Loading...
HomeMy WebLinkAboutPermit Worksheets6 F PERMIT NUMBER Installer ►'llpMW _ L,(B1 lal n uDense# �N - W) 3-7 Address of home 621 �rJ being Installed l ' 1'i"(N� - oiri Manufacturer NOTE '!f home !s a Length xwidth nale one half of the blocking plan !f home Is a triple or quad wide sketch in remainder of home I understand Lateral Arts Systems Cannot be used on any home (new or used) where the sidewall ties exceed 5 it 4 in. Installer's initials Typical pier spacing E—,I I Show locations of Longitudinal and Lateral Systems latpltu9nd . (use dark lines to show these locations) ' Maf-i- W1M pl,m WHWn 7 d end.1 hems PERMIT JAN 10 2019 rn/ST ucie County r� a New Home. 47 de LJ Home Installed to the Manufacturers Installation 4W Hoome Is installed In aocordance with Rule 16.0 Single wide ❑ Wind Zone II ❑ V) Double wide ' Installation Decal # Tdple(Quad ❑ Serial # r. LL PIER SPACING TABLE FOR USED IIOM O [A of Laed Footr bearing lza size 16'X16' 181/2'Xt81/2' 20'x20' .22'x22' 24'X24' 26'x26' capacity (sq in) 1") (e42) (40D) (464)' (576)' (676) 1000 5 3 00 s 4 6 6 B oDD 6 g g 2 00 s 6 g g B 3000 s g 3 0 g PIER PAD SIZES I�'�7 ��� POP AR PAD 61 ES I-beam plat pad size Lam) Perimeter pier pad size ) 2 21 Other pier pad sizes 1 Zt�i (required by the mfR.) ®Draw the approximate locations of marriage wall openings 4 toot or greater. Use this symbol to show the piers. List all marriage wall openings greater than 4 foot and their le d I b iikEiB���1y itrsz•1•a��V iKiICS'LI:�IC� �d'sz.7.>o� . � � 2 i►L<ii[:3:Y.r.'icifl:t i►flfsrY4ar% .ter. ����" p r pa s zes elow. ANCHORS rr Opening ` Pierpad:slze 4 it L"" •5 it 2 ZL � FRAMETIEB within 2' of end of home. spaced at 5' 4n Do V TIEDOWN COMPONENTS OTHER ES Longhudlnal $tabJ/izM Device LS Sidewalt Number Manufacturer ia7 L;j Longitudinal Longitudinal StabllWng Device WL era/ArmsJ Marrlags wail Manufacturer. Sh mrwa)I PERMIT NUMBER� PERMIT WORKSHEE7 page 2 of 2 a; a' t".1 POCKET PENETROMETER TES The pbcket penetrometer tests are rou d owrite— psf or check hereto declare 1000 lb. soil without testing. X—_ X__ X_ POCKET PENETROMETER TESTING METHOD 1. Test the perimeter of the home at 6 locations. 2. Take the reading at the depth of the.footer. S. Using goo lb. increments, take the lowest reading and round down to that IncramenL TORO E PROBE TEST The results of the torque probe test is • Inch pounds or check here If you are declaring 5' anchors without test ng _ - A test . showing 275 Inch pounds or less will require 5 foot anchors. Note: A state approved lateral arm system Is being used and 4 It anchors are allowed et4he sidewall locations. 1 understand 5 It anchors are required at all centerline He points where the torque test reading Is 27Tr or less and ere the rrlobile home manufacturer may requires anchors with 4D bb I a`pacity. Installer's Initials ALL TEST S'fv1 T BE PERF RMEDBY A LICENSED I1:ISTALLER Installer Name Date Tested ' FJeetrleal Ionneot electrical conductors between multi•wide units, but not to the a ower ouroe. This•Includes the bonding wire between mult•wide units. Pg. onnect all sewer drains to an existing sewer tap or s plc tank Pg. onnect all potable water supply piping to an ng water meter, water tap, or other rdepandent water supply syslems, 'Pg. Debris and organic material Water drainage: Natural _ Floor. Walls: Roof: WIII be centered over roofing nails at 2° on an both sides of the Other _ _ Gasket Iweelhenroofi rwul p I understand a property installed gasket Is a requirement of all new and used homes and that condensation, mold, meldew and buckled marriage walls are a result of a poorly installed or no gasket being Instal*1understand a strip of tape will not serve as a gasket. Installer's initials Type gasket Installed: Pg. Between Floors Yes Between Walls Yes Bottom of ridgebeam Yes Weatherproonnc The bottomboard will be repaired and/or taped. Yes Pg.- Siding on units is installed to manufacturer's specifications. Yes Fireplace chimney Installed so as not to allow intrusion of rain water. Yes Skirting to be Installed. Yes _��No_ Dryer vent installed outside of skirting. Yes WA�� Range downflow vent installed outside of skkkjjjrtrtrtin as WA Drain lines supported at 4 foot Interval Electrical crossovers protected. Yes �L_ Other: is accurate and true based on the Installer Signature Dete&% —2951