Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Plot Plan
PROJECT DESCRIPTION: 70x335 LG335NIC-A5 (335W) MODULES ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES SYSTEM SIZE: 23.45 kW DC STC ARRAY AREA #1: 313.48 SQ FT. ARRAY AREA #2: 405.68 SQ FT. ARRAY AREA #3: 405.68 SQ FT. ARRAY AREA #4: 165.96 SQ FT. EQUIPMENT SUMMARY 70 LG335NIC-A5 (335W) MODULES 70 ENPHASE IQ7-60-2-US MICROINVERTERS GOVERNING CODES: FLORIDA RESIDENTIAL CODE, 6TH EDITION 2017 (FRC) FLORIDA PLUMBING CODE, 6TH EDITION 2017 (FPC) FLORIDA BUILDING CODE, 6TH EDITION 2017 EDITION (FBC) FLORIDA MECHANICAL CODE, 6TH EDITION 2017 (FMC) NEC 2014 CODE BOOK ROOF #4 (09) LG335NIC-A5 (335W) MODULES ST.LUCIE COUNTY ROOF #3 PLAN REVIEW (22) LG335NIC-A5 (335W) MODULES (E) STRUCTURE --I IBLDG: — 632'-711 DATE{: ELE/ED DATE/ u PLUMB: DATE: MECH: I DATE `n 308'-8" I (N) MAIN DISTRIBUTION PANEL 632'-711 ROOF #1 (17) LG335NIC-A5 (335W) MODULES ROOF #2 (22) LG335NIC-A5 (335W) MODULES W e IS 1 PLOT PLAN WITH ROOF PLAN A-00 SCALE: 1/32" = V-0" SHEETINDEX A-00 PLOT PLAN & VICINITY MAP A-01 SYMBOLS & SYSTEM DESCRIPTION S-01 ROOF PLAN & MODULES S-02 STRUCTURAL ATTACHMENT DETAILS E-01 ELECTRICAL LINE DIAGRAM E-02 WIRING CALCULATIONS E-03 SYSTEM LABELING DS-01 MODULE DATA SHEET DS-02 INVERTER DATA SHEET DS-03 RAIL DATA SHEET DS-04 ATTACHMENT DATA SHEET e— N 252'-2" 1-STORY HOUSE I I I� O r-nn z rn z 2 HOUSE PHOTO _ A-00 SCALE: NTS ( — PROJECT SITE ' tf II •. 1r1 �i -J%0 - __T_ FEXISTING DRIVEWAFRONT `�' ( SIDES C>RS! ES REAR 4'JorgI ens i eIi .' o7gk`--Whitecltf P6r e 4t RECEIVED ST, Lucie County, Permitting COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC 3 VICINITY MAP A-00 t511111111[1 '.Indlan River Estates I. SCALE:NTS Castillo rr(� Engineering (GO, DESIGNED IO •FgMIiF CASTILLO ENGINEERING SERVICES, LLC wA4] 5 2925 W. STATE ROAD 434, SUITE 111 LONGWOOD, R 32779 MU(GOtf}B 71 ERMOLIigTES E. GSTIU.O-FL PE III REVISIONS DESCRIPTION DATE REV PROJECTINSTALLER SUNPRM EN F lj o .^1 r. TATE OFF U `' z w o00 W J LLI rn LL Of Z LL 0, Of � 0 uJ eLL _ -�t ly U 'qOO O LL T^ t� n qn q 1icV V 6 LJ�J SHEET NAME PLOT PLAN & VICINITY MAP SHEETSIZE ANSI B 11" X 17" SHEET NUMBER A-00 Symbols: Sheet where Section .............. / X \section is located x-xx Detail ID Letter Elevation ........... Sheet where x-xx section is located Detail ID Letter Detail ................ x x- Sheetwhere section is located Detail ID Letter Detail ............... x f Area to be enlarged (Enlarged Plan) x-p1 Sheet where section is located Keyed Notes .......... 1 Keyed note designation on applicable sheet Ground Terminal..... Q Grounding Point/rod.... -6 Solar Panel ......... or OO----Module with Source Circuit number Combiner Box.......... CB DC Disconnect.......... DCD Main Distribution MDP Panel...................... Fuse ...................... Overcurrent Breaker.. — Inverter .................... Transformer ............. F Automatic ............... ATs Transfer Switch Abbreviations: AC Alternating Current APPROX Approximate AWG American Wire Gauge CB Combiner Box DC Direct Current DCD Direct Current Disconnect DISC Disconnect (E) Existing EL Elevation EQ Equal JB Junction Box MCB Main Combiner Box MFR Manufacturer MIN Minimum MISC Miscellaneous (N) New OCPD OverCurrent Protection Device POCC Point Of Common Coupling PV Photovoltaic SF Squarefoot/feet STC Standard Test Conditions TBD To Be Determined TYP Typical VIF Verify In Field WP Weather Proof System Description This system is a grid -tied, PV system, with PV generation consisting of 70 LG335NIC-A5 (335W) MODULES with a combined STC rated do output power of 23,450W. The modules are connected into 70 ENPHASE IQ7-60-2-US MICROINVERTERS. The inverter has electronic maximum power point tracking to maximize energy captured by the PV modules. The inverter also has an internal ground fault detection and interruption device that is set to disconnect the array in the event that a ground fault that exceeds one ampere should occur. The inverter has DC and AC disconnect integrated system and labels are provided as required by the National Electric Code PV Modules Microinverters--lo Junction Point of O Box Utility Connection Utility Meter When the sun is shining, power from the PV array is fed into the inverter, where it is converted from DC to AC. The inverter output is then used to contribute to the power requirements of the occupancy. If PV power meets the requirements of the loads of the occupancy, any remaining PV power is sold back to the utility. When utility power is available, but PV power is not available, building loads are supplied by the utility. The inverter meets the requirements of IEEE 1547 and UL 1741. This means that if it detects a loss of utility power, it will automatically disconnect from the utility. When utility voltage is restored, the inverter automatically reconnects to the utility grid after verifying utility voltage and frequency stability. On a day with average Florida sunshine, this system outputs 100.03 kWh per day on site. COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC Castillo Engineering Col DE".." TO PPRMIT• CASTILLO ENGINEERING SERVICES, LLC WAOIl 5 M25 W. STATE ROAD 434, SURE111 LONGWOOD• FL 32TJ9 ML: C.?)nH Z's ERM AnMEG ILLO-RPE5 m REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER SUNPR.- N 5259 STA O Urt � Z' UJ o0. ZM W J W co Lt_ ZLL W U C� O owa L.L F 2 v� U �0 O Of CV 0 6'2913 SHEET NAME SYMBOLS & SYSTEM DESCRIPTION SHEETSIZE ANSI B 11" X 17" SHEET NUMBER A-01 MODULE TYPE. DIMENSIONS & WEIGHT NUMBER OF MODULES = 70 MODULES MODULE TYPE = LG335NIC-A5 (335W) MODULES WEIGHT = 39.68 LBS / 18 KG. MODULE DIMENSIONS = 66.4" x 40" = 18.44 SF UNIT WEIGHT OF ARRAY = 2.15 PSF ARRAY & ROOF AREA CALC'S (ROOF #1) ARRAY AREA = 165.96 SO. FT. ROOF FACE AREA = 313.48 SQ. FT. 313.48 / 519.09=60.39% OF ROOF FACE AREA COVERED BY ARRAY DESCRIPTION (ROOF #1 ROOF TYPE - METAL ROOF ROOF TILT -22.6° ROOF AZIMUTH - 90° SEAM SPACING - @ 16" O.C. ARRAY & ROOF AREA CALC'S (ROOF #2) ARRAY AREA = 405.68 SQ. FT. ROOF FACE AREA = 742.19 SQ. FT. 405.68 / 742.19 = 54.66% OF ROOF FACE AREA COVERED BY ARRAY DESCRIPTION (ROOF #2 ROOF TYPE - METAL ROOF ROOF TILT - 22.6° ROOF AZIMUTH -182° SEAM SPACING - @ 16" O.C. (E) UTILITY METER (N) MAIN DISTRIBUTION PANEL (N) AC DISCONNECT (IF REQUIRED BY UTILITY) (N) PV METER (IF REQUIRED) (N) ENPHASE IQ COMBINER BOX ROOF#1 (17) LG335NIC-A5 (335W) MODULES ROOF #3 LG335NIC-A5 (335W) MODULES WIND ZONE 3 (TYP.) PLAN & MODULES S-01 I SCALE: 1/16" = V-0" COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC GENERAL INSTALLATION PLAN NOTES: (1) ROOF ATTACHMENTS TO SEAM SHALL BE INSTALLED AS SHOWN IN SHEET S-02 AND AS FOLLOWS FOR EACH WIND ZONE:. WIND ZONE 1: 48" O.C. WIND ZONE 2: 16" O.C. WIND ZONE 3: 16" O.C. SEE SHEET S-02 FOR SUPPORTING CALCULATIONS. 4) EXISTING RESIDENTIAL BUILDING IS A METAL ROOF WITH MEAN ROOF HEIGHT 15FT AND SEAM SPACED 16" O.C. EXISTING ROOF SLOPE FOR SOLAR SYSTEM RETROFIT IS 22.6 DEGREES. CONTRACTOR TO FIELD VERIFY AND SHALL REPORT TO THE ENGINEER IF ANY DISCREPANCIES EXIST BETWEEN PLANS AND IN FIELD CONDITIONS. I CERTIFY THAT THE INSTALLATION OF THE MODULES IS IN COMPLIANCE WITH FBC: RESIDENTIAL CHAPTER 3. BUILDING STRUCTURE WILL SAFELY ACCOMMODATE LATERAL AND UPLIFT WIND LOADS, AND EQUIPMENT DEAD LOADS. - ROOF #4 0 TILT - 22.6" AZIM.-92" ROOF #4 (09) LG335NIC-A5 (335W) MODULES (230) PV ROOF ATTACHMENT @ 16" & 48" 0. C. MAX (N) (70) ENPHASE IQ7-60-2-US MICROINVERTERS (N) UNIRAC RAIL (TYP.) ARRAY & ROOF AREA CALC'S (ROOF #3) ARRAY AREA = 405.68 SQ. FT. ROOF FACE AREA = 1126.13 SQ. FT. 405.68 / 1126.13 = 36.02% OF ROOF FACE AREA COVERED BY ARRAY DESCRIPTION (ROOF #3 ROOF TYPE - METAL ROOF ROOF TILT -22.6° ROOF AZIMUTH -272' SEAM SPACING - @ 16" O.C. ROOF #2 (22) LG335NIC-A5 (335W) MODULES ARRAY & ROOF AREA CALC'S (ROOF #4) ARRAY AREA = 165.96 SQ. FT. ROOF FACE AREA = 589.66 SQ. FT. 165.96 / 589.66 = 28.15% OF ROOF FACE AREA COVERED BY ARRAY DESCRIPTION (ROOF #4 ROOF TYPE -METAL ROOF ROOF TILT - 22.6" ROOF AZIMUTH - 92D SEAM SPACING - @ 16" O.C. rn /70 O z 7u '�• - = 40" - c6 CD LG335NIC-A5 (335W) MODULI LEGEND ©M - UTILITY METER SD-SOLADECK INV -INVERTER ACD -AC DISCONNECT PM - PRODUCTIONMETER MDP - MAIN DISTRIBUTION PANEL O - VENT, ATTIC FAN (ROOF OBSTRUCTION) O - PV ROOF ATTACHMENT —-SEAMSS -CONDUIT CB -COMBINER BOX Castillo Engineering G DEEIOMED LO !E{MITe CASTILLO ENGINEERING SERVICES, LLC con#mus M6 W. STATE ROAD 434, SUITE 111 LONGWOOD,F 32M 1EL(w7 My 75 FRMO..A E, fl5TLL0-FL PE K. REVISIONS DESCRIPTION DATE REV PROJECTINSTALLER SUNPRCUM �!\I / ea[ `• G /4 'II E Ng' No 90 ATE 0 : 4ij ""Wit "Wi U z W CO Z M W -J W co LL. Z LLI LU U O 0LU a _ * fy U IO rich o 6' 2913 SHEET NAME ROOF PLAN & MODULES SHEET SIZE ANSI B 11" X 17" SHEETNUMBER S-01 T-4" SEAM SPACE I — 4'-0" (TYP.) ZONE 1 ATTACHMENT DETAIL S-02 I SCALE -1" = V-0" S-5-N Units are Inches with mm in brackets (N) UNIRAC RAIL (2x) M8-1.25 Threaded Hole General Notes: 1. S-5-N Clamp 2. S-5-N Insert 3. M8.1.25 SS Hex Flange Bolt (13mm Socket) 4. 318-24 SS Round Point Setscrew (3116 Hex Drive) 5. Example Roof 2 ATTACHMENT DETAIL S-02 SCALE -1/4" = V-0" 3 D6N �. 2 � 2. (N) END CLAMP 1" S-5-N CLAMP 318-24 SS ROUND POINT SETSCREW COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC 130, - 120 Lis 1 115. ice 130... v. 4Y 140 V y, b 140 34e - 1 1 v 1un•v. uPt.ao a flpis uf.,q 150 - . 'Nm fpeei.l -11 R �emlf4Fl of 9 t` ,, - 179. It (SY) iWv Fovw 1 "l.7 C e1 b: i 2 afn.:..f.tofpmml bd... m. ` 160 'm _ 'mad w t' Dr •. t fL �ariea. wu Ib lfit .1m ftebi ' 170. °a•" _ 4nmV eftb fill Y! ' 14 fPuotafmof p tl LdBb - Eemubr]ei. ene petlb tlu! redm "told b �md 1 W a mf 1 380 . 5 t xfvd aP.d. Pmd to . - to 1L'MahWILly Msaml®.e.i. SD.ye :.. I tbvm.l Ei[.ibnb puCM1tEY - B.L¢lU _ .. qL rLO�rfM) t FIGURE 1609.0ti) ULTIMATE DESIGN WINDSPEEDS Vuv,FOR RISK CATEGORY 11 BUILDINGS AND OTHER STRUCTURES - Wind Speed Ult(mph) S16D Risk Category �11 Wind Speed ASD(mph) 330 Exposure Category C Mean Roof Height (ft E35 Roof Slope (degrees) �357 Module Area (sq ft) 20 Kzt — 1 Helght Ad)ustment Factor,h 1:21 Mkoof Zone Pnef(30)=: 1 16 1 -27 2 16 -44.6 3 16 67 P- Let=KAK]-ztP-(net(30)) 11rr,ROof Zone. P,net 1 19.36 -32.67 2 19.36 -53.966 3 19.36jV-S]tT07jq Maximum Uplift per `fastener Wind Zone 1 359.4' Allowable Up. Load of S-5-N Bracket perS-5 test report 369 • Roof attachmentsw 2miIs at inches O/C Maximum Upliftper 'fastener Wind Zone 2 1979 Allowable Up Load ofS-5-N Bracket per5-Stest report 369 • Roof attachmentsw 2rallsat-l6 inches O/C Maximum Uplift per 'fastener Wind Zone 3 2973 Allowable Up Load of S-S-N Bracket per5-Stest report 369 ' Roof attachments w 2 rails at 46, inches O/C *21 Castillo Engineering Y1514NED To PERMIT. CASTILLO ENGINEERING SERVICES, LLC COAdaB 2925 W. STATE ROAD 434, SURE 111 LONGWOOD, R3W79 1E1.:(407)] 75 E WACCMiES E C4STLL0-FL FE G]590 REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER SUNPR W.wwal itJ E;......... <o No 2590 S ATE *:4:' dB@ A• •'era S� NA1-E��`�� • rLLLLI fit it, U LLI p 00 Z M W -1 LU fn LL Z LLI W C) (9 O W � d LL U (OTO Of Picv 0 6' 2013 SHEET NAME STRUCTURAL ATTACHMENT �113 SHEET SIZE ANSI B 11" X 17" SHEET NUMBER S-02 I I I I QCABLES (N) SOLADECK 60O V, NEMA 3R ULLISTED PRODUCTION CT (3) #10 AWG THWN-2 (3) #10 AWG TH WN-2 (1) #10 AWG THWN-2 GND (N) (3) 3/4" PVC OR EMT CONDUIT RUN (2) #10 AWG TH WN-2 (2) #10 AWG THWN-2 (1) #10 AWG THWN-2 GND (N) (3) 3/4" PVC OR EMT CONDUIT RUN (N) PV COMBINER BOX 24OV, 125A/2P NEMA 3R, UL LISTED 20A/2P L2 20A/2F 9L, L2 L— — — — — — — — — — — — — — — — ELECTRICAL LINE DIAGRAM E-01I SCALE: NT£ (N) PV METER (IF REQUIRED) (3) 94 AWG THWN-2 (1) #8 AWG THWN-2 GND IN 1" PVC OR EMT CONDUIT RUN SOLAR ARRAY 23.45 kW -DC STC) (70) LG335N1C-A5 (335W) MODULES (5) STRING OF 14 MODULES NOTE: 1. SUBJECT PV SYSTEMS HAS BEEN DESIGNED TO MEET THE REQUIREMENTS OF THE NEC 2014, AND THOSE SET FORTH BY THE FLORIDA SOLAR ENERGY CENTER CERTIFICATION, INCLUDING MAXIMUM NUMBER OF MODULE STRINGS, MAXIMUM NUMBER OF MODULES PER STRING, MAXIMUM OUTPUT, MODULE MANUFACTURER AND MODEL NUMBER, INVERTER MANUFACTURER AND MODEL NUMBER, AS APPLICABLE. 2. PROVIDE TAP BOX IN COMPLIANCE WITH 312.8 IF PANEL GUTTER SPACE IS INADEQUATE. ENPHASE IQ7-60-2-US MICROINVERTERS PV MODULES (N) AC DISCONNECT: 240V, 100AMP, FUSED NEMA LINE SIDE TAP USING 3R,UL LISTED ILSCO KUP-L-TAP INSULATION WITH 90A FUSES VISIBLE PIERCING CONNECTORS LOCKABLE AND LOCATED ON ACCESSIBLE EXTERIOR WALL WITHIN 10 CONSUMPTION CTS FEET OF OF UTILITY R (IF REQUIRED) (4) #18 AWG THWN-2 IN 1/2" PVC OR EMT/ROMEX CONDUIT RUN (3) #4 AWG THWN-2 IN 1" PVC OR EMT CONDUIT RUN Yf41�[e1111i) —CBI-DIRECTIONAL I /\/\I UTILITY METER 1-PHASE, 240V _ (N) MAIN DISTRIBUT! PANEL, 225A RATED, 240V. (N) MAIN BREAKER 200A/2P. 240V EXISTING GROUNDING ELECTRODE SYSTEM COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC Castillo Engineering o[sicn[o io newer. CASTILLO ENGINEERING SERVICES, LLC WA 28.5 M5 W. STATE ROAD 430, SUITE 1H LONGWOOD. FL 3V79 FAMOCIN E.G TILLO -R PE U2 REVISIONS DESCRIPTION DATE REV PROJECTINSTALLER SU,NPR=0 IIIIIP �' • • lira . N �. No 5 590 F = * •r TATE F 4 !!!! n111N1\\ U z � LLI 0 00 M LLI J Lu Cn U- Z LLI LLI 0 0 0 W O �a LL. 2 vw U v0 0 ILL. NCV 0 6' 2013 SHEET NAME ELECTRICAL LINE DIAGRAM SHEET SIZE ANSI B 11" X 17" SHEET NUMBER E-01 AC CONDUCTOR AMPACITY CALCULATIONS FROM ROOF TOP SOLADECK TO LOAD CENTER MODULE. MANUFACTURER LG MODULE MODEL_ - LG335N 1 C-A5 INVERTER MANUFACTURER ENPHABE INVERTER MODEL ENPHABE IQ 7 MODULES/BRANCH CIRCUIT 1. ._ P4 MDDULES/BRANCH-CIRCUIT 2 14 MODULES/BRANCH CIRCUIT 3 _ 14 MODULES/BRANCH CIRCUIT 4 _ 14 MODULES/BRANCH CIRCUT & 14 TOTAL.ARRAYPOWER IKW)' 23.45 6YBTEM'AC VOLTAGE 240V 1-PHASE OESISN� TEMPERATURE MIN. AMBIENT TEMP. -F 32 MAX. AMBIENT TEMP. -F 1 1 7 CALCULATED MAX. VDC 44 _ CALCULATED MIN VMP 27 CONDUIT FILL NUMBER OF CONDUITS 2 AMPACITY CALCULTIONB AC CONDUCTOR AMPACITY CALCULATIONS: FROM AC COMBINER BOX TO MSP MODULE PROPERTIES _ VOC 41 _ )BC 10.49 VMPP 34:1 IMP 9.83 TC VCC -0.27%1°0 TC VMP ,.-0.37%/00 PmP 335.0 NOCr 1 45_°0 INVERTER PROPERTIES OUTPUT VOLTAGE _-' 240. L-L 1 -PH M Ax INPUT Oc VDLTAGE 4B VDC. OPERATING RANGE 1 6 - 4S VDC MPPT VOLTAGE RANGE 27---37 VDC _ START VOLTAGE 22 VDC MAX INPUT POWER' _-_35O-WOC- CONTIN000B AC POWER 240 VA 1.25 X 9010 AMBIENT TEMP CONDUIT FILL MAXIMUM CIRCUIT CIRCUIT MAX AMPS AWG MA% AMPS AMPACITY TEMP 'F DEBATE FILL DEBATE BREAKER CIRCUIT 1 14.0 17.5 #10 40 130 0.76 5 0.8 20�A CIRCUIT 2 14.0 17.5 #1❑ 40 1SO 0.76 5 0.a tAMFACI� 20. A.CIRCUIT 3 14.0 17.6 #1❑ 40 1,30 0.76 5 0.a 20 A CIRCUIT 4 14.0 1 R - #1❑ 40 _ ISO 076 5 O.B 20 A 1 Z4..32 CIRCUIT 5 14.0 17.5 #10 40 130 0.76 5, O.B 20 A AD CDMBINER PANEL OUTPUT ,TOO 17.5 #4 95 95 0.96 3 1 1.2. A 9❑ - - MAXIMUM, CIRCUIT VOLTAGE DROP- -- S ZiS VOLTAGE_OROP. CALCULATIONS'_ CIRCUIT AWG CIRCULAR MILLS I V MAX LENGTH CIRCUIT 1 #10 10380 14.0 240 M113MV CIRCUIT 2 #1 0 10380 14.0 240 1 30 FjEE, CIRCUIT 3 # 10 10380 14.0 240 1 3S Fe ET CIRCUIT 14 #10 1O3BO 14.0 240 1 er COMBINER PANEL OUTPUT #4 41740 70.0 240 NOTES TEMP BERATE BARED ON NEC TABLE 310.15(8)(2)(A) CONDUIT FILL BERATE BARED ON NEC TABLE 3.I 0.15(B)(3)(A) MAXIMUM VOC CALCULATED USING MODULE MANUFACTURE TEMPERATURE COEFFICIENTS PER NEC 690.7(A) UNLESS OTHERWIBE SPECIFIED, ALL WIRING MUST BE THHN OR THWN-2 COPPER ALL WIRE SIZES LISTED ARE THE MINIMUM ALLOWABLE IN ANY CELL INDICATES THAT THE SYSTEM 15 SAFE AND COMPLIES WITH NEC REgUIREMENTS IN ANY CELL INDICATES A POTENTIALLY UNBAFE CONDITION INFORMATION. INPUT BY SYSTEM DESIGNER INFORMATON OBTAINED FROM MANUFACTURER DATABHEETB COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC ELECTRICAL NOTES 1. ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2. ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT.THE TERMINALS ARE RATED FOR 75 DEGREE C. 3. THE WIRES ARE SIZED ACCORDING TO NEC 110.14. 4. WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 5. WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. 6. DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 7. WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 8. ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 9. MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 10. MODULE SUPPORT RAILTO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY -IN LUG. 11. THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE. 12. UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. 13. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. 14. RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. 15. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE 310.10 (D). 16. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C). ENPHASE IQ7-60-2-US MICROINVERTER Input Data (DC) " Recommended Input Power (STC) 235-35OW + Maximum Input DC Voltage 48V Peak Power Tracking Voltage 27V-37V Operating Range 16V-48V Min. / Max. Start Voltage 22V / 48V Max DC Short Circuit Current 15A Output Data (AC) Maximum Output Power 24OW Nominal Output Current 1.OA Nominal Voltage / Range 240V/211-264V Nominal Frequency / Range 60 Hz Extended Frequency / Range 47-68 Hz Power Factor at rated power 1.0 Maximum unit per 20A Branch Circuit 16 (240 VAC) Engineering D IH G NfO TO F[v.U. CASTILLO ENGINEERING SERVICES, LLC c .241l 5 2925 W. STATE ROAD 4M. SURE 111 LONGWOOD, R 32179 TEI:(dCAS0])183 " ERMOG9FTE5 E TLLO � FL P E 52550 REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER SUNPR �'�,�C NSF'•. o 52590 STATE • E(`'T ••\ram` P- U Z LU .- O 00 M Z W -.1 LLJ Cn U- Z LLA W U '^ D' V W O O IL U (TOO LL O � LL T IVAME WIRING CALCULATIONS SHEETSIZE ANSI B 11" X 17" SHEET NUMBER E-C ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: AC DISCONNECT, POINT OF If PER CODE: NEC 690.17(E), CB LABEL LOCATION: CONDUIT, COMBINER BOX (PER CODE: NEC690.31(G)(3)(4) & NEC 690.13(G)(4) CONI- TOUOL•TAIC1BYSTE. LABEL LOCATION: POINT OF INTERCONNECTION (PER CODE: NEC 705.12(D)(4)) ADHESIVE FASTENED SIGNS: • THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED. • WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNINGS, AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4 [NEC 110.21(B) FIELD MARKING). • ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT IIFC 605.11.1.3] (PER CODE: NEC690.54) LABEL LOCATION: POINT OF INTERCONNECTION (PER CODE: NEC 705.12(D)(7)) [Not required if panelboard is rated not less than sum of ampere ratings of all overwrrenl devices supplying it] DATA PER PANEL LABEL LOCATION: COMBINER BOX (PER CODE: NEC690.52) INTERCONNECTION (PER CODE: NEC690.56(C)) COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC Castillo Engineering D ISIGN rD —0. —MI 1• CASTILLO ENGINEERING SERVICES, LLC c 4VMS 2925 W. STATE ROAD 4M. SURE 111 LONGWOOD, FL M779 T -(m9m ZTS ERMOCP MEGA ILLO-FL PE W REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER SUINPRO 1 No 5 590 A E GI LLI r 0 00 0' M 12 CO LU J LLI coLL 12f Z LLI 0 W �a � 2 v� U WoO LL O 'CV 0 6 2013 SHEET NAME SYSTEM LABELING SHEET SIZE ANSI B 11" X 17" SHEET NUMBER E-03 LG335N1C-A5 I LG330NIC-AS I LG325N1C-AS 335W 1330W 1325W The LG NeONO 2 is LG's best selling solar module. It received the acclaimed 20151ntersolarAWARD for featuring LG's Cello Techno that increases its power output and reliability making it one of the powerful and versatile modules on the market & `In ek- C E ff®w Feature 60 II I I 1,1 II t I• ,I � i' E�- Enhanced Performance Warranty LG NeONO 2 has an enhanced performance ® High Power Output Compared with previous models, the warranty. After 25 years, LG NeONO 2 is guar- LG NeON8 2 has been designed to significantly anteed at least 84.8% of initial performance. enhance its output efficiency making it efficient even in limited space. Aesthetic Roof LG NeONO 2 has been designed `°` Outstanding Durability With its frame design, LG �J with aesthetic \ newly reinforced in mind; thinner wires that appear all black at a has extended the warranty of the NeONG' distance. The product can increase the value of 2 for an additional 2 years. Additionally, LG a property with its modem design NEW 2 can endure a front load up to 6000 Pa, and a rear load up to 5400 Pa. Better Performance on a Sunny Day - LG NeONO 2 now performs better on a sunny days thanks to its improved temperature coefficient 12 Near Zero LID (Light Induced Degradation) The n-type cells used in LG NeONO 2 have almost no boron, which may cause the initial performance degradation, leading to less UD. About LG Electronics IGaeNvuslaa9�>1 N9PMieEmvmilndN.�glMe�n�A„m>amm�.,k�yM,<em6�m.�P�w�m�6�.m Wf.,we'Swsayatt¢btlesN'mx5N-e1CD.,tiviimyaNm3mW[MM1eMM62%g1G5ndwn s ®LG WAGGVKV h 20Made MOMWGwrtn[d1ry uMmtlemakt Mlkl,bma LW M]2mmvuTUNeW.(p.wlsA4 W<NtONJ.[kRPI,NSONs2&fiSWIem,WNm601mAWNA'In]013.2015 .m xms,..isd,m�w�ale.I6swanuee.wwamlm�mmm�tmu<wlnvy LGSGSGONLNelaL2-60SIxW..4 1 2017-05-23 Sis LG NeON®2 LG335N1C-AS I LG330N1C-AS ILG325N1C-AS MPrAPnirPl PnnPltiac Ieege 6x10 ICezvn IS i CerType_ Ma,vgybtMrc/Ntype IWD1mm9m¢ _ 161Ax1611mm/6W I•e4a1 12(MWtlW BI¢Wr) j 0lmnams(Lx WxIu 1,666x1A16x40mm 6fi38x40x1571n I Fmntlna6. 6,000N/125yr Mee Wd - 5ADCPa/113p4 IWegh, 18kgf39530 iCuumtvType Mc,(MQ kn,cmn &n IP ZIDryfls Dbhi 1G1- 1,ODD.x2-/3937n.2. I EDGE - - - - ighT2nvnSlm,TemlgNGl i frame NOTaM A1mvium CPrrifiaHnnc and Wamamv - CeniFatimis IEC61115,-MC61730-1/-2 Rl]03 EC 61]01 (SaO,m[m,mslontenl ¢C 62Tfi (Pmnmlam,tosimtest) 609001 IMo&u Fi PeAgmvve TyMI(M 1]03) I Fim ft*, ENOS C (UIC MC 1703•U 61]3D) 1pO wiirmty 12W. Out,RG ntydf L w y, •I)IS" 11/am'Ialzzufaxmamgamn4)wmm 2syem Temperature Characteristics I NOR- au] It. I[1E,Y] oD3 Characteristic Curves w N Ia IA x ED M ------._._...----..... — @ 8 D E 9 A 9 ® LG 1 WTWD Saa fiusness OMam Ili xM ivxu; 28 Ytglbxro, Vmghulgpoyµ Rwl W's Good 0)336, Yp® WMWg�xlval0 Lr>_6peccheLNoon26p_Bleckh4me.NEtl 2 Electrical Pmoerties(STC-) MWe1lU233SNICAS If.3 W0 A5 16325NICAS) IMaralnvnPmr(Pmai) lWlL335 330 325 M(Vmpp)M 33TjMPPlMpp) [A]991 4T) M409 408 [A]10A5 1041 193 19D I OpcaWgTelryleatue IY7 -00-.90 I Matil^w4iunn VaM9e M lam(DL/Itq i Mani.lmse4¢r,ee anmlg [A] 20 FP Tdvars [%]. 0-•3 slel5tm4NTeat redltbnTlltesela loo0w/m`. uOmWermre35•GAM is M,ImLylatepawtu[prtkmeauM W Ennm4e16YIDFb,mue[In WevtlebWae ®aun 111e7yJNtMyad,rvMle erM15ert1rt300 W/m'nrtlNnm 10XI W/m`h30f Fb.ed.el0.n..eaee /mni-rm M I ID335N1LA_5 L0330N1GA3 1G325NIOA51 IMaMwniP—irPmax) iW] 24] M3 240 IMPPWSSPrvDpp) _ M 315 311 303 IMPPOmert") .[A] 3B3 781 7.70 !apes ametvdtagei ).. M. 333 Sal 3a0 I51mrt OmuTGmm[Ilu). _ (A] a44 841 839 -le,u Irmwµermxl9 uv u^Prm°eFvrmamewrv/m'.Pmv¢mlwame El; mktlpm4l mM1 Dimensions (mm / inch) "Ll •lhe4ktzm4wm W waartW nrtntl'9/91.IMu9 PreActspalf unf ae sugtttm dlml9e wltluutmtla. ❑� *0 OSNSiO{L-f-EN-T0521 ; m2m]IGF4 vmtr AdtgM1tzmSerrtA ❑ • 201T-0 n Castillo (� Engineering DESIGNED To PERMIT' CASTILLO ENGINEERING SERVICES, LLC COAY293a5 1211. STATE ROAD 4M, SUITE ill LONGWOOD. FL 32]]9 TEL(07)2 2575 MMOC TES E(WMT O - FL PE 52590 REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER S U� N PR��-• ��:•GENS. O No 52 0 tr S ATE F .411 • EG. s4 E.. et Q/ �/ 1 111t1S U W Q 00 Z W J W fn LL Z LLI 0 CW7 C.) O W LL O d NU (DLL O Of NCU 0 6 2913 SHEET NAME MODULE DATA SHEET ESHEET SIZE ANSI B 11" X 17-1 SHEET NUMBER DS-01 Data Sheet Enphase Microinverters Region: US Enphase IQ7and IQ7+ Microinverters UL BE To learn more about Enphase offerings, visit enphase.com The high-powered smart grid -ready Enphase IQ 7 Micro'" and Enphase IQ 7+ Micro' dramatically simplify the installation process while achieving the highest system efficiency. Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate seamlessly with the Enphase IQ Envoy'", Enphase Q Aggregator"', Enphase IQ Battery'", and the Enphase Enlighten - monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power -on testing, enabling Enphase to provide an industry -leading warranty of up to 25 years. Easy to Install • Lightweight and simple • Faster installation with improved, lighter two -wire cabling • Built-in rapid shutdown compliant (NEC 2014&2017) Productive and Reliable Optimized for high powered 60-cell and 72-cell* modules More than a million hours of testing Class II double -insulated enclosure UL listed Smart Grid Ready Complies with advanced grid support, voltage and frequency ride -through requirements Remotely updates to respond to changing grid requirements Configurable for varying grid profiles Meets CA Rule 21 (UL 1741-SA) =The IQ 7. Micro is required to support 72-cell modules. ENPHASE. Enphase IQ 7 and IQ 7+ Microinverters used module Moauie compatmuny bu-cell Pv modules only 50-cell and 72-cell PV modules I Maximum input DC voltage , 48V Peak power tracking voltage 27737V 27V-45V Operating range � 16V-46V 16V-60V � 1 _ Min/Max start voltage _ 22V/46V 22V/60V Max DC shot circuit current(modulelsc) A__ Overvoltage class DC port _15 11 II PV array configuration 1 x 1 ungrounded array; No additional DC side protectic AC side protection requires max 20A oar branch circuit I power [4U VA 29U VA -- 24OV/ '208V/ 24OV/ 208V/ — --�- 211-264 V 183-229 V_ 211-264 V 183-229 V_ I current 1.0A _ 1.15A 1.21A _ 1.39A___ _ 60 Hz 60 Hz _ _ _ 47-68 Hz _ _ _ 47-68 Hz —l--'--- Maximum units per 20 A ILL) branch circuity 16 (240 VAC) 13 (240 VAC) 13 (208 VAC) 11 (208 VAC) COvervoltage class AC port III III AC port backfeed current 0A� 0A Power range Pollution degree 0.7 leading... 0.7 lagging 0.7 leading... 0.7 @240 V @208 V @240 V 97.6% 97.6% 97.5% 97.0 % 97.0 % 97.0 % IQ 7 Mlcrolm enter -40-C to+65^C 4%to 160%(condensing) MC4 (or Amphenol H4 UTX with additional Q-DCC-5 at 212 mm x 175 mm x 30.2 rum (without bracket) 1.08 kg (kg 23616s) Natural convection -No fans Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. means Compliance CA Rule 21 (UL 1741-SA) UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when Installed according manufacturer's instructions. 1. No enforced DC/AC ratio. See the compatibility calculator at hlip // noha= om7 m=/=ooarymod �l - omoatib'I'ty. 2. Nominal voltage range can be extended beyond nominal if required by the utility. 3. Limits may vary. Rehr to local requirements to define the number of micminverters per branch in your area. To learn more about Enphase offerings, visit enphase.com 0G) EN PHASE. 02018 Enphase Energy. All rights reserved. All trademarks or brands used are the property of Enphase Energy, Inc 2018-02ce Castillo Engineering o E51GNLa TO VieMIT• CASTILLO ENGINEERING SERVICES, LLC COA028- 2925 W. STATE ROAD 4M. SURE 111 LONGWOOD, FL 32779 TEl:1G8212b92ET5 EflMOCRATEa E GSTILLO-FL PE 52i90 REVISIONS DESCRIPTION DATE REV PROJECTINSTALLER RATSE \ / Si yre '\GEN'' �O No 5 0 ATE O 0Wf lee llW%%%`. 0 T Cl I1J 00 Df (3 M W .J W (n L- Z LLI W (� O W ILL U WoO NCV 0 6 2013 SHEET NAME INVERTER DATA SHEET SHEET SIZE ANSI B 1111 X 17" SHEET NUMBER DS-02 UNIRAC ..... ANILIIGRWPLOAIP, SolarMount Technical Datasheet Pub 100602-ltd V1.0 June 2010 SolarMount Module Connection Hardware.................................................................. 1 BottomUp Module Clip.................................................................................................1 MidClamp....................................................................................................................2 EndClamp....................................................................................................................2 SolarMount Beam Connection Hardware......................................................................3 L-Foot...........................................................................................................................3 SolarMountBeams..........................................................................................................4 SolarMount Module Connection Hardware SolarMount Bottom Up Module Clip Part No. 321001. 321002 1�4 Y voo I x 1, Dimensions specified in inches unless noted • Bottom Up Clip material: One of the following extruded aluminum alloys: 6005-T5, 6105-T5, 6061-T6 • Ultimate tensile: 38ksi, Yield: 35 ksl • Finish: Clear Anodized • Bottom Up CUP weight: -0.031 Ibs (14g) • Allowable and design loads are valid when components are assembled with SolarMount series beams according to authorized UNIRAC documents • Assemble with one 1/P-20 ASTM F593 bolt, one 1/7-20 ASTM F594 serrated flange nut, and one flat washer • Use anti -seize and tighten to 10 ft-Ibs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third - party test results from an IAS accredited laboratory • Module edge must be fully supported by the beam * NOTE ON WASHER: Install washer on bolt head side of assembly. DO NOT install washer under serrated flange nut Applied Load Direction Average UlOmate likes (N) Allowable Load Ibs (N) Safety Factor, FS Design Load Ibs (N) Resistance Factor, dt Tension, Y+ 1566 (6967) 686 (3052) 2.28 1038 (4615) 0.662 Transverse, Xt - 1128 (5019) 329 (1463) 3.43 497 (2213) 0.441 Sliding, Zt 66(292) 27(119) 2.44 41(181). 0.619 SolarMount Mid Clamp Part No. 320008, 320009, 320019, 320020, 320021, 320084,320085,320086,320087,320120,320122 I.a00L5TAx@ Y t�x Dimensions specified in Inches unless noted SolarMount End Clamp Part No. 320002, 320003, 320004, 320005, 320006, 320012,320013,320014,320015,320016,320017, 320079,320080,320081,320082,320083,320117, 320118,320123,320124,320173,320185,320220, 320233.320234.320331 vA 1ss MXRWM NFIO1n mrN rmu� rNlaw¢s J— Dimensions spec es d so U N I RAC ANIm GR00P(OMPOfiV • Mid clamp material: One of the following extruded aluminum alloys: 6005-T5, 6105-T5, 6061-T6 • Ultimate tensile: 38ksi, Yield: 35 ksi • Finish: Clear or Dark Anodized • Mid clamp weight: 0.050 Ibs (23g) • Allowable and design loads are valid when components are assembled according to authorized UNIRAC documents • Values represent the allowable and design load capacity of a single mid clamp assembly when used with a SolarMount series beam to retain a module in the direction indicated • Assemble mid clamp with one Unirac W-20 T-bolt and one'/2" 20 ASTM F594 serrated flange nut • Use anti -seize and tighten to 10 ft-Ibs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third - party test results from an IAS accredited laboratory Applied Load Direction Average Ultimate Ibs (N) Allowable Load Ibs IN) Safety Factor, FS Design Load Ibs (N) Resistance Factor, 0 Tension, Y+ 2020 (8987) 891 (3963) 2.27 1348 (5994) 0.667 Transverse, Zt 520 (2313) 229 (1017) 2.27 346 (1539) 0.665 Sliding, Xt 1194 (5312) 490 (2179) 2.44 741 (3295) 0.620 • End clamp material: One of the following extruded aluminum alloys: 6005-T5, 6105-T5, 6061-T6 • Ultimate tensile: 38ksi, Yield: 35 ksi • Finish: Clear or Dark Anodized • End clamp weight: varies based on height: -0.058 lbs (26g) • Allowable and design loads are valid when components are assembled according to authorized UNIRAC documents • Values represent the allowable and design load capacity of a single end clamp assembly when used with a SolarMount series beam to retain a module in the direction indicated • Assemble with one Unirac'/V-20 T-bolt and one''W-20 ASTM F594 serrated flange nut • Use anti -seize and tighten to 10 ft-Ibs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third - party test results from an IAS accredited laboratory • Modules must be installed at least 1.5 in from either end of a beam Applied Load Direction Average Ultimate Ibs (N) AllowablFFactor, Loa Ibs (N Design Loads Ibs (N) Resistance Facto, mTension, Y+ 1321(5876) 529(2352 800(3557) 0.605 Transverse, Zt 63(279) 14(61) 21(92) 0.330 Sliding, Xt 142(630) 52(231) 79 (349) 0.555 Castillo Engineering OPs10NE0 TO •uMm CASTILLO ENGINEERING SERVICES, LLC COAN.Us 2925 W. STATE ROAD 434, SURE 111 LONGWOOD. FL 32779 i '(dO VM-2515 EFMOCRATESEGSTLLO-FL PE Si550 REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER SUNPRW \\\\ Igozlu � <JJJr �E.,... N • O . 0 590 T T O r r ❑ op Z (7 W J LU u) LL Q' Z U LU C C5J W of W_ E- LL _ 2 U (DLL o Of NO 0 6 2913 SHEETNAME RAIL DATA SHEET SHEET SIZE ANSI B 11" X 17" SHEET NUMBER DS-03 II Ci The 5-5-N and 5-5-N Mini clamps are each supplied with the hardware shown to the right. Each box also includes a bit tip for tightening setscrews using an electric screw gun. The 5-5-N Is a structural aluminum attachment clamp, compatible with most common metal roofing materials (excluding copper). All included hardware is 300 series stainless steel. Please visit www.5-5.com for more information including CAD details, metallurgical compatibilities, and specifications. 5-51w holding strength is unmatched in the Industry. Fits Panels Up to .82" Nail Relief (NOTE: Seams Nat exceed maximumallowanceat the widest seam will require hand crimping to allow the clamp to fit). Ease of Installation ... in I...2...3 Installation simplified: The 5-5-N is still just as quicksand easy to install as other 5-5 clamps. But now, we've angled the setscrews toward the Installer, allowing easier access with a screw gun, simplifying tool removal once the setscrew has been tightened - ensuring the clamp sits straighter on the seam. Choose the 5-5-N for a non -penetrating solution that protects the roof while providing excellent holding strength. 9 a5 S-5-N Uarnp S-5-N Mini Cr arap F S-51e Wamingl Please use this product respens(blyl Distributed by ProduN are protected by multiple LLS and loreign Parents, visit Me wers eat wM&Sarm for mraiders information apnannendmdemor"Fru—A.m.fool rgmmgm,eeunaw soculd hetew0.ed and reaenrbnedor uereammu."Ma,ne .cramp reurrewtewen Mnuidbe wrlfrtd wing Oalmod torque wench between 160and 1.01nd, poundrarc en read an 229e steel, and bananas 130and 1504M pounds (of anethermatalsaodWarner gauge 9 of Mel. cement us Sil —cars tl—nas S.romfar published gun, MaNing total r,ubenglR lugrgaIDl4fMallbaM1•uudb¢Y155podnsmpmmpmnrtd 59 ape WeIYp,Ieaz M W 1m6baMwba W m(Mglr4vnsNr 0tfb1A SSAoAtl.51ee1.65NJlEw2D Wbtld 2 7 (. Castillo � Engineering DESIONED To Pe EMII- CASTILLO ENGINEERING SERVICES, LLC co" n"s 2925 W. STATE ROAD 434. SURE 111 LONGWCOD, FL 32TT9 TEL IaOTI5 ERMOCRITE$ E GSTlu_OTILLO - F L PE 5E55D REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER SUNPR�-- E\GENsF p ya No 52590 lJJ STATE OF Q N A�E�. "T?011111ottt U Z W 0 °D Z CO W .J W cq LL Z^^ LL V [if W O a LL = vn- U �o O LL EU 0 6 2913 SHEET NAME ATTACHMENT DATA SHEET SHEET SIZE ANSI B Sane 39TpM 1111 X 17" SHEET NUMBER DS-04