Loading...
HomeMy WebLinkAboutConstruction Planse 2 -53" 2'-6" WINDOW SWINGING 1. THESE PLANS PERTAIN ONLY TO THE STRUCTURE, INCLUDING MAIN WIND FORCE RESISTING SYSTEM, COMPONENTS AND CLADDING, AND BASE RAIL ANCHORAGE. OTHER DESIGN ISSUES, INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET —BACKS, FINISH FLOOR ELEVATION AND SLOPE, OR OTHER LOCAL ZONING REQUIREMENTS ARE THE RESPONSIBILITY OF OTHERS. 2. THIS STRUCTURE IS DESIGNED AS A NON —HABITABLE UTILITY/STORAGE BUILDING (RISK CATEGORY 1) CAPABLE OF SUPPORTING DEAD LOAD OF THE STRUCTURE AND APPLICABLE LIVE AND WIND LOADS. IMPROVEMENTS NOT SPECIFICALLY ADDRESSED HEREIN, INCLUDING DOORS, WINDOWS, OR OTHER COMPONENTS NOT LISTED IN THE FBC APPROVED PRODUCTS LIST, AND NOT PROVIDED AND INSTALLED BY CARPORTS ANYWHERE, INC., WHICH EXERT ADDITIONAL LOADS ON THE STRUCTURE SHALL BE AT THE OWNER'S RISK. CARPORTS ANYWHERE NOR THE ENGINEERING DESIGN SHALL NOT BE RESPONSIBLE FOR STRUCTURAL DAMAGE OR FAILURE DUE TO THE APPLICATION OF ADDITIONAL LOADS. 3. THIS BUILDING IS EXEMPT FROM THE FBC ENERGY CONSERVATION CODE PER SECTION C101.4.2. 4. ALL STEEL TUBING SHALL BE 50 KSI STEEL AND MEETS/EXCEEDS GALVANIZATION PER ASTM A1003/A1003M-15. 6. PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET —BACKS, AND/OR OTHER LOCAL CODE REQUIREMENTS ARE THE RESPONSIBILITY OF THE OWNER. 6. ROOF AND WALL SHEATHING SECURED WITH #12-14x1" SELF —DRILLING SCREWS WITH SEAL WASHERS ® 6" O.C. MAX. 7. FIELD FRAMING CONNECTIONS SECURED WITH #12-143/4" SELF —DRILLING SCREWS. 8. ALL SHOP FRAMING CONNECTIONS ARE TO BE WELDED. NO WELDING ONSITE. ALL WELDING DONE IN SHOP. 9. CONCRETE EXPANSIONS ANCHORS ARE TO BE MINIMUM 1/2" DIAMETER & 2,500LB TENSILE STRENGTH. 10. 12 OR 14GA. FRAMING IS 2.5"x2.5" TUBE STEEL. NIPPLES ARE 2.25"x2.25" TUBE STEEL. AND COVERED WITH 6 MIL VAPOR RETARDANT PER SECTION 2017 FLORIDA BUILDING CODE, 6TH EDITION —MINIMUM 2.500 PSI COMPRESSIVE STRENGTH AT 28 DAYS —ALL OPEN AREAS OF CONCRETE OUTSIDE OF THE PROPOSED STRUCTURE SHALL BE DESIGNED TO SLOPE AWAY FROM THE STRUCTURE REINFORCING STEEL (REBA REQUIREMENTS: —MINIMUM GRADE 40 STEEL —REBAR MAY BE BENT IN SHOP OR FIELD PROVIDED: —THE REBAR IS BENT COLD —THE DIAMETER OF THE BEND MEASURED ON THE INSIDE DOES NOT EXCEED 6—BAR DIAMETERS: AND —REINFORCEMENT PARTIALLY EMBEDDED IN CONCRETE SHALL NOT BE FIELD BENT EXCEPT IN CASES WHERE DOWELS NEED TO BE BENT TO ALIGN WITH A VERTICAL CELL THESE REBAR MAY BE BENT NOT TO EXCEED TO SLOPE OF 1' HORIZONTALLY TO 6" VERTICALLY. —COVER; —2" COVER MINIMUM WHERE THE CONCRETE IS CAST AGAINST AND PERMANENTLY IN CONTACT WITH SOIL OR WEATHER, AND 1}" ELSEWHERE. REBAR EMBEDDED IN GROUTED CELLS SHALL HAVE A MINIMUM CLEAR DISTANCE OF }' FOR FINE GROUT, AND I" FOR COARSE GROUT BETWEEN REBAR AND ANY FACE OF A CELL REBAR USED IN MASONRY WALLS SHALL HAVE A MASONRY COVER (INCLUDING GROUT) OF NOT LESS THAN 2" FOR MASONRY UNITS WITH FACE EXPOSEDTO EARTH OR WEATHER. AND 17j" FOR MASONRY UNITS NOT EXPOSED TO EARTH OR WEATHER. GALVANIZATION- -METAL ACCESSORIES FOR USE IN EXTERIOR WALL CONSTRUCTION AND NOT DIRECTLY EXPOSED TO WEATHER SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM A 153. CLASS B-2. METAL PLATE CONNECTORS, SCREWS, BOLTS, AND NAILS EXPOSED DIRECTLY TO WEATHER SHALL BE STAINLESS STEEL OR HO7 DIPPED GALVANIZED. I in MIN. 2,500 MESH) --------------------------------------------------- 20'-0" 0' -12F J"x54" EXPANSION ANCHOR WITHIN 6" OF EACH POST/TRUSS ALONG SIDES AND EVERY OTHER END —WALL POST 2" MIN. BASE RAIL GRAD /�I 1=I= _ <a 2,500 PSI 4° CONCRETE SLAB WITH 12" W.W.F. OR FIBER MESH I— (2) #5 REBAR ® 6" O.C. MINIMUM SOIL BEARING CONTINUOUS WITH MINIMUM CAPACITY 2,000 PSF(TYP.) 12" OVERLAP SPLICE CONCRETE FOUNDATION/BASE RAIL ANCHOR DETAIL 2.5" PLAN VIEW DOOR FRAMING " RECESS I r ° DOOR WIDTH - ELEVATION VIEW DOOR FRAMING RECESS .5"T DOOR WIDTH- 7 OPTIONAL ROLL -UP DOOR CONCRETE SPLASH -GUARD RECESS PSI 4" CONCRETE SLAB WITH W.W.F. (OR FIBER AND 125)x12" REINFORCED FOOTER PERIMETER c"Ooa D CAMIMANMME _ Ro N ASCE-7-10 MANUFACTURER CARPORTS ANYWHE BUILDING TYPE UTILITY STRUCTURE CONSTRUCTION TYPE II-B RISK CATEGORY FIRE PROTECTION NONE FIRE SUPPRESSION SYSTEM NONE OCCUPANCY UTILITY, U .0 OPSF DEAD LOAD LIVE LOAD PER O i ow, er: MTB ROLL-; UP o DATE- 12/11/19 D O O,R LarwnaN: � 110 Beach Ave., Port St. Lucie 20'1 X 15W X 9'H 12"x12" REINFORCED FOOTER CODE ST. LI E Ok1NV CD! 1%f�� Ld 12/14/19 Z Matthew T. Baldwin P.E. Florida License #64608 �y g ,1 p 0_ Sheet 4 CA-1 O F 12 3� ROLL —UP DOOR —61t 15'-0" 15 —0" FRONT END WALL REAR END WALL 20'-0" LEFT SIDE WALL 1 WINDOW D.C. ENCLOSURE ENCLOSED INTERNAL PRESSURE COEFF. + — 0.18 IMPORTANCE FACTOR 1.0 ROOF DEAD LOAD 10PSF ROOF UVE LOAD 20PSF OR 3001b P.L FLOOR DEAD LOAD 10PSF FLOOR LIVE LOAD 5OPSF Wu 12/11/19 La =N: 110 Beach Ave., Port St. Lucie 20-L % 15-W % 9'H tEllIEWED FOR DE COMPLIANCE L CIE COUNTY s®CG SWINGING 1' —113. W DOOR 5 i 3'-0" � nnn QW'/ V Ill 20'-0' Z RIGHT SIDE WALL w 12/14/19 46 MottheW T. BaldWin P.E. LLJ Florida License #64608 l Sheet: CA-2 OF 4 MINIMUM 6' TS NIPPLE. NIPPLE SECURED TO WALL POST WITH SCREWS 14xj" SELF-DRIWNG POST TO BASE RAIL CONNECTION MINIMUM 6" TS NIPPLE. NIPPLE SECURED TO WALL POST WITH SCREWS 14x3" SELF—DRIWNG 2'x2'x2" 16 GA ANGLE CUP SECURED WITH (4) #12-14x1" SELF—DRIWNG SCREWS 2'x2'x2' 16 GA ANGLE CLIP SECURED WITH (4) #12-14q A. ANGLE CUP SELF—DRIWNG SCREWS " WS SCREWS SINGLE OR DOUBLE TS HEADER INTERMEDIATE POST TO END POST TO BASE RAIL HEADER/BASE RAIL/OR HEADER CONNECTION CONNECTION WINDOW RAIL DETAIL DETAIL OPTION 1 2"x2"x2" 16 GA. ANGLE CUP SECURED WITH (4) #12-14x4" SELF —DRILLING 2'x2"x2" 16 GA ANGLE CUP SECURED WITH (4) #12-14)4' SELF —DRILLING SCREWS NON-STRUCTURAL HEADER OR WINDOW RAIL TO POST DETAIL � 3" MAX.;" SELF—DRIWNG SCREWS ® 10" O.C. MAX., 3" MAX. FROM CORNERS HORIZONTALLY/ 4' MAX. r FROM CORNERS VERTICALL` INTERIOR n a1 : •. DOOR FRAME TO POST CONNECTION MAX. MAX. MIN. SIDE WALL ROLL —UP DOOR/FRAME OUT HEADER DETAIL INSTALL PER MANUFACTURERS INSTRUCTIONS #140" SELF—DRILUNG SCREWS ® 6" O.C. MAX. & 6' MAX. FROM CORNERS ROLL -UP DOOR TO POST CONNECTION DESIGN PRESSURES - 150 Mph ROOF +19.3/-41.4 WALLS +20.0/-22.2 DOORS +20.0/-22.2 WINDOWS +20.0/-22.2 1 2 3 4 5 ZONE +9.3 -21.9 +12.3 -35.1 +19.3 -41.4 +18.8 -21.9 +20.0 -22.2 26 GAUGE ROOF SHEATHING SECURED WITH' (1)k12-14xj" SELF—DRIWNG SCREWS 6)_ 2-1-2-1' (6" O.C. (9" O.C. MAX.)) 1" 16 GAUGE FURRING CHANNEL 48" O.C. MAX. SECURED WITH (2)#12-14x1" SELF—DRIWNG SCREWS TO EACH RAFTER. ROOF PANEL CONNECTION VERTICAL SHEATHING OPTION TO 16 GA. U—CHANNEL BRACE, MIN. 24" UP T( 7' POST, MIN. 48" OVE 7' POST. MIN. 45' TO MAX. 69 FROM HORIZ. (EXCLUDE END —WALLS) MINIMUM 6" TS NIPPLE. NIPPLE SECURED TO WALL POST WITH SC)EEWS 14x1" SELF —DRILLING BOX EAVE RAFTER TO POST CONNECTION DETAIL Ole SCAgaMINIMUM 6" Ts NIPPLE. NIPPLE ' SECURED TO WALL POST WfCA VMANI . , FRF )REW514xJ' SELF—DRIWNG fl ♦�vy OR DOUBLE TS HEADER CONNECTION DETAIL OPTION 2 TO MINIMUM 6' TS NIPPLE. NIPPLE SECURED TO WALL POST WITH (4)512-14)4" SELF—DRIWNG SCREWS POST TO TRUSS CONNECTION REVIEWED FOR CODE COMPLIANO ST. LUCIE COUNT socc APPROVED PRODUCTS APPROVAL NO. ROOF SHEATHING Carports Anywhere FL27402.1—R1 Hampton Rib Roof Panel WALL SHEATHING Carports Anywhere FL27403.1 Hampton Rib Wall Panel SWINGING DOOR ELIXER DOOR AND METAL COMPANY FL17996.5 407 STEEL DOOR ROLL —UP DOOR JANUS INTERNATIONAL CORPORATION FL12765.3—R5 SERIES 3100 WINDOW POCOHONTAS ALUMINUM COMPANY, INC. FL12940—R5 MODEL 100VS CODE FLOOR DEAD LOAD IIOPSF FLOOR LIVE LOAD 50PSF 'R"RATING OF WALLS,FLOOR,ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE NO V) J Q W 0 MTB 110 Beach Ave" Port St. Lucie ' 20'L X 15'W X 9H 12/14/19 Matthew T. Baldwin P.E. Sheet- CA-4 OF 4 MOD DJJ4 FILE COPY