THRESHOLD INSPECTION REPORT
OCEAN HARBOR NORTH CONDOMINIUMS – BLDG. B CONCRETE REPAIRS
5159 N. HWY. A1A, FT. PIERCE, FL 34949
SLC BUILDING PERMIT NUMBER: 1912-0284
PROJECT NAME: Ocean Harbor N. Condos – Bldg. B
Concrete Repairs DATE: May 29, 2020
CLIENT: Elliott Merrill Community Management LOCATION: Ft. Pierce, FL
CONTRACTOR: Structure-Con PROJECT MGR: Mr. Khris McConnell
INSPECTED BY: Todd Rhoten WEATHER: Sunny
WORK INSPECTED:
Unit 714 – Pre pour
OBSERVATIONS:
• 16” of the entire concrete balcony edge has been chipped and removed to expose all corroded reinforcing bars.
• A new #5 bar was placed at the perimeter and lapped with existing as recommended as per last report.
• All reinforcing has been power tool cleaned and coated with the approved corrosion inhibitor.
• Shoring is in place and accordance with design document.
• Form boards are in progress.
Concrete pour is scheduled for Monday, June 1st @ 9am.
All work to date complies with the design plans.
RECOMMENDATION:
• Contractor to apply an additional coat of corrosion inhibitor prior to placing concrete.
_
____________________________ _________________________________
Michael Lue, P.E. Todd Rhoten, Inspector
M L Engineering Inc.
Consulting Engineers
Threshold Inspector
2030 37th Avenue
Vero Beach, Florida 32960
Phone: (772) 569-1257
Fax: (772) 569-4041
www.mlengineeringinc.com
Project No. 19-229 Report No. 4
Project Manager:
Building Official:
Contractor:
File
Mr. Gene Ross – Elliott Merrill Community Mgmt.
St. Lucie County Bldg. Dept.
Mr. Robert Stark – Structure-Con
Mr. Khris McConnel – Structure Con
Page 2 of 2
Pic 1
Unit 714
Shoring is in place at the unit below.
Pic 2
Unit 714
South end edge repair
Pic 3
Unit 714
North end of balcony edge.