HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
LL.CA V C
Project Name: Adams Homes -2169 Model-8301 Cristelle cour
Builder Name: Adams Homes
Street: 8301 Cristelle Court
Permit Office: St. Lucie County
DEC I 7 "'0?9
City, State, Zip: Ft. Pierce , FL, 34951
Permit Number:
Owner. Adams Homes - 2169 Model
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Cli
126H&1e2 ounty, Permitting
1. New construction or existing New (From Plans)
9. Wall Types (2046.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior R=4.1 1772.00 ft2
b. Frame - Wood, Adjacent
R=11.0 274.00 ft2
3. Number of units, if multiple family 1
c. WA
R= ft2
4. Number of Bedrooms 4
d. NIA
R= ft2
10. Ceiling Types (2151.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=30.0 2151.00 ft2
6. Conditioned floor area above grade (112) 2151
b. WA
R= ft2
Conditioned floor area below grade (ft2) 0
c. NIA
R= ft2
11. Ducts
R ft2
7. Windows(267.5 sqft.) Description _ Area
a. Sup: Attic, Ret: AH, AH: AH
6 115
a. U-Factor: Sgl, U=0.33 192.50 ft2
SHGC: SHGC=0.23
b. U-Factor: Sgl, U=0.33 75.00 ft2
12. Cooling systems
kBlu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
40.0 SEER:14.50
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor. N/A 112
a. Electric Heat Pump
42.0 HSPF:8.20
SHGC:
Area Weighted Average Overhang Depth: 3.402 ft.
Area Weighted Average SHGC: 0.224
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (2151.0 sqft.) Insulation Area
EF: 0.950
a. Slab -On -Grade Edge Insulation R=0.0 2151.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
CF, Pslal
Total Proposed Modified Loads: 66.02
Glass/Floor Area: 0.124
PASS
Total Baseline
Loads: 72.23
I hereby certify that the plans and specifications covered by
Review of the plans and
S1-
this calculation are in compliance with the Florida Energy
specifications covered by this
OF'4KE
4V , a' 0
Code.
calculation indicates compliance
4
with the Florida Energy Cade.
Ir O
PREPARED BY: 1 �rL/��y!
Before construction is completed
v
DATE: in
this building will be inspected for
compliance with Section 553.908
O y
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Eaftr Cade.
GOp WB
OWNER/AGEN
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
V: I r01?*4
10/28/2019 9:59 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Pagel of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Adams Homes - 2169 Model -
Bedrooms:
4
Address Type:
Street Address
Building Type:
User
Conditioned Area:
2151
Lot #
Owner Name:
Adams Homes - 2169 Model
Total Stories:
1
Block/Subdivision:
r # of Units:
1
Worst Case: -
No
PlatBook:
Builder Name:
Adams Homes
Rotate Angle:
0
Street:
8301 Cristelle Court
Permit Office:
St. Lucie County
Cross Ventilation:
No
County:
St. Lucie
Jurisdiction:
Whole House Fan:
No
City, State,
Zip:
Ft. Pierce,
Family Type:
Single-family
FL, 34951
New/Existing:
New (From Plans)
Comment:
CLIMATE
_ /
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI
39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
2151
19428
SPACES
Number
Name
Area
Volume Kitchen
Occupants
Bedrooms
Infil ID
Finished Cooled
Heated
1
Sunroom/Bedroom
164
1312 No
1
1
1
Yes
Yes
Yes
2
Bedroom 3
174
1392 No
1
1
1
Yes
Yes
Yes
3
Bath
75
600 No
0
1
Yes
Yes
Yes
4
Closet
20
160 No
0
1
Yes
Yes
Yes
5
AH
16
128 No
0
1
No
Yes
Yes
6
Hall
58
464 No
0
1
No
Yes
Yes
7
Bedroom 2
156
1248 No
1
1
1
Yes
Yes
Yes
8
Family Room
391
3910 No
2
1
Yes
Yes
Yes
9
Living Room
115
1150 No
1
1
Yes
Yes
Yes
10
Foyer
82
820 No
0
1
Yes
Yes
Yes
11
Dining Room
130
1300 No
1
1
Yes
Yes
Yes
12
Nook
60
480 No
0
1
Yes
Yes
Yes
13
Kitchen
158
1580 Yes
1
1
No
Yes
Yes
14
Master Bedroom
234
2340 No
2
1
1
Yes
Yes
Yes
15
WIC 1
34
272 No
0
1
Yes
Yes
Yes
16
Master Bathroom
99
792 No
0
1
Yes
Yes
Yes
17
WIC 2
34
272 No
0
1
Yes
Yes
Yes
18
Linen
20
160 No
0
1
No
Yes
Yes
19
Utility
84
672 No
0
1
No
Yes
Yes
20
Hall
35
280 No
0
1
No
Yes
Yes
21
Pantry
12
96 No
0
1
No
Yes
Yes
10/28/2019 9:59 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio
Sunroom/Bedroo
34 ft
0
164 112
____
1
0
0
2 Slab -On -Grade Edge Insulatio
Bedroom 3
12 ft
0
174 ft2
_
1
0
0
3 Slab -On -Grade Edge Insulatio
Bath
9 ft
0
75 112
1
0
0
4 Slab -On -Grade Edge Insulatio
Closet
4 ft
0
20 ft2
—
1
0
0
5 Slab -On -Grade Edge Insulatio
AH
1 It
0
16 ft2
1
0
0
6 Slab -On -Grade Edge Insulatio
Hall
t It
0
58 ft'
—
1
0
0
7Slab-On-Grade Edge Insulatio
Bedroom 2
33 ft
0
156 ft2
—
1
0
0
8 Slab -On -Grade Edge Insulatio
Family Room
17 ft
0
391 ft2
—
1
0
0
9 Slab -On -Grade Edge Insulatio
Living Room
9 ft
0
115 ft2
—
1
0
0
10SIab-On-Grade Edge Insulatio
Foyer
7 ft
0
82 ft2
_
1
0
0
11SIab-On-Grade Edge Insulatio
Dining Room
11 It
0
130 ft2
_-
1
0
0
12SIab-On-Grade Edge Insulatio
Nook
loft
0
60 ft2
1
0
0
13Slab-On-Grade Edge Insulatio
Kitchen
1 It
0
158 ft2
—
1
0
0
14SIab-On-Grade Edge Insulatio
Master Bedroom
38 It
0
234 ft2
--
1
0
0
15SIab-On-Grade Edge Insulatio
WIC 1
6 ft
0
34 ft2
___
1
0
0
16SIab-On-Grade Edge Insulatio
Master Bathroom
5 ft
0
99 ft2
_—_
1
0
0
17SIab-On-Grade Edge Insulatio
WIC 2
6 ft
0
34 ft'
____
1
0
0
18SIab-On-Grade Edge Insulatio
Linen
1 ft
0
20 ft2
____
1
0
0
19SIab-On-Grade Edge Insulatio
Utility
1 It
0
84 ft2
____
1
0
0
20SIab-On-Grade Edge Insulatio
Hall 1
1 ft
0
35 ft2
__
1
0
0
21SIab-On-Grade Edge Insulatio
Pantry
1 ft
0
12 ft2
___
1
0
0
ROOF
/
Roof
Gable
Roof
Red
Solar SA Emitt
Emitt
Deck
Pitch
V # Type Materials Area
Area
Color
Barr
Absor. Tested
Tested
Insul.
(deg)
1 Hip Composition shingles 2406 ft2
0 ft2
Medium
N
0.6 No 0.9
No
0
26.6
ATTIC
/
V # Type
Ventilation
Vent Ratio (1
in)
Area
RBS IRCC
1 Full attic
Vented
150
2151 ft2
N N
10/28/2019 9:59 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Vented) Sunroom/Bedroo
30
Batt
164 ft'
0.1
Wood
2
Under Attic (Vented) Bedroom 3
30
Batt
174 ft'
0.1
Wood
3
Under Attic (Vented) Bath
30
Batt
75 ft'
0.1
Wood
4
Under Attic (Vented) Closet
30
Batt
20 ft'
0.1
Wood
5
Under Attic (Vented) AH
30
Batt
16 ft'
0.1
Wood
6
Under Attic (Vented) Hall
30
Batt
58 ft'
0.1
Wood
7
Under Attic (Vented) Bedroom 2
30
Batt
156 ft'
0.1
Wood
8
Under Attic (Vented) Family Room
30
Batt
391112
0.1
Wood
9
Under Attic (Vented) Living Room
30
Batt
115 ft'
0.1
Wood
10
Under Attic (Vented) Foyer
30
Batt
82 ft'
0.1
Wood
11
Under Attic (Vented) Dining Room
30
Batt
130 ft'
0.1
Wood
12
Under Attic (Vented) Nook
30
Batt
60 ft'
0.1
Wood
13
Under Attic (Vented) Kitchen
30
Batt
158 ft'
0.1
Wood
14
Under Attic(Vented) Master Bedroom
30
Batt
234 ft'
0.1
Wood
15
Under Attic (Vented) WIC 1
30
Batt
34 ft'
0.1
Wood
16
Under Attic (Vented) Master Bathroom
30
Batt
99 ft'
0.1
Wood
17
Under Attic (Vented) WIC 2
30
Batt
34 ft'
0.1
Wood
18
Under Attic (Vented) Linen
30
Batt
20 ft'
0.1
Wood
19
Under Attic (Vented) Utility
30
Batt
84 W
0.1
Wood
20
Under Attic (Vented) Hall 1
30
Batt
35 ft'
0.1
Wood
21
Under Attic (Vented) Pantry
30
Batt
12 ft'
0.1
Wood
WALLS
Adjacent S ace
P
Cavity
Width
Height
Sheathing Framing Solar
Below
o
1
NE
Exterior Concrete Block - Ext In9dnroom/Bed
4.1
13
0 8
0
104.0 ft'
0
0
0.6
0
2
SE
Exterior Concrete Block -Ext InWnroom/Bed
4.1
7
0 8
0
56.0 ft'
0
0
0.6
0
_ 3
NW
Exterior Concrete Block- Ext InSdnroom/Bed
4.1
14
0 8
0
112.0 ft'
0
0
0.6
0
4
NW
Exterior Concrete Block- Ext Inst9edroom 3
4.1
12
0 8
0
96.0 ft'
0
0
0.6
0
5
NW
Exterior Concrete Block- ExtInsul Bath
4.1
9
0 8
0
72.0 ft'
0
0
0.6
0
6
NW
Exterior Concrete Block - Ext Insul Closet
4.1
4
0 8
0
32.0 ft'
0
0
0.6
0
7
SE
Exterior Concrete Block - Ext InstBedroom 2
4.1
8
0 8
0
64.0 ft'
0
0
0.6
0
8
SW
Exterior Concrete Block - Ext InsrBedroom 2
4.1
13
0 8
0
104.0 ft'
0
0
0.6
0
9
NW
Exterior Concrete Block - Ext InsrBedroom 2
4.1
12
0 8
0
96.0 ft'
0
0
0.6
0
10
NE
Exterior Concrete Block - Ext IngAmily Room
4.1
17
0 10
0
170.0 ft'
0
0
0.6
0
11
SW
Exterior Concrete Block- Ext Inslutring Room
4.1
9
0 10
0
90.0 ft'
0
0
0.6
0
12
SE
Exterior Concrete Block- Ext Insul Foyer
4.1
1
0 10
0
10.0 ft'
0
0
0.6
0
13
SW
Exterior Concrete Block- Ext Insul Foyer
4.1
6
0 10
0
60.0 ft'
0
0
0.6
0
14
SW
Exterior Concrete Block- Ext InsDIning Room
4.1
11
0 10
0
110.0 ft'
0
0
0.6
0
15
NE
Exterior Concrete Block - Ext Insul Nook
4.1
10
0 8
0
80.0 ft'
0
0
0.6
0
16
NE
Exterior Concrete Block - Ext InSdhster Bedro
4.1
18
0 10
0
180.0 ft'
0
0
0.6
0
17
SE
Exterior Concrete Block - Ext InSdhster Bedro
4.1
13
0 10
0
130.0 ft'
0
0
0.6
0
_ 18
NW
Exterior Concrete Block - Ext Inddhster Bedro
4.1
7
0 10
0
70.0 ft'
0
0
0.6
0
19
SE
Exterior Concrete Block - Ext Insul WIC 1
4.1
6
0 8
0
48.0 ft'
0
0
0.6
0
10/28/2019 9:59 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Space
Cavity Width
Height
Sheathing Framing Solar Below
20
SE
Exterior
Concrete Block - Ext InLUster Bathro
4.1 5
0
8 0
40.0 ft'
0
0 0.6
0
21
SE
Exterior
Concrete
Block - Ext Insul WIC 2
4.1 6
0
8 0
48.0 ft'
0
0 0.6
0
22
N
Garage
Frame - Wood
Dining Room
11 12
10
120.0 ft'
0
0.23 0.600000 0
23
N
Garage
Frame - Wood
Pantry
11 1
10
10.0 ft'
0
0.23 0.600000 0
24
N
Garage
Frame - Wood
Utility
11 7
8
55.0 ft'
0
0.23 0.600000 0
25
N
Garage
Frame - Wood
Linen
11 5
8
40.0 ft'
0
0.23 0.600000 0
26
N
Garage
Frame - Wood
WIC 2
11 6
8
48.0 W
0
0.23 0.600000 0
DOORS
#
Ornt
Door Type
Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
_
1
SE
Wood
Sunroom/Bed
None
.39
2
10
6 10
19.4 ft'
2
NE
Wood
Family Room
None
.39
2
10
6 10
19.3 ft'
3
SW
Wood
Foyer
None
.39
3
6 10
20.4 ft'
4
NW
Wood
Master Bedro
None
.39
2
10
6 10
19.4 ft'
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V
#
Ornt ID
Frame
Panes
NFRC U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
NE 1
Vinyl
Low-E Single
Yes
0.33 0.23
N
30.0 ft'
2 ft 0 in
0 It 7 in
None
None
2
NW 4
Vinyl
Low-E Single
Yes
0.33 0.23
N
15.0 ft'
2 ft 0 in
0 ft 7 in
None
None
3
NW 5
Vinyl
Low-E Single
Yes
0.33 0.23
N
9.0 ft'
2 ft 0 in
0 ft 7 in
None
None
4
SW 8
Vinyl
Low-E Single
Yes
0.33 0.21
N
15.0 ft'
2It 0 in
0 ft 7 in
None
None
5
NE 10
Vinyl
Low-E Single
Yes
0.33 0.23
N
45.0 ft'
7 ft 0 in
0 ft 7 in
None
None
6
SW 11
Vinyl
Low-E Single
Yes
0.33 0.23
N
7.0 ft'
2 ft 0 in
0 ft 7 in
None
None
7
SW 11
Vinyl
Low-E Single
Yes
0.33 0.21
N
30.0 ft'
2 ft 0 in
0 ft 7 in
None
None
8
SW 13
Vinyl
Low-E Single
Yes
0.33 0.23
N
5.8 ft'
2 ft 0 in
0 ft 7 in
None
None
9
SW 13
Vinyl
Low-E Single
Yes
0.33 0.23
N
13.7 ft'
2 ft 0 in
0 ft 7 in
None
None
10
SW 14
Vinyl
Low-E Single
Yes
0.33 0.23
N
7.0 ft'
2 ft 0 in
0 ft 7 in
None
None
11
SW 14
Vinyl
Low-E Single
Yes
0.33 0.21
N
30.0 ft'
2 ft 0 in
0 ft 7 in
None
None
12
NE 15
Vinyl
Low-E Single
Yes
0.33 0.23
N
30.0 ft'
7 ft 0 in
0 ft 7 in
None
None
13
NE 16
Vinyl
Low-E Single
Yes
0.33 0.23
N
30.0 ft'
2 ft 0 in
0 ft 7 in
None
None
GARAGE
#
Floor Area
Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
380 ft'
380 ft'
31 ft
Sit
11
10/28/2019 9:59 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000402
2266.6 124.43 234.02 .1461
7
HEATING SYSTEM
# System Type
Subtype
Efficiency Capacity
Block
Ducts
1 Electric Heat Pump/
Split
HSPF:8.2 42 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unit/
Split
SEER: 14.5 40 kBtu/hr 1200 cfm
0.7 1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use SetPnt
Conservation
1 Electric None
Garage
0.95 50 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft'
DUCTS
— Supply —
V # Location R-Value Area
---- Return — Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT
ON RLF
HVAC #
Heat Cool
1 Attic 6 115 ft'
AH
20 ft' Default Leakage AH (Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y [[X�]Mar
HeFebJan Feb [X] Mar
Ceiling Fans: r ay4 [ [X] [X]
Apr May 4X� Jun ri Jul r ] Aug [ ] Sep
l 1 Jun 1 Jul (1 Aug [ 1 Sep
E
Oct [ Nov
Dec
rI)C')
[ ] Dec
10/28/2019 9:59 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
Therrpostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
fib
fib
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
Sunroom/Bedroom
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bedroom 3
Default(8 lbs/sq.ft.
ft'
ft
0.3
Bath
Default(8 lbs/sq.ft.
ft2
ft
0.3
Closet
Default(8 lbs/sq.ft.
ft'
ft
0.3
AH
Default(8 lbs/sq.ft.
ft2
ft
0.3
Hall
Defaull(8lbs/sq.ft.
ft2
ft
0.3
Bedroom 2
Default(8lbs/sq.ft.
ft2
ft
0.3
Family Room
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Living Room
Default(8 lbs/sq.ft.
ft2
ft
0.3
Foyer
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Dining Room
Default(8 lbs/sq.ft.
ft2
ft
0.3
Nook
Default(8 lbs/sq.ft.
ft2
ft
0.3
Kitchen
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Master Bedroom
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC 1
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Master
Bathroom
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC 2
Default(8lbs/sq.ft.
ft2
ft
0.3
Linen
Default(8lbs/sq.ft.
ft2
ft
0.3
Utility
Default(8 lbs/sq.ft.
ft2
ft
0.3
Hall
Default(8 lbs/s .ft.
ft2
ft
0.3
Pantry
10/28/2019 9:59 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Adams Homes - 2169 Model -8301 Cristelle cour Builder Name: Adams Homes
Street: 8301 Cristelle Court Permit Office: St. Lucie County
City, State, Zip: Ft. Pierce , FL, 34951 Permit Number.
id
Owner: Adams Homes -2169 Model Jurisdiction:
U
w
Design Location: FL, Fort Pierce
xO
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barriershall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks orjoints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in an dropped ceiling/soffit
y 9 /soffit
the insulation and any gaps in the air barrier shall be sealed.
ai
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
as.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exteriorwalls, or insulation that on
installation readily conforms to available space shall
extend behind ploing and wiring,
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exteror walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire snrinkler cover plates and walls or ceilings.
a. in addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
10/28/2019 10:00 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 91
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
AH
3. No, of units (if multiple -family)
3. 1
4. Number of bedrooms
4. 4
13. Cooling system: Capacity
40.0
a) Split system SEER
14.5
5. Is this a worst case? (yes/no)
5. No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6. 2151
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a. 0.330
b) Solar Heat Gain Coefficient (SHGC)
7b. 0.224
14. Heafing system: Capacity
42.0
c) Area
7c. 267.5
a) Split system heat pump HSPF
8.2
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a. NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b. NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a. 0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.95
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2. 4.1
0 Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10B1. 11.0
2. Masonry (Insulation R-value)
10B2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
Yes
a) Under attic
11a. 30.0
b) Cross ventilation
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11d. No
e) Multizone heating credit
f) Programmable thermostat
Yes
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy
Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed
code compliant features.
Builder Signatur
p
Date:T�/i/
Address of New Home: 8301 Cristelle Court
City/FL Zip: Ft. Pierce, FL 34951
10/28/2019 10:00:16 AM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: ADAMS HOMES- 1635 MODEL Builder Name: ADAMS HOMES
Street: 5404 LUGO STREET Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, Permit Number:
Y
Owner. Jurisdiction: ST LUCIE COUNTY
w
Design Location: FL, Fort Pierce
=
O
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation in any dropped ceiling/soffit
insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
Thejunction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
Thejunction of the top plate and the top of exterior walls shall be sealed.
shall be insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of insulation.
Floor framing cavity insulation shall be installed to
(including
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation shall
and cantilevered floors)
be permitted to be in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottorr
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the drywall.
thermal envelope shall be air fight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring a
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs.
insulated.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended bythe manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover plates and walls or Ceilings.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
10/25/2019 1:14 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1