HomeMy WebLinkAboutCompaction Test 6/1/20mw"ArdamanSoll Nuclear Gauge 8t Associates, Inc. Permit # 2004-0384 Renar Development Corp. 113-15-66-5434B Report Date: 6/1/2020 3725 S. East Ocean. Boulevard, Suite 101 Morningside Residential Lots _ ___---- Port St. Lucie Branch Test Method: ASTM D 6938 S wart; FL 34996 - Fort Pierce Florida CA No. 5950 460 NW Concourse Place, Unit 1j�'f�/; Fort Pierce, FL Port St. Lucie, FL 34986 i / (/��- Phone: 772-878-0072 �r /� (� Client: Project: AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 1 of 2 THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDIN( OUR WRITTEN APPROVAL. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture N Maximum Dry Density (pcf) In Place Moisture N In Place Dry Density (pcf) Probe Depth (in) Percent Compaction Min Comp. N Remark 297 5/29/20 20-153 (Modified) A 9.5 116.0 12.7 112.2 12 97 95 Pass 298 5/29/20 20-153 (Modified) A 9.5 116.0 13.0 111.4 12 96 95 Pass 299 5/29/20 20-153 (Modified) A 9.5 116.0 13.1 112.9 12 97 95 Pass 300 5/29/20 20-153 (Modified) A 9.5 116.0 12.8 113.2 12 98 95 Pass 301 5/29/20 20-153 (Modified) A 9.5 116.0 12.9 113.8 12 98 95 Pass 302 5/29/20 20-153 (Modified) A 9.5 116.0 12.4 112.4 12 97 95 Pass 303 5/29/20 20-153 (Modified) A 9.5 116.0 11.8 111.8 12 96 95 Pass 304 5/29/20 20-153 (Modified) A 9.5 116.0 12.2 112.9 12 97 95 Pass Test Information Test # Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 297 Building Pad Fill: 9500 Silver Sands Lane, Lot 01. N Corner -1.0 Top of Pad Troxler / T-3430 / 21330 / Tech, Port St. Lucie 298 Building Pad Fill: 9500 Silver Sands Lane, Lot 01. E Corner -1.0 Top of Pad Troxler / T-3430 / 21330 / Tech, Port St. Lucie 299 Building Pad Fill: 9500 Silver Sands Lane, Lot 01. S Corner -1.0 Top of Pad Troxler / T-3430 121330 / Tech, Port St. Lucie 300 Building Pad Fill: 9500 Silver Sands Lane, Lot 01. W Corner -1.0 Top of Pad Troxler / T-3430 / 21330 / Tech, Port St. Lucie 301 Footings: 9500 Silver Sands Lane, Lot 01. W Side -2.0 Top of Pad Troxler / T-3430 / 21330 / Tech, Port St. Lucie 302 Footings: 9500 Silver Sands Lane, Lot 01. S Side -2.0 Top of Pad Troxler / T-3430 / 21330 / Tech, Port St. Lucie 303 Footings: 9500 Silver Sands Lane, Lot 01. E Side -2.0 Top of Pad Troxler / T-3430 / 21330 / Tech, Port St. Lucie 304 Footings: 9500 Silver Sands Lane, Lot 01. N Side -2.0 Top of Pad Troxler / T-3430 / 21330 / Tech, Port St. Lucie Remarks Comments Pass: Density Pass Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter'. Gauge calibration data on file with the testing agency. AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 1 of 2 THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDIN( OUR WRITTEN APPROVAL. Ow'wArdamanSoil Nuclear Gauge & Associates, Inc. Permit # 2004-0384 Report Date: 6/1/2020 Port St. Lucie Branch Test Method: ASTM D 6938 Florida CA No. 5950 460 NW Concourse Place, Unit 1 Port Sl. Lucie, FL 34986 Phone: 772-878-0072 Client: Renar Development Corp. 3725 S. East Ocean Boulevard, Suite 101 Stuart, FL 34996 le'r r f Project: 113-15-66-5434B Morningside Residential Lots Fort Pierce Fort Pierce, FL Z �� 6r1 -fir ��Cr R. �lii\• ^,�I # No. 63911 :�A �r 4rx�Op- i.4 .: r CONAL 9#'y,� . 0/11111 IW' This item has been digitally signed and sealed by Branch Manager Dan J. Zrallack, P.E. on Jun 01, 2020 using a Digital Signature. Printed copies of this document are not considered signed and sealed and the SHA authentication code must be verified on any electronic copies. AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 2 of 2 THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDIN( OUR WRITTEN APPROVAL.