Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FL"ORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: ADAMS HOMES- 1635 MODEL Builder Name: ADAMS HOMES RECEIVED _- Street: 5404 LUGO STREET Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: n 7 I Owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County. St. Lucie (Florida Cli a o eLuc2) ie euun� 1. New construction or existing New (From Plans) 9. Wall Types (1730.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1504.00 ft2 b. Frame- Wood, Adjacent R=11.0 226.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (1635.0 soft.) Insulation Area a. Under Attic (Vented) R=30.0 1635.00 ft2 6. Conditioned floor area above grade (ft2) 1635 b. N/A R= ft2 Conditioned floor area below grade (W) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(213.8 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: AHU CLST 6 140 a. U-Factor: Sgl, U=0.33 153.78 ft2 SHGC: SHGC=0.23 b. U-Factor: Sgl, U=0.33 60.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 29.0 SEER:15.00 c. U-Factor: N/A ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 27.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.224 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1635.0 sgft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 1635.00 ft' b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits None Glass/Floor Area: 0.131 Total Proposed Modified Loads: 55.26 PASS Total Baseline Loads: 61.09 1 hereby certify that the plans and specifications covered by Review of the plans and ST`trC� this calculation are in compliance with the Florida Energy specifications covered by this �4StiS Code. calculation indicates compliance n� i f eL �C91J with the Florida Energy Code. N rnir. _ , r PREPARED BY: Before construction is completed DATE: 10-28-19 this building will be inspected for compliance with Section 553.908 t9 l c I hereby certify that this building, as designed, is in compliance Florida Statutes.;. with the Florida En er Code. GOp WHO OWNER/AGE •l BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). DEC, a 1200 FILE COPY 10/25/2019 1:14 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT TiBe: ADAMS HOMES-1635 MODE Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 1635 Lot# Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: ADAMS HOMES Rotate Angle: 0 Street: 5404 LUGO STREET Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, Stale, Zip: FORT PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1635 15904 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 3 130 1300 No 0 1 1 Yes Yes Yes 2 BEDROOM4 124 1240 No 0 1 1 Yes Yes Yes 3 CLST 3 16 160 No 0 1 Yes Yes 'Yes 4 AHU CLST 9 90 No 0 1 No Yes Yes 5 WIC 4 14 140 No 0 1 No Yes Yes 6 BATH 3 45 450 No 0 1 Yes Yes Yes 7 CLST 2 18 180 No 0 1 Yes Yes Yes 8 BEDROOM 2 190 1900 No 0 1 1 Yes Yes Yes 9 HALL 71 710 No 0 1 No Yes Yes 10 KITCHEN 154 1540 Yes 0 1 No Yes Yes 11 LAUNDRY 42 336 No 0 1 No Yes Yes 12 CLST 12 96 No 0 1 No Yes Yes 13 FOYER 58 580 No 0 1 Yes Yes Yes 14 MWIC 42 336 No 0 1 Yes Yes Yes 15 M BATH 127 1016 No 0 1 Yes Yes Yes 16 MASTER BEDROO 200 2000 No 0 1 1 Yes Yes Yes 17 FAMILY/DINING 383 3830 No 0 1 Yes Yes Yes 10/25/2019 1:14 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation BEDROOM 3 23 ft 0 130 ft2 ---- 1 0 0 2 Slab -On -Grade Edge Insulation BEDROOM 4 10.9 ft 0 124 ft' ---- 1 0 0 3 Slab -On -Grade Edge Insulation CLST 3 2 It 0 16 ft2 ---- 1 0 0 4 Slab -On -Grade Edge Insulation AHU CLST 1 ft 0 9 ft' ---- 1 0 0 5 Slab -On -Grade Edge Insulation WIC 4 1 ft 0 14 ft2 ---- 1 0 0 6 Slab -On -Grade Edge Insulation BATH 3 5 ft 0 45 ft' ---- 1 0 0 7 Slab -On -Grade Edge Insulation CLST 2 2 ft 0 18 ft2 ---- 1 0 0 8 Slab -On -Grade Edge Insulation BEDROOM 2 14 fl 0 190 ft2 ---_ 1 0 0 9 Slab -On -Grade Edge Insulation HALL 1 ft 0 71 ft' ---- 1 0 0 10SIab-On-Grade Edge Insulation KITCHEN 1 ft 0 154 ft2 ---- 1 0 0 11SIab-On-Grade Edge Insulation LAUNDRY 1 ft 0 42 ft2 ---- 1 0 0 12SIab-On-Grade Edge Insulation CLST 1 ft 0 12 ft2 ---- 1 0 0 13SIab-On-Grade Edge Insulation FOYER 7 ft 0 58 ft2 ---- 1 0 0 14SIab-On-Grade Edge Insulation M W IC 6 ft 0 42 ft2 ---- 1 0 0 15SIab-On-Grade Edge Insulation M BATH 32 ft 0 127 ft2 ---- 1 0 0 16SIab-On-Grade Edge Insulation MASTER BEDRO 16 ft 0 200 ft' ---- 1 0 0 17SIab-On-Grade Edge Insulation FAMILYIDINING 40 ft 0 383 ft2 ---- 1 0 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emilt Deck Pitch V # Type Materials Area Area Color Barr Absoc Tested Tested Insul. (deg) 1 Hip Composition shingles 1829 ft' 0 ft2 Medium N 0.6 No 0.9 No 0 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 In) Area RBS IRCC 1 Full attic Vented 150 1635 ft2 N N 10/25/2019 1:14 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 130 it' 0.1 Wood 2 Under Attic (Vented) BEDROOM 4 30 Blown 124 ft2 0.1 Wood 3 Under Attic (Vented) CLST3 30 Blown 16 ft2 0.1 Wood 4 Under Attic (Vented) AHU CLST 30 Blown 9 ft2 0.1 Wood 5 Under Attic (Vented) WIC 4 30 Blown 14 ft2 0.1 Wood 6 Under Attic (Vented) BATH 3 30 Blown 45 ft2 0.1 Wood 7 Under Attic (Vented) CLST 2 30 Blown 18 ft2 0.1 Wood 8 Under Attic (Vented) BEDROOM 2 30 Blown 190 ft2 0.1 Wood 9 Under Attic (Vented) HALL 30 Blown 711112 0.1 Wood 10 Under Attic (Vented) KITCHEN 30 Blown 154 ft2 0.1 Wood 11 Under Attic (Vented) LAUNDRY 30 Blown 42 ft' 0.1 Wood 12 Under Attic (Vented) CLST 30 Blown 12 ft2 0.1 Wood 13 Under Attic (Vented) FOYER 30 Blown 58 ft2 0.1 Wood 14 Under Attic (Vented) MWIC 30 Blown 42 ft2 0.1 Wood 15 Under Attic (Vented) MBATH 30 Blown 127 ft2 0.1 Wood 16 Under Attic (Vented) MASTER BEDRO 30 Blown 200 fF 0.1 Wood 17 Under Attic (Vented) FAMILY/DINING 30 Blown 383 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 E Exterior Concrete Block - Ext InstSEDROOM 3 4.1 12 0 10 0 120.0 ft2 0 0 0.6 0 2 S Exterior Concrete Block - Ext Ins57EDROOM 3 4.1 11 0 10 0 110.0 ft2 0 0 0.6 0 3 S Exterior Concrete Block - Ext Inst9EDR00M 4 4.1 11 0 10 0 110.0 ft' 0 0 0.6 0 4 E Exterior Concrete Block - Ext Insul CLST 3 4.1 2 0 10 0 20.0 112 0 0 0.6 0 5 E Exterior Concrete Block - Ext Insul BATH 3 4.1 5 0 10 0 50.0 ft' 0 0 0.6 0 6 E Exterior Concrete Block - Ext Insul CLST 2 4.1 2 0 10 0 20.0 ft2 0 0 0.6 0 _ 7 E Exterior Concrete Block - Ext InsiBEDROOM 2 4.1 14 0 10 0 140.0 ft2 0 0 0.6 0 8 N Garage Frame- Wood BEDROOM 2 11 13 0 10 0 130.0 ft2 0 0.1 0.6 0 9 N Garage Frame - Wood LAUNDRY 11 7 0 8 0 56.0 ft2 0 0.1 0.6 0 10 N Exterior Concrete Block - Ext Insul FOYER 4.1 7 0 10 0 70.0 ft' 0 0 0.6 0 11 E Garage Frame - Wood FOYER 11 4 0 10 0 40.0 ft2 0 0.1 0.6 0 12 E Exterior Concrete Block - Ext Insul MWIC 4.1 6 0 8 0 48.0 if 0 0 0.6 0 13 W Exterior Concrete Block - Ext Insul M BATH 4.1 13 0 8 0 104.0 ft2 0 0 0.6 0 14 N Exterior Concrete Block - Ext Insul M BATH 4.1 13 0 8 0 104.0 ft2 0 0 0.6 0 _ 15 E Exterior Concrete Block - Ext Insul M BATH 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 16 W Exterior Concrete Block - Ext InsLMASTER BE 4.1 16 0 10 0 160.0 ft2 0 0 0.6 0 17 W Exterior Concrete Block- Ext InsLHAMILY/DINI 4.1 22 0 10 0 220.0 ft2 0 0 0.6 0 18 S Exterior Concrete Block -Ext lnsdfAMILY/DINI 4.1 18 0 10 0 180.0 if 0 0 0.6 0 10/25/2019 1:14 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WINDOWS ' Orientation shown is the entered, Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S 2 Vinyl Low-E Single Yes 0.33 0.23 N 15.0 ft' 2 ft 0 in 0 ft 7 in None None 2 S 3 Vinyl Low-E Single Yes 0.33 0.23 N 15.0 ft' 2 ft 0 in 0 ft 7 in None None 3 E 7 Vinyl Low-E Single Yes 0.33 0.21 N 15.0 ft' 2 It 0 in 0 ft 7 in None None 4 N 10 Vinyl Low-E Single Yes 0.33 0.23 N 6.7 ft' 2 ft 0 in 0 ft 7 in None None 5 N 10 Vinyl Low-E Single Yes 0.33 0.23 N 13.3 ft' 2 ft 0 in 0 ft 7 in None None 6 N 10 Vinyl Low-E Single Yes 0.33 0.23 N 20.0 ft' 2 ft 0 in 0 ft 7 in None None 7 W 13 Vinyl Low-E Single Yes 0.33 0.23 N 6.0 ft' 2 ft 0 in 0 ft 7 in None None 8 N 14 Viny1 Low-E Single Yes 0.33 0.21 N 15.0 ft' 2 ft 0 in 0 ft 7 in None None 9 W 16 Vinyl Low-E Single Yes 0.33 0.23 N 30.0 ft' 2 It 0 in 0 ft 7 in None None 10 W 17 Vinyl Low-E Single Yes 0.33 0.21 N 30.0 f' 2 ft 0 in 0 ft 7 in None None 11 S 18 Vinyl Low-E Single Yes 0.33 0.23 N 30.0 ft' 2 ft 0 in 0 ft 7 in None None 12 S 18 Vinyl Low-E Single Yes 0.33 0.23 N 17.8 ft' 2 ft 0 in 0 ft 7 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 400 ft' 400 ft' 24 ft 8 It 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000433 1855.5 101.86 191.57 .1621 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.2 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 29 kBtu/hr 870 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cent # Company Name System Model # Collector Model # Area Volume FEF None None ft' 10/25/2019 1:14 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DUCTS / ---- Supply---- ---- Return ---- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 140 ft2 Attic 14 ft2 Default Leakage AHU CLST (Default) c(Default) c 1 1 TEMPERATURES ProgramablerxThermostat: Ceiling Fans: [x]]JN Heating Jan Feb j[�X]]] Mar Apr Apr May May Jun [X] [ ] Jul fXI [ ] Aug [X] [ ] Sep rrrr Nov Dee € Venting I 1 Jan [ l l l 1 Feb l lxJ [Xl Mar Jun I 1 Jul [ 11 Aug I 1 Sep Oct [X Nov Deec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating(WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft2 0 ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 4 Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 3 Default(8 lbs/sq.ft. ft2 ft 0.3 AHU CLST Default(8 lbs/sq.ft. ft2 ft 0.3 WIC Default(8 lbs/sq.ft. ft2 ft 0.3 BATH 3 Default(8 lbs/sq.ft. ft2 ft 0.3 CLST 2 Default(8 lbs/sq.ft. ft2 it 0.3 BEDROOM2 Default(8 lbs/sq.ft. ft2 ft 0.3 HALL Default(8 lbs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8 lbs/sq.ft. ft2 ft 0.3 CLST Default(8 lbs/sq.ft. ft2 ft 0.3 FOYER Default(8 lbs/sq.ft. it, ft 0.3 MWIC Default(8 lbs/sq.ft. ft2 ft 0.3 M BATH Default(B lbs/sq.ft. ft2 ft 0.3 MASTER BEDROO Default(8 lbs/s.ft. ft2 ft 0.3 FAMILY/DINING 10/25/2019 1:14 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6 This document was created with Win2PDF available at http://www.win2pdf.com. The unregistered version of Win2PDF is for evaluation or non-commercial use only. This page will not be added after purchasing Win2PDF. 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 90 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location AHU CLST 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 29.0 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1635 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.330 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.224 14. Heating system: Capacity 27.0 c) Area 7c. 213.8 a) Split system heat pump HSPF 8.2 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) Be. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.98 b) Gas Fred, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 11.0 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 1la. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signat --• ' `� �� Date: O/�151 Address of New Home: 5404 LUGO STREET City/FL Zip: FORT PIERCE. FL 10/25/2019 1:14:36 PM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: ST LUCIE COUNTY Permit #: Job,lnformation Builder: ADAMS HOMES Community: Lot: NA Address: 5404 LUGO STREET City: FORT PIERCE State: FL Zip: Air Leakage Test Results Passing results must meet either the Performance, Prescriptive, or ERI Method O PRESCRIPTIVE METHOD -The shall be tested and verified as, having an air leakage rate. of not exceeding 7 air e obuilding Ir a 02'i c h w.ge(50 Puniiits changes-p p in Climate Zones 1 and 2. Q. 'PERFORMANCE or ERI 'METHOD -The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding, the selected ACH(50) value, as shown on Form R40S2017 (Performance) orR406-2017(ERI), section labeled as infiltration, sub -section ACH_ 50. ACH(50)spa clfied on Form 17405-2017wEnergy Cala(Performance) or R406-2017 (ERIJ Z000 x 60 = 15904 — Method for calculating building volume: CFM(50) Building Volume ACH(50) Q Retrieved from architectural plans ❑ PASS 10 Code software calculated When ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated must be verified by building department. R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to thecode official Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. Tesfing Company - Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification #: Issuing Authority: 10/26/2019 1:15:17 PM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1