Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 r FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 118 Block 5 Waterstone 1780 AGR Builder Name: ADAMS HOME Kt(rEl t Street:5334 San Bendelto Place Permit Office: City, State, Zip: Fort Pierce, FL34983 Owner: Permit Number: 1 1, DEC 7 2Q�9 Jurisdiction: 661000 Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Flori a&1IrrrakjEo 9L?n1 y Permitting 1. New construction or existing New (From Plans) 9. Wall Types(1512.6 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1244.60 ft' 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=13.0 268.OD ft' 4. Number of Bedrooms 3 c. NIA d. N/A R= ft' 5. Is this a worst case? No 10. Ceiling Types (1780.0 sgft.) R= ft' Insulation Area 6. Conditioned floor area above grade (W) 1780 a. Under Attic (Vented) b. NIA R=30.0 1780.00 ft' R= ii Conditioned floor area below grade (ft') 0 c. N/A R= ft. 7. Windows(177.4 sgft.) Description Area 11. Ducts Sup: Attic, Rat: Main, AH: Main R ft' a. U-Factor. Dial, U=0.35 113.31 It -a. 6 356 SHGC: SHGC=0.29 b. U-Factor: Dbl, U=0.35 46.31 W 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.26 a. Central Unit 28.4 SEER:15.00 c. U-Factor: Dbl, U=0.55 17.78 ft' SHGC: SHGC=0.29 d. U-Factor: N/A 13. Heating systems kBlu/hr Efficient ft' SHGC: a. Electric Heat Pumpy 28.2 HSPF:8.50 Area Weighted Average Overhang Depth: 2.402 ft. Area Weighted Average SHGC: 0.282 14. Hot water systems 8. Floor Types (1780.0 sqft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1780.00 ft' EF: 0.940 b. N/A R ft' b. Conservation features c. NIA R= ft, None 15. Credits Pstat Glass/Floor Area: 0.100 Total Proposed Modified Loads: 56.03 PASS Total Baseline Loads: 56.19 I hereby certify that the plans and this calculation are in compliances Code. f PREPARED BY: __ f DATE: 82=1.9-ull1na-Keomany 3tions covered by Florida Enessv-- I hereby certify that this building, as designed, is in compliance with the Florida Enerav Code. DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: DATE: ­ ••r­••u_ luqurrca ouruncauon oy me air nanmer unit manufacturer that the air handler enclosure qualifies as certed factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). S1' 2��9 P� 4t co 8/2/2019 2:14 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software. Page 1 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Lot 118 Block 5 Walerslone 1 Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1780 Lot # 118 Owner Name: Total Stories: 1 Block/Subdivision: Waterstone # of Units: 1 Worst Case: No PlatBook: Builder Name: ADAMS HOMES Rotate Angle: 0 Street: 5334 San Bendetto Pla Permit Office. Cross Ventilation: No County: St. Lucie Jurisdiction: 661000 Whole House Fan: No City, Stale, Zip: Fort Pierce Family Type: Single-family , New/Existing: New (From Plans) FL, 34963 Comment: CLIMATE ` / v Design Location Design Temp Int Design Temp Heating Design Daily Temp TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Blockl 1780 15664 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Healed 1 Main 1780 15664 Yes 6 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpel 1 Slab -On -Grade Edge Insulatio Main 155.7 It 0 1780 ft' 0.38 0 0.62 ROOF V Roof Gable Roof Red Solar SA Emitt Emitl Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 1991 ft' 446 ft' Medium N 0.85 N 0.85 No 0 26.6 ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1780 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Free Truss Type 1 Under Attic (Vented) Main 30 Blown 1780W 0.11 Wood 8/2/2019 2:14 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS it Ornt Adjacent Tn Wall Tye Space Cavity Width R 1r Et t Ft Height I Sheathing Framing lar Solar Below n 1 BE Exterior Concrete Block - Int Insul Main 4.1 40 0 8 0 Aea 320.0 R V lue.�r cti 4h (: re o ft' 0 0 0.6 0 2 SW Exterior Concrete Block - Int Insul Main 4..1 40 6 8 0 324.0 it- 0 0 0.6 0 3 W Exterior Concrete Block - Int Insul Main 4.1 3 0 9 6 28.5 W 0 0 0.6 4 NW Exterior Concrete Block - Int Insul Main 4.1 11 9 9 6 111.6 ft' 0 0 0.6 0 5 N Exterior Concrete Block - Int Insul Main 4.1 3 0 9 6 28.5 ft' 0 0 0.6 0 0 6 NE Exterior Concrete Block - Int Insul Main 4.1 54 0 8 0 432.0 W 0 0 0.6 0 7 - Garage Frame - Wood Main 13 33 6 8 0 268.0 ft' 0 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 NW Insulated Main None .25 3 6 8 20 ft' 2 - Wood Main None .25 2 8 6 8 17.8 W WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 SE 1 Vinyl Low-E Double Yes 0.55 0.29 N 17.8 ft2 12 ft 0 in 0 It 10 in None None 2 BE 1 Vinyl Low-E Double Yes 0.35 0.29 N 32.4 ft' 1 It 4 in 0 It 10 in Drapes/blinds Exterior 5 3 SW 2 Vinyl Low-E Double Yes 0.35 0.29 N 32.4 ft' 1 It 4 in 0 It 10 in Drapes blinds Exterior 5 4 W 3 Vinyl Low-E Double Yes 0.35 0.26 N 11.4 ft' 1 it 4 in 0 It 10 in Drapes/blinds Exterior 5 5 NW 4 Vinyl Low-E Double Yes 0.35 0.26 N 23.6 ft' 1 It 4 in 0 It 10 In Drapes/blinds Exteriors 6 N 5 Vinyl Low-E Double Yes 0.35 0.26 N 11.4 ft' 1 It 4 in 0 It 10 in Drapes/blinds Exterior 5 7 NE 6 Vinyl Low-E Double Yes 0.35 0.29 N 48.6 ft' 1 ft 4 in 0 It 10 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 391 ft' 391 ft' 64 It 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ElA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000391 1827.5 100.33 188.68 .1409 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 28.2 kBtu/hr -EE 1 sys#1 8/2/2019 2:14 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FARM R405-2017 W01IT cI InnnnAOV ruorvr 1�T .,r .,....� — v..�a.r�u.7 r rt�rvrt I COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/Split SEER: 15 28.4 kBtulhr 947 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name System Model # Collector Model Collector # Area Storage Volume FEF None None ft, DUCTS / --Supply--- V —Return — Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 356 ft' Main 89 ft- Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programablre'Thermostat: C[reiling Fans: ,]Y eb Heating l l Jan l l Feb Venting I 1 Jan I 1 Feb r , [Xj Mar IXl Mar Apr [ ] lX May lXl Ma Jun IXl Jul [ Aug Jun Jul Aug r[[ ]J [ ] Sep L 1 Oct Oct Nov H Dec Dec lI 11 I I Sep lXlNov lXl X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 g 10 11 12 Cooling(WD) AM PM 78 80 78 78 80 78 78 78 78 78 78 78 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM PM 66 68 66 66 68 68 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM PM 66 68 66 66 68 68 66 fib 68 68 68 68 66 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft- 0 ft 0.3 Main 8/2/2019 2:14 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 _. 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 3. No. of units (if multiple -family) 3. 1 c) AHU location Main 4. Number of bedrooms q, 3 5. Is this a worst case? (yes/no) 5. No 6. Conditioned floor area (sq. ft.) 6. 1780 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.370 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.282 c) Area 7c. 177.4 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. c) Concrete, raised (R-value) gc, 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 10A7. 10A2. 4.1 10B1. 13.0 10B2. 13. Cooling system: Capacity 28.4 a) Split system SEER 15.0 b) Single package SEER c) Ground/water source SEER/COP d) Room unit/PTAC EER e) Other 14. Heating system: Capacity 28.2 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF c) Electric resistance COP d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 15. Water heating system a) Electric resistance EF 0.94 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF_ f) Heat recovery unit HeatRec% g) Other 16. HVAC credits claimed (Performance Method) a) Ceiling fans 1 la. 30.0 b) Cross ventilation No 11b. c) Whole house fan No 1 1 c. d) Multizone cooling credit 11d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signatur /) /a 9 Date: Address of New Home: 5334 San Bendelto Place City/FL Zip: Fort Pierce FL 34983 8/2/2019 2:14:14 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1