Loading...
HomeMy WebLinkAboutSoil Nuclear Gauge_Test-0289-0296_6283258Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 289 Building Pad Fill: House Pad at 9512 Silver Sands Lane, Lot 4. Footing E Side -2.0 Top of Pad Troxler / T-3430 / 21330 / Tech, Port St. Lucie 290 Building Pad Fill: House Pad at 9512 Silver Sands Lane, Lot 4. Footing N Side -2.0 Top of Pad Troxler / T-3430 / 21330 / Tech, Port St. Lucie 291 Building Pad Fill: House Pad at 9512 Silver Sands Lane, Lot 4. Footing W Side -2.0 Top of Pad Troxler / T-3430 / 21330 / Tech, Port St. Lucie 292 Building Pad Fill: House Pad at 9512 Silver Sands Lane, Lot 4. Footing S Side -2.0 Top of Pad Troxler / T-3430 / 21330 / Tech, Port St. Lucie 293 Building Pad Fill: House Pad at 9512 Silver Sands Lane, Lot 4. Foundation SE Corner -1.0 Top of Pad Troxler / T-3430 / 21330 / Tech, Port St. Lucie 294 Building Pad Fill: House Pad at 9512 Silver Sands Lane, Lot 4. Foundation NE Corner -1.0 Top of Pad Troxler / T-3430 / 21330 / Tech, Port St. Lucie 295 Building Pad Fill: House Pad at 9512 Silver Sands Lane. Lot 4. Foundation NW Corner -1.0 Top of Pad Troxler / T-3430 / 21330 / Tech, Port St. Lucie 296 Building Pad Fill: House Pad at 9512 Silver Sands Lane, Lot 4. Foundation SW Corner -1.0 Top of Pad Troxler / T-3430 / 21330 / Tech, Port St. Lucie Remarks Pass: Density Pass Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 289 5/18/20 20-153 (Modified) A --9.5 116.0 14.2 110.7 12 95 95 Pass 290 5/18/20 20-153 (Modified) A --9.5 116.0 12.8 111.2 12 96 95 Pass 291 5/18/20 20-153 (Modified) A --9.5 116.0 13.6 110.3 12 95 95 Pass 292 5/18/20 20-153 (Modified) A --9.5 116.0 13.0 112.0 12 97 95 Pass 293 5/18/20 20-153 (Modified) A --9.5 116.0 12.9 111.4 12 96 95 Pass 294 5/18/20 20-153 (Modified) A --9.5 116.0 12.8 109.7 12 95 95 Pass 295 5/18/20 20-153 (Modified) A --9.5 116.0 12.6 111.7 12 96 95 Pass 296 5/18/20 20-153 (Modified) A --9.5 116.0 9.9 112.5 12 97 95 Pass AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL. Page 1 of 1 Soil Nuclear Gauge Test Method: ASTM D 6938 Permit # 2003-0421 Report Date: 5/28/2020 Client: Renar Development Corp. Stuart, FL 34996 3725 S. East Ocean Boulevard, Suite 101 Project: Morningside Residential Lots 113-15-66-5434B Fort Pierce, FL Fort Pierce Florida CA No. 5950 460 NW Concourse Place, Unit 1 Port St. Lucie, FL 34986 Phone: 772-878-0072 Port St. Lucie Branch Page 1 of 2 AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL. Page 2 of 1 Soil Nuclear Gauge Test Method: ASTM D 6938 Permit # 2003-0421 Report Date: 5/28/2020 Client: Renar Development Corp. Stuart, FL 34996 3725 S. East Ocean Boulevard, Suite 101 Project: Morningside Residential Lots 113-15-66-5434B Fort Pierce, FL Fort Pierce Florida CA No. 5950 460 NW Concourse Place, Unit 1 Port St. Lucie, FL 34986 Phone: 772-878-0072 Port St. Lucie Branch Page 2 of 2 This item has been digitally signed and sealed by Branch Manager Dan J. Zrallack, P.E. on May 28, 2020 using a Digital Signature. Printed copies of this document are not considered signed and sealed and the SHA authentication code must be verified on any electronic copies.