HomeMy WebLinkAboutAmazon DVB1 submittal Prepared For: Amazon Date: March 17, 2020 Customer P.O. Number: Customer Project Number: Sold To: Job Number: Job Name: Amazon MEP Structural Design Amazon DVB1 7440 Commercial Circle FORT PIERCE, FL 34951 Trane U.S. Inc. is pleased to provide the enclosed submittal for your review and approval. Product Summary Qty Product 1 Air-Cooled Scroll 1 Performance Climate Changer (CSAA) Jose Perez Trane U.S. Inc. 2884 Corporate Way Miramar, FL 33025 The attached information describes the equipment we propose to furnish for this project, and is submitted for your approval. Product performance and submittal data is valid for a period of 6 months from the date of submittal generation. If six months or more has elapsed between submittal generation and equipment release, the product performance and submittal data will need to be verified. It is the customer’s responsibility to obtain such verification. Submittal J:\JOBS\44\175353\3\Amazon DVB1 submittal.doc Table Of Contents Product Summary ........................................................................................................................... 1 Air-Cooled Scroll (Item A1) Tag Data .................................................................................................................................................. 3 Product Data ............................................................................................................................................ 3 Performance Data .................................................................................................................................... 3 Product Data Report-CGAM-130pump .................................................................................................... 5 Mechanical Specifications ........................................................................................................................ 7 Unit Dimensions ..................................................................................................................................... 10 Weight, Clearance & Rigging Diagram ................................................................................................... 16 Accessory .............................................................................................................................................. 19 Field Wiring ............................................................................................................................................ 23 Performance Climate Changer (CSAA) (Item B1) Tag Data ................................................................................................................................................ 26 Product Data .......................................................................................................................................... 26 Performance Data .................................................................................................................................. 27 Mechanical Specifications ...................................................................................................................... 30 As-Built ................................................................................................................................................... 34 Fan Curve .............................................................................................................................................. 43 Accessory .............................................................................................................................................. 45 Field Wiring ............................................................................................................................................ 53 Field Installed Options - Part/Order Number Summary Performance Climate Changer (CSAA) .................................................................................................. 54 Amazon MEP Structural Design Amazon DVB1 March 17, 2020 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 3 of 54 Tag Data - Air-Cooled Scroll (Qty: 1) Item Tag(s) Qty Description Model Number A1 CGAM-130p ump 1 20-130 Ton Air-Cooled (CGAM) CGAM130F2**2AXB2A1B1A1AXXA1D1A4XXX8B1B1 A3A1D1X-L-X Product Data - Air-Cooled Scroll Item: A1 Qty: 1 Tag(s): CGAM -130pump Air-Cooled Scroll Packaged Chiller Startup Included - Trane Service must start equipment for warranty to be honored 130 nominal tons 60 hertz 460 volt 3 phases High efficiency/performance Full factory refrigerant charge (HFC-410A) With factory installed freeze protection Refrigerant isolation valves (discharge valve) UL listed to US and Canadian safety standard ASHRAE 90.1 all versions up to 2016 AHRI certified Factory installed flow switch - set point 60 cm/sec Phase reversal protection Std cooling (40 to 65F/4.44 to 18C) Grooved pipe connection Factory insulation 1.25" - high humidity/low evaporator temperature Performance based on water High ambient (up to 125F/up to 52C) Lanced aluminum fins Across the line starter/direct on line Single point connection main line unit power-ancillary items require other power Circuit breaker-high fault rated control panel Enclosure type UL 1995 rated for outdoor applications BACnet interface Dual high head pump Pump flow ctrl by var speed drive With buffer storage tank High A short circuit rating Elastomeric isolators With water strainer factory installed Super quiet Architectural louvered panels 2nd-5th year compressor parts 1st year labor warranty Performance Data - Air-Cooled Scroll Tags CGAM-130pump Refrigeration capacity (tons) 126.06 Total chiller power (kW) 146.77 Cooling efficiency (EER (Btu/W -h)) 10.306 NPLV.IP (EER (Btu/W -h)) 16.553 IPLV.IP (EER (Btu/W -h)) 16.554 Sound power level (dBA) 95 Sound pressure level (dBA) 67 Refrigerant R410A Refrigerant charge circuit 1 (lb) 112.0 Refrigerant charge circuit 2 (lb) 112.0 Oil charge circuit 1 (gal) 5.81 Oil charge circuit 2 (gal) 5.81 Entering fluid evap (F) 53.98 Leaving fluid evap (F) 44.00 Flow evap (gpm) 301.81 Amazon MEP Structural Design Amazon DVB1 March 17, 2020 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 4 of 54 Tags CGAM-130pump Min flow evap (gpm) 146.90 Min flow PD evap+strainer (ft H2O) 5.99 Evap fluid freeze point (F) 32.00 Fluid pressure drop evap (ft H2O) 14.77 Total PD evap+strainer (ft H2O) 20.92 Evap fouling factor (hr-sq ft-deg F/ Btu) 0.000100 Saturated evap temp circuit 1 (F) 37.64 Saturated evap temp circuit 2 (F) 37.63 Ambient air temperature (F) 95.00 Altitude (ft) 0.00 Saturated cond temp circuit 1 (F) 123.54 Saturated cond temp circuit 2 (F) 123.54 Compressor power input (kW) 134.35 RLA - compressor 1A (A) 33.00 LRA - compressor 1A (A) 215.00 RLA - compressor 1B (A) 33.00 LRA - compressor 1B (A) 215.00 RLA - compressor 1C (A) 41.90 LRA - compressor 1C (A) 260.00 RLA - compressor 2A (A) 41.90 LRA - compressor 2A (A) 260.00 RLA - compressor 2B (A) 33.00 LRA - compressor 2B (A) 215.00 RLA - compressor 2C (A) 33.00 LRA - compressor 2C (A) 215.00 Total airflow (cfm) 91332 Number of fans ( ) 10 Fan power (kW) 12.22 Total fan FLA (A) 33.00 Pump size (kW) 11.33 Pump nominal current (A) 21.00 Expansion tank volume (gal) 6.30 Buffer tank volume (gal) 201.00 Avail head pressure at water connection (ft H2O) 76.98 Total PD pump+evap+strainer (ft H2O) 26.76 Single point power MCA (A) 285.10 Single point power MOP (A) 300.00 Short circuit current rating (A) 65000.00 Number of compressors ( ) 6 Number of circuits ( ) 2 Refrigeration capacity steps ( ) 6 Shipping weight (lb) 9721.9 Operating weight (lb) 11622.8 Length (in) 202 Width (in) 89 Height (in) 92 Amazon MEP Structural Design Amazon DVB1 March 17, 2020 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 5 of 54 20-130 Ton Air-Cooled Job Information High efficiency Unit type Unit nominal tonnage 130 tons 1 Quantity Model Number CGAM-130pump Tag CGAM 130 233 TOPSS version number General Information Sound attenuator package Super quiet IPLV.IP 16.55 EER (Btu/W-h) Refrigerant R410A NPLV.IP 16.55 EER (Btu/W-h) Refrigeration capacity 126.1 tons Sound power level 95 dBA Full load refrigeration efficiency 10.31 EER (Btu/W-h) 67 dBA Sound pressure level * Note: * At 30 feet in free field. Evaporator Information Evaporator application Std cooling Fouling factor 0.000100 hr-sq ft-deg F/ Btu Entering temperature 53.98 F Saturated temperature-ckt 1 37.6 F Leaving temperature 44.00 F Saturated temperature-ckt 2 37.6 F Fluid flow rate 301.8 gpm Minimum flow rate 146.9 gpm Pressure drop 14.8 ft H2O Pressure drop at min flow rate 5.99 ft H2O Total PD evap+strainer 20.9 ft H2O Flow switch set point Flow switch set point 60 cm/sec Evap fluid type Water With freeze protection Freeze protection (factory inst) Evap fluid freeze point 32.00 F Condenser Information Unit application High ambient Total fan FLA 33.00 A Ambient air temperature 95.0 F 91332 cfm Total airflow Elevation 0.000 ft Fin material Lanced aluminum Number of fans 10.00 Each Saturated temperature-ckt 1 123.5 F Fan power 12.22 kW Saturated temperature-ckt 2 123.5 F Number of compressors 6 RLA LRA Compressor Information Number of circuits 2 Compressor A 33.00 A 215.00 A Refrigeration capacity steps 6 Compressor B 33.00 A 215.00 A Compressor power input 134.4 kW Compressor C 41.90 A 260.00 A Compressor D 41.90 A 260.00 A Compressor E 33.00 A 215.00 A Compressor F 33.00 A 215.00 A Electrical Information MOP MCA Unit voltage 460. volt 3 phases Unit hertz 60. hertz Single point power 285 A 300 A Incoming power line connection Single point Short circuit High Starter type Across the line Short circuit current rating 65000 A Total power input 146.8 kW Note: Unit power includes: compressors, condenser fans, and control kW 3/17/2020 Page 1 of 2 233 Data generation date 3/17/2020 TOPSS version number Amazon MEP Structural Design Amazon DVB1 March 17, 2020 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 6 of 54 20-130 Ton Air-Cooled Job Information High efficiency Unit type Unit nominal tonnage 130 tons 1 Quantity Model Number CGAM-130pump Tag CGAM 130 233 TOPSS version number Certified in accordance with the AHRI Air-Cooled Water-Chilling Packages Certification Program which is based on AHRI Standard 550/590 (I-P). Certified units may be found in the AHRI directory at www.ahridirectory.org. Pump Package Information Pump type Dual high head 15.196 hp Pump size 77.0 ft H2O Avail head pressure at water connection 21.00 A Pump nominal current 6.30 gal Expansion tank volume Total PD pump+evap+strainer 26.8 ft H2O Buffer tank With buffer storage tank Pump flow control Var speed drive 201.00 gal Buffer tank volume Physical Information 202 in Length Water connection (inlet) 4.000 in 89 in Width 112.0 lb Refrigerant charge circuit 1 92 in Height Refrigerant charge circuit 2 112.0 lb 11623 lb Operating weight Oil charge circuit 1 5.81 gal 9722 lb Shipping weight Oil charge circuit 2 5.81 gal Note: This information includes the pump and buffer tank. Information for LEED Projects ASHRAE 90.1/CSA compliance ASHRAE all to 2016 IPLV 16.55 EER (Btu/W-h) 112.0 lb Refrigerant charge circuit 1 Rated refrigeration capacity (AHRI) 126.1 tons 112.0 lb Refrigerant charge circuit 2 Rated cooling efficiency 10.31 EER (Btu/W-h) Note: This product meets the minimum efficiency requirements of ASHRAE Standard 90.1 and CANS/CSA C743 for all versions (which are based on AHRI standard rating conditions) and, therefore, also meets the LEED "Minimum Energy Performance" prerequisite in the Energy and Atmosphere section. The LEED Green Building Rating Systemâ„¢, developed by the U.S. Green Building Council, provides independent, third-party verification that a building project meets green building and performance measures. 3/17/2020 Page 2 of 2 233 Data generation date 3/17/2020 TOPSS version number Amazon MEP Structural Design Amazon DVB1 March 17, 2020 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 26 of 54 Tag Data - Performance Climate Changer (CSAA) (Qty: 1) Item Tag(s) Qty Description Model Number B1 AHU-whse 1 Performance Climate Changer (CSAA) CSAA080UB Product Data - Performance Climate Changer (CSAA) Item: B1 Qty: 1 Tag(s): AHU-whse Unit level options Outdoor unit Unit size 80 No 6in. integral base frame UL listed unit Single metal handle - ganged latches 142.63 Unit length Field Provided (mtrs, lights, controls) No seismic certification required Controls and VFD/starter Supply fan field provided VFD Return/exhaust fan no NEMA Energy wheel field provided starter or no wheel CDQ field provided starter or no wheel Warranty Standard warranty only Pipe cabinet section No pipe cabinet YES YES YES YES YES YES YES YES YES YES YES YES Air mixing section (Pos #1) Air mixing section Mixing box w/filter Door- right side Back damper - parallel blade Front full face opening Left side - High velocity parallel 2in. filter frame Pleated media - run set (Fld) Coil section (Pos #2) Horizontal coil Medium Door- right side Stainless steel drain pan Left side - drain connection Left side - coil supply Service panel opposite connection side Unit coil height Cooling coil Chilled water Single use coil Type "UU" coil 4 rows 84 fins per foot nominal fin spacing Aluminum fins Amazon MEP Structural Design Amazon DVB1 March 17, 2020 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 27 of 54 Delta flo H (Hi efficient) .016" (0.406 mm) copper tubes 1/2in. tube diameter (12.7 mm) Galvanized steel coil casing Turbulators Fan section (Pos #3) Fan section Supply fan Door- right side Outward swing 24.5in. dd plenum, full width, M press Higher efficiency 4 Fan quantity Plenum fan Right side drive NEMA premium compliant ODP Voltage 460/3 NEMA motor hps only 10 max applied hp 1800 RPM Inverter balance with shaft grounding Side rectangular discharge Field provided VFD Performance Data - Performance Climate Changer (CSAA) Tags AHU-whse Unit level options Position Length (in) 142.631 Width (in) 140.500 Height (in) 107.500 Rigging weight (lb) 7400.8 Installed weight (lb) 8081.7 Roof curb weight (lb) 401.2 Actual airflow (cfm) 40000 Unit elevation (ft) 0.00 Shipping split 1 weight (lb) 3965.1 Shipping split 2 weight (lb) 3715.4 Fan section Position #3 Section length (in) 61.478 Section weight (lb) 3715.4 Fan airflow (cfm) 40000 Elevation (ft) 0.00 Overall ESP (in H2O) 2.000 Total static pressure (in H2O) 3.895 Maximum TSP @ 60 Hz (in H2O) 3.895 Fan pressure drop (in H2O) 2.319 Speed (rpm) 1752 Total brake horsepower (hp) 37.084 Unit static efficiency (%) 66.24 Motor hertz (Hz) 60 Discharge 1 side - airflow (cfm) 40000 Discharge 1 side - face velocity (ft/min) 1596 Discharge 1 side - pressure drop (in H2O) 0.319 Discharge 1 side - area (sq ft) 25.06 Coil section Position #2 Section length (in) 27.028 Amazon MEP Structural Design Amazon DVB1 March 17, 2020 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 28 of 54 Tags AHU-whse Section weight (lb) 1748.2 Coil performance airflow (cfm) 40000 Unit airflow (cfm) 40000 Coil face area (sq ft) 78.75 Coil face velocity (ft/min) 508 Air pressure drop (in H2O) 0.447 Coil section pressure drop (in H2O) 0.447 Coil rigging weight (lb) 730.4 Coil installed weight (lb) 1010.1 Top or single coil dry weight (lb) 365.2 Middle or bottom coil dry weight (lb) 365.2 Leaving dry bulb (F) 60.84 Leaving wet bulb (F) 59.44 Entering dry bulb (F) 80.40 Entering wet bulb (F) 70.80 Fluid type Water Coil fluid percentage (%) 100.00 Entering fluid temperature (F) 44.00 Leaving fluid temperature (F) 54.00 Fluid temperature rise (F) 10.00 Standard fluid flow rate (gpm) 308.71 Fluid pressure drop (ft H2O) 17.74 Fluid velocity (ft/s) 3.78 Fluid volume (gal) 33.45 Sensible capacity (MBh) 866.93 Total capacity (MBh) 1549.07 Air mixing section Position #1 Section length (in) 54.000 Section weight (lb) 2216.9 Opening 1 back - airflow (cfm) 40000 Opening 1 front - airflow (cfm) 40000 Opening 1 left - airflow (cfm) 20000 Opening 1 back - area (sq ft) 30.83 Opening 1 front - area (sq ft) 92.42 Opening 1 left - area (sq ft) 18.45 Opening 1 back - face velocity (ft/min) 1297 Opening 1 left - face velocity (ft/min) 1084 Opening 1 back - pressure drop (in H2O) 0.273 Opening 1 left - pressure drop (in H2O) 0.083 Opening 1 back total pressure drop (in H2O) 0.273 Opening 1 left side total pressure drop (in H2O) 0.083 Back hood pressure drop (in H2O) 0.220 Back hood area (sq ft) 54.54 Back inlet type Unducted Left side inlet type Ducted Greatest entry PD (in H2O) 0.493 Filter condition Mid-life Filter airflow (cfm) 40000 Filter area (sq ft) 85.56 Filter face velocity (ft/min) 468 Filter pressure drop (in H2O) 0.636 Total mixing section pressure drop (in H2O) 1.130 Front total pressure drop (in H2O) 0.000 Back total pressure drop (in H2O) 0.493 Top total pressure drop (in H2O) 0.000 Amazon MEP Structural Design Amazon DVB1 March 17, 2020 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 29 of 54 Tags AHU-whse Bottom total pressure drop (in H2O) 0.000 Right side total pressure drop (in H2O) 0.000 Left side total pressure drop (in H2O) 0.083 Amazon MEP Structural Design Amazon DVB1 March 17, 2020 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 30 of 54 Mechanical Specifications - Performance Climate Changer (CSAA) Item: B1 Qty: 1 Tag(s): AHU-whse GENERAL Outdoor air handling units will be shipped with all openings covered to protect unit interior from in-transit debris. Installing contractor is responsible for long term storage in accordance with the Installation, Operation, and Maintenance manual (CLCH-SVX07B-EN). Unit shall be UL and C-UL Listed. Supply fans within the scope of AHRI Standard 430 shall be certified in accordance with AHRI Standard 430. Unit sound performance data shall be provided using AHRI Standard 260 test methods and reported as sound power. Trane, in providing this program and data, does not certify or warrant NC levels. These levels are affected by factors specific to each application and/or installation and therefore unable to be predicted or certified by Trane. Refer to product data for specific fan footnote references. Unit Construction Outdoor unit roofs shall incorporate a standing seam on the exterior to ensure a rigid roof construction and prevent water infiltration . Roof assembly shall overhang all walls by 1.5 -inch minimum to prevent sheeting from roof to side panels . Rain gutters shall also be provided over all doors shorter than total unit height to direct rain away from the door assembly. Outdoor roofs shall be sloped, not less than 0.125 inches per foot, for water drainage. Where outdoor units are shipped in multiple sections, provide standing-seam joiners at each split with adhesive, hardware, and cover strips for field joining by the installing contractor. All unit panels shall be 2" solid, double-wall construction to facilitate cleaning of unit interior. Unit panels shall be provided with a mid-span, no-through-metal, internal thermal break. Casing thermal performance shall be such that under 55°F supply air temperature and design conditions on the exterior of the unit of 81°F dry bulb and 73°F wet bulb, condensation shall not form on the casing exterior. All outdoor AHU interior casing panels will be made of galvanized steel. Unit Paint External surface of unit casing will be coated with water-based polyurethane paint. Color to be standard "Slate Gray". Factory-painted units will be able to withstand a salt spray test in accordance with ASTM B117 for a minimum of 500 consecutive hours and shall meet the following requirements following the salt-spray test: - Mean scribe creepage rating of at least 6 per ASTM D1654 procedure A - Blister size no larger than #6 per ASTM D714 - Blister density no greater than Medium per ASTM D714 - No onset of red rust Casing Deflection The casing shall not exceed 0.0042 inch deflection per inch of panel span at 1.00 times design static pressure. Maximum design static shall not exceed +8 inches w.g. in all positive pressure sections and -8 inches w.g. in all negative pressure sections. Floor Construction The unit floor shall be of sufficient strength to support a 300.0 lb load during maintenance activities and shall deflect no more than 0.0042 inch per inch of panel span. Unit base Manufacturer to provide a full perimeter integral base frame for either ceiling suspension of units or to support and raise all sections of the unit for proper trapping. Indoor unit base frame will either be bolted construction or welded construction. All outdoor unit base frames shall be welded construction. For indoor units, refer to schedule for base height and construction type. Contractor will be responsible for providing a housekeep ing pad when unit base frame is not of sufficient height to properly trap unit. Unit base frames not constructed of galvanized steel shall be chemically cleaned and coated with both a rust-inhibiting primer and finished coat of rust-inhibiting enamel. Unit base height to be included in total height required for proper trap height. Amazon MEP Structural Design Amazon DVB1 March 17, 2020 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 31 of 54 Insulation Panel insulation shall provide a minimum thermal resistance (R) value of 13 ft²-h-ºF/Btu throughout the entire unit. Insulation shall completely fill the panel cavities in all directions so that no voids exist and settling of insulation is prevented. Panel insulation shall comply with NFPA 90A. Drain Pan In sections provided with a drain pan, the drain pan shall be designed in accordance with ASHRAE 62.1. To address indoor air quality (IAQ) the drain pan shall be sloped in two planes promoting positive drainage to eliminate stagnant water conditions. Drain pan shall be insulated, and of double wall construction. The outlet shall be the lowest point on the pan, and shall be of sufficient diameter to preclude drain pan overflow under normally expected operating conditions. All drain pans connections shall have a threaded connection, extending a minimum of 2-1/2" beyond the unit base, and shall be made from the same material as the drain pan. Drain pan located under a cooling coil shall be of sufficient size to collect all condensate produced from the coil. Refer to Product Data for specific information on which sections are supplied with a drain pan, the drain pan materi al and connection location. Access Door Construction Access doors shall be 2" double wall construction. Interior and exterior door panels shall be of the same construction as the interior and exterior wall panels respectively. All doors shall be provided with a thermal break construction of door panel and door frame. Gasketing shall be provided around the full perimeter of the doors to prevent air leakage. Surface mounted handles shall be provided to allow quick access to the interior of the functional section and to prevent through cabinet penetrations that could likely weaken the casing leakage and thermal performance. Handle hardware shall be designed to prevent unintended closure. Access doors shall be hinged and removable for quick easy access. Hinges shall be interchangeable with the door handle hardware to allow for alternating door swing in the field to minimize access interference due to unforeseen job site obstructions. Door handle hardware shall be adjustable and visually indicate locking position of door latch external to the section. Door hinges shall be galvanized. All doors shall be a minimum of 60" high when sufficient height is available or the maximum height allowed by the unit height. Door handles shall be provided for each latching point of the door necessary to maintain the specified air leakage integrity of the unit. Optionally for indoor AHUs and as standard on outdoor AHUs, outward swing doors are provided with a single handle linked to multiple latching points. An optional shatterpro of window shall be provided in access doors where indicated on the plans. Window shall either be single pane, or thermal dual pane, as defined on schedule. Window shall be capable of withstanding unit operating pressures and shall be safe for viewing UV -C lamps. Refer to Product Data for specific information on which sections are supplied with an access door, the door location, a single handle and a window. Factory-supplied Curb Outdoor AHU will be provided with a factory-supplied roof curb. Curb will be shipped to jobsite disassembled. Contractor will be responsible for assembly and mounting to roof structure per the Roof Curb Manual. Units with factory-supplied external piping cabinet(s), the factory-supplied curb will include a curb section for the pipe cabinet(s). Refer to the Roof Curb Detail drawing and Product Data section of submittal for height of factory -supplied roof curb(s). MIXING SECTION A mixing section shall be provided to support the damper assembly for outdoor, return, and/or exhaust ai r. Dampers Dampers shall modulate the volume of outdoor, return, or exhaust air. The dampers shall be of double -skin airfoil design with metal, compressible jamb seals and flexible blade-edge seals on all blades. The blades shall rotate on stainless-steel sleeve bearings. The dampers shall be rated for a maximum leakage rate of 3 cfm/ft² at 1 in. w.g. complying with ASHRAE 90.1 maximum damper leakage. All leakage testing and pressure ratings shall be based on AMCA Standard 500-D. Dampers may be arranged in a parallel or opposed-blade configuration. Inlet Hoods Inlet hoods are provided on the outside air openings and equipped with high performance moisture eliminators to minimize water carryover from the outside into the unit casing. Eliminators also perform the function of a bird screen to prevent nesting. Refer to the unit As-Built and Product Data section for specific information on which sections are supplied with inlet hood. Amazon MEP Structural Design Amazon DVB1 March 17, 2020 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 32 of 54 Dampers Dampers shall modulate the volume of outdoor, return, or exhaust air. The dampers shall be of double-skin airfoil design with metal, compressible jamb seals and flexible blade-edge seals on all blades. The blades shall rotate on stainless-steel sleeve bearings. The dampers shall be rated for a maximum leakage rate of 3 cfm/ft² at 1 in. w.g. complying with ASHRAE 90.1 maximum damper leakage. All leakage testing and pressure ratings shall be based on AMCA Standard 500-D. Dampers may be arranged in a parallel or opposed-blade configuration. Title 24 The following specifications apply only to units with outside air and return air dampers, with actuators. The 5 year warranty applies only to these items. This unit contains Economizer that meets or exceeds all mandatory requirements prescribed by Title 24, including but not limited to: - 5 yr parts only warranty - Successfully tested to 60,000 Actuations - Less than 10 cfm/sq.ft. of damper leakage at 1" WG per AMCA 500L Filters Mixing sections shall be provided with a filter rack as indicated in the Product Dat a and As-Built sections of the submittal. 2-inch pleated media filters made with 100% synthetic fibers that are continuously laminated to a supported steel -wire grid with water repellent adhesive shall be provided. Filters shall be capable of operating up to 625 fpm face velocity without loss of filter efficiency and holding capacity. The filters shall have a MERV 8 rating when tested in accordance with the ANSI/ASHRAE Standard 52.2. COIL SECTION WITH FACTORY INSTALLED COIL The coil section shall be provided complete with coil and coil holding frame. The coils shall be installed such that headers and return bends are enclosed by unit casings. If two or more cooling coils are stacked in the unit, an intermediate drain pan shall be installed between each coil and be of the same material as the primary drain pan. Like the primary drain pan, the intermediate drain pan shall be designed being of sufficient size to collect all condensation produced from the coil and sloped to promote positive drainage to eliminate stagnant water conditions. The intermediate pan shall begin at the leading face of the water -producing device and be of sufficient length extending downstream to prevent condensate from passing through the air stream of the lower coil. Intermediate d rain pan shall include downspouts to direct condensate to the primary drain pan. The outlet shall be located at the lowest point of the pan and shall be sufficient diameter to preclude drain pan overflow under any normally expected operating condition. Coil with Inspection The coil section shall include an inspection section complete with a double-wall, removable door downstream of the coil for inspection, cleaning, and maintenance. Interior and exterior door panels shall be of the same construction as t he interior and exterior wall panels, respectively. All doors shall be provided with a thermal break construction of door panel and door frame. In lieu of a door, an easily removable service panel shall be provided in sections as specified, to facilitate access to unit for periodic servicing, or for removal and replacement of coils. Removal of service panel will not impact the structural integrity of the unit. Casing penetrations supplied for hydronic drain and vents. Piping contractor shall provide exte nded piping. Water Coils (UP, WP, UW, UU, UA, 3W, 3U, W, 5W, 5A, WD, 5D, D1, D2, P, or TT) The coils shall have aluminum fins and seamless copper tubes. Copper fins may be applied to coils with 5/8 -inch tubes. Fins shall have collars drawn, belled, and firmly bonded to tubes by mechanical expansion of the tubes. The coil casing may be galvanized or stainless steel. Refer to the Product Data section of the submittal for the coil casing material. The coils shall be proof-tested to 300 psig and leak-tested under water to 200 psig. Coils containing water or ethylene glycol are certified in accordance with the AHRI Forced-Circulation Air-Cooling and Air-Heating Coils Certification Program which is based on AHRI Standard 410 within the Range of Standard Rating Conditions listed in Table 1 of the Standard. Certified units may be found in the AHRI Directory at www.ahridirectory.org. Propylene glycol and calcium chloride, or mixtures thereof, are outside the scope of AHRI Standard 410 and, therefore, do not require AHRI 410 rating or certification. Coil connections are constructed of cast iron with female connections, steel block with female connections or steel pipe Amazon MEP Structural Design Amazon DVB1 March 17, 2020 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 33 of 54 with male connections. Type P or TT coil connections do not extend out of unit casing. All other water coil types have connections that extend out beyond unit casing. Headers on downstream coil bank of staggered coil sections do not extend beyond the unit casing and must be completed by the on-site piping contractor. Tubes are 1/2" [13 mm] OD 0.016" [0.406 mm] thick copper. DIRECT-DRIVE PLENUM FAN SECTION The fan type shall be provided as required for stable operation and optimum energy efficiency. The fan shall be a single-width, single-inlet, multiblade-type direct-drive plenum fan. Motor bearing life of the direct-drive plenum fan shall be not less than L-10 250,000 hrs. Refer to the Product Data section for fan quantity and number of blades selected within each unit. Fans shall be certified as complying with AHRI Standard 430 for airflow per formance. Fans shall be tested and rated in-accordance with AHRI Standard 260 for sound performance. Fans that are selected with inverter balancing shall first be dynamically balanced at design RPM. The fans then will be checked in the factory from 25% to 100% of design RPM to insure they are operating within vibration tolerance specifications, and that there are no resonant frequency issues throughout this operating range. Inverter balancing that requires lockout frequencies inputted into a variable frequency drive to in order to bypass resonant frequencies shall not be acceptable. If supplied in this manner by the unit manufacturer, the contractor will be responsible for rebalancing in the field after unit installation. Fans selected with inverter balancing shall have a maintenance free grounding assembly installed on the fan motor to discharge both static and induced shaft currents to ground. On units supplied with plenum or motorized impeller fans, expanded metal door guard(s) shall be supplied on the access door(s) to the fan and those downstream access door(s) where unintended access to the plenum or motorized impeller fan could occur. Door guard is intended to deter unauthorized entry and incidental contact with rotating components. Refer to the Product Data section for fans with access door guard(s). Motor Frame The motor shall be mounted integral to the isolated fan assembly and furnished by the unit manufacturer. The motor is mounted inside the unit casing on an adjustable base to permit adjustmen t of drive belt tension (not applicable for direct drive plenum fans). The motor shall meet or exceed all NEMA Standards Publication MG 1 requirements and comply with NEMA Premium efficiency levels when applicable except for fractional horsepower motors which are not covered by the NEMA classification. The motor shall be T-frame, squirrel cage with size, type, and electrical characteristics as shown on the equipment schedule. Refer to the Product Data section for selected fan motors within each unit. Two-Inch Spring Isolators Direct-drive fan and motor assemblies shall be internally isolated from the unit casing with 2-inch (50.8 mm) deflection spring isolators. The isolation system shall be designed to resist loads produced by external forces, such as earthquakes, and conform to the current IBC seismic requirements. Lifting Instructions The air handling units must be rigged, lifted, and installed in strict accordance with the Installation, Operation, and Maintenance manual (CLCH-SVX07G-EN). The units are also to be installed in strict accordance with the specifications. Units may be shipped fully assembled or disassembled to the minimum functional section size in accordance with shipping and job site requirements. Outdoor units shall be shipped on 6" integral base frame for the purpose of mounting units on a roof curb or field-supplied pier support system. Refer to the Product Data section for type of the base frame provided (for roof curb or pier-mount). All units will be shipped with an integral base frame designed with the necessary number of lift points for safe installation. All lifting lugs are to be utilized during lift. The lift points will be designed to accept standard rigging d evices and be removable after installation. Units shipped in sections will have a minimum of four points of lift. Amazon MEP Structural Design Amazon DVB1 March 17, 2020 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 34 of 54 As-Built - Performance Climate Changer (CSAA) Item: B1 Qty: 1 Tag(s): AHU-whse OPENING AND DIMENSIONS MAY VARY FROM CONTRACT DOCUMENTS / RETURN OF APPROVED DRAWINGS CONSTITUTES ACCEPTANCE OF THESE VARIANCES / NOT TO SCALE Unit size: 80Product group: Outdoor unitIntegral base frame: 6in. integral base framePaint: Slate grayJob Name: Actual airflow: 40000 cfmSales Office: Unit Casing: 2in Double Wall Foam Proposal Number: Rigging/Installed Weight: 7400.8 lb/ 8081.7 lbPerformance Climate ChangerAir Handlers9 5/844 45 1/813 34 1/420"10"23"7 1/4126 140 1/21234566 15 7/879 1/245 1/8761 1/2Ship Split3715 lbs81 1/8Ship Split3965 lbs142 5/8107 1/21 2 3 4 5 67 Opening left82.000 x 44.000Plenum fan - 24.5in. ddplenum, full width, M pressSupply fan 10 hp 460/3NoneCooling coil - 4 Coil typeUUDamper left-parallel blade88.000 x 34.250Damper back-parallelblade40.000 x 123.000Hood backFlat filters - Doors20 width x 61 height 10 width x 61 height 23 width x 97 height For maneuvering purposes, include 1.125 inches to each ship split length for overlapping panel flange. Flange will not add to overall installed unit length shown. Amazon MEP Structural Design Amazon DVB1 March 17, 2020 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 35 of 54 As-Built - Performance Climate Changer (CSAA) Item: B1 Qty: 1 Tag(s): AHU-whse OPENING AND DIMENSIONS MAY VARY FROM CONTRACT DOCUMENTS / RETURN OF APPROVED DRAWINGS CONSTITUTES ACCEPTANCE OF THESE VARIANCES / NOT TO SCALE Unit size: 80 Product group: Outdoor unit Integral base frame: 6in. integral base frame Paint: Slate gray Job Name: Actual airflow: 40000 cfm Sales Office: Unit Casing: 2in Double Wall Foam Proposal Number: Rigging/Installed Weight: 7400.8 lb/ 8081.7 lb Performance Climate Changer Air Handlers Pos # 3 2 1 Module Fan section Coil section Air mixing section Length 61 1/2 27 1/8 54 Weight 3715.41 1748.25 2216.85 Installed Unit Weight 7680.51 lbs 3 2 1 140 1/2Basic Overall Plan View: Top - Measurements in inches S2 S1 6 3 2 1 142 5/8 111 1/8For maneuvering purposes, include 1.125 inches to each ship split length for overlapping panel flange. Flange will not add to overall installed unit length shown. Amazon MEP Structural Design Amazon DVB1 March 17, 2020 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 36 of 54 As-Built - Performance Climate Changer (CSAA) Item: B1 Qty: 1 Tag(s): AHU-whse OPENING AND DIMENSIONS MAY VARY FROM CONTRACT DOCUMENTS / RETURN OF APPROVED DRAWINGS CONSTITUTES ACCEPTANCE OF THESE VARIANCES / NOT TO SCALE Unit size: 80 Product group: Outdoor unit Integral base frame: 6in. integral base frame Paint: Slate gray Job Name: Actual airflow: 40000 cfm Sales Office: Unit Casing: 2in Double Wall Foam Proposal Number: Rigging/Installed Weight: 7400.8 lb/ 8081.7 lb Performance Climate Changer Air Handlers 3 2 1 61 1/2 27 1/8 54 140 1/2Right Side of Unit Detailed Plan View: Top - Measurements in inches 3 2 1 30 1/8 61 1/2 27 1/8 54 3.563" dia elec. conn.(NEMA) 135 1/2 140 1/2Left Side of Unit Detailed Plan View: Bottom - Measurements in inches Amazon MEP Structural Design Amazon DVB1 March 17, 2020 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 37 of 54 As-Built - Performance Climate Changer (CSAA) Item: B1 Qty: 1 Tag(s): AHU-whse OPENING AND DIMENSIONS MAY VARY FROM CONTRACT DOCUMENTS / RETURN OF APPROVED DRAWINGS CONSTITUTES ACCEPTANCE OF THESE VARIANCES / NOT TO SCALE Unit size: 80 Product group: Outdoor unit Integral base frame: 6in. integral base frame Paint: Slate gray Job Name: Actual airflow: 40000 cfm Sales Office: Unit Casing: 2in Double Wall Foam Proposal Number: Rigging/Installed Weight: 7400.8 lb/ 8081.7 lb Performance Climate Changer Air Handlers 321 44 34 1/482 88 8 7 1/2 13 61 1/227 1/8 54 1.5" N.P.T.E 6 1/86 13 1/4 15 3/4107 1/2Detailed Elevation View: Left - Measurements in inches 6 7 5/87 3/4 15 7/860 1/297 1/479 1/23 2 1 3 3 3/8 2 1/8 54 20" 10" 23"45 1/8142 5/8 111 1/8 Amazon MEP Structural Design Amazon DVB1 March 17, 2020 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 38 of 54 As-Built - Performance Climate Changer (CSAA) Item: B1 Qty: 1 Tag(s): AHU-whse OPENING AND DIMENSIONS MAY VARY FROM CONTRACT DOCUMENTS / RETURN OF APPROVED DRAWINGS CONSTITUTES ACCEPTANCE OF THESE VARIANCES / NOT TO SCALE Unit size: 80 Product group: Outdoor unit Integral base frame: 6in. integral base frame Paint: Slate gray Job Name: Actual airflow: 40000 cfm Sales Office: Unit Casing: 2in Double Wall Foam Proposal Number: Rigging/Installed Weight: 7400.8 lb/ 8081.7 lb Performance Climate Changer Air Handlers 1 143 1/2126 3 5/879 1/21 1/2 7 1/4 140 1/2 6 15 7/8107 1/2Detailed Elevation View: Back - Measurements in inches 111 1/83 143 1/23 5/86 Detailed Elevation View: Front - Measurements in inches Amazon MEP Structural Design Amazon DVB1 March 17, 2020 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 39 of 54 As-Built - Performance Climate Changer (CSAA) Item: B1 Qty: 1 Tag(s): AHU-whse OPENING AND DIMENSIONS MAY VARY FROM CONTRACT DOCUMENTS / RETURN OF APPROVED DRAWINGS CONSTITUTES ACCEPTANCE OF THESE VARIANCES / NOT TO SCALE Unit size: 80Product group: Outdoor unitIntegral base frame: 6in. integral base framePaint: Slate grayJob Name: Actual airflow: 40000 cfmSales Office: Unit Casing: 2in Double Wall Foam Proposal Number: Rigging/Installed Weight: 7400.8 lb/ 8081.7 lbPerformance Climate ChangerAir Handlers107 1/232161 1/227 1/854 142 5/8111 1/8NPTI : National Pipe Thread Internal ConnectionNPTE : National Pipe Thread External Connection Amazon MEP Structural Design Amazon DVB1 March 17, 2020 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 40 of 54 As-Built - Performance Climate Changer (CSAA) Item: B1 Qty: 1 Tag(s): AHU-whse OPENING AND DIMENSIONS MAY VARY FROM CONTRACT DOCUMENTS / RETURN OF APPROVED DRAWINGS CONSTITUTES ACCEPTANCE OF THESE VARIANCES / NOT TO SCALE Unit size: 80Product group: Outdoor unitIntegral base frame: 6in. integral base framePaint: Slate grayJob Name: Actual airflow: 40000 cfmSales Office: Unit Casing: 2in Double Wall Foam Proposal Number: Rigging/Installed Weight: 7400.8 lb/ 8081.7 lbPerformance Climate ChangerAir Handlers3219 1/45 61 1/227 1/854 2.5" (NPTE) Return2.5" (NPTE) Supply3/8" (NPTI) Vent3/8" drain (NPTI)31 1/234 5/878 3/481 7/8107 1/2142 5/8111 1/8Coil connection view: Left - Measurements in inchesNPTI : National Pipe Thread Internal ConnectionNPTE : National Pipe Thread External Connection Amazon MEP Structural Design Amazon DVB1 March 17, 2020 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 41 of 54 As-Built - Performance Climate Changer (CSAA) Item: B1 Qty: 1 Tag(s): AHU-whse OPENING AND DIMENSIONS MAY VARY FROM CONTRACT DOCUMENTS / RETURN OF APPROVED DRAWINGS CONSTITUTES ACCEPTANCE OF THESE VARIANCES / NOT TO SCALE Unit size: 80Product group: Outdoor unitIntegral base frame: 6in. integral base framePaint: Slate grayJob Name: Actual airflow: 40000 cfmSales Office: Unit Casing: 2in Double Wall Foam Proposal Number: Rigging/Installed Weight: 7400.8 lb/ 8081.7 lbPerformance Climate ChangerAir Handlers32193 156 156 11 7/856 Basic Service Clearance - Plan - Measurements in inches