HomeMy WebLinkAboutEnergy CodeFORM R405-2017
r
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 118 Block 5 Waterstone 1780 AGR
Builder Name: ADAMS HOME Kt(rEl t
Street:5334 San Bendelto Place
Permit Office:
City, State, Zip: Fort Pierce, FL34983
Owner:
Permit Number:
1
1,
DEC 7 2Q�9
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Flori a&1IrrrakjEo 9L?n1 y Permitting
1. New construction or existing New (From Plans)
9. Wall Types(1512.6 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1244.60 ft'
3. Number of units, if multiple family 1
b. Frame - Wood, Adjacent
R=13.0 268.OD ft'
4. Number of Bedrooms 3
c. NIA
d. N/A
R= ft'
5. Is this a worst case? No
10. Ceiling Types (1780.0 sgft.)
R= ft'
Insulation Area
6. Conditioned floor area above grade (W) 1780
a. Under Attic (Vented)
b. NIA
R=30.0 1780.00 ft'
R= ii
Conditioned floor area below grade (ft') 0
c. N/A
R= ft.
7. Windows(177.4 sgft.) Description Area
11. Ducts
Sup: Attic, Rat: Main, AH: Main
R ft'
a. U-Factor. Dial, U=0.35 113.31 It -a.
6 356
SHGC: SHGC=0.29
b. U-Factor: Dbl, U=0.35 46.31 W
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.26
a. Central Unit
28.4 SEER:15.00
c. U-Factor: Dbl, U=0.55 17.78 ft'
SHGC: SHGC=0.29
d. U-Factor: N/A
13. Heating systems
kBlu/hr Efficient
ft'
SHGC:
a. Electric Heat Pumpy
28.2 HSPF:8.50
Area Weighted Average Overhang Depth: 2.402 ft.
Area Weighted Average SHGC: 0.282
14. Hot water systems
8. Floor Types (1780.0 sqft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1780.00 ft'
EF: 0.940
b. N/A R ft'
b. Conservation features
c. NIA R= ft,
None
15. Credits
Pstat
Glass/Floor Area: 0.100 Total Proposed Modified
Loads: 56.03
PASS
Total Baseline
Loads: 56.19
I hereby certify that the plans and
this calculation are in compliances
Code. f
PREPARED BY: __ f
DATE: 82=1.9-ull1na-Keomany
3tions covered by
Florida Enessv--
I hereby certify that this building, as designed, is in compliance
with the Florida Enerav Code.
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
BUILDING OFFICIAL:
DATE:
••r••u_ luqurrca ouruncauon oy me air nanmer unit manufacturer that the air handler enclosure qualifies as
certed factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
S1' 2��9 P�
4t co
8/2/2019 2:14 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software. Page 1 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Lot 118 Block 5 Walerslone 1 Bedrooms: 3
Address Type:
Street Address
Building Type:
User
Conditioned Area: 1780
Lot #
118
Owner Name:
Total Stories: 1
Block/Subdivision:
Waterstone
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
ADAMS HOMES
Rotate Angle: 0
Street:
5334 San Bendetto Pla
Permit Office.
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
661000
Whole House Fan: No
City, Stale, Zip:
Fort Pierce
Family Type:
Single-family
,
New/Existing:
New (From Plans)
FL, 34963
Comment:
CLIMATE
` /
v Design
Location
Design Temp
Int Design Temp Heating
Design Daily Temp
TMY Site 97.5 % 2.5 %
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75
299
58 Medium
BLOCKS
Number
Name
Area Volume
1
Blockl
1780 15664
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms Infil ID Finished Cooled Healed
1
Main
1780 15664 Yes 6
3 1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpel
1 Slab -On -Grade Edge Insulatio Main 155.7 It 0
1780 ft'
0.38
0 0.62
ROOF
V
Roof Gable Roof
Red Solar SA Emitt
Emitl Deck Pitch
#
Type
Materials Area Area Color
Barr Absor. Tested
Tested Insul. (deg)
1
Gable or Shed Composition shingles 1991 ft' 446 ft' Medium
N 0.85 N 0.85
No 0 26.6
ATTIC
#
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 1780
ft' N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Free Truss Type
1
Under Attic (Vented)
Main 30 Blown
1780W 0.11
Wood
8/2/2019 2:14 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
it Ornt Adjacent
Tn Wall Tye
Space
Cavity Width
R 1r Et t Ft
Height
I
Sheathing Framing lar
Solar Below
n
1 BE Exterior Concrete Block - Int Insul
Main
4.1 40 0 8
0
Aea
320.0
R V lue.�r
cti 4h
(: re o
ft'
0
0 0.6
0
2 SW Exterior Concrete Block - Int Insul
Main
4..1 40 6 8
0
324.0 it-
0
0 0.6
0
3 W Exterior Concrete Block - Int Insul
Main
4.1 3 0 9
6
28.5 W
0
0 0.6
4 NW Exterior Concrete Block - Int Insul
Main
4.1 11 9 9
6
111.6 ft'
0
0 0.6
0
5 N Exterior Concrete Block - Int Insul
Main
4.1 3 0 9
6
28.5 ft'
0
0 0.6
0
0
6 NE Exterior Concrete Block - Int Insul
Main
4.1 54 0 8
0
432.0
W
0
0 0.6
0
7 - Garage Frame - Wood
Main
13 33 6 8
0
268.0 ft'
0
0.23 0.01
0
DOORS
# Ornt Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1 NW Insulated Main
None
.25
3
6 8
20 ft'
2 - Wood Main
None
.25
2
8
6 8
17.8 W
WINDOWS
Orientation shown is the entered, Proposed orientation.
/ Wall
Overhang
V # Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Area
Depth
Separation
Int Shade
Screening
1 SE 1 Vinyl Low-E Double
Yes
0.55 0.29 N
17.8 ft2
12 ft 0 in
0 It 10 in
None
None
2 BE 1 Vinyl Low-E Double
Yes
0.35 0.29 N
32.4 ft'
1 It 4 in
0 It 10 in
Drapes/blinds
Exterior 5
3 SW 2 Vinyl Low-E Double
Yes
0.35 0.29 N
32.4 ft'
1 It 4 in
0 It 10 in
Drapes blinds
Exterior 5
4 W 3 Vinyl Low-E Double
Yes
0.35 0.26 N
11.4 ft'
1 it 4 in
0 It 10 in
Drapes/blinds
Exterior 5
5 NW 4 Vinyl Low-E Double
Yes
0.35 0.26 N
23.6 ft'
1 It 4 in
0 It 10 In
Drapes/blinds
Exteriors
6 N 5 Vinyl Low-E Double
Yes
0.35 0.26 N
11.4 ft'
1 It 4 in
0 It 10 in
Drapes/blinds
Exterior 5
7 NE 6 Vinyl Low-E Double
Yes
0.35 0.29 N
48.6 ft'
1 ft 4 in
0 It 10 in
Drapes/blinds
Exterior 5
GARAGE
# Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 391 ft' 391 ft'
64 It
8 ft
1
INFILTRATION
# Scope Method SLA
CFM 50 ElA EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000391
1827.5 100.33 188.68
.1409
7
HEATING SYSTEM
# System Type Subtype
Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/ Split
HSPF:8.5
28.2 kBtu/hr
-EE
1
sys#1
8/2/2019 2:14 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4
FARM R405-2017 W01IT cI InnnnAOV ruorvr 1�T .,r .,....�
— v..�a.r�u.7 r rt�rvrt I
COOLING SYSTEM
# System Type
Subtype
Efficiency Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/Split
SEER: 15 28.4 kBtulhr
947 cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap Use
SetPnt
Conservation
1 Electric
None
Garage
0.94 40 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
System Model # Collector Model
Collector
# Area
Storage
Volume
FEF
None None
ft,
DUCTS
/ --Supply---
V
—Return — Air
CFM 25 CFM25
HVAC#
# Location R-Value Area
Location
Area Leakage Type Handler
TOT OUT
ON
RLF
Heat Cool
1 Attic
6 356 ft'
Main
89 ft- Default Leakage Main
(Default) (Default)
1 1
TEMPERATURES
Programablre'Thermostat:
C[reiling Fans:
,]Y eb
Heating l l Jan l l Feb
Venting I 1 Jan I 1 Feb
r ,
[Xj Mar
IXl Mar
Apr [
] lX
May lXl Ma Jun IXl Jul [ Aug
Jun Jul Aug
r[[ ]J [ ]
Sep L 1
Oct Oct
Nov
H Dec
Dec
lI 11 I
I Sep lXlNov
lXl
X Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6 7
8 g
10
11
12
Cooling(WD) AM
PM
78
80
78 78
80 78
78 78 78 78
78
78 80
80
80
80
78 78 78
78 78
78
78
78
Cooling (WEH) AM
PM
78
78
78 78
78 78
78 78 78 78
78
78 78
78
78
78
78 78 78
78 78
78
78
78
Heating (WD) AM
PM
66
68
66 66
68 68
66 66 68 68
68
68 68
68
68
68
68 68 68
68 68
68
66
66
Heating (WEH) AM
PM
66
68
66 66
68 68
66 fib 68 68
68 68
66 68
68
68
68
68 68
68 68
68
66
66
MASS
Mass Type
Area
Thickness Furniture Fraction Space
Default 8 Ibs/s .ft.
0 ft-
0 ft 0.3
Main
8/2/2019 2:14 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4
_. 2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level
a) Supply ducts R 6.0
2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0
3. No. of units (if multiple -family) 3. 1 c) AHU location Main
4. Number of bedrooms
q,
3
5. Is this a worst case? (yes/no)
5.
No
6. Conditioned floor area (sq. ft.)
6.
1780
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.370
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.282
c) Area
7c.
177.4
8. Skylights
a) U-factor:(weighted average)
8a.
NA
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
c) Concrete, raised (R-value)
gc,
10. Wall type and insulation:
A. Exterior:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
10A7.
10A2. 4.1
10B1. 13.0
10B2.
13. Cooling system:
Capacity 28.4
a) Split system
SEER 15.0
b) Single package
SEER
c) Ground/water source
SEER/COP
d) Room unit/PTAC
EER
e) Other
14. Heating system:
Capacity 28.2
a) Split system heat pump
HSPF 8.5
b) Single package heat pump HSPF
c) Electric resistance
COP
d) Gas furnace, natural gas
AFUE
e) Gas furnace, LPG
AFUE
f) Other
15. Water heating system
a) Electric resistance EF 0.94
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF_
f) Heat recovery unit HeatRec%
g) Other
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
1 la. 30.0 b) Cross ventilation No
11b. c) Whole house fan
No
1 1 c.
d) Multizone cooling credit
11d. No e) Multizone heating credit
f) Programmable thermostat Yes
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signatur /) /a 9
Date:
Address of New Home: 5334 San Bendelto Place City/FL Zip: Fort Pierce FL 34983
8/2/2019 2:14:14 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1