A-tph 1.358 38.02 0.00 28 0 0 0 56 8 304 0
6 c)AED excursion -3 -31
Envelope loss/gain 44 35 649 185
12 a) Infiltration 0 0 106 28
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 125
Subtotal(lines 6 to 13) 44 35 755 339
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 44 35 755 339
15 Duct loads 25% 51% 11 18 25% 51% 191 174
Total room load 56 53 946 512
Air required(cfm) 2 2 35 23
w.,...
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
--4cCb, {I- 2020-May-08 11:38:08
Right-Suite®Universal 2019 19.0.08 RSU08101 Page 9
E:\Documnets\Wrightsoft HVAC\STEFANI RESDENCE.rup Calc=MJ8 Front Door faces: E
Ml.la �20 Job:
Right-J®Worksheet Entire House Date: May 08,2020
By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM
1 Room name M WIC 2 MASTER BEDROOM
2 Exposed wall 0 ft 50,0 ft
3 Room height 8.0 ft heat/cool 8.0 ft heat/cool
4 Room dimensions 7.0 x 5.0 ft 1.0 x 300.0 ft
5 Room area 35.0 ft2 300.0 ft2
Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load
number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 T� 13A-4ocs 0.143 n 4.00 2.19 0 0 0 0 144 144 577 315
2 glazing,clr low-e 0.450 n 12.60 11.99 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 n 12.60 11.99 0 0 0 0 0 0 0 0
13A-4ocs 0.143 e 4.00 2.19 0 0 0 0 0 0 0 0
1 1 2 glazing,clr low-e 0.450 a 12.60 29.42 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 a 12.60 29.93 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 a 12.60 17.53 0 0 0 0 0 0 0 0
W 13A-40cs 0,143 s 4.00 2.19 0 0 0 0 112 112 448 245
I; GCI 2 glazing,clr low-e 0.450 s 12.60 11.99 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 s 12.60 11.99 0 0 0 0 0 0 0 0
V+✓ 2 glazing,
0.143 w 2.60 2.19 0 0 0 0 130 112 456 249
I;�CGGII 2 glazing,clr low-e 0.450 w 12.60 29.42 0 0 0 0 30 2 378 883
2 glazing,clr low-e 0.450 w 12.60 29.42 0 0 0 0 0 0 0 0
2 glazing,clr low-e 0.450 w 12.60 17.81 0 0 0 0 0 0 0 0
C 16X19-0md 0.408 1.59 1.37 35 35 55 48 300 300 476 410
F 22A-tph 1.358 38.02 0.00 35 0 0 0 300 50 1901 0
6 c)AED excursion 4 182
Envelope loss/gain 55 44 4236 2284
12 a) Infiltration 0 0 662 177
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 500
Subtotal(lines 6 to 13) 55 44 4898 2962
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 55 44 4898 2962
15 Duct loads 25% 51% 14 22 25% 51% 1237 1519
FFTotal room load 70 66 6135 4481
Air required(cfm) 3 3 229 200
w.,...
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
--4cCb, {I- 2020-May-08 11:38:08
Right-Suite®Universal 2019 19.0.08 RSU08101 Page 10
E:\Documnets\Wrightsoft HVAC\STEFANI RESDENCE.rup Calc=MJ8 Front Door faces: E
Art Liapfaotr, Duct System Summary Job:
Date: May 08,2020
Entire House By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM
Project • •
For: DONALD STEFANI
20024 SOUTHERN STAR DRIVE, FORT PIERCE, FL 34945
Heating Cooling
External static pressure 1.00 in H2O 1.00 in H2O
Pressure losses 0 in H2O 0 in H2O
Available static pressure 1.00 in H2O 1.00 in H2O
Supply/ return available pressure 0.500/ 0.500 in H2O 0.500/0.500 in H2O
Lowest friction rate 1.000 in/100ft 1.000 in/100ft
Actual air flow 1367 cfm 1367 cfm
Total effective length (TEL) 286 ft
Supply Branch DetailTable
Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv
Name (Btuh) (cfm) (cfm) FIR (in) (in) Matl Ln (ft) Ln (ft) Trunk
BATH 2 h 1162 43 30 1.000 5.0 Ox 0 VIFx 28.2 135.0 st2
BATH 3 h 868 32 23 1.000 5.0 Ox 0 VIFx 11.8 115.0 st 1
BEDROOM 2 h 3240 121 101 1.000 7.0 Ox0 VIFx 31.4 135.0 st2
BEDROOM 3 c 2372 75 106 1.000 7.0 Ox0 VIFx 14.0 115.0 st1
DEN h 3273 122 103 1.000 7.0 Ox0 VIFx 55.1 155.0 st3
FOYER/DINING h 4442 166 162 1.000 8.0 Ox0 VIFx 54.2 155.0 st3
KITCHEN c 3228 142 144 1.000 8.0 Ox0 VIFx 54.6 155.0 st3
LAUNDRY c 1074 31 48 1.000 6.0 Ox0 VIFx 19.8 115.0 st1
LIVING RM-A c 3330 101 148 1.000 8.0 Ox0 VIFx 80.9 175.0 st4
LIVING RM-B c 3330 101 148 1.000 8.0 Ox0 VIFx 54.6 155.0 st3
M BATH h 3210 120 69 1.000 6.0 Ox0 VIFx 79.1 175.0 st4
M TOILET c 53 2 2 1.000 4.0 Ox0 VIFx 76.0 175.0 st4
M WIC 1 h 946 35 23 1.000 5.0 Ox0 VIFx 88.5 195.0 st5
MWIC2 c 66 3 3 1.000 4.0 Ox0 VIFx 78.7 175.0 st4
MASTER BEDROOM h 3068 115 100 1.000 7.0 Ox0 VIFx 90.9 195.0 st5
MASTER BEDROOM-A h 3068 115 100 1.000 7.0 Ox0 VIFx 88.0 195.0 st5
MUDROOM c 1156 37 51 1.000 6.0 Ox0 VIFx 13.1 115.0 st1
PANTRY c 102 4 5 1.000 4.0 Ox0 VIFx 30.0 135.0 st2
WIC 2 c 64 3 3 1.000 4.0 Ox0 VIFx 28.0 135.0 st2
-�j',L�,CCd 2020-May-08 11:38:15
Right-Suite®Universal 2019 19.0.08 RSU08101 Page 1
t E:\Documnets\Wrightsoft HVAC\STEFANI RESDENCE.rup Calc=MJ8 Front Door faces: E
SupplyDetail Table
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk
st5 Peak AVF 264 222 1.000 598 9.0 0 x 0 VinlFlx st4
st4 Peak AVF 490 444 1.000 624 12.0 0 x 0 VinlFlx st3
st3 Peak AVF 1020 1001 1.000 731 16.0 0 x 0 VinlFlx st2
st2 Peak AVF 1191 1139 1.000 674 18.0 0 x 0 VinlFlx st1
st1 Peak AVF 1367 1367 1.000 773 18.0 0 x 0 VinlFlx
TableReturn Branch Detail
Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct
Name Size (in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening (in) Matl Trunk
rb2 Ox0 1367 1367 0 0 0 0 Ox 0 VIFx
-�j',L�,CCd 2020-May-08 11:38:15
Right-Suite®Universal 2019 19.0.08 RSU08101 Page 2