Loading...
HomeMy WebLinkAboutCertification for Design Load CompliancePlanning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982—(772) 462-1553 Certification for Design Load Compliance Project Name: Rigdon Garage Conversion Project Address: 10151 S. Indian River Drive, Fort Pierce, FL 34982 Permit tl:2001-0150 Occupancy Type: Residential Construction INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the N above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Exist. Bldg. Code Sixth Edition with 20 17 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category:_I X II _III _IV Exposure Category:_BC X D 4. Design Wind Velocity 170 mph ASDLRFD End Zone Width: 3•3' ft 5. Mean Roof Height 10'-6" ft Roof Pitch: 4 :12 Parapet: ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: +26.4.42.0 Zone 2: +26.4, -73.1 Zone 3: +26.4, -73.1 Zone 4: +45.9, -49.6 Zone 5: +45.9, -61.4 Garage: +38.7, -47.0 7. Design Loads: Floor: N/A PSF Roof/Dead: N/A PSF Roof/Live: N/A Balcony: PSF Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF 8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X YesNot Applicable Explain Why Not: 10. Design Soil Bearing Pressure: N/A PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: Signature, Date, and Seal Revised 12/07/2018 Don Bergman Print Name Cert H & Co. Cert Auth. Don Bergman Architecture LLC 4362 Gator Trace Lane, Fort Pierce, FL 34982 P_v Company Name & Address pp _