Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method LL.CA V C Project Name: Adams Homes -2169 Model-8301 Cristelle cour Builder Name: Adams Homes Street: 8301 Cristelle Court Permit Office: St. Lucie County DEC I 7 "'0?9 City, State, Zip: Ft. Pierce , FL, 34951 Permit Number: Owner. Adams Homes - 2169 Model Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Cli 126H&1e2 ounty, Permitting 1. New construction or existing New (From Plans) 9. Wall Types (2046.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1772.00 ft2 b. Frame - Wood, Adjacent R=11.0 274.00 ft2 3. Number of units, if multiple family 1 c. WA R= ft2 4. Number of Bedrooms 4 d. NIA R= ft2 10. Ceiling Types (2151.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 2151.00 ft2 6. Conditioned floor area above grade (112) 2151 b. WA R= ft2 Conditioned floor area below grade (ft2) 0 c. NIA R= ft2 11. Ducts R ft2 7. Windows(267.5 sqft.) Description _ Area a. Sup: Attic, Ret: AH, AH: AH 6 115 a. U-Factor: Sgl, U=0.33 192.50 ft2 SHGC: SHGC=0.23 b. U-Factor: Sgl, U=0.33 75.00 ft2 12. Cooling systems kBlu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 40.0 SEER:14.50 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor. N/A 112 a. Electric Heat Pump 42.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 3.402 ft. Area Weighted Average SHGC: 0.224 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (2151.0 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 2151.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits CF, Pslal Total Proposed Modified Loads: 66.02 Glass/Floor Area: 0.124 PASS Total Baseline Loads: 72.23 I hereby certify that the plans and specifications covered by Review of the plans and S1- this calculation are in compliance with the Florida Energy specifications covered by this OF'4KE 4V , a' 0 Code. calculation indicates compliance 4 with the Florida Energy Cade. Ir O PREPARED BY: 1 �rL/��y! Before construction is completed v DATE: in this building will be inspected for compliance with Section 553.908 O y I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Eaftr Cade. GOp WB OWNER/AGEN BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). V: I r01?*4 10/28/2019 9:59 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Pagel of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Adams Homes - 2169 Model - Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2151 Lot # Owner Name: Adams Homes - 2169 Model Total Stories: 1 Block/Subdivision: r # of Units: 1 Worst Case: - No PlatBook: Builder Name: Adams Homes Rotate Angle: 0 Street: 8301 Cristelle Court Permit Office: St. Lucie County Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: Ft. Pierce, Family Type: Single-family FL, 34951 New/Existing: New (From Plans) Comment: CLIMATE _ / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2151 19428 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Sunroom/Bedroom 164 1312 No 1 1 1 Yes Yes Yes 2 Bedroom 3 174 1392 No 1 1 1 Yes Yes Yes 3 Bath 75 600 No 0 1 Yes Yes Yes 4 Closet 20 160 No 0 1 Yes Yes Yes 5 AH 16 128 No 0 1 No Yes Yes 6 Hall 58 464 No 0 1 No Yes Yes 7 Bedroom 2 156 1248 No 1 1 1 Yes Yes Yes 8 Family Room 391 3910 No 2 1 Yes Yes Yes 9 Living Room 115 1150 No 1 1 Yes Yes Yes 10 Foyer 82 820 No 0 1 Yes Yes Yes 11 Dining Room 130 1300 No 1 1 Yes Yes Yes 12 Nook 60 480 No 0 1 Yes Yes Yes 13 Kitchen 158 1580 Yes 1 1 No Yes Yes 14 Master Bedroom 234 2340 No 2 1 1 Yes Yes Yes 15 WIC 1 34 272 No 0 1 Yes Yes Yes 16 Master Bathroom 99 792 No 0 1 Yes Yes Yes 17 WIC 2 34 272 No 0 1 Yes Yes Yes 18 Linen 20 160 No 0 1 No Yes Yes 19 Utility 84 672 No 0 1 No Yes Yes 20 Hall 35 280 No 0 1 No Yes Yes 21 Pantry 12 96 No 0 1 No Yes Yes 10/28/2019 9:59 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Sunroom/Bedroo 34 ft 0 164 112 ____ 1 0 0 2 Slab -On -Grade Edge Insulatio Bedroom 3 12 ft 0 174 ft2 _ 1 0 0 3 Slab -On -Grade Edge Insulatio Bath 9 ft 0 75 112 1 0 0 4 Slab -On -Grade Edge Insulatio Closet 4 ft 0 20 ft2 — 1 0 0 5 Slab -On -Grade Edge Insulatio AH 1 It 0 16 ft2 1 0 0 6 Slab -On -Grade Edge Insulatio Hall t It 0 58 ft' — 1 0 0 7Slab-On-Grade Edge Insulatio Bedroom 2 33 ft 0 156 ft2 — 1 0 0 8 Slab -On -Grade Edge Insulatio Family Room 17 ft 0 391 ft2 — 1 0 0 9 Slab -On -Grade Edge Insulatio Living Room 9 ft 0 115 ft2 — 1 0 0 10SIab-On-Grade Edge Insulatio Foyer 7 ft 0 82 ft2 _ 1 0 0 11SIab-On-Grade Edge Insulatio Dining Room 11 It 0 130 ft2 _- 1 0 0 12SIab-On-Grade Edge Insulatio Nook loft 0 60 ft2 1 0 0 13Slab-On-Grade Edge Insulatio Kitchen 1 It 0 158 ft2 — 1 0 0 14SIab-On-Grade Edge Insulatio Master Bedroom 38 It 0 234 ft2 -- 1 0 0 15SIab-On-Grade Edge Insulatio WIC 1 6 ft 0 34 ft2 ___ 1 0 0 16SIab-On-Grade Edge Insulatio Master Bathroom 5 ft 0 99 ft2 _—_ 1 0 0 17SIab-On-Grade Edge Insulatio WIC 2 6 ft 0 34 ft' ____ 1 0 0 18SIab-On-Grade Edge Insulatio Linen 1 ft 0 20 ft2 ____ 1 0 0 19SIab-On-Grade Edge Insulatio Utility 1 It 0 84 ft2 ____ 1 0 0 20SIab-On-Grade Edge Insulatio Hall 1 1 ft 0 35 ft2 __ 1 0 0 21SIab-On-Grade Edge Insulatio Pantry 1 ft 0 12 ft2 ___ 1 0 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2406 ft2 0 ft2 Medium N 0.6 No 0.9 No 0 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 2151 ft2 N N 10/28/2019 9:59 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Sunroom/Bedroo 30 Batt 164 ft' 0.1 Wood 2 Under Attic (Vented) Bedroom 3 30 Batt 174 ft' 0.1 Wood 3 Under Attic (Vented) Bath 30 Batt 75 ft' 0.1 Wood 4 Under Attic (Vented) Closet 30 Batt 20 ft' 0.1 Wood 5 Under Attic (Vented) AH 30 Batt 16 ft' 0.1 Wood 6 Under Attic (Vented) Hall 30 Batt 58 ft' 0.1 Wood 7 Under Attic (Vented) Bedroom 2 30 Batt 156 ft' 0.1 Wood 8 Under Attic (Vented) Family Room 30 Batt 391112 0.1 Wood 9 Under Attic (Vented) Living Room 30 Batt 115 ft' 0.1 Wood 10 Under Attic (Vented) Foyer 30 Batt 82 ft' 0.1 Wood 11 Under Attic (Vented) Dining Room 30 Batt 130 ft' 0.1 Wood 12 Under Attic (Vented) Nook 30 Batt 60 ft' 0.1 Wood 13 Under Attic (Vented) Kitchen 30 Batt 158 ft' 0.1 Wood 14 Under Attic(Vented) Master Bedroom 30 Batt 234 ft' 0.1 Wood 15 Under Attic (Vented) WIC 1 30 Batt 34 ft' 0.1 Wood 16 Under Attic (Vented) Master Bathroom 30 Batt 99 ft' 0.1 Wood 17 Under Attic (Vented) WIC 2 30 Batt 34 ft' 0.1 Wood 18 Under Attic (Vented) Linen 30 Batt 20 ft' 0.1 Wood 19 Under Attic (Vented) Utility 30 Batt 84 W 0.1 Wood 20 Under Attic (Vented) Hall 1 30 Batt 35 ft' 0.1 Wood 21 Under Attic (Vented) Pantry 30 Batt 12 ft' 0.1 Wood WALLS Adjacent S ace P Cavity Width Height Sheathing Framing Solar Below o 1 NE Exterior Concrete Block - Ext In9dnroom/Bed 4.1 13 0 8 0 104.0 ft' 0 0 0.6 0 2 SE Exterior Concrete Block -Ext InWnroom/Bed 4.1 7 0 8 0 56.0 ft' 0 0 0.6 0 _ 3 NW Exterior Concrete Block- Ext InSdnroom/Bed 4.1 14 0 8 0 112.0 ft' 0 0 0.6 0 4 NW Exterior Concrete Block- Ext Inst9edroom 3 4.1 12 0 8 0 96.0 ft' 0 0 0.6 0 5 NW Exterior Concrete Block- ExtInsul Bath 4.1 9 0 8 0 72.0 ft' 0 0 0.6 0 6 NW Exterior Concrete Block - Ext Insul Closet 4.1 4 0 8 0 32.0 ft' 0 0 0.6 0 7 SE Exterior Concrete Block - Ext InstBedroom 2 4.1 8 0 8 0 64.0 ft' 0 0 0.6 0 8 SW Exterior Concrete Block - Ext InsrBedroom 2 4.1 13 0 8 0 104.0 ft' 0 0 0.6 0 9 NW Exterior Concrete Block - Ext InsrBedroom 2 4.1 12 0 8 0 96.0 ft' 0 0 0.6 0 10 NE Exterior Concrete Block - Ext IngAmily Room 4.1 17 0 10 0 170.0 ft' 0 0 0.6 0 11 SW Exterior Concrete Block- Ext Inslutring Room 4.1 9 0 10 0 90.0 ft' 0 0 0.6 0 12 SE Exterior Concrete Block- Ext Insul Foyer 4.1 1 0 10 0 10.0 ft' 0 0 0.6 0 13 SW Exterior Concrete Block- Ext Insul Foyer 4.1 6 0 10 0 60.0 ft' 0 0 0.6 0 14 SW Exterior Concrete Block- Ext InsDIning Room 4.1 11 0 10 0 110.0 ft' 0 0 0.6 0 15 NE Exterior Concrete Block - Ext Insul Nook 4.1 10 0 8 0 80.0 ft' 0 0 0.6 0 16 NE Exterior Concrete Block - Ext InSdhster Bedro 4.1 18 0 10 0 180.0 ft' 0 0 0.6 0 17 SE Exterior Concrete Block - Ext InSdhster Bedro 4.1 13 0 10 0 130.0 ft' 0 0 0.6 0 _ 18 NW Exterior Concrete Block - Ext Inddhster Bedro 4.1 7 0 10 0 70.0 ft' 0 0 0.6 0 19 SE Exterior Concrete Block - Ext Insul WIC 1 4.1 6 0 8 0 48.0 ft' 0 0 0.6 0 10/28/2019 9:59 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 20 SE Exterior Concrete Block - Ext InLUster Bathro 4.1 5 0 8 0 40.0 ft' 0 0 0.6 0 21 SE Exterior Concrete Block - Ext Insul WIC 2 4.1 6 0 8 0 48.0 ft' 0 0 0.6 0 22 N Garage Frame - Wood Dining Room 11 12 10 120.0 ft' 0 0.23 0.600000 0 23 N Garage Frame - Wood Pantry 11 1 10 10.0 ft' 0 0.23 0.600000 0 24 N Garage Frame - Wood Utility 11 7 8 55.0 ft' 0 0.23 0.600000 0 25 N Garage Frame - Wood Linen 11 5 8 40.0 ft' 0 0.23 0.600000 0 26 N Garage Frame - Wood WIC 2 11 6 8 48.0 W 0 0.23 0.600000 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In _ 1 SE Wood Sunroom/Bed None .39 2 10 6 10 19.4 ft' 2 NE Wood Family Room None .39 2 10 6 10 19.3 ft' 3 SW Wood Foyer None .39 3 6 10 20.4 ft' 4 NW Wood Master Bedro None .39 2 10 6 10 19.4 ft' WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NE 1 Vinyl Low-E Single Yes 0.33 0.23 N 30.0 ft' 2 ft 0 in 0 It 7 in None None 2 NW 4 Vinyl Low-E Single Yes 0.33 0.23 N 15.0 ft' 2 ft 0 in 0 ft 7 in None None 3 NW 5 Vinyl Low-E Single Yes 0.33 0.23 N 9.0 ft' 2 ft 0 in 0 ft 7 in None None 4 SW 8 Vinyl Low-E Single Yes 0.33 0.21 N 15.0 ft' 2It 0 in 0 ft 7 in None None 5 NE 10 Vinyl Low-E Single Yes 0.33 0.23 N 45.0 ft' 7 ft 0 in 0 ft 7 in None None 6 SW 11 Vinyl Low-E Single Yes 0.33 0.23 N 7.0 ft' 2 ft 0 in 0 ft 7 in None None 7 SW 11 Vinyl Low-E Single Yes 0.33 0.21 N 30.0 ft' 2 ft 0 in 0 ft 7 in None None 8 SW 13 Vinyl Low-E Single Yes 0.33 0.23 N 5.8 ft' 2 ft 0 in 0 ft 7 in None None 9 SW 13 Vinyl Low-E Single Yes 0.33 0.23 N 13.7 ft' 2 ft 0 in 0 ft 7 in None None 10 SW 14 Vinyl Low-E Single Yes 0.33 0.23 N 7.0 ft' 2 ft 0 in 0 ft 7 in None None 11 SW 14 Vinyl Low-E Single Yes 0.33 0.21 N 30.0 ft' 2 ft 0 in 0 ft 7 in None None 12 NE 15 Vinyl Low-E Single Yes 0.33 0.23 N 30.0 ft' 7 ft 0 in 0 ft 7 in None None 13 NE 16 Vinyl Low-E Single Yes 0.33 0.23 N 30.0 ft' 2 ft 0 in 0 ft 7 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 380 ft' 380 ft' 31 ft Sit 11 10/28/2019 9:59 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000402 2266.6 124.43 234.02 .1461 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.2 42 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 14.5 40 kBtu/hr 1200 cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft' DUCTS — Supply — V # Location R-Value Area ---- Return — Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT ON RLF HVAC # Heat Cool 1 Attic 6 115 ft' AH 20 ft' Default Leakage AH (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y [[X�]Mar HeFebJan Feb [X] Mar Ceiling Fans: r ay4 [ [X] [X] Apr May 4X� Jun ri Jul r ] Aug [ ] Sep l 1 Jun 1 Jul (1 Aug [ 1 Sep E Oct [ Nov Dec rI)C') [ ] Dec 10/28/2019 9:59 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT Therrpostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM fib fib 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Sunroom/Bedroom Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 3 Default(8 lbs/sq.ft. ft' ft 0.3 Bath Default(8 lbs/sq.ft. ft2 ft 0.3 Closet Default(8 lbs/sq.ft. ft' ft 0.3 AH Default(8 lbs/sq.ft. ft2 ft 0.3 Hall Defaull(8lbs/sq.ft. ft2 ft 0.3 Bedroom 2 Default(8lbs/sq.ft. ft2 ft 0.3 Family Room Default(8 Ibs/sq.ft. ft2 ft 0.3 Living Room Default(8 lbs/sq.ft. ft2 ft 0.3 Foyer Default(8 Ibs/sq.ft. ft2 ft 0.3 Dining Room Default(8 lbs/sq.ft. ft2 ft 0.3 Nook Default(8 lbs/sq.ft. ft2 ft 0.3 Kitchen Default(8 Ibs/sq.ft. ft2 ft 0.3 Master Bedroom Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 Master Bathroom Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 2 Default(8lbs/sq.ft. ft2 ft 0.3 Linen Default(8lbs/sq.ft. ft2 ft 0.3 Utility Default(8 lbs/sq.ft. ft2 ft 0.3 Hall Default(8 lbs/s .ft. ft2 ft 0.3 Pantry 10/28/2019 9:59 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Adams Homes - 2169 Model -8301 Cristelle cour Builder Name: Adams Homes Street: 8301 Cristelle Court Permit Office: St. Lucie County City, State, Zip: Ft. Pierce , FL, 34951 Permit Number. id Owner: Adams Homes -2169 Model Jurisdiction: U w Design Location: FL, Fort Pierce xO COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barriershall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks orjoints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an dropped ceiling/soffit y 9 /soffit the insulation and any gaps in the air barrier shall be sealed. ai shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exteriorwalls, or insulation that on installation readily conforms to available space shall extend behind ploing and wiring, Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exteror walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire snrinkler cover plates and walls or ceilings. a. in addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 10/28/2019 10:00 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 91 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location AH 3. No, of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 40.0 a) Split system SEER 14.5 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2151 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.330 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.224 14. Heafing system: Capacity 42.0 c) Area 7c. 267.5 a) Split system heat pump HSPF 8.2 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.95 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 0 Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 11.0 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans Yes a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signatur p Date:T�/i/ Address of New Home: 8301 Cristelle Court City/FL Zip: Ft. Pierce, FL 34951 10/28/2019 10:00:16 AM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: ADAMS HOMES- 1635 MODEL Builder Name: ADAMS HOMES Street: 5404 LUGO STREET Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Y Owner. Jurisdiction: ST LUCIE COUNTY w Design Location: FL, Fort Pierce = O COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls Thejunction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls Thejunction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottorr to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air fight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring a plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended bythe manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or Ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 10/25/2019 1:14 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1