Loading...
HomeMy WebLinkAboutEnergy Codet R�visr 2- s-zit Q aoml OoTO FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTII Florida Department of Business and Professional Regulation - Residential Perf rmance Method Project Name: 18601 Tranquility Base Lane (r) Builder Name: Mike DiFrancesco Street: 18601 Tranquility Base lane Permit Office: St Lucie County Gtity, State, Zip: Fort Pierce, FL, 34945 Permit Number. er. Jurisdiction: 611000 � gn Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or erdsting New (From Plans) 9. Wall Types (3391.7 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block- Polystyrene Bead A =O.o 2803.30 tle b. Frame - Wood, Adjacent R=13.0 588.33 fle 3. Number of units, If multiple family 1 c. WA R= ffe 4. Number of Bedrooms 3 d. WA R= ft2 10. Ceiling Types (3751.0 sgft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 3751.00IF 6. Conditioned floor area above grade (fit") 3751 b. WA R= fI Conditioned floor area below grade life) 0 o. WA R= file 11. Ducts R fP 7. Wmdows(590.4 sgfL) Description Area a. Sup: Attic, Ret: Attic, AH: Garage 6 281 a. U-Factor: Dbl, U=0.28 19525 fP b. Sup: Attic, Ret: Attic, AH: Bedrooms 6 265 SHGC: SHGC=021 b. U-Factor: Dbl, U=029 158.44 f[e 12. Cooling systems kBh to Efficiency SHGC: SHGC=0.21 a. Central Unit b. Central Unit 29.6 SEER:17.00 24.4 SEER:17.00 c. U-Factor. Dbl, U=0.33 96.00 ft' SHGC: SHGC=021 13. Heading systems kBhft Efficiency d. U-Factor. other (see details) 140.66 fP a. Electric Strip Heat 26.0 COP:1.00 SHGC: other (see details) b. Electric Strip Heat 16.0 COP:1.00 Area Weighted Average Overhang Depth: 9.498 fL Area Weighted Average SHGC: 0212 14. Hot water systems a. Electric Tankless Cap:1gallons 8. Floor Types (3751.0 sgft) Insulation Area EF: 0:980:0.980 a. Slab -On -Grade Edge Insulation R=0.0 3751.00fN b. Conservation features b. NIA R= fP None c. WA R= fP 15. Credits Pstat Glass/Floor Area: 0.157 Total Proposed Modified Loads: 112.98 7TASS Total Baseline Loads: 119.03 1 hereby certify that the plans and specifications covered by Review of the plans and OIT13E 5TgT� this calculation are in compliance with the F arida Energy specifications covered by this Code. calculation indicates complianceo-'� )'.'�•4 {O with the Florida Energy Code. rn„W, :v „ PREPARED BY: Before construction is completed DATE: Z' i �� y`� this building will be inspected for compliance with Section 553.W8 , I hereby certify that this building, as designed, is in compliance Energy Code. Florida Statutes. ♦Y Jet COO with the Florida //%% WE OWNER/AGENT: ' %c F( C2 )9 - BUILDING OFFICIAL: DATE: Z DATE: - - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordancewith R402.4.1.1 envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 2142020 7:19 PM EnergyGaugeO USA 6.0.02 (Rev.1) - FlaRes2017 FBC 6th Edition (2017) ialifies as id this project requires an COPY Page 1 of 5 t:npm'Rdf1.-rw9f17 INPUT Sl1MMORY CHECKLIST REPORT PROJECT Title: 18601 Tranquility Base Lane (r Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 3751 Lot 9 Owner Name: Total Stories: 1 Block/SubdWi n: 9 of Unds: 1 Worst Case: No PlatBook: Builder Name: Mike DiFranoesoo Rotate Angle: 0 Street 18601 Tranquility Base L permit Office: St Lucie County Cross Ventilation: County: St. Lucie Jurisdiction: 611000 Whole House Fan: City, State, Zip Fort Pierce , `,Family Type: Single-family FL, 34945 New/Existing: New (From Plans) Comment: " CLIMATE 11 Design Temp Ind Design Temp He Design DeityTemp Design Location TMY Vile 97.5 % 2.5 % Winter Summer Degr�e Days, Moisture Range FL, Fart Pierce FL VERO_BEACH MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blockl 2291 24513.7 2 Blocla 1460 14092 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InN ID Finished Cooled Heated 1 Main 2291 24513.7 Yes 1 1 Yes Yes Yes 2 Bedrooms 1460 14892 No 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area JoistR-Value Tile Wood Carpet _ 1 Slab -On -Grade Edge Insulatio Main 210 tt 0 2291 fN w 0 0 1 2 Slab -On -Grade Edge Insulatio Bedrooms 134 It 0 1460 fl' — I 0 0 1 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Bar Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 4195 fl= 0 V Unfinishe N 0.75 No 0.4 No 20 26.6 ATTIC / V $ Type Ventilation Vent Ratio (I in) Area RBS IRCC 1 Fug attic Unvented 0 3751 ft N 2f42020 7:19 PM EnergyGauge®USA 6.0.02 (Rev.1) - FlaRes2017 FBC 611h Edition (2017) Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Frain ng Frac Truss Type _ 1 Under Attic (Unvented) Main 0 Blown 2291 ft' 0 Wood 2 Under Attic (Urwerded) Bedrooms 0 Blown 1460 ft2 o Wood WALLS Adjacent Cavity Widlh Height Sheat ing Framing Solar Below nmt Space _ 1 N E)dedor Concrete Block - PolyWen Main 0 8 4 12 100.0 ft' 0 0 0.600000 0 -2 N Exterior Concrete Block- Polystyren Main 0 27 8 10 276.71F 0 0 0.600000 0 _ 3 N Garage Frame -Wood Main 13 24 4 10 243.3 ft 0 023 0.600000 0 _4 E Garage Frame -Wood Main 13 34 6 10 345.0112 0 023 0.600000 0 -5 E Exterior Concrete Block- Polystyren Main 0 28 4 10 283.3 ft' 0 0 0,600001 0 -6 S Exterior Concrete Block - Polystyren Main 0 28 8 10 286.7 ft' 0 0 0.600000 0 _7 S Exterior Concrete Block - PotystyrenMain 0 35 10 360.0ft' 0 0 0.600000 0 -8 W Exterior Concrete Block- Potystyren Main 0 15 10 150.0 R' 0 0 0.600000 0 _ 9 E Exterior Concrete Block- Polystyr®edrooms 0 15 10 150.0 ft' 0 0 0.600000 0 _ 10 S Exterior Concrete Block - Potystyrditedrooms 0 27 4 10 273.3 ft' 0 0 0.600000 0 _ 11 W Exterior Concrete Block - Potyslyrd3edrooms 0 62 4 10 623.3 tt' 0 0 0.600000 0 12 N Exterior Concrete Block - PotystynBedrooms 0 31 10 310.0 ft2 0 0 0.600000 0 DOORS # Omt Door Type Space Storms U-Value Width I Height Area Ft In; Ft In 1 N Insulated Main None .21 6 8 48 ft' 2 E Insulated Main None .21 2 8 8 21.3 ft2 WINDOWS Orientation shown is the entered, Proposed orierdagon. Wall Overhang J # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation im Share Screening 1 N 1 Vinyl Low-E Double Yes 0.34 0.23 Y 11.7 112 7 ft 0 in 1 ft 4 in None None 2 N 2 Vinyl Low-E Double Yes 028 021 Y 56.3 ft2 2 it 0 in 1 ft 6 irk None None _ 3 E 5 Vinyl Low-E Double Yes 029 021 Y 31.0 ft2 2 It 0 in t It 6 inl None None _ 4 S 6 Vinyl Low-E Double Yes 029 021 Y 62.0 ft2 2 ft 0 in. 1 ft 6 id None' None 5 S 7 Vinyl Low-E Double Yes 0.33 021 Y 96.0 It" 15 ft 0 in 2 ft 0 ir11 None None 6 S 7 Vinyl Low-E Double Yes 0.28 0.21 Y 64.0 ft2 15 It 0 in 2 ft O irl None None 7 W 8 Vinyl Low-E Double Yes 0.3 0.24 Y 21.3 ft' 35 ft 0 in 2 it 0 iq None None 8 E 9 Vinyl Low-E Double Yes 0.3 0.21 Y 48.0 ft2 35 It 0 in 2 ft 0 in None None 9 S 10 Vinyl Low-E Double Yes 0.3 021 Y 48.01N 2 It 0 in 1 ft 6 itllI None None _ 10 S 10 Vinyl Low-E Double Yes 0,26 0.23 Y 11.7 f12 2 It 0 In. 1 ft 6 b1 None None 11 W 11 Vinyl Low-E Double Yes 0.29 021 Y 22.4 ft' 2 It 0 in 1 ft 6 irj None None 12 W 11 Vinyl Low-E Double Yes 0.29 0.21 Y 43.1 ft2 2 ft 0 in 1 ft 6 i� None None _ 13 N 12 Vinyl Low-E Double Yes 0.28 021 Y 75.0 ft2 2 It 0 in 1 It 6 None None 214R020 7:19 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) i Compliant Software Page 3 of 5 C^MWDenc_on47 INOI IT SI IMMARY rI4FCICI IRT RFPCIRT GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Well Height Exposed Wall Insulation 1 807.5 ft2 807.5 tt' 56 ft loft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH iCH 50 Wholehouse ProposedACH(50) .000334 3283.8 180.28 339.04 .129 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts _ 1 2 Electric Strip Heat/ Electric Strip Heat/ None None COP:1 26 kBailhr COP:1 16 kBlulhr 1 2 sys#1 sys#2 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts _ 1 2 Central Unit/ Central Unit/ None None Single SEER:17 29.6 kBhUhr 888 cfm Single SEER:17 24A kBtuM 732 cfm 0.75 1 0.75 2 sys#1 sys#2 HOT WATER.SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric Tankless Exterior 0.98 1 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft' DUCTS # —Supply— Location R Value Area —Return — Air CFM25 CFM25 Location Area Leakage Type Handler TOT OUP QN RLF HVAC# Heat Cool _ i 2 Attic 6 281 f ' Attic 6 265 ft Attic Attic 93.775 f Default Leakage Garage (Default) (Default) 100 tF Default Leakage Bedrooms (Default) (Def., ult) 1 1 2 2 2/42020 7:19 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 r�r�se'ri�ne 4hA9 rwror IT CI IMRaADV CYCCKI ICT 09:DnDT TEMPERATURES Programable ThermostatCooling Crreiling Fans: Jan X'�Y (FebtX,� Marf W w Jun 47�i Sep Oct Oct at Nov Nov Dec H Dec Venting j ] Jan [ ] Feb Mar Apr [ May Jul A g [ ]Sep X Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 Bo 78 80 78 78 78 78 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Cooling (WEH) AM PM 78 76 78 78 78 78 78 78 78- 78 78 78 78 78 78 78 78 78 78 78 78, 78 78 78 Heating (WD) PM 68 68 66 8 68 68 68 68 68 68 68 66 66 Heating (WEH) AM PM 8 68 66 68 8 68 8 68 66 68 68 68 68 68 68 8 68 68 68 68 68 66 8 66 MASS Mass Type Area Thickness . Furniture Fraction Space Defauft(8lbsfsq.ft. 0 fN 0 ft 0.3 I Main Defa 8lbs/s .ft. 0 fP 0 It 0.3 ,Bedrooms 2f42020 7:19 PM EnergyGauge® USA 6.0.02 (Rev.1) - FlaRes2017 FBC 6th Edition (2017) Compliant Softwala Page 5 of 5 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY ESTIMATED ENERGY PERFORMANCE INDEX* = 95 The lower the Energy Performance Index, the more efficient the 1. New home or, addition I. New (From Plans) 12. Ducts, location & insulation Revel a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-famiy b) Return ducts R I 6.0 c) AHU location varies 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: apacity 54.0 a) Split system SEER 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SE R/COP 6. Conditioned floor area (sq. ft.) 6. 3751 d) Room unit/PTAC EER e) Other 17.0 7. Windows, type and area a) U-factor.(weighted average) 7a. 0.296 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.212 14. Heating system: Capacity 42.0 c) Area 7c. 590.4 a) Split system heat pump I HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor.(weighted average) 8a. NA d) Gas furnace, natural gasl AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE 0 Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) ga. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.98 b) Gas Fred, natural gas EFL_ 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior. d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump w( h tank EF_ 2. Masonry (Insulation R-value) 10A2. 0.0 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 13.0 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Pe onnance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 0.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the Love energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a rew EPL display card will be completedbased dorm installed code compliant features. I Builder Signature: i!'i ` Date: Address of New Home: 18601 Tranquility Base Lane City/FL Zip: 2/42020720:11 PM r EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th EdNon (2017) Complio Software Page 1 of 1 Envelope Leakage Test Report (Blower Door Residential Prescriptive, Performance or ERI Method Comr 2017 Florida Building Code, Energy Conservation, 6th Ec FJurisdiction: 611000 Permit;W. Builder: Mike DiFrancesco Community: Lot: NA Address: 18601 Tranquility Base Lane City: Fort Pierce State: FL Zip: 349 ','Leakage "rrlieteithertoe.Pb,rformance P Alf ,Te-,St'Rdsulli PassingresuNs muss sc;7p,#rrM,* -r%.Me'fhod wQ PRESCRIPTIVE METHOD -The building or dwelling unit shag be tested anciveriffed a having en 4 leakage We a of 6.��in w.sia,pressure ch w.g.'(60 Pascals) In Ornate nes. and Z' - ,,�ch�ngqs.per. A O"i PERFORMANCE or, ERIMETHOD -Tize building of dwpllidl) unit"z'haff be (estecis'nd,verified a " as an air leekaje F rate a t a t itc:H the a&dedAdH(50j yafue� ai'sti&wn �fi l2crin'R405-2017 (Performance) of R466-267:(ERI);-seirllen labeled as infilira 6,6"d1l 590.'-�' 4� 4, H(46dbriForm W405.20Y7-En6W'Caf6(P* x 60 + 39406 Method for calculating building volume: CFM(50) Building Volume ACH(50) I 0 Retrieved from a rchitectural plans OPASS Iculated 0 Code software When ACH(50) is less than 3, Mechanical Ventilation installation 0 Field measured I and calculated must be verified by building department. R402A.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNETnCC 380 and reported at a pressure ol 0.2 Inch w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals fim d as set forth in Section 489.105(3)(f), (g), or Ot or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to thecods official. Testing shall be performed at any time after creation of all penetrations of the building (henna envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other Infiltration control measures. 2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be dosed, but not sealed beyond intended infiltration control measures 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be dosed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. :,,Test* M pan­y� j Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test Printed Name of Tester., License/Certification Issuing Authority: 214=20 720:36 PM EnergyGaugeQ USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (20M Complia nt software Page 1 of 1