Loading...
HomeMy WebLinkAboutConstruction PlansInverter Type: Enphase PV Panel: (27) Q-Cells 335W Racking: Iron Ridge Total Wattage: 9,045W Roof Type: Comp Shingles & EPDM Wind Load: 7 to 27 Deg Fastener Type: Use 5116" Dia 4" Lags & Roof Tech Mini's Sheet Index S-1 Cover Sheet / Site Plan S-2 Detail E-1 One - Line S-lA Mounting Plan General Notes: -Enphase IQ7PLUS Micro Inverter are located on roof behind each module. -First responder access maintained and from adjacent roof. -Wire run from array to connection is 40 feet. N\\4�"AGo Vtcl E , ;0 X, F 1360 : Z O• %., c r of �ORIDP. L ENG� �i�3IJ� Godwin Engineering and Design, LLC 8378 Foxtail Loop Pensacola, FL 32526 D. Chad Godwin, PE Chad@godwineng.com R-3 # Modules (6) FILE C®PY Pitch: 11' Azimuth: 58' 3' Access Pathway 2' Fire Clearance @ Gutter R-2 # Modules (6) Pitch: 11° Azimuth: 238' o \X\K V V/// {tssst•/s rf{trrif73rrr/err $G� •{t 0 rxrvGirrrrlffrrslrrrrrl ---- frfirro Located aTja-centto Utility rucw: DATE ELS 0 DATE '�� �` DAM R-1 PLUM # Modules (6) DATE, DATE MECH: Pitch: 11 ° DATE: Azimuth: 148' FRONT OF HOUSE System meets the requirements ofNFPA 1 2015 Edition, Chapter 11.12 Meets All Editions of Florida Fire Prevention Code 6th Edition Legend ® Chimney ® First responder access Q, Satellite 0 Utility Meter o Vent Pipe Represents all Fire Clearance I st Responder Access including Alternative methods minimum of 36" unobstructed as per PV Disconnect g Section R324 of the 2015 IRC 2017 FL Residential Code & FBC ,6th Edition (2015 International Residential Code - 2nd Printing modified by the FL Building Standards and Codes 2017 Uniform Code Supplement), 2015 International Energy Conservation Code, County of St. Lucie Code, 2014 National Electric Code. Customer Info: Ground Access Point R-4 # Modules (9) Pitch: 0° Azimuth: 148' MIN. SEiBACi( ncl7. FROWT SIDES_ CYR Sit REAR Dave Indarjit 613 Beach Ave. Port St Lucie, FL 34952 754-246-1540 ' o AP�i Y 8 F� CGC0 C"D O c 0 2' Fire Clearance @ Gutter Ground Access Point 3' Access Pathway 2' Fire Clearance @ Gutter Layout Subject to Change Based on Site Conditions EH S Efficient Home Services 9416 International Ct, St. Petersburg, FL 33716 844-778-8810 Date: 1.3.20 Drawn by: SP Checked by: Rev #: 00 Rev Date: Page: S-1 General Notes: Rl-R3 - L Feet are secured to roof rafters. @ 48" O.C. using 5/16" x 4" stainless steel Lag bolts. - Subject roof has One layer. - All penetrations are sealed and flashed. Roof Section I Pitch R1-R3 1 2/12 R4 1 0/12 General Notes: R4 - Roof Tech Mini's are secured to rafters @ 48" O.C. using (2) M5 x 60mm stainless steel Lag bolts. - Subject roof has One layer. - All penetrations are sealed. Roof Rafter and Spacing Overhang Notes: 211x4" @ 24 O.C. 211x6" @ 12 O.C. 20" 1 Truss 2011 Designed as per ASCE7-10 Inverter Type: Enphase PV Panel: (27) Q-Cells 335W Racking: Iron Ridge Total Wattage: 9,045W Modules mounted flush to roof Roof Type: Comp Shingles & EPDM Wind Load: 7 to 27 Deg no higher than 6" above surface. Fastener Type: Use 5/16" Dia 4" Lags & Roof Tech Mini's Customer Info: Dave Indarjit 613 Beach Ave. Port St Lucie, FL 34952 754-246-1540 solar Module 3/8-16 X 3/4 HEX HEAD BOLT 3/8-16 FLANGE NUT Godwin Engineering an Design, LLC 8378 Foxtail Loop Pensacola, FL 32526 D. Chad Godwin, PE Chad@godwineng.com Date: Rev Date: 3-5/8" I EH S Efficient Home Services 9416 International Ct, St. Petersburg, FL 33716 844-778-8810 1.3.20 SP S-2 RAPM 14e [arD�O AIM W211 @� smoerop DUAL POWER SUPPLY •'��ro SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM it 9OR aAr iD . nTr�Aa� Figure 690.56(C)(1)(a) Label for PV Systems that Shut down the array and the conductors leaving the array # 12 AWG THWN for Home runs under 100, # 10 AWG THWN for Home runs over 100' (1) Line 1 (1) Line Per Circuit 08 AWG THWN (1) EGC Inside @ least 3/4" Conduit (tbd on site) meets the requirements ofNFPA 12015 In Case of Emergency Call Efficient Home Services at 844-778-8810 NEMA3R Junction Box Black - LI Red - L2 Green - Ground solace[, Typ Enphase Combiner Box (1) - 20A Breaker Per Circuit Disconnect 11.12 INVERTER OUTPUT CONNECTION: DO NOT RELOCATE THIS OVERCURRENT DEVICE En a e Cable (1) Line I (1) Line 2 (1) Neutral #8 (I) EGC in (a) least 3/4" Conduit Note: -All wiring to meet the 2014 NEC and Florida electric codes. 60A Disconnect -Type of conduit to be determined on site by contractor. Roof (27) Hanwha Q.Peak Duo BLK 335W Inverters: (27) Enphase IQ7PLUS Micro Inverters Circuits: (1) circuit of (6) Modules (1) circuit of (9) Modules (I) circuit of (12) Modules Maximum Inverters Per 20A Circuit Line Side Tap Manual Disconnect 60A Service Rated Fused Disconnect Neutral to Ground Bond AC Disconnect 50A Fuse O #6 AWG THWN (1) Line 1 (1) Line 2 (1)Neutral in Q least 3/4" Conduit Typically EC 312.a fors (q#8 AWG EGC &GEC on IaP in aw—I devicessditions FE are notbox wille installed. GEC NOTES Provide a grounding electrode system for an ungrounded system per 690.47(C)(3). - GEC must be installed per 250.64 - GEC must be continuous un-spliced or irreversibly spliced from inverter to existing service ground system or continuous from the arrays to the existing service ground system. - If GEC is not continuous from the army to the existing service ground an additional ground system most be provided from the arrays to a grounding electrode per 690.47(D) - GEC must be min 48 AWG and installed in Conduit Customer Info: Dave Indarjit 613 Beach Ave. Port St Lucie, FL 34952 754-246-1540 Enphase Output Ckt Per String To Overcurrent Protection Device AC Max Output Current 14.52 AC Max Output Current * 1.256% 18.15 Overcurrent Protection A 20 No. of Current Carrying Cond <4 Conductor Gauge AWG 10 Enphase Total Output Ckt AC Max Output Current 32.67 AC Max Output Current * 1.25% 40.84 Overcurrent Protection A) 50 No. of Current Carrying Cond <4 Conductor Gauge (AWG) 6 NEC LABEL NOTES: 1. THE WARNING SIGN(S) OR LABEL(S) SHALL COMPLY WITH NEC 11a2l(B) 2. LABELS SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE THEY ARE INSTALLED. 3. LABELS TO BE A MIN LETTER HEIGHT OF 3/8" AND PERMANENTLY AFFIXED. 4. LABELS SHALL ALSO COMPLY WITH THE SPECIFIC REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. Main Distribution Panel 150A Main Godwin Engineering and�N�O C. N� c E iilS O�Y., Design, LLC 8378 Foxtail Loop * ;0 Pensacola, FL 32526 ZZ o a of %4f4- D. Chad Godwin, PE �Z//��SS�oALG`2\`` Chad@godwineng.com ''�n►u I I►����Z'`73r�b EH S IM Efficient Home Services 9416 International Ct, St. Petersburg, FL 33716 844-778-8810 Date: 1.3.20 Drawn bv: SP I Rev Date: I E-1 13'=9" 111 21 ■w�wwri - Splice Bar 12 Flashings 37 Mounts 33 UFO's 66 Sleeves/End Caps 24 Solardecks 3 Ground Lugs 6 n -11 R-1 # Modules (6) Pitch: 11' Azimuth: 148' R-3 # Modules (6) Pitch: 11 ° Azimuth: 58' Inverter Type: PV Panel: Racking: Total Wattage: Roof Type: Wind Load: Fastener Type: 1 11 R-4 # Modules (9) Pitch: 0° Azimuth: 148' R-2 # Modules (6) Pitch: 11' Azimuth: 238' Max cantilever is 16" as per manufacturer Spec. Max Cantilever = Max Span * (1)=48*(1)=16" Enphase (27) Q-Cells 335W Iron Ridge 9,045W Comp Shingles & EPDM 7 to 27 Deg Use 5116" Dia 4" Lags & Roof Tech Mini's Customer Info: Dave Indarjit 613 Beach Ave. Port St Lucie, FL 34952 754-246-1540 Godwin Engineering an Design, LLC 8378 Foxtail Loop Pensacola, FL 32526 D. Chad Godwin, PE Chad@godwineng.com C. IM f/fffr �'/�� EH S .. Efficient Home Services 9416 International Ct, St. Petersburg, FL 33716 844-778-8810 Rev #: 00 Rev Date: 1.3.20 SP S-IA I' r I W-MykFM1p sn-sllaa-b'mxm Mee I woo-seso-b-sn®AJ!nbul IWM 196 69 9VL 6V6 T+131I Vsn'8I966 V0'OUINI'OSZT ellnS'aWa Jawao wngaads 008 'Oul eoPOwIf ST133 V "IMEH 'lonpwd slgl jo wn pue uopellejsu! paemdde uo uolleuuo;u! Jagp%Jol wawpedap aolmas I¢J!ugo Jnu laeleDQ M lenuew 8unelado pue uolwlleJsul ael a S'pamollol o ;SOW SUMP lgsul u09ellejsul =N VNE89) N19091 MOM Ielled (ww00Zi x W W O91T x ww ST8T) ul Z'L4 x ul E'9V x u15IL (H x M x 1) Sualsuew!01911ed 93 Joulewoo egn9 W!H Ab led slalled ju jagwnN 67 ioneJ1 R9 Jed awiled /a JogwnN ZE jelled Jed salapoW in jogmnN V ssela uollea!IVde'9IOZ:OELI9 O31 !910Z'SIZI9 031 !juelldWoo'33!P93sal AJ!len03OA!COLS In lenuew uoNellelsu!aasa (ed OOOV)V8/(ed OOVS)£TT LMMIl Bind/4snd'peo17sa1'seW (0, Sg+ of do 0.04-) 4.991+ol do 3.Oa- 11nP snonuquoP We eJlgeiedwei elnpow Peplwed (ed L99Z) 991(ed009E) 9L IMS91I ,gsnd'peal uIllwa xeW (In) T 3du / (031) O SUIMH wig OZ IOtl VI HupeH Ong wiles wnwpwW D mew Ames (1N 0o0T/(33D 000l EAI 1 '{{A llftloA maWlS mnwPMW MISAS 110:11. (0.£z EV) 4'9$ 60I Ed.) TOWN elnWedwel Helluedo a(npah MILLION LE-0- IN/%] A 'ad W julaWsoa eJdgwadwal 8Z'O- 01/%] 8 '°A to luslo81eo0 wlgeledwel b0'0+ IN/%] a a'I jo lue!agleoo ainimadleaL -).--s1N31OU33W 3Hn1tlV3dW31'. ( w/M0001 3.SZ) SUORIPuoo 01S W uosuedwoa ul suc%puoo eouelpeu! "I apun ww wJapad elnpow Ieold61 u"' 9 I - e '� _ taJm nxriousw a I ® m ® m u i I ! _____I �_____,.____�_____�__ esaweJaa •Aqunoa m!}vadmj JnoA to uDNe=!uesJD sales S1133 D agi 10 suual Alueuem a ii gj!m;xwepj=v w sa0ueliem IIn3 uawwnseaww m slap _ - r ..-=- i m I A 17] .gp lltl ' 3 -sJea6 9Z of do JaMod leulwou jo %9B jsral ZV i '- ' -- ml m 've-j OI of do J.mod le.% to %I'£61sea1 jV ------ 9 - -- � 9 I I Jea3 Jatl uole wPa I P P%bS'0'lew Jaaewayl d D _ L __J_ mlM xg jLNHYIJn JaN IOUIMU %Bb LsltlL_ — e3— NVWa03g3d1Ir7_ - u3 ._ 37xalOtla37xWaa3e,, 99'I WV wlwo 'JDWN',-/M 009,'£-a0609331 W eulP 99'1 WV0.Z-9Z',w/Moa01'01Sw%9i-A°J!%Cs ad seoUMA luaw—W, I6'I£ 09,1E 6Z'IE 86'0E W "'A ddW lea BiloA b8'L 08'L 9L'L ZL'L IV] tle11 ddW W IuaN[1O £0'8E 6L'L£ bS'L£ OE'L£ W DOA aBgloA gnwla uado a Ep'8 6E'8 SE-8 OCT IV] .1 jualmolinal!O poyS 9 £'OSZ 9'91pZ 8'Z4Z I'6£Z EMI —d ddW le JPMod dOWN'SNOIl10NO3 ONU MMO WWaON IV iONVININ83d WflWINIW L'9Tz V'8Iz I'8Iz 6'LIZ I%] 0 ,Aoue!oW3 MEE 6Z'EE L6'ZE V97E IM "IA ddW W MUM L6'6 I6'6 98'6 08'6 IV] "!I ,ddW to lueunO 3 Ib'Op 91'OV 06'6£ 99'6£ W MA ,93elloA gnoJlo undo a Lvol IV'0I 9E'OI 0£'0I IV] "1 PalmO 11110113 Polls 913E 013E SZE OZE IMI "!d ,ddW 1e JaMod (MO-/ M9m 33NVH3101 H3MOd) ,31S'SNOWONOO 1S310HVONVIS IV 3ONVWVO3a3d WnwiNIW m.aoo<m m.®ml 0-,a..�IpIw•wuv °°"° ""I�.. 89dl'bOW jaejuo0-nlnW 2012auuo0 (ww OSTD u!£'S4z(-)'1ww05IU n!E'Sgz (+):algeo JelDS awwb 6I9e3 - o-""' ® L9dl'Paz!lellusm!)'(ww TZ-ET x wwOS-It, x will TL-T9) ul E8'0-150 x u! I07-I91 x u1097-ClyZ xaq uogounl sllau-jleg mos Wn1NV'0 eull!elskoouow OZ x 9 1183 w wwnle paz!poue Xoele eww3 wl9 ellsodwoo JeAao MODE ABolougaal uogoallal-gue gllM mIS pavmM-aid ABeuuagj (wwZ'E) u!£I'0 Janao je013 (SX6'6T)Sg16Tl7 Am wnJos® (ww ZEx WWOEOT x ww OYLT) (aweli Hu!pnlau!) u!gZ,ixu!g,0yx u!g,89 Jewo3 1 I��a�aAIIi,d+l _ ii77 'Poise, AIIRnb I__ ,a,,_; �I H�evJ{ �fn -- - udsswwvORMig F-Awl -f(o)inlo_t. `Ib3a13fi a aio`�iibbbwav'�-u3or-aiv_is 0.'t�311�f��fSl �]jl8it113�i`_ e J : 'II { ech�r { :,ju7 • ...� { � d i • 'x a ijd *Li i' "• FRO MH Niff(3ota3 Lit6�bfiH5f 931i�MLI3ISfTi�bltafif N�}0+�-v'Se�l.'.0 �,•9L+4!e�L �'�Ti��B C� (��9j�2��$}�$�;JjjQ3Z173�1��Ti��'h�J�6�IHJ �Ai�lfdt?-'pl ��C���iat�Uns,geal� �;.mJl [iih �ii113u1'i�n�'lrUl MfiQ1 R KIM Bra un a3ueuKtr n it �+ j -1 PUMA 1931M M M M a," A10-MOM) �P"'FAAMI!Cod Data Sheet Enphase Microinverters Region: AMERICAS Enphase IQ 7 and IQ 7+ Microinverters U�' EMEWAM To learn more about Enphase offerings, visit enphase.com The high-powered smart grid -ready Enphase IQ 7 Micro'" and Enphase IQ 7+ M)cro� dramatically simplify the installation process while achieving the highest system efficiency. Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy'", Enphase IQ Battery'", and the Enphase Enlighten'" monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power -on testing, enabling Enphase to provide an industry -leading warranty of up to 25 years. Easy to Install • Lightweight and simple • Faster installation with improved, lighter two -wire cabling • Built -In rapid shutdown compliant (NEC 2014 & 2017) Productive and Reliable • Optimized for high powered 60-cell and 72-cell* modules • More than a million hours of testing • Class II double -insulated enclosure • UL listed Smart Grid Ready • Complies with advanced grid support, voltage and frequency ride -through requirements • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) • The IQ 7+ Micro is required to support 72-cell modules. ENPHASE. Enphase IQ 7 and IQ 7+ Microinverters RIVra%IMO,mum�mput dt :vollage - Peak powertracktng voltage 27 V 37 V 27 V 45 V ��� • �- Y4 — �� t%''60V`_—�' Min/Max start voltage. _ 22 V 48 V 22 V 160 V yiu c'short caeuif-bbitenC,(modJle lsi:)+ +15'A, 15 Overvoltage class DC port 11 II ;OYA PU array;configuraltop 1 91 ungmupdeAarray; Noat(dtt(onaJ pGSjde protection r2qulred,' +AGelde protection requiretmax 20A,perbranch chauii OUTPUT DATA'.(AC). -- - _'IELTMtcrolnVerter - _ '107+MicroinVerter 'Peakzomputpower" _- :295VA N Maximum continuous output powers 240 VA 290 VA aNamjpal`(CLjvolta`ye/ienge "-`•-`---"1240,V! 208Vh ;240,y/ • ` 208VJ'- ""` _. _r,� _ - _ �11� 264Yi 183229v _ Maxir umcontiniousobt 6t'cureen- - '1.OA.(240V) 1.15A(208V) 1.2VA,(2401V) 1.39R,(208V) Nnalfrequenc"_ Extended frequency range 47 - 68 Hz- 47=08 Hz V6sfiort circurt+faillt current o ere ,4y—gles-",5 8 Arrtrs,"`"'+"� 5 Maximum units per20,A (U) branch circuit°_ 16 (246 VAC) 13 (208 VAC)__T 19 ( AC) 1:1 (208�VACJ rt ;Overv`olJag�eslassAO po- _ A Al) pert backfeed current O A 0 A _ _ PoVteti ctorse�ttin9 �DI - --` — -. __.. PoWarfactor(ad)Ustable)_ 07 0.7leadilig... _07{aggjrtg .(esding.,.D?wagging.~ I EFFICR?NCY - -- _@240-V ;@N&V _ �@240 V @208,V - P•eak;CEG,effi_ctdQg �.� 976'>o' _.- _.,__i 6'°z,.'°,____... _ '97;Sym., ..97:3iY,•. .._.P-_�..,..._..`w ,_�_ �97W. < CEC'welghtedefficienDy ~97:016µ 97.,0?I 97A' a ._ MECHANICAL DATA i rArrjbienttemperatute`rarige '- - "�4g°L`to+65°C. - -- '` - --- -_ .. Relative humidity range) 4 , to ibo%(condensing) _ aConllecjiiptype(T07-'64f2w MCO7Pi�1S722US).t?ryt�a(oi'. mPherlo,4, 47 Connedtortype(i97-60-B-US&IQ7PLUS72-B-US) :Friends FV2C&fc4 iq�e{mateable)_ - Adaptors far modules with MC4 or UTX connectors: -PV2 to MC4:order ECA-S20-S2Z: - PV2 to UTX: order ECAS20-S25 _ :x, 75'mm-x1 2 mm _1 fiou`t7irack,t Weight 1.08 kg (2.38 lbs) CoolingT Naturai`convecuon Ra Approved 'forvtetloca[ions -•Yes Pol(uuonPDo Enclosure Clan itdou le ihwlated corrosion resistant polymericenc)osure -- E�Ylron'rtlenta).�ategiTry'1'J.V,eXJl6sdreratitlg�;"rNEMA:rype$+jeoUtd0or�" FEATURES Communidatlon= - - IRower L+IneCotnniunlc'aticn(PEC)i + Monitoring .Enlighten Manager and MyEnlighten monitoring options: Both options require installation of an Enphase IQ Envoy. DJsconriecffngmeags=�_� �_. 'Y' TbeACanil!DCca^necforshavebeeneya(uateda�r-•dapprovec)hyULto: rtiseastbe)o5d;6rea1t7_ ' discoOpect regdred bV NE969L Cdnmljance CARule 21UX1741-SA1 __._ _ _ _- -.. •.._ .. lj UL 62109 1,UL1741/IEEE1541 FCC Part15 Class B, ICES=0003 Class B, CAN/CSA-C22 2 ND. 1071•07 - This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer's instructions. 1. No enforced DUAC ratio. Seethe compatibility calculator at ht s-/Ie hase..om/en- ,°/support/module-comeat'h-Itty. 2. Nominal voltage range can be extended beyond nominal if required by the utility. 3. Limits may vary. Refer to local requirements to define the number of microtnverters per branch in your area. To learn more about Enphase offerings, visit enphase.com © 2018 Enphase Energy. All rights reserved. All trademarks or brands used are the property of Enphase Energy, Inc. 2018-05-24 ENPHASE. ®aaw IRONRIDGE XR Rail Family XR Rail Family Solar Is Not Over their lifetime', solar panels experience countless extreme weather events. Not just the worst storms in years, but the worst storms in 40 years. High winds capable of ripping panels frojn at roof, and snowfalls weighing enough to buckle a panel frame. XR Rails are the structural backbone preventing these results. They resist uplift, protect against buckling and safely and efficiently transfer loads intd the building structure. Their superior spanning capability N- } requires fewer roof attachments, reducing the numper of roof penetrations and the amount 'r of installation time. Cornpatiblwwith Flat &Pitched Roofs XR Rails are competiblewith FlashFootand taG7GE otheipitchedraof •altachments:. Force Stabilizing Curve Sloped roofs generate both vertical and lateral forces ommounting rails which can cause them. to bend and twist. The curved shape of-XR Rail; directions while resisting the twisting. This unique feature ensures greater security during extreme weather and a longer system lifetime. ironRidge offers. 8 range of tilt leg options for flat Mqm;•roof mounting appllcetlons; Corrosion Resistant Materials All xR Rafts are made of 6000 series -..° alummumalloy then protected with an anodized finish. Anodizing prew3nts surface and siiuctural corrosion; while -also providing r,,! a more attractive'appearance. _ The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. XR10 XR10 is a sleek, low -profile mounting rail, designed for regions with light or no snow. It achieves 8 foot spans, while remaining light and economical. 8'spanning capability Moderate load capability Clear R black anodized finish Internal splices available Rail Selection XR100 is the ultimate residential mounting rail. It supports a range of wind and snow conditions, while also maximizing spans up to 8 feet. • 8'spanning capability • Heavy load capability • Clear & black anodized finish • Internal splices available XR1000 XR1000 is a heavyweight among solar mounting rails. It's built to handle extreme climates and spans up to 12 feet for commercial applications. • 12'spanningcapability • Extreme load capability • Clear anodized finish • Internal splices available The following table was prepared in compliance with applicable engineering codes and standards. Values are based on the following criteria: ASCE 7-10, Roof Zone 1, Exposure B, Roof Slope of 7 to 27 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed span tables and certifications. 10fY' 120. None i40.' XR70 XR10D.XRi000+. loo 102Q .140r ,i -- 100 t r 30- - 1,fi0, 1100 40 160- , 80:90 160,=