HomeMy WebLinkAboutPlot Plans & SurveyDESIGN CRITERIA: APPLICABLE CODES. REGULATIONS & STANDARDS 1. THE 2017 FLORIDA BUILDING CODE, SPECIFICALLY CHAPTER 16 STRUCTURAL DESIGN, CHAPTER 20 ALUMINUM & CH. 23 WOOD. 2. AA ASM 35 & SPECIFICATIONS FOR ALUMINUM STRUCTURES, PART 1-A OF THE ALUMINUM DESIGN MANUEL PREPARED BY THE ALUMINUM ASSOCIATION. INC. WASHINGTON D.C. 2005 ED. 3. ASCE 7-10 & SET 4. NDS NATIONAL DESIGN SPECIFICATION FOR WOOD. 5. ACI318 CONCRETE REFRENCE MANUAL. WIND LOADS 1. BUILDING OCCUPANCY CATEGORY, PARAGRAPH 1604.5 & TABLE 1604.5: RISK CATEGORY 1. 2. BASIC WIND SPEED, TABLE 1609C, STATE OF FLORIDA DEBRIS REGION & BASIC WIND SPEED, PARAGRAPH 1609.3.1 & TABLE 1609.3.1 EQUIVALENT BASIC WIND SPEED: 150 MPH EXPOSURE CATEGORY, PARAGRAPH 1609.4.3: C 3. WIND LOADS PER FBC TABLE 2002.4 (MWFRS) V ULT = 150 MPH & EXPOSURE = C FOR 20 X 20 X 0.013" MESH SCREEN HORIZONTAL PRESSURES ON WINDWARD SURFACES = 43 PSF HORIZONTAL PRESSURES ON LEEWARD SURFACES = 34 PSF VERTICAL PRESSURES ON SCREEN SURFACES = 12 PSF VERTICAL PRESSURES ON SOLID SURFACES = 36 PSF FOR 18 X 14 X 0.013" MESH SCREEN, APPLIED FACTOR = .88 JO&ALLOWABLE STRESS DESIGN, APPLIED FACTOR = .6 AH 106.4.3: 10 PSF { AREVISION FOUNDATION DESIGN - __1 FOOTING SIZE EXISTING CONCRETE SLAB. NO ADDITIONAL FOOTING OR FOUNDATION SYSTEM IS REQUIRED BY THE PROPOSED CONSTRUCTION IF A MINIMUM 4" CONCRETE SLAB IS PROVIDED IN SOUND CONDITION, FREE FROM STRUCTURAL CRACKING, SPALLING & OTHER DETERIORATION. EXISTING FOUNDATION/FOOTING UNDER CONCRETE SLAB MINIMUM &'x8" W/ (1) #5 BAR TO BE VERIFIED BY CONTRACTOR. SEE TYPICAL FOOTING DETAILS FOR NEW FOOTING DESIGN MINIMUM REQUIREMENTS. SPECIFICATIONS THE FOLLOWING SPECIFICATIONS ARE APPLICABLE TO THIS PROJECT: 1. WHERE CONCRETE SPECIFICATIONS ARE REQUIRED, WHETHER IN THE SCREEN ENCLOSURE SCOPE OF NOT, BY ONE OR MORE REGULATORY AGENCY, THE FOLLOWING SPECIFICATIONS ARE APPLICABLE: a. CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING COMPONENTS: I. PORTLAND CEMENT TYPE 1 - ASTM C 150 ii AGGREGATES - LARGE AGGREGATE 3/4 MAX. - ASTM C 33 iii. AIR ENTRAINING +/- I %- ASTM C 260 iv. WATER REDUCING AGENT -ASTM C 494 v. CLEAN PORTABLE WATER A. OTHER ADMIXTURES NOT PERMITTED b. METAL ACCESSORIES SHALL CONFORM TO: L REINFORCING BARS -ASTM A615, GRADE 60 ii. WELDED WIRE FABRIC - ASTM A185 C. CONCRETE SLUMP AT DISCHARGE CHUTE NOT LESS THAN 3" OR MORE THAN 5". WATER ADDED AFTER BATCHING IS NOT PERMITTED. d. PREPARE & PLACE CONCRETE PER AMERICAN CONCRETE INSTITUTE MANUAL OF STANDARD PRACTICE, PART 1, 2, & 3 INCLUDING HOT WHEATHER RECOMMENDATIONS. e. MOIST CURE OR POLYETHYLENE CURING PERMITTED. f. PRIOR TO PLACING CONCRETE, TREAT THE ENTIRE SUBSURFACE ARE FOR TERMITES IN COMPLIANCE WITH THE FBC. g. CONCRETE SHALL BE PLACED OVER A POLYETHYLENE VAPOR BARRIER. 2. WHEN PAVERS ARE UNDER ALUMINUM MEMBERS, CONTRACTOR SHALL EPDXY TO DECK OR GROUT TO DECK w/3D00 PSI GROUT WITH BONDING AGENT 3. WHEN APPLICABLE FOR NEW SLAB ADDITION TO ADJACENT DRILL & EPDXY #5 X 8" REBAR INTO EX. FOUNDATION WITH 1"MIN. HOLE, EMBED 4" MIN W/ NON -SHRINKING SIMPSON EPDXY -TIE (OR EQUAL) 48" O.C. TYP. ALL LOCATIONS 4. WHEN APPLICABLE FOR NEW FOOTER TO EXISTING, DRILL & EPDXY NEW STEEL INTO EX. FOUNDATION WITH 1"MIN. HOLE, EMBED 6" MIN W/ NON -SHRINKING SIMPSON EPDXY -TIE (OR EQUAL) TYP. ALL LOCATIONS S. MINIMUM CONCRETE STRENGTH 3000 PSI UNLESS OTHERWISE NOTED. ALUMINUM SPECIFICATIONS 1. ALUMINUM EXTRUSIONS SHALL BE 6005 T5 ALLOY UNLESS OTHERWISE NOTED. 2. ALL SELF MATING BEAM SECTIONS ARE TO BE STITCHED WITH # 12 SCREWS 6" FROM ENDS & 24" CENTER TO CENTER. 3. ROOF BRACING SHALL BE A MINIMUM 2"X2"X.050". 4. THE MINIMUM NORMAL THICKNESS OF PROTECTOR PANELS (KICKPLATES) SHALL BE AN INDUSTRY STANDARD OF 0.024 INCHES. 5. VINYL AND ACRYLIC PANELS SHALL BE REMOVED WHEN WIND SPEEDS EXCEED 75 MPH PER FBC. 6. SCREEN MATERIAL SHALL BE 18/14 SCREEN UNLESS APPROVED BY FLORIDA ENGINEERING U.C. 5. 1"X2" & 1"X3" NON STRUCTURAL MEMBERS MAY BE USED INTERCHANGEABLY. FASTENER SPECIFICATIONS 1. FASTENERS ARE REQUIRED TO BE SAE GRADE 2 OR BETTER ZINC PLATED. (CONCRETE ANCHORS ARE TO BE TAPCONS OR BETTER, INSTALLED TO MFG. SPECIFICATIONS) 2. IT IS THE OWNERS RESPONSIBILITY TO MAINTAIN THE SCREENS, FASTENERS AND SCREENS TO MANUFACTURING SPECIFICATIONS. 3. WHERE WOOD DECK IS PRESENT USE 1/4" X 3-1/2" GALV. LAG SCREWS IN LIEU OF MASONRY ANCHORS. UNLESS OTHERWISE SPECIFIED. 4. 1 "X2" NON STRUCTURAL MEMBERS ATTACHED TO HOST A. FOR MASONRY/CONCRETE APPLICATION USE GALVANIZED 1 /4" X 2-3/4" TAPCONS OR EQUAL AT 24" O.C. AND 6" FROM ENDS B. FOR WOOD APPLICATION USE IT 14 X 2-0/4" WOOD SCREW AT 24" O.C. AND 6" FROM ENDS. C. FOR ALUMINUM APPLICATION USE #10 X 1-1 /2" SMS OR TEK SCREW AT 24" O.C. AND 6" FROM ENDS D. WHERE 1"X2" INSTALLED THROUGHOUT AN "OPEN VIEW" SPACING SHALL BE REDUCED TO 18" O.C. AND 6" FROM ENDS MASONRY SPECIFICATIONS 1. CONCRETE MASONRY UNITS (CMU) SHALL BE STANDARD HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED ON TYPE M OR S MORTAR. 2. ALL MORTAR SHALL BE TYPE M OR S. 3. ALL GROUT SHALL BE 2000 PSI MINIMUM AND HAVE MAXIMUM COARSE AGGREGATE SIZE OF 3/8". 4. PROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING REINFORCEMENT WHEN GROUT POUR EXCEEDS 5-0" IN HEIGHT. MISCELLANEOUS 1. SCREENED ENCLOSURES CONTAINING SWIMMING POOLS SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF FBC R4501.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS. 2. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME. IF THE EXISTING STRUCTURE IS ONE OF THESE, A SEPERATE 4TH WALL SUPPORT SYSTEM IS SO TO BE ENGINEERED SO THAT NO ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED HOME. 3. DOOR LOCATION MAY BE RELOCATED BY CONTRACTOR IN THE FIELD. 4. WHERE PAVERS ARE UNDER ALUMINUM MEMBERS, CONTRACTOR SHALL EPDXY TO DECK OR GROUT TO DECK w/3000 PSI GROUT WITH BONDING AGENT. 5. INTEGRITY OF EXISTING/ HOST STRUCTURE SHALL NOT BE COMPROMISED WITH THE ATTACHMENT OF THE PROPOSED STRUCTURE. 6. ALL 2X4 & GREATER ARE TO BE 2 x 4 SMB: 2'k4"x0.044"x0.100" UNLESS OTHERWISE INDICATED. RESPONSIBILITIES 1. ALL SITE WORK SHALL BE PERFORMED BY A LISCENED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDANANCES. AND THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES. 2. FOR FASTENERS WHICH ARE NOT VISIBLE AFTER INSTALLATION, THE CONTRACTOR SHALL VERIFY AND ENSURE INSTALLATION HAS BEEN ACCOMPLISHED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS AND IN ACCORDANCE WITH THE ATTACHED DETAILS. 3. FOR "PICTURE WINDOW" MODIFICATION TO EXISTING SCREEN ENCLOSURES; ALL OTHER "EXISTING SCREEN ENCLOSURE" FEATURES ARE TO MEET THE TYPICAL DETAILS AS PROVIDED IN THESE DETAILS. CONTRACTOR IS TO VERIFY & ASSURE EXISTING SCREEN ENCLOSURE IS STRUCTUALLY SOUND. ALUMINUM MEMBERS DIMENSIONS HOLLOW SECTIONS 2 x 2: 2'x2'x0.044" 2 x 3: 2'x3'x0.050" 2 x 4: 2"x4"x0.050" 2 x 5: 2"x5'x0.050" OPEN BACK SECTIONS 1 x2: 1"x2"x0.044" I x3: 1"x3'x0.045" SNAP SECTIONS 2 x 2 SNAP: 2"x2"x0.045" 2 x 3 SNAP: 2x3"x0.050" 2 x 4 SNAP: 2X4"x0.045" SELF MATING (SMB) 2 x 4 SMB: 2"x4"x0.044"x0.109' 2 x 5 SMB: 2"x5"x0.050"x0. 100" 2 x 6 SMB: 2x6"x0.050"x0. 120' 2 x 7 SMB: 2"x7x0.057'x0.I20' 2 x 8 SMB: 7x8" %D.D72"x0.124" 2 x 9 SMB: 2'k9"x0.082'k0. 124' 2 x 10 SMB: 2"x10"x0.092'x0.398" DETAIL A .............. O G = D o =0:Lu:O 10 w 4 Q C j v ....PROF /�y /////i//111111111kx\\\x \ REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY ..1� (,�� L/ v SOCC (Y v r C.03 V� File Copy J O LLo J m co o I Z Z 0 O -D of 0� p U U J w w Q O co- Z (if LL Lo � LLJ .� N M C V - � ^•i77 w<_j QC¢v Q U N� L.1_ r O J LL a w I` O CO v M I � J Z LL O Z OCi w ro Z d n = w w wOa CD 0 J o O I` O 1 w LL LO LL 'o rr a I DESIGN DATE: 12/13/2019 1 REVISION 1: 02/03/2020 REVISION 2: DATE PAGE: DRAWN BY: KHV SCALE: NTS 1 11 u ROOF RISE a• .)-------------- / i I g i i S I I w I 3'-0"CHAIR RAIL 12" x 12" FOOTER� BRICKPAVER DECK OPTION O SODDED GRpOE 2i_7u MIN. 17. /-71 12105 CONIBAa FOOTING NOTES OMINUOUS 1. PROVIDE I-I/Y COVERAGE TOP, SIDES. BOTTOM AND I"BETWEEN ADJACENT REBAR LAPS. 2. PROVIDE MIN. 3"COVERAGE OF REBAR FOR ALL CONCRETE IN CONTACT WITH THE EARTH. 3. FOOTING CONCRETE SHALL BE MIN. 3000 PSI AT 28 DAYS i. FOOTING REINFORCEMENT SHALL BE MIN. GRADE <0 S. PROVIDE POSITIVE DRAINAGE AWAY FROM STRUCTURE TO CITY / CO. REQUIREMENTS 6, PROVIDE 2SW PST BEARING (TYPICAL) UNDER FOUNDATION ). SEE GENERAL NOTES FOR WING INTO EXISTING FOUNDATIONS 8. SEE GENERAL NOTES FOR ADDITIONAL CONCRETE INFORMATION & SPECS. DETAIL "J" FOOTINGS SCALE: NTS 17'-9" 20'_4"—I ..... : F HOST 24" O/H STRUC. GUTTER s 2X3 --------- 2X3 I 2X3 0 I 1 fV � 2X3X.050 DIAG. BRACE TYP. 2X3 i 2X3 y_x m m 2X3 m m m :2 m N m 2 X,-.- N /;%:2X3N m x m N N N x N 2X3 2X3 2X3 3X2 % T -- ------------- „ -- i ` lx3 TYP. X2X3 ED ED DO ED 2X3 m x x L° LG x N x 1,1 _ � p N N N N N 2X3 TYP. }I - 1 2X3 1X3 TYP. I2X3 1 7'_5"__— _4_ 7' B" ,.1_-7'-8" 7- g'— I 7 8" —i 2X3X.050 DIAG. BRACE TYP. J 0 Q� /!/ N O LL O a N cC) m ., Lu 2 O•z- m N _C9 i o M U' O �bd ••.. w ELI //////lllI IIIIIIITL�\\\ U 1" REVIEWED FOR CODE COMPLIANCE STR L_UCIE COUNTY BOCC File Copy ROOF RISE PROFILE SCALE N.T.R 2x2x3ANGLE W/ (3) #14 TEKS EACH SIDE 'HORIZONTAL OR SLOPED EDGE MEMBER/ 1-12'X1x.062 RED. 2x2xl/8 ANGLE EAVE RAIL TO OR PURLIN W/ (4) #12x3/4" TEKS POST W/ (8) #14 EA. CLIP EACH SIDE IT 0 TABLE "E" ° o BEAM PER PLAN EDGE MEMBER BEAM Ott EACH SIDE/SIZE 0 o NOTCHED TO RECEIVE COLUMN WITHIN BEAM j OR PURLIN I0 0 ° 1 ° (2X6 ILLUSTRATED) 2X2X125 ANGLE Wl (4) #14 TEKS INSTALL BRACE TO CORNER NOTE' BRACE MAY I� BRACE is 1-1/2'Wx.062 RECEIVER CHANNEL _ W/ (4)#12x3/4" TEKS EACH SIDE(TYP.) j PURLIN 2x3 4112 2x4 5112 2%5 5/12 I I COLUMN PER PLANS FROM CORNER DETAI "D" DETAIL I I - ROOF BRACING CONNECTION SCALE: NTS 2 x 7 7/12 2x6 8/14 2x9 9/14 2 x 10 9/14 ION MAINTAIN MIN, OF 5/8"AM SMS O.C. TY FROM EDGE OF BEAM SMS O.C. TYP. DETAIL E - UPRIGHT TO BEAM CONNECTION SCALE: MS 1/8"xZ` 2"ANGLE � 4 -#14 SMS INTO COLUMN 3/8" x 4" TAPCON MIN 4"SLAB 30DO PSI CONC. wRBERMESH \ CONC. FOOTING SELF -MATING OR SNAP SECTION TYP. 1"x3" O.B. BASE PLATE-TYP. 0 0 2-14'x 1/4"MASONRY ANCHOR 1-Y.." MIN. CONC. ANCHOR EMBEDMENT 2" MIN. INCREASE DISTANCE WHEN GREATER THAN 2x4 ......... ....... UPRIGHT IS USED SIDEVIEW NOTE WHERE PAVERS ARE PRESENT USE 5116' TAPCON XL (RED HEAD MFG.) MASONRY ANCHORS TO PENETRATE UNDERLYING CONCRETE FOOTING 2-IM' (MIN.) 4-#14 SMS INTO COLUMN ,/3/8"x4"TAPCON 2 @ SLAB (BEYOND) I // 2-1/4"X1/4"TAPCON2@tx3 BASE E PLATE ANCHORED w/ 1/4" MASONRY 6" MAX EACH SIDE AND 24" O.C. MAX CONC. FOOTING BELOW—/ FRONT VIEW DETAIL "B" - 2"x4" OR LARGER SELF MATING UPRIGHT TO DECK DETAILS SCALE: NTS (4) #10xl1/2" SMS INTO SCREW BOSSES, u FASTEN TOP OF HEADER TO INTERSECTING 125 ANGLE ii 2"x3"MEMBER w/(2)910 SMS w/1" Ix3/4"TEKS PENETRATION INTO SCREW BOSS OF EACH SIDE 2"x3"MEMBER-TYP, BOTH SIDES 2x2x.125 ANGLE W/ (2) #10 SMS INTO COL 81/4" x 2-1/4" TAPCON THRU O.B. INTO CONCRETE 1.1/2" (MIN.) EMBEDMENT ALTERNATE BASE PLATE CONNECTION ATTACH 2"x3" TO BASE PLATE (INTERNAL) W(2) 0104" SMS PURLIN MEMBER ALUMINUM INTERNAL OR EXTERNAL UPRIGHT, BEAM -SNAP, SELF MATING, OR HOLLOW DETAIL "C" - GIRT OR PURLIN TO BEA ORPOSTDETAIL SCALE:NTS 114'. TAPCON (RED HEAD MFG. OR EQUAL) WITHIN 6" OF COLUMN 11/2" PENETRATION INTO UNDERLYING FOOTING DETAIL'F' •DOOR JAMB 8 HEADER . O° �.'ti;''% �o�..° C: J cq O ZD ^o O z W z° ''�//llll 111 Hk\ x. U� J O Ln Z Z Q O U n/ LL p U wJODD- W Q L,L Lo •� Z ~ W r N (_ f�M C Z�O�-c W cQ Q G = �Q- U Ora 0 J � 12- REVIEWED FOR CODE COMPLIANCE ST° LUC®IE COUNTY ®OCC Ql \ He Copy °x2"x.063"- DIM. TO MATCH PURLIN IZE RECEIVING CHANNEL PURLIN 1) #12 SMS INTERNAL TO EAVE AIL (2) #12 EACH SIDE INTO PURLI W Z LL Z F W EAVE RAIL - 3xL " O U w 1n U Z D_ N 0UPRIGHT W W O D- ix30PEN BACK EXTRUSION O p ' Z)0¢ Lo Ir 0 0UL r- 0 2x2xl/8 ANGLE EAVE RAIL T Y UL POSTW/(B)#14EA. CLIP z O O I I 0 0 a DESIGN DATE: 12/13/2019 REVISION V 02/03/2020 DETAIL "G" -SLOPED PURLIN REVISION 2: DATE PAGE: CONNECTION SCALE:NTS DRAWN BY: KHV /� SCALE: NTS J FOR BEAMS ABOVE 2x8 INSTALL GUTTER BRACE AT MIDPOINT BETWEEN BEAMS 81NCLUDE 2" GUTTER BRACE AT EACH BEAM LOCATION BEAM A F(2) #12 SMS 0 .044 RECEIVING CHANNEL, FASTEN w/(1) #12 SMS EACH SIDE OF BEAM 2x2x4x1/8"ANGLE EA. SIDE OF BEAM w/(4) #14 TEKS EACH LEG EACH S ANGLE W/ (4) #14 TEKS SIDE VIEW TOP VIEW DETAIL "H" SCALE: NTS WOOD SCREWS@ V IG @ EACH GUTTER BRACKET 18" D.C. MAX. ABEDMENT SHALL BE 2" R TO 18" O.C. (2) #12 SMS (2)#14x2" WOODSCREW EXISTING WOOD FASCIA STRUCTURAL GUTTER o 0 FJo I IF 0 0 0 0 0 0 I `P" 4 0 0 0 0 0l I 0 F 3116"5052-H32 GUSSET 1\ Y F INTERNAL OR EXTERNAL 8" INTO EA. SIDE TYP. F (2X6SMB ILLUSTRATED) SCREW QUANTITY NOTE F INSTALL FASTENERS ALONG PERIMETER OF GUSSET 2X6 AND LESS THAN 3 ROWS OF(4)#14 -BEAM JOINT 3/9'MIN, FROM EDGE. FASTENERS FOR 2X7 AND GREATER 4 ROWS OF(4)#14 MAY BE STAGGERED TO INSURE PROPER QUANTITY PER TABLE B-1 'NOTE: FOR SPANS OVER 33' ADD ANOTHER ROW FASTENER PATTERN MAY APPEAR DIFFERENT FROM ILLUSTRATION. MAINTAIN 1/2" SEPARATION BETWEEN FASTENERS. MAINTAIN 3/8" MIN, FASTENER SEPARATION FROM BEAM JOINT OR EDGE OF BEAM LAP FASTENERS MAY BE EVENLY SPACED AROUND EDGE OF GUSSET WITHIN 3/8" OF BEAM JOINT. FASTENERS MAY BE STAGGERED TO INSURE PROPER QUANTITY PER TABLE BA DETAIL "K" GUSSET CONNECTION SCALE:NTS .050" GUTTER STIFFNER FASTEN TO FASIA w(2) #12x2" WOOD SCREW FASTEN TO GUTTER w(2) #12SMS DETAIL "M" BEAM & PURLIN TO GUTTER CONNECTION SCALE:NTS (2) 912 SMS 2x2x1a' ANGLE w/(2) #12 SMS EA- LEG, SMB L 1/8"x2'k4" STRAP (2) #12 SMS INTO BEAM (2) #12 SMS INTO GUTTER 2x2x1/8" ANGLE w/(2) #12 SMS EA. LEG , WHEN BEAM & PURLIN HIT ON CORNER - FASTEN OUTSIDE OF BEAM 8 PURLIN W 1/9W'12" ANGLE 8 (4) #12 SMS EACH LEG FASTEN INSIDE CORNER (BEAM TO PURLIN) w/ 1/8"x2"x2" ANGLE w/(2) #12 SMS INTO EA. MEMBER (BEAM 8 PURLIN) 4 WOOD SCREWS FASCIA GIRT I o ,u SIDE VIEW \ , STRUCTURALGUTTER POST (2) #12 TEKS (TYP.) EA. MEMBER (FOR SPANS OVER 32' USE #14 TEKS) x 3 x 0.05 .�.�,. LATERAL "IC' -BRACING CONNECTION DETAILS V 6063-T6 ALLOY PLATE GIRT (2) GUTTER BRACES (ONE SIDE) OR STRONGER EACH w/(2)#12 SMS FASCIA INTO GUTTER B(2)#14 WOOD SCREWS INTO FASCIA K-BRACE 2x3%0.050 CHAIR RAIL (2) #12 SMS SMB 1/8'1Q'X4" STRAP (2) #12 SMS INTO BEAM GIRT (2) #12 SMS INTO GUTTER STRUCTURAL GUTTER 'ALTERNATELY USE 2x2x1/8ANGLE TOP VIEW DETAIL "L" CORNER CONNECTION SCALE:NTS K-BRACE 2 x 3x 0,050 BRACE(TYP 3 x 0.050 NCE (TYP.) C-; Q:� N O O_:p Z o w =(7:L) 1O Q O EAVE RAIL 1"x 3" O.B. PATIO SECTION EWER FOR .OMPLIANCE —K-BRACE CIE COUNTY EOCC File sC®PY 0 O O GIRT (CHAIR RAIL) -- 0 (2) 912 TEKS IT EA. MEMBER IF SPANS OVER 3 USE #14 TEKS) LATERAL"K"-BRACING CONNECTION DETAILS U c:) c\I Lo m 0 .J co M ZZp O �y LL CD U U O WJODDm LU < LL Lo .0 Z 2' ~ r W r— v— ~^CD z 0 v c Q U 0 � W O C)O 1h LL Nr rn T O z U LLl a 0 U) Z LL O O LLf co U C) u n Z D' 2: W_ UJ x W O O- O Q > u r- Y O OLO w LL LL O a SIGN DATE: 12/13/2019 (ISION 1: 02/03/2020 (ISION 2: DATE PAGE: LWN BY: KHV 1LE: NTS t 15.2' EAST NORTH LINE OF THE SE 1/4 OF THE NE 1/4 NE CORNER 1/4 ( OF THE SE 1/4 1/4 I OF THE NE.1/4 SCALE: 1"=100' APPROXIMATE TOP OF DITCH APPROXIMATE TOP OF DITCH SINGLE FAMILY FD.%" I.R. „ , RESIDENCE NO CAP S. 89'36 55 E. 1227190 0 o FD )k" I.R. 1GAR0.01� --� ¢ W/CAP"RLS 2391" F.F.E.= v r16.9'x22' CONCRETE DRIVE van O ° } WITNESS CORNER 27.90' EAST ' s 577,7' tii � a 4 y, rn IJ 4'x24' CONC. SLA n CONCRETE WALK a M Z 3 O` z g£ • 3 2'x5' CONC. PAD (PUMP) QLL o ram- w 6z1,s'' a2y 5.51 ACRES f N am¢ I•rnN i _. •2'0 .3� A G .0 U ado 3: 4'xl VCONCRE WALK rn ZI 12'x18' COVERE PORCH r az.s' - - , ,� 561,2' . ^ O C.)� , m I N. 00'32 51 E a t3 0 1\ 1 STORY RESIO bE N 11.18' (D&M) Z o POND F.F.E: 22.iO N. 89'36'55" W. 300.00' D&M .. z �o'I� g FD 1" LPIPE N. 8936'55" W. 624.55' (M) INGRESS —EGRESS SET Ya" I.R. • 2 WITNESS CORNER , , g EASEMENT W/CAP. F3435 p 4 x4 CONC. pAD 27.13' EAST I d mo SET,, LR: FD.Y2" LR. . VACANT' 3'x4' COVERED ENTRY W/CAP #3435 CAP UNREADABLE , n SETBACK REQ FRONT ' SIDES CNR SIDES Note: REAR Elevations shown Hereon ore NAVD 88 based on a bench run ZNG• S l from NGS Monument D201 (PID—AF3319) elevation 17.47, TECHTo convert to NGVD 29 add 1.54 feet per NGS calculations. Certified to: ' 41.5' WEST Harbor Community Bank OWNER. Stephanie M. Fowler SW CORNER OF THE N 1/2 Brian C. Fowler & Stephanie M. Fowler PERMIT TYPE: Building Residential (SFR) OF. THE SE 1/4 Homecrete Homes, Inc. Building OF THE NE 1/4 SEE SHEET 2 OF 2 FOR DESCRIPTION AND SURVEYOR'S REPORT First American Title Insurance Company Bug (Misc.) Garage Address: 5775 Johnston Road CERTIFICATE OF SURVEYOR I herehy aeru'y the' fhie Survey wua made under my JAMES A. FOWLER, P.S.M. FINAL SURVEY b at bagq kaoChurvl d�°�ee'�i r '�1B 6495 OXFORD CIRCLE, u1 O1 ' VERO BEACH, FLORIDA 32966 J S A. V028R, P.S.M. q �SPIi�iIl' StGp]�IlBnAe Fowler' F RIDA,REGISTRATION No. 3435 FLORIDA LICENSE N0. eJ435 DRAWN BY:.D.F. SCALE: 1"= 100' DAIS: 12-13-2013 SHEE 1 OF 2