Loading...
HomeMy WebLinkAboutConstruction PlansInverter Type: Enphase PVPanel: (37)Axitec315W Racking: Everest Total Wattage: 11,655W Roof Type: Composition Shingles Wind Load: 7 to 27 Deg Fastener Type: Use 5/16" Din 4" Lags S-1 Cover Sheet / Site Plan S-2 Detail E-1 One -Line S-lA Mounting Plan General Notes: -Enphase IQ7 Micro Inverter are located on roof behind each module. -First responder access maintained and from adjacent roof. -Wire run from array to connection is 40 feet. Godwin Engineering and Design, LLC 8378 Foxtail Loop Pensacola, FL 32526 D. Chad Godwin, PE Chad@godwineng.com 1111111 FILE C®Py Utility Meter- -COGEN Disconnect Located adjacent to Utility meter ST.LUCIE COUNTY PLAN REVIEW BLDG: — DATE: ELE . PLUMB: — DATE: — MECR — DATE: Ground Access Point !� C �1 . SETBACKEQ. FRONT SIDES CNR SIDES REAR ZNG. TECH. S 2' Access Pathway n R-1 # Modules (26) Pitch: 20' Azimuth: 181 ° 2' Access Pathway JAN 0 8 "320 Lucie County, Permitting 0 I L1__7_ 3' Access Pathway 0 I 0 R-2 # Modules (11) Pitch: 20' Azimuth: 181' System meets the requirements ofNFPA 1 2015 Edition, Chapter 11.12 FRONT OF HOUSE Meets All Editions of Florida Fire Prevention Code 6th Edition Legend ® Chimney ® First responder access Satellite Utility Meter o Vent Pipe Represents all Fire Clearance Ist Responder Access PV Disconnect including Alternative methods minimum of 36" unobstructed as per Section R324 of the 2015 IRC 2017 FL Residential Code & FBC ,6th Edition (2015 International Residential Code - 2nd Printing modified by the FL Building Standards and Codes 2017 Uniform Code Supplement), 2015 International Energy Conservation Code, County of St. Lucie Code, 2014 National Electric Code. Customer Info: David Ogden 8200 Fort Walton Ave. Fort Pierce, FL 34951 Ground Access Point 3'-3" 5'-5" Layout Subject to Change Based on Site Conditions F�oexioa>? WER x.c 1331 Green Forest Ct, Ste 3 Winter Garden FL, 34787 407-926-0233 Date: 1.2.20 Drawn by: ZW 1 N Checked by: Rev #: 00 • Rev Date: Page: .S'-1 Compass for Aei Everest Rail General Notes: - L Feet are secured to roof rafters. @ 48" O.C. using 5/16" x 4" stainless steel Lag bolts. - Subject roof has One layer. - All penetrations are sealed and flashed. Roof Section I Pitch R1-R2 1 4/12 Roof Rafter and Spacing Overhang Notes: 211x4" @ 24 O.C. Designed as per ASCE7-10 Modules mounted flush to roof no higher than 6" above surface. 201' 1 Truss Inverter Type: Enphase PV Panel: (37) Axitec 315W Racking: Everest Total Wattage: 11,655W Roof Type: Composition Shingles Wind Load: 7 to 27 Deg Fastener Type: Use 5/16" Dia 4" Lags 3/6-16 X 3/4 HEX HEAD BOLT 3/8-16 FLANGE NUT Customer Info: David Ogden 8200 Fort Walton Ave. Fort Pierce, FL 34951 Solar Module Godwin Engineering an Design, LLC 8378 Foxtail Loop Pensacola, FL 32526 D. Chad Godwin, PE Chad@godwineng.com 3-5/8" `�;Nie cll6o /i/. Qom: "VAC EArk F' * 1 N�t� N , FLORI WFAR MAN &GlE- N 1331 Green Forest Ct, Ste 3 Winter Garden FL, 34787 407-926-0233 Date: 1.2.20 Drawn bv: ZW I Rev Date: S-2 W 4lln'Y 11S1O� NrPD�C� �irll WID i1rIr100YY lIpY 4AD9YIOMN smwmTle DUAL POWER SUPPLY vi-Nszlmism 1 SOURCES: UTILITY GRID AND IC SYSTEM �1°01w wsTtnw PV SOLAR ELECTRIC SYSTEM ltrbl®Iln£. S10n(IWAM . nTt�Aw.at. Figure 690.56(C)(1)(a) Label for PV Systems that Shut down the array and the conductors leaving the array #12 AWG THWN for Home runs under 100' 910 AWG THWN for Home runs over 10V (1) Line 1 (1) Line 2 Per Circuit #8 AWG THWN (1) EGC Inside @ least 314" Conduit (tbd on site) I6 MAGOdIMCtkMT A ft7V&099ATJAi ACVMTAGE V meets the requirements ofNFPA 1 2015 In Case of Emergency Call Florida Power Management at 407-926-0233 NEMA3R Junction Box Black - LI Red - L2 Green - Ground S.Wa,k T>V Enphase Combiner Box (1) - 20A Breaker Per Circuit Disconnect 11.12 INVERTER OUTPUT CONNECTION: DO NOT RELOCATE THIS OVERCURRENT DEVICE En a e Cable Photovoltaics: (37) Axitec AC-315M/120S Inverters: (37) Enphase IQ7 Micro Inverters Circuits: (2) circuits of (13) Modules (1) circuit of (11) Modules Roof Maximum Inverters Per 20A Circuit (16) Manual Disconnect 60A Service Rated Fused Disconnect Neutral to Ground Bond AC Disconnect 50A I = Line Side Tap O (1) Line 1 96 AWG THWN (1) Line 2 (1) Line 1 (1) Neutral (1) Line 2 #8 (1) EGC (1) Neutral in @ least 3/4" Conduit Typically in @ least 3/4" Conduit Typically (I)1!8 AWG EGC & GEC Refer to NEC 312a for Conditions on taps in s and over current devices Note: -All wiring to meet the 2014 NEC and Florida electric codes. 60A Disconnect -Type of conduit to be determined on site by contractor. GEC NOTES Provide a grounding electrode system for an ungrounded system per 690.47(C)(3). - GEC must be installed per 250.64 - GEC must be continuous un-spliced or irreversibly spliced from inverter to existing service ground system or continuous from the strays to the existing service ground system. - If GEC is not continuous from the array to the existing service ground an additional ground system must be provided from the ways to a grounding electrode per 690.47(D) - GEC must be min N8 AWG and installed in conduit Enphase Output Ckt Per String To Overcurrent Protection Device AC Max Output Current 13 AC Max Output Current * 1.25% 16.3 Overcurrent Protection A 20 No. of Current Carrying Cond <4 Conductor Gauge AWG 10 Enphase Total Output Ckt AC Max Output Current 37 AC Max Output Current * 1.25% 46.3 Overcurrent Protection (A) 50 No. of Current Carrying Cond <4 Conductor Gauge (AWG) 6 NEC LABEL NOTES: 1. THE WARNING SIGN(S) OR LABEL(S) SHALL COMPLY WITH NEC 110.21(B) 2. LABELS SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE THEY ARE INSTALLED. 3. LABELS TO BE A MIN LETTER HEIGHT OF 3W AND PERMANENTLY AFFIXED. 4. LABELS SHALL ALSO COMPLY WITH THE SPECIFIC REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. Main Distribution Panel 200A Main Godwin Engineering an Design, LLC 8378 Foxtail Loop Pensacola, FL 32526 D. Chad Godwin, PE Chad@godwineng.com \\O��.E CN(1Q%/Z �' —fu FLORIDA` WER MAN a R °,ox „`"°' 1331 Green Forest Ct, Ste 3 Winter Garden FL, 34787 Info: 407-926-0233 Date: David Ogden Drawn by 8200 Fort Walton Ave. Checked 1 Fort Pierce, FL Rev #: 00 Rev Date: 34951 Dn"". 1.2.20 zW E-1 14 16'-0" R-1 # Modules (26) R-2 Pitch: 20' # Modules (11) Azimuth: 181 ° Pitch: 20' 3'-31 Azimuth: 181 ° 5'-5" Godwin Engineering an \����E C �Go Everest Rail Design, LLC 8378 Foxtail Loop * 1160 17' 8 Pensacola, FL 32526 `70 : * r Al D. Chad Godwin, PE ; o r : � ftj� 14' 10 Chad@godwineng.com �8` •:2.2 , •;�@i�� ��is�oNAl ENGj 3J 7' Max cantilever is 16" as per manufacturer Spec. F GI1 A0 F u,ER 4' Max Cantilever = Max Span * (1=48*(1)=16" Splice Bar 12 Customer Info• 1331 Green Forest Ct, Ste 3 Everest Flashings 69 Inverter Type: Enphase Winter Garden FL, 34787 Everest A ids 68 407-926-0233 nd C Everest Ends/End 12 PV Panel: (37) Axitec 315W Snd Caps 2 Racking: Everest David Ogden Date: 1.2.20 Everest Ground Lugs 3 Total Wattage: 11,655W Drawn by: ZW 8200 Fort Walton Ave. Roof Type: Composition Shingles Checked b Axitec A/60S 37 Enphase IQ7 37 Wind Load: 7 to 27 Deg Fort Pierce, FL Rev #• 00 EnphasFastener Type: Use 5/16" Dia 4" Lags yp g 34951 Rev Date: Page: S-lA 310-325Wp AX 1 premium HC 120 halfcell monocrystalline High performance solar module The advantages: I1 15 years manufacturer's warranty ®_ © Highest module performance through ® Half -Cut -technology and tested materials Guaranteed positive power tolerance from 0-5 Wp by individual measurement © Maximum 5400 Pa snow load IMIMM F100% electroluminescence inspection High stability due to AXITEC-Soft-Grip-Seam aluminium frame construction Lot High quality junction box M and connector systems Exclusive linear AXITEC high performance guarantee! • 15 years manufacturer's guarantee on 90%of the nominal pert e 25 years manufacturer's guarantee on 85%of the nominal pert m e m E tools 97% AXITECW1 rranty ra. Added Val www.axiteasolar.com -A-XI-TCC high quality german solar brand eo% uef m — � v' 85% ss^/° 1-8%more power E eon eo% after 25 years $ commercial m leveludarranly o% 3 1 5 10 is 20 25 Years N E a www.axitecsolar.com AAXI-TCC high quality german solar brand AXI r mi m p e u HC 310 - 325 Wp Ete i141'data (atstanCard conditidns.(STC) frradlance 10!IQ waiftl spedruin AM 1�5 at agelf fernperature of 25W- .I 'Type, drpivaloulput .Norninhivoltaii Nominal`rvrrent< :8hdd`cfmuit current: Open clreuit yolWge 'Moduleconversien. Prnpp . - JIM' .. }SC'' Udb efll4le9Ey- AC 310MNl1208r 31o�Wp. .3271V 847A. SLAW- 400t:V. 1868,Ye'. :rAC315Mtf/1205 3i$.Wp, ,3297 V,,' 19;56A V. ,18,96,%j �AG320MFI%)2dS 320 Wp ;332t'V,• 9'"k �gii.•A' •40.25 V; PAG325MH)�203 326Wp1 r.33;4s V. 973A 4 18At r9dISZ V: 118,55% Design' . - .. ' iLImEtValuas, i �I �Fronr.lde._ _32mmhardened loxt-[elrecuodwhlle gress:� 1 r4, System voltager 1(pO �DGt :Cells; -i2dmanocrystelline hlgft oHiaen�Ce�s K x NOCT (nom(ealbp�rafing aeu Wmpefaie) 45 c+7-7JG '458.X5mrii i f 3Q mfIG• .... I MaK fgadrarry4g capaply; 16400 y1W r B-aek;ket •.Compoeila. f!m•, INevef3g cur{em reed;fR' 'Nf'UA. 'Franz '-�35'_mmsrWe_r eiumipi5m liame�. Permissi6la o�eMung' ` ' lempetalur� �40 CWa5°GjE•40F Io11B5F } Me°hanleal oars; f1 '`"'" �. 9 g!eaWrthari floc. �Noeule.r el voila es f C3 W,51}-,-{675s1;9925{S .?u11' p iWelghl.'. • ' •> -.18f5'�g@ioZl - f1n1%.G9apPried,tb'lhe'jil"oQu!8� O _ � Noce tri�rea� eaa w>mz[;tt;{;sr i .lkeomiec!10n - 1 ' bvrinA spuCE,.t,iiUs;Ye'mpereW7e 2o'c - 'f 1 PrptectlonCfass IP88; • ,appruj� i;i mi 4: MW't ' i sy61p[(1: • � 1ry�9%edkkel.11?63': Pmpp� Paefc5ging.r Module pieces perpaller 3d Muddle pieces per HC-Container - 780 Te°mkW data ere &object W d"e without prior mica, errors excepted. The rrnoo;uMMoM tolerances ere 4h % Data Sheet Enphase Microinverters Region: AMERICAS Enphase IQ 7 and IQ 7+ Microinverters The high-powered smart grid -ready Enphase IQ 7 Micro'" and Enphase IQ 7+ Micro'" dramatically simplify the installation process while achieving the highest system efficiency. Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoym, Enphase IQ Batteryn`, and the Enphase Enlighten' monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power -on testing, enabling Enphase to provide an industry -leading warranty of up to 25 years. Easy to Install • Lightweight and simple • Faster installation with Improved, lighter two -wire cabling • Built-in rapid shutdown compliant (NEC 2014 & 2017) Productive and Reliable • Optimized for high powered 60-cell and 72-cell* modules • More than a million hours of testing • Class II double -Insulated enclosure • UL listed Smart Grid Ready Complies with advanced grid support, voltage and frequency ride -through requirements Remotely updates to respond to changing grid requirements Configurable for varying grid profiles Meets CA Rule 21 (UL 1741-SA) * The IQ 7+ Micro Is required to support 72-cell modules. Enphase IQ 7 and IQ 7+ Microinverters ,INPUT DATA (DC) IQ7-60-2-US/IQ7-60-B-US I07PLUS-72-2-US/IQ7PLUS-72-8-.US °Commonly;usedmodule 236W�440WW+. Module compatibility 60 cell PV modules only 60 cell and 72-cell PV modules i via m input ID Alta e- _21 Peakpower.trackmgvoltage 27V 37V 27V 45V SOpYerahn'9_�.ange.. _ _.._ -_ _ '"-'16V 48V�---�--______-... •16`V''60:V;----'- -- --_ -_�_ ___� -.= 1 Min/Max start voltage. 22 V / 48 V _.- -- �- 22 V / 60 V I ^_�_ Matt DC s' rort cucuiycuimid,�module'Is,i�e15Ar 5A Overvoltage class DC port __ _ _ _' II II 1DG;pon•back(eed'curfeni _ _ _ D'A'' _ _� _-1'xlungroupdedarray;Noaddit(onarDC-sideorotedtipnrOgUired; _ ipVarrayconfigOration • AC side protection regdires max 20A.per branch circuit OUTPUT DATX(AC). 907•Microlnyerter• 1Q 7r Micr_oinverter. ';Peakcuiputpower__--�----,._ __ ---- - -.:250Ve_ ..._- ---.. ._. _ _ 299VA i Maximum continuous output power 240 VA 290 VA �Nolninaf`(LLI.�Voitage7range'� "--- �7AOVI -� 208V"%I 2'40,y-/-�'r208Vf ?211 26y4 Vi_Y 1832.291(„ 103.224V Maximunicontinuousoutput current _ _211r2G40i _ -� 1.0 AA�240. V) 1.15A(206 V) i.21A(240 V) 1.39A(208V) Extended.frequendyfange 47 68 Hz 47 68 Hz rAC shoit"clicultfault current over3cycles—�5 Maximum units per 20 A (L-L) branch circuity' 16 (240 VAC) 13 (208 VAC) 13 (240 VAC) 11 (208:VAC) fillOv, emoltage class AC pod.. AC port backfeed current OA 0 A v - 11b `16 Powerfaator.(a_justable) _ -- -� _ 0.7teadhig.•-b.7laggin9 _ •VIeading,,.0.7tagging EFFICIENCY - @240 V @208:V •@Z40;V @298V rFeeaI�OEGeffci52;X .47fi; '_ _ 975°y,'.^-- -. :97.rid"°.-'--„_9. U%,a-_.-._._--..--___� � �97.0 • CEC weighted efficiency 9TO %. 1° '970% 97,0.% - MECHANICAL DATA Ambrent.ternperaturefage-.`-,_-z Q65°G Relativehumidityrange• 4%to100(condensing) Conrectartype'(IQ7.6U;2(lS&IQ7PLUS+j22tlSjip�C4�(A�rip�i2(lo(F¢,:�W(t,�dd�t1of(atQ'DGG-adapief}-,.-.,;_.-..__._.._..,.n._ __-...��.. Connector-type(iQ7760-B-US&IQ7PWS72-8-US) .Friends PV2 (MC4 jrjtermateable).. r PV2 to MC4: order ECA-S20-S22 - PV2 to UU: order ECAS20-S25 --- —r'T �' 212mmyx�175 mm�x3,o.2mm�"withquflirae(tet 1.68 kg.(2 38lbs) T" _Netufafconvection Nofans; -..—..9...—.._ _.... .::Yf_,J✓ a --_. :. X_ _ _� .._-.�� i..- _- s — �_ �-_._ _..- — Yes .,....._.-_.-_`._..._'-_-�:>•'---'.-�-: _-.=.�-_,._.-•_-.--__...�-.�____._..wA:._ .__.mot---- -"-..---'',-_ -- Class Itdouble-insulated, corrosion resistant polymeric enclosure io'tvltlVexodsureratinor. sNEMt Wine vnowe�rwn�ewmmumcauetrtrctil: - • I Monitoring Enlighten Manage( and MyEnlighten monitoring options. Both options require Installation of an Enphase IQ Envoy. ,Disconnecting means( �� `; The AC and'DC connec i4have been'.eVailiated•an'd apPrgyp ilitiY -- L0ruse;as the Ii agvri a5_ _ _ •,dlsconner:f re-qulred byitfEG_ _ I Compliance CARule21 (un74t-SA) UL 621094, OL1741)IEEE1547, FCC Part 15 Class B, ICES-0003 Ctdss B, CAN/CSA-C22.2 NO.107.1.07 ' This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer's instructions. 1. No enforced DC/AC ratio. See the compatibility calculator at httos•//enphase cam/en-us/slgrport/module.comnatib'I'ty. 2. Nominal voltage range can be extended beyond nominal if required by the utility. 3. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. r..r� 0a EN PHASE. To team more about Enphase offerings, visit enphase.com 'Z EN PH AS E. To learn more about Enphase offerings, visit enphase.com i.� © 2018 Enphase Energy. All rights reserved. All trademarks or brands used are the property of Enphase Energy, Inc. 2018-0-24 CrossRail System to(arsystem 10 7 U Item No. Description Product 1 EverFlash eComp Kit, Silver or Black 4000367, 4000366 Lag. 9rj-PV 4511,6x4;5S_ 4000359____ 3 L-Foot Slotted Set, Mill or Dark 4000630, 4000631 44" CfpsOail 80;16V Rail; Mill 4000508 5 CrossRail 80 End Cap, Black 4001221 6. _ -CrossRail 48-XL_i66"., Nl(II,o� Dark_ 4060695, A0o070S, , 7 CrossRail 48-X/48-XL End Cap 4000433 I- _ i8 Cfo`ssRail 48-X.166 :or 1:75%.Will cir Dark. 4000662j;4000675,'4000663. 9 CrossRail 48-X/48-XL 3" Sleeve 4000583 y]0_ _, GR.MidClamp;Silver or Dark_ ,_ _ _ _ j 4000601, 4000602_ CrossRail 48-X Mechanical Properties Material 6000 Series Aluminum Yield Strength 134.8 ksi (240 MPa) Finish Section Properties Sx A (X-Section) [41 1,89 Notes: [39] ➢..54 Mill or Dark Anodized 0.199 in3 (3.261 cm3) 0.467 in2 (3.013 cm2) [42 16 "40] 1 6b �� r Dimensions in (mm] Inches 0 Structural values and span charts determined in accordance with Aluminum Design Manual and ASCE 7-10 0 UL2703 Listed System for Fire and Bonding www.everest-solarsystems.com www.everest-solarsystems.com