Loading...
HomeMy WebLinkAbout1 Inch 26g - 07.31.2017 (FLPA # 17022.5)Product Report Manufacturer: Extreme Metal Fabricators, LLC. Compliant with Florida Building Code 2017 (6th ed.) Compliant with Florida Product Approval Rule # 61G20-3 Compliant: Keystone Certifications Product: 1" Nailstrip 26GA Steel Roof Panel FBC Sec. 1507.4.2 Yield strength: 50 ksi min.; Attached to min. 15/32" plywood or Wood Deck w/ 0.42 specific gravity with 16" Coverage (Max.) Rib Height 1" 2160 SW Poma Drive Palm City, FL 34990 772 872-8034 Corrosion Resistant Compliant: FBC Sec. 1507.4.3 Fastener 1: #10 x 1" (min.) Pancake Head Wood Screw to penetrate 3/16" (min.) thru bottom of support. Adhesive/Sealant : Bostik 915™ Chem-Chalk one component, polyurethane adhesive with 3/16" continuous bead application along base of male rib vertical flange at each panel seam. Underlayment: To be compliant with FBC Sec 1507.1.1 Slope: Shall be in compliance with FBC Sec. 1507. Install Details: Table A Allowable Loads METHOD 1 METHOD 2 DESIGN PRESSURE* -86 PSF -97.25 PSF FASTENER SPACING 6" o.c.6" o.c. SEAM ADHESIVE Not required 3/16" continuous bead (see details) Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: 1527 UL 580-06 & UL 1897-04 TEST REPORT D8133.01-450-18 06/30/15 Specimen #1 & #2 EQUIVALENCY: UL1897-04 is equivalent to Test Standard UL1897-12. Certificate of Independence: Locke Bowden, P.E. does not have, not will acquire a financial inttntSUtfQI'}� company manufacturing or distributing products,,, ... 0 8 , •• under this evaluation. ,,,, �\:- · 0 V/1. :.',,,. Locke Bowden, P.E. is not owned, operated, or controll��Y'S,_,ifil?j� �.a.��f.Ji.,cturer, or distributing products under this report. fff!v�7 :. • • :-: seal •--'()' a:-: t-,."l•. STAT£0F ;�I.Ji/ -;. 0 • /:". " •. ::,.:' .�;.<'..(\•• lOR10r.,•,..:--.-/ � ,·.r, • • • • .,. ·•',,. vs, • • c··� . ,,,,, 1 0NAL \., .:····l,:1�:� .• uH\ • Main field Perimeter *Design Pressure margin of safety 2:1 16" 1"3/4" Panel Profile  16" o.c. Integral Snap Lock Fastener #10 × 1" Min. per Table "A" Pancake Head Wood Screw Deck: - 15/32" or greater Plywood, or - Wood plank For METHOD 2: Apply 3/16" Bead Bostik 915™ Sealant Continuous Along Male Rib Vertical Flange (Typical Fastening Pattern Across Width)  FL 17022.5 1.0 Nail Strip (26GA Steel), 16" Wide Roof Panel - Details 1.Underlayment to be compliance with current Florida Building Code (FBC)2017 6th ed.. 2.Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer’s installation reference. 3.Products are compliant for State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D 4.Engineering analysis for “project specific approval by local authorities w/jurisdiction is allowed by other registered engineers. 5.Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6.Support framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7.This report does not imply warranty, installation, recommended product use outside of this report. Limitations: Per Table "A"1" Nail Strip Roof Panel Seam Adhesive Application: For Method 2 Apply 3/16" Bead Bostik 915™ Sealant Continuous Along Male Rib Vertical Flange (Refer to Table "A") Fastener #10 × 1" Min. per Table "A" Pancake Head Wood Screw Deck: - 15/32" or greater Plywood, or - Wood plank  Isometric View  FL 17022.5 1.0 Nail Strip (26GA Steel), 16" Wide Roof Panel - Details