Loading...
HomeMy WebLinkAboutCompaction Test 5/28/20Port Sl. Lucie FSPE CA#4939 607 NW Commoddy Cove Pod St. Lucie, FL 34988 Phone: 772-924-35751 Fav: 772-924-3580 Soil Nuclear Gauge Report Date: 5/27/2020 Test Method: ASTM D 6938 Client: Arthur Rutenburg Homes PSL 114 SE Via Lago Garda Port St. Lucie, FL 34952 17-6853.00 Arthur Rutenburg Homes 2017-2018 Master Agreement Various Locations FL No 6321 '• Kent, F:E. '/// /ONAI. Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verged on any electronic copies. Page 1 of 1 Test Results Test # Optimum Maximum In Place In Place Probe Retest Test Soil Moisture Dry Density Moisture Dry Density Depth Of Date Proctor ID Method Classification (%) (pcf) %) (ef) in Min/Max Percent Comp. Compaction (% Remark 97 4/17/20 P-3 N/A 11.8 110.1 11.8 108.3 12 98 951105 Pass 98 4/17/20 P-3 N/A 11.8 110.1 12.4 107.8 12 98 95/105 Pass 99 4/17/20 P-3 N/A 11.8 110.1 12.4 107.4 12 98 95/105 Pass 100 5/8/20 P-3 N/A 11.8 110.1 11.8 108.4 12 98 95/105 101 5/8/20 P-3 N/A 11.8 110.1 12.1 107.5 12 98 95/105 Pass 102 5/8/20 1 P-3 N/A 1 11.8 1 110.1 1 11.8 1 107.9 1 12 1 98 95/105 Pass Test Information Test # Test Location Elevation Reference Gauge Make / Model I SN / Calibrated Field Technician 97 Below Slab Grade: 7683 Pelican Pointe, Port St Lucie, House Pad, Northeast Comer 1-2' of Pad. Troxler / T3430 125092 / Fevrius, Carlo 98 Below Slab Grade: 7683 Pelican Pointe, Port St Lucie, House Pad, Center of Pad. 1-2' Troxler / T3430 125092 / Fevrius, Carlo 99 Below Slab Grade: 7683 Pelican Pointe, Port St Lucie, House Pad, Southwest Corner 1-2' of Pad. Troxler / T3430 / 25092 / Fevrius, Carlo 100 Below Slab Grade: 7683 Pelican Point Drive, Port St Lucie, Northwest Comer of Pad. 0-1' Troxler / T3430 125092 / Fevrius, Carlo 101 Below Slab Grade: 7683 Pelican Point Drive, Port St Lucie, Center of Pad. 0-1' Troxler / T3430 TOM/ Fevrius, Carlo 102 Below Slab Grade: 7683 Pelican Point Drive, Port ST Lucie, Southeast Corner of Pad. 0-1' Troxler / T3430 / 25092 / Fevrius, Carlo Remarks Comments \� 1 t 1 I I I I 1 / �� �0. • • •""• •'VT �i� •' ocEN&' ' Pass: Tests results comply with specifications Tests are"Direct Transmission" (Method A) unless probe depth is noted as "Backscatter'. Gauge calibration data on file with the testing agency. 100, 101, 102: Stem Wall: North, South, East 8 West Foating Center. 0-1, 1-2' HCP=70+, > 95 % Compaction, PASS. HCP tests are iri II Correlated to the relative densityof the oil. No 6321 '• Kent, F:E. '/// /ONAI. Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verged on any electronic copies. Page 1 of 1