Loading...
HomeMy WebLinkAboutSoil TreatmentPlanning & Development Services Building & Code Regulation Division 2300 Virginia Ave Fort Pierce, FL 34952 772-462-2172 Fax 772-462-6443 RECEIVED FEB 2 7 2020 ST. Lucie County, Permitting CERTIFICATE OF TERMITE TREATMENT CONSTRUCTION SOIL TREATMENT 'PERMIT #: I G - C)5 a JOB AD BUILDER/CONTRACTOR: PEST CONTROL CONTRACTOR:�� PEST CONTROL LICENSE #: 7 \ : 9 ) b SfVA61- "L h We, the undersigned, hereby certify that we have pretreated the above described construction for subterranean termites in accordance with the standards of the National Pest Control Association. Square feet if area treated:360 Percentage of solution: Date of Treatment: ea -I 1 2 Fdoting 1'�t Treatment Re -Treat Driveway 1" Treatment Re -Treat Other 11� Treatment Re -Treat Chemicals used: rhho54 e.c Total gallons used: Time ofTreatment: % Z-) S� Sty lab p 1't Treatment Re -Treat Pools 1�` Treatment R Treat Pert for F' nspection Z� Sign re of Exterminator D to Note. There must be a completed form for each required treatment or re -treatment and this form must be on the job site to be picked up by the inspector at time of each inspection or the scheduled inspection will fail and a re -inspection fee charged FBC104.2.6 Certificate of Protective TreatMentforpreventfon of termites. Aweather resistantjobsitepos6ngboard shall be provided to receive duplicate Treatment Certificates as each required protective treatment /s completed, providing a copy for the person the permit is Issued to and another copy for the bu//ding permitfiles The Treatment Certificate shall provide the product used, identity of the applicator, time and date of the treatment, site location, area treated, chemical used, percent concentration and number ofgallons used, to estabi/sh a verifiable record of protective treatment. If the soil chemical barrier method for term/te prevention is used, final exterior treatment shall be completed prior to final bu/ld/ng approval. St Lucie County requires for the final inspection for CO, a Permanent Sticker to be placed on the electrical panel box cover, listing all the treatments and dates of applications. Revised 7/24/2014 �1 0 Mft rt 6 Port SL Lucie FBPE CA # 493D 607 NW Commodity Cove Port St Lucie, R. 34986 Phone:772-924-36751 Fer. 772-924-3560 Soil Nuclear Gauge Report Date: 2/27/2020 Test Method: ASTM D 6938 Client: RW Macy Concrete Construction, Inc. 5906 Nettle Path Drive Fort Pierce, FL 34951 Project: I q I I' O 5 Z� 20-8716.00 110 Beach Avenue Garage - CMT 110 Beach Avenue Port Saint Lucie, FL 34952 Test Results Test# Retest Of Test Date ProctorlD Method Soft Classification Optimum Moisture I%) Maximum Dry Density (pcf) In Place Moisture I%) In Place Dry Density (pcf) Probe Depth (in) Percent Compaction Minim" Comp. %) Remark 1 2118/20 P-1 WA 11.0 108.2 10.2 103.5 12 96 95 / 105 Pass 2 2/18120 P-1 NIA 11.0 108.2 9.8 103.9 12 96 95/105 Pass 3 2/18120 P-1 N/A 11.0 108.2 10.6 103.0 12 95 95 / 105 Pass Test Information Test # Test Location I Elevation Reference Gauge Make I Model / SN / Calibrated Field Technician 1 Below Slab Grade: Garage pad, Center. 0.1' Troxler / 3430! 24566 / Evans, Amber 2 Below Slab Grade: Garage pad, SW side. 0-1' Troxler 13430 / 24566 / I Evans, Amber 3 Below Slab Grade: Garage pad, NE side. 0.1' Troxler! 3430 / 245661 Evans, Amber Remarks Comments Pass: Tests results comply with specifications Tests am 'Direct Transmission' (Method A) unless probe depth is noted as _ 'eacescatter. Gauge calibration data on file with the testing agency. RECEIVED 1, 2, 3: Below stripped surface 0-1, 1-2' HCP=50+, > 95 % Compaction, PASS. HCP tests are empirically correlated to the FEB 2 7 2020 relative densityo the soil, ST. Lucie County, Permitting OCENSj'•.. �yw No 6321,V i Monda- •' ONAL tE ��.. Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Page 1 of 1