Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILD* CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: LE CLERE RESIDENCE Builder Name: Street: 163 NETTLES Permit Office: ST LUCIE COUNTY City, State, Zip: JENSEN BEACH, FL, Permit Number: Owner. Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County. St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2291.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Inl Insul, Exterior R=4.1 2211.30 ft b. Frame - Wood, Exterior R=19.0 80.00 fF 3. Number of units, if multiple family 1 c. N/A R= R 4. Number of Bedrooms 3 d. N/A R= R' 10. Ceding Types (1799.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 1799.00 ff 6. Conditioned floor area above grade (ft') 1799 b. N/A R= ft' Conditioned floor area below grade (W) 0 c. N/A R= ft' 11. Ducts R R' 7. Windows(341.1 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 150 a. U-Factor. Dbl,U=0.29 214A2R' I� REVIEWED FOR SHGC: SHGC=0.21 b. U-Factor. Dbl, U=0.26 80.00 ft' ��q II,,��,r� /�++�J� 12. Cooling syst, CDE COIYrI'C95N6"ANG&ncy SHGC: SHGC=0.23 a. Central Unit 6 600 COMY ST. LUCIE c. U-Factor. Dbl,U=0.31 40.00ft- SHGC: SHGC=0.19 13. Heating systems BOCOBtu/hr Efficiency d. U-Factor: other (see details) 6.67 ft- a. Electric Strip Heat 27.0 COP:1.00 SHGC: other (see details) Area Weighted Average Overhang Depth: 1.576 ft. Area Weighted Average SHGC: 0.213 14. Hot water systems � qq''�� C0C.i{p a. Electric Tankless L'' fle 11 gallons S. Floor Types (1799.0 sqft.) Insulation Area--- EF: 0.990 a. Raised Floor R=30.0 909.00 ft' b. Conservation features b. Slab -On -Grade Edge Insulation R=0.0 890.00 ft- None c. N/A R= W 15. Credits None Glass/Floor Area: 0.190 Total Proposed Modified Loads: 67.02 PASS Total Baseline Loads: 70.51 1 hereby certify that the plans and specifications covered by Review of the plans and FTtifi STA this calculation are in compliance with the Florida Energy specifications covered by this v0 Code. calculation indicates compliance with the Florida Energy Code. � r°n, w •.,;.`-.:�°.,,.��;, O PREPAR BY: Before construction is completed 1,( a DATE: ) t . this building will be inspected for c9 ri( a compliance with Section 553.908 • ° - a I hereby certify that this building, as designed, is in compliance Flonda Statutes. 5� COD with the Florida Energy Code. WE OWNERIAGENT' - f �� �� BUILDING OFFICIAL: DATE: t DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 1216120191:42 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: LE CLERE RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Condilioned Area: 1799 Lot # Owner Name: Total Stories: 1 BlocMSubdivision: # of Units: 1 Worst Case: No PlatBcok Builder Name: Rotate Angle: 0 Street: 163 NETTLES Permit Office: ST LUCIE COUNTY Cross Ventilation: No County. St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: JENSEN BEACH, Famiy Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daly Temp V Design Location TMYSite 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1799 14392 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 WIC3 30 240 No 0 1 Yes Yes Yes 2 BEDROOM 3 159 1272 No 0 1 1 Yes Yes Yes 3 BATH 3 51 40B No 0 1 Yes Yes Yes 4 HALLWAY 93 744 No 0 1 Yes Yes Yes 5 STAIRS UP 48 394 No 0 1 Yes Yes Yes 6 BEDROOM 2 134 1072 No 0 1 1 Yes Yes Yes 7 W1D 16 128 No 0 1 No Yes Yes 8 CHSE 8 64 No 0 1 No Yes Yes 9 CLST 2 14 112 No 0 1 Yes Yes Yes 10 MASTER SEDROO 170 1360 No 0 1 1 Yes Yes Yes 11 MWIC 56 448 No 0 1 Yes Yes Yes 12 M BATH 130 1040 No 0 1 Yes Yes Yes 13 LIVING 426 3404 No 0 1 Yes Yes Yes 14 KITCHEN 169 1352 Yes 0 1 Yes Yes Yes 15 BATH 75 600 No 0 1 Yes Yes Yes 16 STORAGE 24 192 No 0 1 Yes Yes Yes 17 CLST 26 208 No 0 1 No Yes Yes 18 FOYER 80 640 No 0 1 Yes Yes Yes 19 DEN 90 720 No 0 1 Yes Yes Yes 12/620191:42 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Raised Flow WIC 3 — — 30 ft' 30 1 0 0 2 Raised Floor BEDROOM 3 _ — 159 tt' 30 1 0 0 3 Raised Floor BATH 3 — — 51 ft' 30 1 0 0 4 Raised Floor HALLWAY — __ 93 ft' 30 1 0 0 5 Raised Flow STAIRS UP — — 48 ft' 30 1 0 0 6 Raised Floor BEDROOM 2 — _ 134 it' 30 1 0 0 7 Raised Floor W/D — — 16 ft' 30 1 0 0 8 Raised Floor CHSE — — 8ft' 30 1 0 0 9 Raised Floor CLST 2 — —_ 14 ft' 30 1 0 0 162aised Floor MASTER BEDRO — __ 170 ft' 30 1 0 0 11Raised Floor M WIC — — 56 ft' 30 1 0 0 17Raised Floor M BATH — _ 130 it' 30 1 0 0 133IabGnGrade Edge Insulation LIVING 63.4ft 0 426 ft' — 1 0 0 14SIabOnGrade Edge Insulation KITCHEN 9 ft 0 169 ft' _ 1 0 0 15SIab-OnGrade Edge Insulation BATH 19 It 0 75 ft' — 1 0 0 16Slab-OnGrade Edge Insulation STORAGE 611 0 24 ft' — 1 0 0 17SIab-OnGrade Edge Insulation CLST 1 ft 0 26 ft' — 1 0 0 18SIab-OnGrade Edge Insulation FOYER 14 ft 0 80 ft. — 1 0 0 1 gSlab-OnGrade Edge Insulation DEN 29.6 it 0 90 ft. — 1 0 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1984 ft' ow Light N 0.2 No 0.9 No 20 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1883 ft' N N 121620191:42 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Unvented) WIC 0 Blown 30 ft- 0.1 Wood 2 Under Attic (Unvented) BEDROOM 0 Blown 159 ft' 0.1 Wood 3 Under Attic (Unvented) BATH 3 0 Blown 51 ft' 0.1 Wood 4 Under Attic (Unvented) HALLWAY 0 Blown 93 ft' 0.1 Wood 5 Under Attic (Unvented) STAIRS UP 0 Blown 48 ft' 0.1 Wood 6 Under Attic (Unvented) BEDROOM 0 Blown 134 ft' 0.1 Wood 7 Under Attic (Unvented) W/D 0 Blown 16 ft- 0.1 Wood 8 Under Attic (Unvented) CHSE 0 Blown 8ft. 0.1 Wood 9 Under Attic (Unvented) CLST 2 0 Blown 14 ft' 0.1 Wood 10 Under Attic (Unvented) MASTER BEDRO 0 Blown 170 ft- 0.1 Wood 11 Under Attic (Unvented) M WIC 0 Blown 56 ft' 0.1 Wood 12 Under Attic (Unvented) MBATH 0 Blown 130 ft- 0.1 Wood 13 Under Attic (Unvented) LIVING 0 Blown 426 ft- 0.1 Wood 14 Under Attic (Unvented) KITCHEN 0 Blown 169W 0.1 Wood 15 Under Attic (Unvented) BATH 0 Blown 75 ft' 0.1 Wood 16 Under Attic (Unvented) STORAGE 0 Blown 24 ft- 0.1 Wood 17 Under Attic(Unvented) CLST 0 Blown 26 ft- 0.1 Wood 18 Under Attic (Unvented) FOYER 0 Blown soft' 0.1 Wood 19 Under Attic (Unvented) DEN 0 Blown 90 ft' 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1 E Exterior Concrete Block- Int Insul WIC 3 4.1 6 0 8 0 48.0 ft- 0 0 0.2 0 _ 2 NW Exterior Concrete Block -Int Insul WIC 4.1 11 8 8 0 93.3 ft' 0 0 0.2 0 _ 3 E Exterior Concrete Block- Int InsuBEDROOM 3 4.1 10 0 8 0 80.0 ft. 0 0 0.2 0 4 NW Exterior Concrete Block - Int Insrd3EDROOM 3 4.1 8 1 8 0 64.7 ft` 0 0 0.2 0 5 W Exterior Concrete Block- Int Insul BATH 3 4.1 7 0 8 0 56.0 fK 0 0 0.2 0 6 NW Exterior Concrete Block-Int Insul BATH3 4.1 6 8 8 0 53.3 fP 0 0 0.2 0 _ 7 W Exterior Concrete Black- Int Insul HALLWAY 4.1 4 0 8 0 32.0 ft' 0 0 0.2 0 8 W Exterior Concrete Block- Int InsuISTAIRS UP 4.1 12 0 8 0 96.0 ft. 0 0 0.2 0 _ 9 E Exterior Concrete Block- Int InsuBEDROOM 2 4.1 10 0 8 0 80.0 ft' 0 0 0.2 0 _ 10 E Exterior Concrete Block- Int Insul CLST 2 4.1 2 0 8 0 16.0 ft' 0 0 0.2 0 11 E Exterior Concrete Block- Int InsuMASTER BE 4.1 12 0 8 0 96.0 ft' 0 0 0.2 0 _ 12 S Exterior Concrete Block- Int InsuMASTER BE 4.1 11 0 8 0 88.0 ft- 0 0 0.2 0 _ 13 W Exterior Concrete Block- Int Insul M WIC 4.1 7 0 8 0 56.0 ft- 0 0 0.2 0 14 E Exterior Frame - Wood M BATH 19 8 0 8 0 64.0 ft- 0 0.1 0.2 0 15 BE Exterior Concrete Block- Int Insul M BATH 4.1 13 11 8 0 111.3 ft' 0 0 0.2 0 16 W Exterior Concrete Block- Int Insul M BATH 4.1 14 0 8 0 112.0 ft' 0 0 0.2 0 _ 17 E Exterior Concrete Block- Int Insul LIVING 4.1 25 0 8 0 200.0 ft' 0 0 0.2 0 18 W Exterior Concrete Block - Int Insul LIVING 4.1 12 0 8 0 96.0 ft- 0 0 0.2 0 _ 19 NW Exterior Concrete Block - Int Insul LIVING 4.1 26 5 8 0 211.3 ft' 0 0 0.2 0 20 E Exterior Concrete Block- Int Insul KITCHEN 4.1 9 0 8 0 72.0 ft' 0 0 0.2 0 21 E Exterior Concrete Block- Int Insul BATH 4.1 6 0 8 0 48.0 fR 0 0 0.2 0 12/6/20191:42 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 4 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 22 S Exterior Concrete Block- Int Insul BATH 4.1 13 0 8 0 104.0 ft' 0 0 0.2 0 23 W Exterior Concrete Block- Int Insul STORAGE 4.1 6 0 8 0 48.0 ft' 0 0 0.2 0 24 E Exterior Concrete Block- Int Insul FOYER 4.1 6 0 8 0 48.0 ft' 0 0 0.2 0 25 W Exterior Concrete Block- Int Insul FOYER 4.1 8 0 8 0 64.0 ft' 0 0 0.2 0 26 E Exterior Concrete Block- Int Insul DEN 4.1 6 0 8 0 48.0 ft' 0 0 0.2 0 27 BE Exterior Concrete Block- Int Insul DEN 4.1 11 8 8 0 93.3 ft- 0 0 0.2 0 28 W Exterior Concrete Block- Int Insul DEN 4.1 12 0 8 0 96.0 ft' 0 0 0.2 0 29 E Exterior Frame -Wood MASTER BE 19 2 0 8 0 16.0 ft' 0 0.1 0.2 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Insulated FOYER None .39 3 6 8 20 ft' 2 W Insulated FOYER None .39 3 6 8 20 ft' WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E 3 Vinyl Low-E Double Yes 0.29 0.21 N 10.0 fP 0 it 10 in 0 ft 5 in None None 2 NW 4 Vinyl Low-E Double Yes 0.29 0.21 N 15.0 fF 0 it 10 in 0 it 6 in None None 3 NW 6 Vinyl Low-E Double Yes 0.29 0.21 N 4.0 ft' 0 it 10 in Off Sin None None 4 W 7 Vinyl Low-E Double Yes 0.29 0.21 N 10.0112 0 ft 10 in 0 ft 51n None None 5 W 8 Vinyl Low-E Double Yes 0.29 0.21 N 10.0 ft' 0 it 10 in 0 ft 5 in None None 6 E 9 Vinyl Low-E Double Yes 0.29 0.21 N 15.0 ft' 0 ft 10 in 0 ft 5 in None None 7 E 11 Vinyl Low-E Double Yes 0.29 0.21 N 15.0 flz 0 ft 10 in 0It 51n None None 8 S 12 Vinyl Low-E Double Yes 0.31 0.19 N 40.0 ft' 7 ft 2 In 0 ft 4 in None None 9 BE 15 Vinyl Low-E Double Yes 0.29 0.21 N 10.0 ft' 0 ft 10 in 0 ft 6 in None None 10 SE 15 Vinyl Low-E Double Yes 0.29 0.21 N 10.0 ft' 0 ft 10 in 0 ft 6 in None None 11 W 18 Vinyl La E Double Yes 0.29 0.21 N 20.0 ft' 0 ft 10 In 10 ft 0 in None None 12 W 18 Vinyl Low-E Double Yes 0.26 0.23 N 20.0 ft' 0 it 10 in 10 ft 0 in None None 13 NW 19 Vinyl Low-E Double Yes 0.29 0.21 N 10.0 ft' 0 ft 10 in 10 ft 0 in None None 14 NW 19 Vinyl Low-E Double Yes 0.29 0.21 N 20.0 ft' 0 ft 10 in 10 ft 0 in None None 15 NW 19 Vinyl Low-E Double Yes 0.26 0.23 N 60.0 ft' 0 ft 10 in 10 ft 0 in None None 16 E 17 Vinyl Low-E Double Yes 0.29 0.21 N 20.0 ft' 0 ft 10 in 10 ft 0 in None None 17 E 20 Vinyl Low-E Double Yes 0.29 0.21 N 6.0 ft' 0 ft 10 In 10 ft 0 In None None 18 E 21 Vinyl Low-E Double Yes 0.29 0.21 N 4.0 ft' 0 ft 10 in 10 ft 0 In None None 19 W 25 Vinyl Low-E Double Yes 0.24 0.23 N 6.7 ft' 0 it 10 in 10 it 0 in None None 20 BE 27 Vinyl Low-E Double Yes 0.29 0.21 N 10.0 ft' 0 H 10 in 10 ft 0 in None None 21 SE 27 Vinyl Low-E Double Yes 0.29 0.21 N 10.4 ft' 0 ft 10 in 10 it 0 in None None 22 W 28 Vinyl Low-E Double Yes 0.29 0.21 N 15.0 ft' 0 ft 10 in 10 ft 0 in None None 12/62019 1:42 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1678.6 92.15 173.31 .1233 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 27 kBtulhr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 16 36 kBtumr 1080 cfm 0.8 1 Sys#1 HOT WATERSYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric Tandess Exterior 0.99 1 gal 55.1 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft' DUCTS —Supply— # Location R-Value Area —Return Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT ON RLF HVAC# Heat Cool 1 Attic 6 150 ft' Attic 15 ft' Default Leakage Attic (Default) c(Default) c 1 1 TEMPERATURES Programable Thermostat: N [rX'J Jan Feb Vening Jan Feb [X] Marf Mar Cfreiling Fans:Cooling 4Aug rr Oct r7('� 4ay frXr [t Apr [ May [ Jun [ ] Jul [XJ Aug [ Sep [)� OctO t [XJ Nov Dec Dec 12/620191:42 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 60 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thlclmess Furniture Fraction Space Defauh(B lbs/sq.ft. 0 fl- Oft 0.3 WIC 3 Defauft(8 lbs/sq.ft. IF ft 0.3 BEDROOM 3 Defauft(8lbs/sq.ft. ft' ft 0.3 BATH 3 Defauft(8 lbs/sq.ft. ft' ft 0.3 HALLWAY Defauft(8 lbs/sq.ft. ft' ft 0.3 STAIRS UP Defauft(8 lbs/sq.ft. ft' ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft' ft 0.3 W/D Defauft(8 lbs/sq.ft. ft' ft 0.3 CHSE Defauft(8 lbsfsq.ft. IF ft 0.3 CLST 2 Defauft(8 lbsisq.ft. ft- ft 0.3 MASTER BEDROO Defauft(81bs/sq.ft. ft- ft 0.3 M WIC Defauft(8 lbs/sq.ft. fP ft 0.3 M BATH Defauft(8 lbs/sq.ft. fP ft 0.3 LIVING Defauft(8 lbs/sq.ft. ft' ft 0.3 KITCHEN DefauftS lbs/sq.ft. ft' ft 0.3 BATH Defauft(8lbs/sq.ft. ft' ft 0.3 STORAGE Defauft(8 lbs/sq.ft. ft' ft 0.3 CLST Defauft(8 lbs/sq.ft. ft- ft 0.3 FOYER Defauft(8 lbs/s.ft. fit ft 0.3 DEN 12/620191:42 PM EnergyGauge® USA 6.0.02 (Rev. 1) - RaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: LE CLERE RESIDENCE Builder Name: Street: 163 NETTLES Permit Office: ST LUCIE COUNTY City, State, Zip: JENSEN BEACH, FL, Permit Number: Y Owner. Jurisdiction: ST LUCIE COUNTY U w Design Location: FL, Fort Pierce x U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERI General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed, shall be aligned with the air barrier. Access openings, drop dawn stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed, shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be Installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be Insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity Insulation shall be Installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be In contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottorr to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crewlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on Installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures Installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring a plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or airsealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed J sprinklers in a manner that Is recommended by the manufacturer. Caulldng or other adhesive sealants shall not be used to fill voids between fire sprinlder cover plates and walls or ceilings. I a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 12020191:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX' = 95 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 36.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Groundiwater source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1799 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.284 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.213 14. Heating system: Capacity 27.0 c) Area 7c. 341.1 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 30.0 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.99 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. 19.0 e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatReO/o B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 0.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat No 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: ` L/ / Date: Z 3 J f Address of New Home: 163 NETTLES City/FL Zip: JENSEN BEACH. FL 12/6120191:43:45 PM EnergyGaugeO USA 6.0.04 (Rev. 1) - RaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1