HomeMy WebLinkAboutSoil TreatmentPlanning & Development Services
Building & Code Regulation Division
2300 Virginia Ave
Fort Pierce, FL 34952
772-462-2172 Fax 772-462-6443
RECEIVED
FEB 2 7 2020
ST. Lucie County, Permitting
CERTIFICATE OF TERMITE TREATMENT
CONSTRUCTION SOIL TREATMENT
'PERMIT #: I G - C)5 a JOB AD
BUILDER/CONTRACTOR:
PEST CONTROL CONTRACTOR:��
PEST CONTROL LICENSE #: 7 \
: 9 ) b SfVA61- "L
h
We, the undersigned, hereby certify that we have pretreated the above described construction for
subterranean termites in accordance with the standards of the National Pest Control Association.
Square feet if area treated:360
Percentage of solution:
Date of Treatment: ea -I 1 2
Fdoting
1'�t Treatment
Re -Treat
Driveway
1" Treatment
Re -Treat
Other
11� Treatment
Re -Treat
Chemicals used: rhho54 e.c
Total gallons used:
Time ofTreatment: % Z-) S�
Sty lab p
1't Treatment
Re -Treat
Pools
1�` Treatment
R Treat
Pert for F' nspection
Z�
Sign re of Exterminator D to
Note. There must be a completed form for each required treatment or re -treatment and this form must be on the job
site to be picked up by the inspector at time of each inspection or the scheduled inspection will fail and a re -inspection
fee charged
FBC104.2.6 Certificate of Protective TreatMentforpreventfon of termites. Aweather resistantjobsitepos6ngboard
shall be provided to receive duplicate Treatment Certificates as each required protective treatment /s completed,
providing a copy for the person the permit is Issued to and another copy for the bu//ding permitfiles The Treatment
Certificate shall provide the product used, identity of the applicator, time and date of the treatment, site location, area
treated, chemical used, percent concentration and number ofgallons used, to estabi/sh a verifiable record of
protective treatment. If the soil chemical barrier method for term/te prevention is used, final exterior treatment shall
be completed prior to final bu/ld/ng approval.
St Lucie County requires for the final inspection for CO, a Permanent Sticker to be placed on
the electrical panel box cover, listing all the treatments and dates of applications.
Revised 7/24/2014
�1 0
Mft rt 6
Port SL Lucie
FBPE CA # 493D
607 NW Commodity Cove
Port St Lucie, R. 34986
Phone:772-924-36751 Fer. 772-924-3560
Soil Nuclear Gauge
Report Date: 2/27/2020
Test Method: ASTM D 6938
Client:
RW Macy Concrete Construction, Inc.
5906 Nettle Path Drive
Fort Pierce, FL 34951
Project: I q I I' O 5 Z�
20-8716.00
110 Beach Avenue Garage - CMT
110 Beach Avenue
Port Saint Lucie, FL 34952
Test Results
Test#
Retest
Of
Test
Date
ProctorlD
Method
Soft
Classification
Optimum
Moisture
I%)
Maximum
Dry Density
(pcf)
In Place
Moisture
I%)
In Place
Dry Density
(pcf)
Probe
Depth
(in)
Percent
Compaction
Minim"
Comp.
%)
Remark
1
2118/20
P-1
WA
11.0
108.2
10.2
103.5
12
96
95 / 105
Pass
2
2/18120
P-1
NIA
11.0
108.2
9.8
103.9
12
96
95/105
Pass
3
2/18120
P-1
N/A
11.0
108.2
10.6
103.0
12
95
95 / 105
Pass
Test Information
Test #
Test Location
I Elevation
Reference
Gauge
Make I Model / SN / Calibrated
Field Technician
1
Below Slab Grade: Garage pad, Center.
0.1'
Troxler / 3430! 24566 /
Evans, Amber
2
Below Slab Grade: Garage pad, SW side.
0-1'
Troxler 13430 / 24566 /
I Evans, Amber
3
Below Slab Grade: Garage pad, NE side.
0.1'
Troxler! 3430 / 245661
Evans, Amber
Remarks Comments
Pass: Tests results comply with specifications Tests am 'Direct Transmission' (Method A) unless probe depth is noted as _
'eacescatter. Gauge calibration data on file with the testing agency. RECEIVED
1, 2, 3: Below stripped surface 0-1, 1-2' HCP=50+, > 95 %
Compaction, PASS. HCP tests are empirically correlated to the FEB 2 7 2020