Loading...
HomeMy WebLinkAboutSoil Compaction ReportHeadquarters �' 7 C 1 t ENGINEE G I I/%i'v�lO-1377 11345 U.S. Highway 1 PO Box 78-1377 Sebastian, FL. 32958 &J AVL AND TES G FL. 78 Orlando Phone: 772 589-0Sebastian, 712 723 Progress Way SOIL COMPACTION REPORT C.A.# 5693 Sanford, FL. 32771 KSMengineering.net ASTM D 3557 and ASTM D 2922 DATE TESTED: January 17, 2020 KSM JOB M 200286-id/MJ/jo PERMIT #: 19i3s035 CONTRACTOR: Adams Homes JOB LOCATION: 8301 Cristelle Court Lot 1, Waterstone Fort Pierce, Florida ITEM TESTED: Compacted Foundation Fill TEST LOCATION PEN DRY MAX. DRY PERCENT OF SAMPLE DEPTH READ DENSITY PROCTOR VALUE (P.C.F) COMPACTION 1. S.E. 0" -12" 65 115.6 116.1 99.6% 2. S.W. 55 113.8 98.0% 3. Center 54 114.2 98.4% 4. N.E. 52 112.7 97.1% 5. N.W. 53 113.8 98.0% 118.0 - W I E i Soil Description: Brown Clayed Sand with I G Ii I I I ' 117.0 • • — • — _ _ _— — I — I I I I I Traces of Shell H I I In Place Moisture: T I I I I I 116.0 j—..—.�—..— I.—. J..—..1..—... 3.1% P I I I Optimum Moisture:I11.0% \-4 115.0—.. .l.—..-1.—Max. Dry Density: P.C.F. F 116.1 I I I I D 114.0..—.I—..-1.—..—�.—..y..—..t..—... @ Test Locations The Density & Penetrometer R Y I I I I I I I I I I Readings Indicate the 113.0 ••—•i—••—;•—••—i•-••�••—••T •—••, Degree of Compaction Meets 8 9 10 11 12 13 14 Minimum Required for Stakelgl,?H datio Moisture - % of Dry Weight Disclaimer: Contractor is responsible to maintain '°. the tested area in the condition that KSM No. 439 completed the indicated passed compaction test. KSM is not responsible if the tested area has been STATE OF ��`ah altered from the approved inspected condition. P�4/$ 's�%%% 1/20/2020 Email to: St Lucie Building Department; rjohnson@adamshomes.com; ceo2459@gmail.com Proudly Serving Florida since 1990