HomeMy WebLinkAboutCertification for Design Load CompliancePlanning & Development Services Department
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982—(772) 462-1553
Certification for Design Load Compliance
Project Name: Rigdon Garage Conversion
Project Address: 10151 S. Indian River Drive, Fort Pierce, FL 34982
Permit tl:2001-0150 Occupancy Type: Residential Construction
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the N above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida Exist. Bldg. Code Sixth Edition with 20 17 Supplements using ASCE 7-10
2. Structure Designed as (check one):
X Enclosed _Partially Enclosed _Open
3. Risk Category:_I X II _III
_IV Exposure Category:_BC
X D
4. Design Wind Velocity 170
mph ASDLRFD End Zone Width: 3•3'
ft
5. Mean Roof Height 10'-6"
ft Roof Pitch: 4 :12 Parapet:
ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: +26.4.42.0 Zone 2: +26.4, -73.1 Zone 3: +26.4, -73.1 Zone 4: +45.9, -49.6 Zone 5: +45.9, -61.4 Garage: +38.7, -47.0
7. Design Loads: Floor: N/A PSF Roof/Dead: N/A PSF Roof/Live: N/A Balcony: PSF
Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF
8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X YesNot Applicable Explain Why Not:
10. Design Soil Bearing Pressure: N/A PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified:
Signature, Date, and Seal
Revised 12/07/2018
Don Bergman
Print Name Cert H & Co. Cert Auth.
Don Bergman Architecture LLC
4362 Gator Trace Lane, Fort Pierce, FL 34982 P_v
Company Name & Address pp _