HomeMy WebLinkAboutRevised Plan (6/1/20)24'-O" FLOOR PL;4N UJ/ ELECTRIC TYPICAL NOTES: SCALE 1/4" = 1'-0" I. Contractor to verif ALL notes and dimensions prior to proceeding with work 2. Contractor to ST�ICTLY enforce ALL OSHA Requirements. 3. ALL Lumber to be used as Beam, Rafters, etc... to have a min. 1,500 psi fiber bending stress. 4. No dissimilar metals to touch. S. Drywall at ceilings shall be leveled and attached to bottom chord of trusses with screws per FBC R-102.3.5. ,o. ALL wood in contact with concrete shall be pressure treated. 1. ALL wall dimensions are nominal and not finished wall or stud dimensions. ELECTRIC NOTES: I. Use copper wire only, no aluminum. 2. Provide and wire all required smoke detectors as noted below. 3. Contractor to verify location of electrical service and provider 4. All NEW recessed cans to be Installed per NFPA requirements. S. All NEW branch circuits that supply 125v single phase 15 amp or 20 amp outlets shall be protected by combination -tape AFCi Circuit Breakers. 6. ALL new receptacles to be Tamper resistant AFCI. -f. Smoke Alarms shall be Installed in the following locations per FBC R31 -f: a) In each sleeping room. b) Outside each separate sleeping area in the Immediate Vicinity of the bedrooms. c) On each additional story of the dwelling d) ALL Smoke Alarms shall be Interconnected and hardwiredper FBC 8314,5 8. Electrician to complete electrical load calculation and panel schedules as required by the governing building department. A/C disc. �l3) #3 copper feed #6 cu ground I '/s" Conduit 1 -- - ground/to re=in slab I ELECTRICAL RiSER NTS Southeastern Metals 24 ga 5vCrimp Metal Roofing Installed per product approval FLU 11115.1 over Polyglass self adhered roofing underlagment over 19/32" CDX plywood attached to trusses per sheeting attachment diagram on roof plan Simpson HETA 20 or equal hurricane anchor at each truss with (10) IOd x 1 1/2" nails ( 24" o.c.) supporting Max. 1810lbs. uplift Galt'—Alum Metal drip on I" x 4" Drip on I" x 8" Fascia on 2" x 6" Sub -Fascia 24" 0. H, 5/8" thick stucco on 3/8" hi—rib lath attached to horizontal and vertical wood framing with nails or staples to provide --- no less than 1-3/4" penetration into horizontal wood framing and 3/4" penetration into vertical wood framing members 5/8" thick light textured stucco on typical concrete block construction sty bar vert. w/ 30" overlap at each filled cell 12 5 SLOP i i PRE-ENGINEERED ATTIC STORAGE TRUSSES AT 24"o.c. TYPICAL B1 ( shop drawings by manufacturer ) Bottom Chord to have min 201b live load. See tgpical wall reinforcing detail on sheet FIII cell with concrete and (l) 45 bar vert. (typical). Max. spacing shall not exceed 40" unless otherwise noted see foundation plan notes for spacing at openings 4" concrete slab with fibermesh OR 6"x6" 410/10 WWM on 6 mil Visqueen over clean compacted termite treated fill TYPICAL GARAGE SECTION Electrical S mbol Legend 12'-O" 12'-O" ® Recessed Can Light u �Q Double Pole Switch ® O Sb Dimmer Switch 00 II I I I I O I O O O O 00 Ceiling Mounted Light O Duplex Outlet Wall Mounted Light O O ,s Light with Pull Chain (attic) '8 Waterproof, ground fault interrupter© > Computer Connection Jack ® Install outlets 0 Flood Light ® Junction Box in garage 44" a.f.f. Electrical Panel (D Thermostat 8 GFCI ® O AC c A/C Disconnect ® O O Ceiling Fan with Light Kit ® Television Jack Telephone Jack v Ceiling Fan ® I x 4 Florescent Light ® Stleaker Hook—Up 0 Ceiling Mounted Light Dome Stills O Pendant Light ® GFcl Garage ® Carbon Monoxide Detector ® 2 x 4 Florescent Light Door — 0 Q1 Q Qj Opener U vi >L d) fa FB I 1 50Amp " Sub -panel I +j -dd� � 1 noutlets Install st I i I ala g a.f. . O 1 I I I GFCI I I O I I O 000 O O 00 FLOOR PL;4N UJ/ ELECTRIC TYPICAL NOTES: SCALE 1/4" = 1'-0" I. Contractor to verif ALL notes and dimensions prior to proceeding with work 2. Contractor to ST�ICTLY enforce ALL OSHA Requirements. 3. ALL Lumber to be used as Beam, Rafters, etc... to have a min. 1,500 psi fiber bending stress. 4. No dissimilar metals to touch. S. Drywall at ceilings shall be leveled and attached to bottom chord of trusses with screws per FBC R-102.3.5. ,o. ALL wood in contact with concrete shall be pressure treated. 1. ALL wall dimensions are nominal and not finished wall or stud dimensions. ELECTRIC NOTES: I. Use copper wire only, no aluminum. 2. Provide and wire all required smoke detectors as noted below. 3. Contractor to verify location of electrical service and provider 4. All NEW recessed cans to be Installed per NFPA requirements. S. All NEW branch circuits that supply 125v single phase 15 amp or 20 amp outlets shall be protected by combination -tape AFCi Circuit Breakers. 6. ALL new receptacles to be Tamper resistant AFCI. -f. Smoke Alarms shall be Installed in the following locations per FBC R31 -f: a) In each sleeping room. b) Outside each separate sleeping area in the Immediate Vicinity of the bedrooms. c) On each additional story of the dwelling d) ALL Smoke Alarms shall be Interconnected and hardwiredper FBC 8314,5 8. Electrician to complete electrical load calculation and panel schedules as required by the governing building department. A/C disc. �l3) #3 copper feed #6 cu ground I '/s" Conduit 1 -- - ground/to re=in slab I ELECTRICAL RiSER NTS Southeastern Metals 24 ga 5vCrimp Metal Roofing Installed per product approval FLU 11115.1 over Polyglass self adhered roofing underlagment over 19/32" CDX plywood attached to trusses per sheeting attachment diagram on roof plan Simpson HETA 20 or equal hurricane anchor at each truss with (10) IOd x 1 1/2" nails ( 24" o.c.) supporting Max. 1810lbs. uplift Galt'—Alum Metal drip on I" x 4" Drip on I" x 8" Fascia on 2" x 6" Sub -Fascia 24" 0. H, 5/8" thick stucco on 3/8" hi—rib lath attached to horizontal and vertical wood framing with nails or staples to provide --- no less than 1-3/4" penetration into horizontal wood framing and 3/4" penetration into vertical wood framing members 5/8" thick light textured stucco on typical concrete block construction sty bar vert. w/ 30" overlap at each filled cell 12 5 SLOP i i PRE-ENGINEERED ATTIC STORAGE TRUSSES AT 24"o.c. TYPICAL B1 ( shop drawings by manufacturer ) Bottom Chord to have min 201b live load. See tgpical wall reinforcing detail on sheet FIII cell with concrete and (l) 45 bar vert. (typical). Max. spacing shall not exceed 40" unless otherwise noted see foundation plan notes for spacing at openings 4" concrete slab with fibermesh OR 6"x6" 410/10 WWM on 6 mil Visqueen over clean compacted termite treated fill TYPICAL GARAGE SECTION Electrical S mbol Legend $ Single Pole Switch ® Recessed Can Light u �Q Double Pole Switch ® Egeball Recessed Can Light Sb Dimmer Switch (M Exhaust Fan P Push Button Switch Ceiling Mounted Light =09 Duplex Outlet Wall Mounted Light Special Receptacle ,s Light with Pull Chain (attic) '8 Waterproof, ground fault interrupter© > Computer Connection Jack ® Floor Duplex Outlet �2 Flood Light ® Junction Box m Electrical Panel (D Thermostat 8 Electrical Meter ® Central Vac AC c A/C Disconnect ® Smoke Detector W Ceiling Fan with Light Kit ® Television Jack Telephone Jack v Ceiling Fan ® I x 4 Florescent Light ® Stleaker Hook—Up 0 Ceiling Mounted Light Dome Stills ♦ Pendant Light ® Motion Detector l closet light ) ® Carbon Monoxide Detector ® 2 x 4 Florescent Light E)� Int Scale 1/2„ = 1'-0" Verify all stucco banding and trim per elevations Stucco return Attach door to block wall with 1/4" dia. x 3" tap -cons with min. 1 1/2" penetration at 12" o.c. max and (." o.c. max from each corner thru I" x 8" PT Buck See door schedule and floor plan for size and locations nstall door per product approval bg mfg Drywall return See typical wall sections for Interior drywall finish notes verify filled cell count per floor plans at window ,lambs Exterior Door Jamb Detail NTS Seal ALL concrete block iambs prior to buck per FSC R103.8 using any approved sealant VERiFY ALL SiLL MATERIAL WITH OWNER PRiOR TO ORDERING VERIFY ALL ROUGH OPENING SIZES WITH THEIR RESPECTIVE MANUFACTURER PRIOR TO INSTALLING MASONRY Drywall returr Sill - verify material and with owner pr to ordering E> Int Window Jamb Detall Verify all stucco banding and trim per elevations Stucco return Attach window to block wall with 1/4" dia. x 3" tap -cons with min. 1 1/2" penetration at 12" o.c. max and 6" o.c. max from each corner thru I" x 4" PT Buck See window schedule and floor plan for size and locations install window per product approval by mfg Drywall return See typical wall sections for Interior drywall finish notes verify filled cell count per floor plans at window ,lambs NTS Lintel - see plans for size and steel req. Attach window to block wall with 1/4" dm. x 3' tap—cons with min. 11/2" penetration at 12" o.c. max and V o.c. max from each corner thru 1" x 4' PT Buck stucco return See window schedule and floor plan for size and locations Stucco finish over sill slope for drainage Pour concrete sill over tin cap Section Window Head Sill NTS Digitally signed by Daniel Braden Date: 2020.05.29 08:34:41 -04'00' 11 U_ OR Q N Q ILS ` RN u �Q U U U_ OR SHEET NO: :2. OF 3. JOB NUMBER: D6C R. 0. ® ° �� o AR 91770 N (M o O Uj u .zLLI��u o > N N03 U < Z # I NN ~ O a- aj U U r-r� -- -- — Q1 Q Qj 1L U vi >L d) fa (y r Q3 " +j -dd� to SHEET NO: :2. OF 3. JOB NUMBER: D6C R. 0. ® ° �� o AR 91770