Loading...
HomeMy WebLinkAboutEnergy Code., FORM R405-2017 K` FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION J Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: RIGOON RESIDENCE Builder Name: Street: 10151 S. INDIAN RIVER DRIVE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Owner. Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or e)dsting New (From Plans) 9. Wall Types(1504.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Polystyrene Bead Aggret=0.0 1168.00 IF b. Frame - Wood, Adjacent R=11.0 336.00 IF 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 10. Ceiling Types (1573.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=30.0 1573.00 If 6. Conditioned Floor area above grade (W) 1573 b. N/A R= ft' Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ff 7. Windows(211.8 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Garage 6 140 a. U-Factor: Sgl, U=0.31 174.00 ft2 SHGC: SHGC=0.18 b. U-Factor. Sgi, U=0.32 37.78 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.16 a. Central Unit 29.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 27.0 COPA.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.176 14. Hot water systems 8. Floor Types (1573.0 sqft.) Insulation Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 1573.00 W b. Conservation features EF: 0,980 b. N/A R= I? None c. N/A R= ft, 15. Credits None Total Proposed Modified Loads: 49.69 Glass/Floor Area: 0.135 PASS Total Baseline Loads: 51.39 I hereby certify that the plans and specifications covered by Review of the plans and TSE STAT this calculation are in compliance with the Florida Energy specifications covered by this o Code. calculation indicates compliance oq) '% T ' with the Florida Energy Code. t; r„r,,,P•.: ra•'�s;,,, �O� PREPARED BY: DATE: 3-13-20.0 Before construction is completed this building will be inspected for compliance with Section 553.908 e •! I herebycerti th 's uildi fy y,'as designed, is in compliance Florida Statutes. .(. OOp with the Florida nerg e. WE OWNE T. BUILDING OFFICIAL: DATE: DATE: - - Compliance require certil<cation bylhe air handler unit manufacturer that the air handler enclosure qualifies as certified factory-se21 d in accordance with R403.3.2.1. - Compliance requires n�Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test reportrwtth envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). JI.F, 3/12/2020 12:07 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant SotWfrePage 1 of 7 • FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Titre: RIGDON RESIDENCE Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1573 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 10151 S. INDIAN RIVE Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1573 12584 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Coded Heated 1 BEDROOM 156 1248 No 0 1 1 Yes Yes Yes 2 CLST 18 144 No 0 1 Yes Yes Yes 3 BATH 72 576 No 0 1 Yes Yes Yes 4 LAUNDRY 54 432 No 0 1 Yes Yes Yes 5 OFFICE 130 1040 No 0 1 Yes Yes Yes 6 OFFICE CLST 12 96 No 0 1 No Yes Yes 7 HALLWAY 76 608 No 0 1 No Yes Yes 8 KITCHEN 216 1728 Yes 0 1 Yes Yes Yes 9 LIVING/DINING 432 3456 No 0 1 Yes Yes Yes 10 M HALL 16 128 No 0 1 No Yes Yes 11 MASTER BEDROO 221 1768 No 0 1 1 Yes Yes Yes 12 M WIC 70 560 No 0 1 Yes Yes Yes 13 M BATH 100 800 No 0 1 Yes • Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpel 1 Slab -On -Grade Edge Insulation BEDROOM 25 ft 0 156 ft- ---- 1 0 0 2 Slab -On -Grade Edge Insulation CLST 2 ft 0 18 fl' ---- 1 0 0 3 Slab -On -Grade Edge Insulation BATH Sit 0 72 (t' 1 0 0 4 Slab -On -Grade Edge Insulation LAUNDRY 6 ft 0 54 ft' _-__ 1 0 0 3112/2020 12:07 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT 4 1 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 5 Slab -On -Grade Edge Insulation OFFICE 10ft 0 130 It' ____ 1 0 0 6 Slab -Orr -Grade Edge Insulation OFFICE CLST 1 It 0 12 ft' 1 0 0 7SIab-On-Grade Edge Insulation HALLWAY 1 It 0 76 fF ____ 1 0 0 8 Slab -On -Grade Edge Insulation KITCHEN 12 it 0 216 ft' ___ 1 0 0 9 Slab -On -Grade Edge Insulation LIVING/DINING 43 ft 0 432 fN ____ 1 0 0 10SIab-On-Grade Edge Insulation M HALL 1 it 0 16 ft' ____ 1 0 0 11SIab-On-Grade Edge Insulation MASTER BEDRO 13 It 0 221 it- _-__ 1 0 0 12SIab-On-Grade Edge Insulation M W IC 7 It 0 70 It' ___ 1 0 0 13SIab-On-Grade Edge Insulation M BATH 20 ft 0 100 ft' ____ 1 0 0 ROOF Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1759 fP 0 ft' Medium N 0.6 No 0.9 No 30 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area FIBS IRCC 1 Full attic Unvented 0 1573 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type _ 1 Under Attic(Unvented) BEDROOM 0 Blown 156 It' 0.1 Wood _ 2 Under Attic(Unvented) CLST 0 Blown 18 ft. 0.1 Wood _ 3 Under Attic(Unvented) BATH 0 Blown 72 fN 0.1 Wood _ 4 Under Attic(Unvented) LAUNDRY 0 Blown 54 ft' 0.1 Wood _ 5 Under Attic(Unvented) OFFICE 0 Blown 130 11' 0.1 Wood _ 6 Under Attic(Unvenled) OFFICE CLST 0 Blown 12 ft' 0.1 Wood _ 7 Under Attic(Unvented) HALLWAY 0 Blown 76 It' 0.1 Wood _ 8 Under Attic(Unvented) KITCHEN 0 Blown 216It- 0.1 Wood 9 Under Attic(Unvented) LIVING/DINING 0 Blown 432 ft' 0.1 Wood 10 Under Attic (Unvented) M HALL 0 Blown 16 ft' 0.1 Wood _ 11 Under Attic(Unvented) MASTER BEDRO 0 Blown 221 IF 0.1 Wood _ 12 Under Attic(Unvented) MWIC 0 Blown 70 it- 0.1 Wood 13 Under Attic (Unvented) M BATH 0 Blown 100 Ill 0.1 Wood 3112/2020 12:07 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Belau _ 1 SE Exterior Concrete Block - Polystyr&WROOM 0 13 0 8 0 104.01? 0 0 0.6 0 _ 2 SW Exterior Concrete Block - PolystyrBMROOM 0 12 0 8 0 96.0 IF 0 0 0.6 0 _ 3 NE Garage Frame -Wood BEDROOM 11 12 0 8 0 96.0 ft2 0 0.1 0.6 0 _ 4 SW Exterior Concrete Block - PolystyreneCLST 0 2 0 8 0 16.0 ft2 0 0 0.6 0 _ 5 SW Exterior Concrete Block- Polystyrend3ATH 0 8 0 8 0 64.0 ft- 0 0 0.6 0 _6 SW Exterior Concrete Block- Polystyrdo@UNDRY 0 6 0 8 0 48.0 ft2 0 0 0.6 0 _ 7 SW Exterior Concrete Block - Polystyrer@FFICE 0 10 0 8 0 80.0 ft' 0 0 0.6 0 _ 8 NE Garage Frame - Woad HALLWAY 11 10 0 8 0 80.0 ft2 0 0.1 0.6 0 _ 9 SE Garage Frame- Wood HALLWAY 11 2 0 8 0 16.0 ft2 0 0.1 0.6 0 _ 10 NE Exterior Concrete Block- PolystyreK@TCHEN 0 12 0 8 0 96.0 W 0 0 0.6 0 _ 11 SE Garage Frame- Wood KITCHEN 11 18 0 8 0 144.0 ft2 0 0.1 0.6 0 12 NE Exterior Concrete Block- PolyslytIVING1DININ 0 27 0 8 0 216.0 112 0 0 0.6 0 13 NW Exterior Concrete Black- PolystytWtNG/DININ 0 16 0 8 0 128.0W 0 0 0.6 0 _ 14 SW Exterior Concrete Block - PolysqmMASTER BE 0 13 0 8 0 104.0 ft2 0 0 0.6 0 15 NW Exterior Concrete Block - PolystyrentA W IC 0 7 0 8 0 56.0 ft2 0 0 0.6 0 _ 16 SW Exterior Concrete Block - PolystyrerM BATH 0 10 0 8 0 80.0 W 0 0 0.6 0 17 NW Exterior Concrete Block - Polystyrerld BATH 0 10 0 8 0 80.0 ft2 0 0 0.6 0 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening _ 1 SW 2 Vinyl Low-E Single Yes 0.31 0.18 N 30.0 ft2 2 It 0 in 0 it 5 in None None _ 2 SW 5 Viny1 Low-E Single Yes 0.31 0.18 N 6.0 ft2 2 It 0In 0 It 5 in None None _ 3 SW 6 Vinyl Low-E Single Yes 0.32 0.16 N 17.8 ft2 2 It 0 in 0 It 5 in None None 4 SW 7 Vinyl Low-E Single Yes 0.31 0.18 N 15.0 ft2 2 It 0 in 0 If 5 in None None 5 NE 10 Vinyl Low-E Single Yes 0.31 0.18 N 24.0 ft2 2 ft 0 in 0 it 5 in None None _ 6 NE 12 Vinyl Low-E Single Yes 0.31 0.18 N 30.0 ft2 2 it 0 in 0 it 5 in None None _ 7 NE 12 Vinyl Low-E Single Yes 0.32 0.16 N 20.0 ft2 2 ft 0 in 0 it 5 in None None _ 8 NW 13 Vinyl Low-E Single Yes 0.31 0.18 N 30.0 ft- 2 It 0In 0 ft 5 in None None _ 9 SW 14 Vinyl Low-E Single Yes 0.31 0.18 N 30.0 ft2 2 it 0 in 0 ft 5 in None None 10 NW 17 Vinyl Low-E Single Yes 0.31 0.18 N 9.0 1t2 2 it 0 in 0 it 5 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 440 ft2 440 112 42 it 8 ft 11 3112/2020 12:07 PM EnergyGauge@J USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1468.1 80.6 151.58 .1233 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 27 kBtuthr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 16 29 kBtulhr 870 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None f? DUCTS / --- Supply--- V # Location R-Value Area --- Return -- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT ON RLF HVAC # Heat Cool 1 Attic 6 140 fP Attic 14 fF Default Leakage Garage (Default) c(Default) c 1 1 TEMPERATURES Programable Thermostat: N rr ling Jan Feb Mar Venting Jan Feb [ Mar Apr Crreiling Fans: May JunrJul Aug Sep Octr Apr [ May Jun [ Jul Aug Sep Oct rr Nov [ Nov Dec Dec 3/12/2020 12:07 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7 • FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 a • Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating(WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 11,111*1 Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft, 0 ft 0.3 GREAT ROOM Default(B lbs/sq.ft. ft2 ft 0.3 FOYER Default(8 lbs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft2 ft 0.3 DINING Default(81bs/sq.ft. ft2 ft 0.3 PANTRY Default(B lbs/sq.ft. ft2 ft 0.3 ARRIVAL Default(B lbs/sq.ft. ft2 ft 0.3 GARAGE HALL Default(B lbs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(B Ibs/sq.ft. ft2 ft 0.3 HALL 2 Defaull(81bs/sq.ft. ft2 ft 0.3 WIC4 Default(8 Ibs/sq.R. ft2 ft 0.3 BATH 4 Default(8 lbs/sq.ft. ft2 ft 0.3 STAIR HALL Default(B Ibs/sq.ft. ft2 ft 0.3 UTILITY Default(8 li ft2 ft 0.3 BEDROOM Default(8 lbs/sq.ft. ft2 ft 0.3 :BATH 2 Default(8 lbs/sq.ft. ft2 ft 0.3 WIC Default(8 lbs/sq.ft. ft2 ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 3 Default(8 lbs/sq.ft. ft2 ft 0.3 POWDER RM Default(B lbslsq.ft. IF R 0.3 BONUS RM Default(8 lbs/sq.ft. ft2 ft 0.3 HALL 3 Default(81bs/sq.ft. ft2 ft 0.3 WET BAR Default(8 lbs/sq.ft. ft2 ft 0.3 STAIRS UP Default(8 lbs/sq.R. W ft 0.3 GYM Default(B lbs/sq.ft. ft2 ft 0.3 MEDIA Default(B Ibs/sq.ft. ft2 ft 0.3 M W IC 2 Default(B lbs/sq.ft. ft2 ft 0.3 M W IC 1 Default(8 lbs/sq.ft. ft2 ft 0.3 MTOILET 1 Default(8 lbs/sq.ft. ft2 ft 0.3 M TOILET 2 Default(8 lbs/sq.ft. ft2 ft 0.3 M BATH Default(8 lbs/sq.ft. IF ft 0.3 DEN Default(B Ibs/sq.ft. ft2 ft 0.3 MASTER SUITE Default(8 lbs/sq.ft, fP ft 0.3 M HALL Default(8 lbs/sq.ft. ft2 ft 0.3 POOL BATH 311212020 12:07 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7 • FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(B Ibs/sq.fl. ft2 ft 0.3 CASITA BAR Default(S Ibs/sq.ft. ft2 ft 0.3 CASITA W IC Default(B Ibs/sq.ft. ft2 ft 0.3 CASITA BATH Default 8lbs/s .ft. ft, ft 0.3 CASITA 3/12/2020 12:07 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 3. No. of units (ifmultiple-family)3. 1 c) AHU location Garage 4. Number of bedrooms 4. 2 5. Is this a worst case? (yes/no) 5. No 6. Conditioned floor area (sq. ft.) 6. 1573 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.312 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.176 c) Area 7c. 211.8 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. c) Concrete, raised (R-value) 9c. 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and Insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 10A1. 10A2. 0.0 13. Cooling system: Capacity 29.0 a) Split system SEER 16.0 b) Single package SEER c) Ground/water source SEER/COP d) Room unit/PTAC EER e) Other 14. Heating system: Capacity 27.0 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP 1.0 d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE 0 Other 15. Water heating system a) Electric resistance EF 0.98 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF_ f) Heat recovery unit HeatRec% g) Other 10131. 11.0 10B2. 16. HVAC credits claimed (Performance Method) a) Ceiling fans 11a. 0.0 b) Cross ventilation No 11b. c) Whole house fan No 11c. d) Multizone cooling credit 11d. No e) Multizone heating credit f) Programmable thermostat No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Address of New Home: 10151 S. INDIAN RIVER DRIVE City/FL Zip: 3/12/2020 12:08:47 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software «W of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Garage 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 29.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEERICOP 6. Conditioned floor area (sq. ft.) 6. 1573 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.312 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.176 14. Heating system: Capacity 27.0 c) Area 7c. 211.8 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 81b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.98 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 0.0 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 1082. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 0.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit 0 Programmable thermostat No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Address of New Home: 10151 S. INDIAN RIVER DRIVE City/FL Zip: FORT PIERCE FL 3/12/2020 12:08:47 PM EnergyGaugeO USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Softwaree 1 Of 1