HomeMy WebLinkAboutStructural Assessment Reporto Ebbstone To: Mr. William baa4k,Date: 20-Apr-20 .+� �l V Job Number: ?t���►� Reference: 4006 Avenue P signed and sealed Structural plans and Report We are sending you Elherewith under separate cover prints Otracings shop drawing§ specifications Flother as described below as follow: NUMBER OF COPIES DRAWING OR JOB NUMBER DATED DESCRIPTION 4 04/20/20 4 sets of signed and sealed drawings 1 Report Via: Hand Delivrery cc.: Yours very truly, E stone, Inc. Ja ques Re - e, P.E. Vice President William 04 20 2020.xls L «r. fir• �- -'� -Qu ?.o lil L 11L J. ld.v l T G • V I il[�5 1 .r�s-t�; ,..n `�b ,Id: a��v`• hr. «.,�..a .4e . r. -di; . -�'•� t . ��'4�.�.�„ ,.`r �'\\f Avenue P Structural Assessment Report 4006 Avenue P. Ft. oierce FL ENGINEER'S CERTIFICATION This document and the information contained within have been prepared solely for the use of the Jacques Registe and St. Lucie County Planning & Development Services, Building &Code Regulation Division (BCRD). This Assessment is based solely upon the information made available to or gathered by Ebbstone, Inc. EBBSTONE does not assume responsibility for unforeseen conditions, or conditions not recognized as unacceptable at the time this report was prepared. This Assessment and subsequent recommendations are based solely on the visual inspection of the structure and no testing of materials was performed. EBBSTONE performed the inspection, prepared this report, and makes the following recommendations in a manner consistent with sound practices, level of care, and the skills normally exercised by members of the engineering profession operating under similar circumstances. This report and the discussion contained herein shall not, in whole or in part, be disseminated or conveyed to any other party or used or relied upon by any other party, in whole or in part, without prior written consent. I, Jacques Registe, P.E., hereby state that this Assessment, as listed in the Table of Contents, is, to the best of my knowledge and belief, true and correct and represents the described work in accordance with current established engineering practices. I hereby certify that I am a Licensed Professional Engineer in the State of Florida practicing with Registe, Sliger Engineering, Inc., and that I have supervised the preparation of and approve the evaluations, findings, opinions and conclusions hereby reported. This document has been signed and sealed by Printed copies of this document are not considered signed and sealed Ebbstone, Inc. 1125 NE 125'h Street, Suite 503 North Miami, Florida 33161 Phone (850) 544-1402 Certificate of Authorization No. 9292 Jacques Registe, P.E. Florida P.E. #43397 Page i February 19 2020 4 Avenue P Structural Assessment Report 4006 Avenue P, Ft. pierce FL Table of Contents Engineer's Certification.................................................................................................... i Tableof Contents.............................................................................................................ii 1.0 EXECUTIVE SUMMARY... ................................................................................... 1 1.1 Findings & Recommendations................................................................... 1 2.0 PURPOSE............................................................................................................2 2.1 Project Scope of Services.......................................................................... 2 3.0 BUILDING STRUCTURAL ASSESSMENT..........................................................2 3.1 Building Location....................................................................................... 2 3.2 Building Parameters and Exterior Wall Openings ...................................... 2 3.3 Exterior Walls Structural Condition Assessment ........................................ 3 3.4 Roof Structural Condition Assessment...................................................... 5 4.0 MODELING OF LOADS....................................................................................... 7 4.1 Wind Load Parameters and Calculations................................................... 7 4.2 Analysis..................................................................................................... 8 4.3 Results.......................................................................................................8 5.0 RECOMMENDATIONS........................................................................................ 9 APPENDICES Wind Load Calculations...................................................................................Appendix A DesignPlans..................................................................................................Appendix B Page ii February 19, 2020 4 Avenue P Structural Assessment Report 4006 Avenue P, Ft. pierce FL 1.0 EXECUTIVE SUMMARY This Structural Assessment Report compares the Building's Main Wind Force Resisting System to wind loads generated by hurricane forces. This report contains Ebbstone, Inc.'s (EBBSTONE) opinion and professional judgment of the existing condition of the house structure located at 4006 avenue P, Fort Pierce, Florida. Main Wind Force Resisting System (MWFRS) are the structural elements assigned to provide support and stability for the overall structure. The opinions and analysis provided by EBBSTONE are based on visual evidence only. EBBSTONE is not responsible for the assessment of the conditions of non -visible structural elements. Destructive testing and non-destructive testing were not performed. EBBSTONE performed a visual structural inspection of the house located at 4006 avenue P, Fort Pierce, Florida on January 6, 2020. The inspection was conducted by Jacques Registe, P.E. Wind loads were calculated using ASCE 7-10 methodology. EBBSTONE has made every effort to reasonably present the various areas of concern identified during our site visit. If there are perceived omissions or misstatements in this report regarding the observations made, we ask that they be brought to our attention as soon as possible so that we have the opportunity to fully address them in a timely manner. This report has been prepared on behalf of and for the exclusive use of St. Lucie County BCRD. 1.1 Findings & Recommendations EBBSTONE's inspection of the house structure included a visual inspection of the exterior and interior of the house. EBBSTONE has not noted any cracks along the exterior wall and no cracks were found on the inside of the exterior walls of the house. The visible elements of the roof truss system showed no sign of deterioration. It is our opinion that the MWFRS are in good condition and no reduction in capacity due to service conditions were applied to individual structural elements during our analysis. Based on our analysis, it is EBBSTONE's opinion that the structural elements composing the building's MWFRS can withstand loads generated by category 5 hurricanes if the following repairs are made. EBBSTONE recommends installing new hurricane straps to the roof rafters and to the studs to beam connection. A continuous load path capable of resisting the uplift of the roof from the bond beam to the foundation needs to be provided. We recommend installing joistibeam connection tie down, adding one more thru bolt to beam/column connection, completely secure the handrail system and secure the bond(parameter) beams. We recommend to re -nailing the plywood floor system, blocking all the floor joists at least 3' from the ends and installing minimumY2" CDX plywood sheeting. We also recommend installing approved shutters on all the windows. Page 1 February 19, 2020 Avenue P Structural Assessment Report 4006 Avenue P. Ft. pierce FL V��1•'111:71eb9 The purpose of this structural assessment is to satisfy the Florida Building Code (FBC) section 907.4.2 substantial structural alteration. Where more than 30 percent of the floor and roof areas of the building have been altered, the evaluation shall demonstrate that the lateral load resistance system of the structure complies with the FBC. The analysis will use the building's Main Wind Force Resisting System to wind loads generated by hurricanes forces to check the house. The house was just bought by Jacques. This Report will evaluate the house located at 4006 Avenue P, Fort Pierce Florida 34947. 2.1 Project Scope of Services The general objective is for EBBSTONE to prepare a report for the above referenced house to be used by the BCRD to determine if the house is structurally adequate to resist the wind loads generated during a major storm event. There were no existing structural building plans, so all findings presented in this report are based upon our measurements and visual inspection of the exposed structural building components. For all structural elements that were not exposed, EBBSTONE made a conservative assumption based on historic South Florida Building Code requirements on the size, type, and condition. In addition, EBBSTONE prepared a set of renovation plans for the house as shown in Appendices B. 3.0 BUILDING STRUCTURAL ASSESSMENT 3.1 Building Location The house is located at 4006 Avenue P, Fort Pierce Florida 34947. This house is located in a dense urban area, with no open areas or waterbodies greater than 5,000' in the surrounding terrain. See Figure 1 below for Project Location Map. 0 Figure 1 — Project Location Map 3.2 House Parameters and Exterior Wall Openings Per the St. Lucie County Property Appraiser, the house was constructed in 1983. No existing building plans were available for review. Therefore, field measurements of the Page 2 February 19, 2020 Avenue P Structural Assessment Report 4006 Avenue P, Ft. pierce FL building dimensions were used. Assumptions were made based on the field inspection and historic South Florida Building Code dated 1971. The building is a 1 story house on pile, 19' tall with approximately 912 square feet of house space. The house is approximately 24' wide by 39' long. The house is constructed of wood frame with a gable roof as shown below in Photo 1. Photo t — House Exterior The house has the following exterior wall openings: • The front of the front facing north has two double 6' wide glass door. • The west face of the building has three windows and one entry door. • The north side of the building has two windows. • The east side of the building has three windows. Roof members consisted of 2x6 wood rafters at two feet on center supported directly on the double 2x4 top plate. The roof deck consists of plywood. EBBSTONE was unable to determine the 10"x10" PT pile/column foundation depth, but there was no sign of settlement. 3.3 Exterior Wall Structural Condition Assessment No cracks or any structural damage was found in the inside face of the wall. However, wood rot was observed at the bottom of the entry door and some siding planks were missing. Based on the visual inspection, EBBSTONE believes that the condition of the structural elements of this building do not warrant a reduction in the calculated resistance of the exterior wall structural elements. Page 3 February 19 2020 Avenue P Structural Assessment Report 4006 Avenue P, Ft. pierce FL 3.4 Roof Structural Condition Assessment Based on the visible area of the roof structure, plywood roof decking is supported by wooden slope rafters. The rafters were placed 2' on center. The rafter that were visible showed no damage or deterioration except at the exterior eve location where there were some deteriorations. see Photo 3 on the following page. Photo 4 — Rafter layout and spacing Uplift resistance was not verified since there is no attic to look at rafters' connection to the top plate. Therefore, tie down of the rafters should be provided and secured to top plate. All visible straps should be galvanized. 3.5 Floor Structural Condition Assessment Based on the visible area of the floor structure, plywood decking is supported by wooden joists. The joists were placed at 16" on center. Most of the joists that were visible appear to have been replaced recently. Those joists need to be blocked and tied down to the beams. Page 5 February 19 2020 Avenue P Structural Assessment Report 4006 Avenue P. Ft. pierce FL Photo 5 — Joists layout and spacing require blocking and tie down Photo 6 — Beams to Column Connection Require another bolt Page 6 February 19 2020 Avenue P Structural Assessment Report 4006 Avenue R Ft. pierce FL 4.0 MODELING OF LOADS The basic loads considered in this study are dead loads (DL), live loads (LL), and wind loads (WL). The values of DL are calculated from the unit weights of various building materials used in the analysis. The LL intensities for the various areas of the building are obtained from the 2017 Florida Building Code. The summary of DL and LL considered for the building is given in Appendix A, Summary of Wind Load Calculations. According to ASCE 7-10, Chapter 2, Section 2.4, only 60% of the DL was used in the calculations. EBBSTONE assumed the following: all studs were 2x4 on 16" O.C.; continuous load path was not provided; and all doors and windows are not hurricane resistant. 4.1 Wind Load Parameters and Calculations EBBSTONE calculated the wind loads on the building using ASCE 7-10, Chapter 26 (Wind Loads: General Requirements), Chapter 27 (Wind Loads on Building MWFRS (Directional Procedure), Chapter 28 (Wind Loads on Building MWFRS (Envelope Procedure) and Chapter 30 (Wind Loads -Component and Cladding). Required wind loads were calculated using the wind speeds of Saffir-Simpson Hurricane Scale as a guide. Wind loads was determined using specific 3 second gust wind speeds of 158 mph (122 mph sustained wind speed, Category 5 Hurricane). In determining pressures for the building envelope areas, five basic factors were considered: 1. Building Height — Higher roof areas will have stronger wind velocity. The analysis used the measured height of 20'. 2. Building Location —Wind maps are included within ASCE 7-10 so that the local basic wind speed can be determined. See Figure 1 — Project Location Map. 3. Surrounding Terrain — The more obstructions there are around a building, the more they will break up the wind and assist in reducing the wind effect. Knowing the building is located in an urban area with no large open areas or waterbodies, the specific exposure is B. Refer to ASCE 7-10, Chapter 26. 4. Building Openings — The more openings in a building, the greater the chance of internal pressure increasing in a wind event. Due to the openings not having approved shutters, a partially enclosed structure was used in our analysis. Page 7 February 19, 2020 Avenue P Structural Assessment Report 4006 Avenue P, Ft. pierce FL 5. Building Use or Risk Category of the Building — This factor is based on how important the building is to the surrounding infrastructure in terms of people's safety. If building failure occurs, risk to human life exists. The risk category used was II. 4.2 Analysis Effects of wind on a building include internal pressurization, increased lateral forces, uplift, and external pressures. Internal pressurization occurs when wind enters a building and lateral forces act either inward, created by the wind blowing directly on the face of a building, or outward, due to suction forces created when low pressure conditions occur inside the building. Most buildings are designed as enclosed structures with no large or dominant openings in the envelope that allow wind to enter. However, a breach in this normally enclosed building envelope due to broken windows, failed entry doors, or a failed garage door causes a significant increase in the net effective wind loads acting on the building under strong wind conditions. In such cases, the increased wind load may initiate a partial failure or cause a total failure of the primary structural system. Therefore, partially enclosed building was used in this analysis. Primary structural systems are those that support the building against lateral and vertical loads. The MWFRS consists of structural elements assigned to provide support and stability for the overall structure. The system generally receives wind loading from more than one surface. Many buildings have structural systems that provide continuous load paths for high winds, but that were not sufficient for the extreme lateral and vertical uplift forces generated by tornadic winds that occur within hurricanes. Winds moving around a structure create vertical and lateral forces that act on the building and cause several different failure modes. 4.3 Results EBBSTONE performed an analysis of the various MWFRS structural elements to determine its ability to resist wind loads generated by a hurricane. Our findings are as follows: The "weakest link" in resisting the uplift forces acting on the roof elements was determined to be the nailed connection between the top plate and the wooden rafters and joists. Since that connection was not visible, we assumed the connection was nailed with 2 No. 16 D nails which provide approximately 600 lbs. per end of rafters as calculated. Therefore, these nails are not adequate to carry loads generated by a major hurricane. See Appendix A for Wind Load Calculations. Lateral stability is provided via the roof and the floor diaphragm. All the floor joists shall be framed as a woos structural panel diaphragms in that they all should be blocked at the panel ends and be the same size. The joists should also be tied to the joist/beam Page 8 February 19 2020 Avenue P Structural Assessment Report 4006 Avenue P, Ft. pierce FL connections. Floor/ceiling sheeting should be fastened with galvanized 10D ringshank nails spaced at 4" o.c. at panel edges and ends, 6" o.c. in the field of the panel. 5.0 RECOMMENDATIONS Based on our analysis, it is EBBSTONE's opinion that the structural elements composing the building's MWFRS can withstand loads generated by Category 1 and 2 hurricanes but will fail during a category 3 thru 5 hurricanes. Therefore, Ebbstone recommends installing new hurricane straps to the roof rafters and to the studs to beam connection. A continuous load path capable of resisting the uplift of the roof from the bond beam to the foundation needs to be provided. We recommend installing joist/beam connection tie down, adding one more thru bolt to beam/column connection, completely secure the handrail system and secure the bond(parameter) beams. We recommend to re -nailing the plywood floor system, blocking all the floor joists at least 3' from the ends and installing minimum CDX plywood sheeting. We also recommend installing approved shutters on all the windows. Page 9 February 19, 2020 Ebbstone, Inc. 1125 NE 125th Street, Suite 503 North Miami, Florida 33161 850-544-1402 754-222-9155 JOB TITLE 4006 Avenue P Category 5 Hurricane Calculations JOB NO. SHEET NO. CALCULATED BY JR DATE 1/20/20 CHECKED BY JFS DATE 1/23/20 CS15 Ver 2016.12.28 . www.struware.com STRUCTURAL CALCULATIONS FOR 4006 Avenue P Fort Pierce Florida Ebbstone, Inc. JOB TITLE 4006 Avenue P 1125 NE 125th Street, Suite 503 Category 5 Hurricane Calculations North Miami, Florida 33161 JOB No. SHEET No. 850-544-1402 CALCULATED BY JR DATE 2/4/19 754-222-9155 CHECKED BY JFS DATE 2/4/19 www.struware.com Code Search Code: Florida Building Code2017 Occupancy: Occupancy Group = R Residential Risk Category & Importance Factors: Risk Category = II Wind factor= 1.00 Snow factor= 1.00 Seismic factor= 1.00 Type of Construction: Fire Rating: Roof = 0.0 hr Floor= 0.0hr Building Geometry: Roof angle (0) 4.00 / 12 18.4 deg Building length (L) 38.0 ft Least width (B) 24.0 ft Mean Roof Ht (h) 19.5 ft Parapet ht above grd 0.0 ft Minimum parapet ht 0.0 ft Live Loads: Roof 0 to 200 sf: 20 psf 200 to 600 sf: 24 - 0.02Area, but not less than 12 psf over 600 sf: 12 psf Floor: Typical Floor 50 psf Partitions N/A Partitions N/A Partitions N/A Partitions N/A Ebbstone, Inc. JOB TITLE 4006 Avenue P 1125 NE 125th Street, Suite 503 Category 5 Hurricane Calculations North Miami, Florida 33161 JOB NO. SHEET NO. 850-544-1402 CALCULATED BY JR DATE 1/20/20 754-222-9155 CHECKED BY JFS DATE 1/23/20 Wind Loads: ASCE 7 - 10 Ultimate Wind Speed 158 mph Nominal Wind Speed 122.4 mph Risk Category II Exposure Category B Enclosure Classif. Partially Enclosed Internal pressure +/-0.55 Directionality (Kd) 0.85 Kh easel 0.701 Kh case 2 0.619 Type of roof Gable T000araohic Factor (Kzt Topography Flat Hill Height (H) 0.0 ft H< 60ft;exp B Half Hill Length (Lh) 0.0 ft :. Kzt=1.0 Actual H/Lh = 0.00 Use H/Lh = 0.00 Modified Lh = 0.0 ft From top of crest: x = 0.0 It Bldg up/down wind? upwind H/Lh= 0.00 K, = 0.000 x/Lh = 0.00 K2 = 0.000 z/Lh = 0.00 K3 = 1.000 At Mean Roof Ht: Kzt = (1+KIK2K3)A2 = 1.00 Gust Effect Factor h = 19.5 ft B = 24.0 It /z (0.6h) = 30.0 It Rigid Structure e = 0.33 t = 320 It Zmin = 30 ft o = 0.30 9o, 9v = 3.4 Lz = 310.0 ft Q = 0.92 Iz = 0.30 G= 0.88 use G=0.85 2D RIDGE or 3D A%ISYMMETRICAL HILL Flexible structure if natural frequency < 1 Hz (T> 1 second). However, if building h/B <4 then probably rigid structure (rule of thumb). h/B = 0.81 Rigid structure G = 0.85 Using rigid structure default Flexible or Dvnamically Sensitive Structure Natural Frequency (n,) = 0.0 Hz Damping ratio (P) = 0 /b = 0.45 /a = 0.25 Vz= 101.8 Nt = 0.00 Rn = 0.000 Rh = 28.282 n = 0.000 Re = 28.282 n = 0.000 RL = 28.282 n = 0.000 9R = 0.000 R = 0.000 G = 0.000 h = 19.5 ft Enclosure Classification Ebbstone, Inc. Joe TITLE 4006 Avenue P 1125 NE 125th Street, Suite 503 Category 5 Hurricane Calculations North Miami, Florida 33161 JOB NO. SHEET NO. 850-544-1402 CALCULATED BY JR DATE 1120/20' 754-222-9155 CHECKED BY JFS DATE 1/23/20 Test for Enclosed Building: A building that does not qualify as open or partially enclosed. Test for Open Building: All walls are at least 80% open. AD >_ 0.8Ag Test for Partially Enclosed Building: Input Test AD 300.0 sf AD >_ 1.1Aoi YES Ag 960.0 sf Ao > 4' or 0.01Ag YES AD! 162.0 sf Aoi/Agi 5 0.20 YES Building IS Agi 5264.0 sf Partially Enclosed Conditions to qualify as Partially Enclosed Building. Must satisfy all of the following: Ao>_ 1.1Aoi AD> smaller of4'or0.01Ag Aoi / Agi 5 0.20 Where: Ao = the total area of openings in a wall that receives positive external pressure. Ag = the gross area of that wall in which AD is identified. Aoi = the sum of the areas of openings in the building envelope (walls and roof) not including AD. Agi = the sum of the gross surface areas of the building envelope (walls and roof) not including Ag. Reduction Factor for large volume partially enclosed buildings (Ri) : If the partially enclosed building contains a single room that is unpartitioned , the internal pressure coefficient may be multiplied by the reduction factor Ri. Total area of all wall & roof openings (Aog): 0 sf Unpartitioned internal volume (V) : 0 cf Ri = 1.00 Altitude adjustment to constant 0.00256 (caution - see code) : Altitude = 5 feet Average Air Density 0.0765 Ibm/ft3 Constant= 0.00256 Ebbstone, Inc. 1125 NE 125th Street, Suite 503 North Miami, Florida 33161 850-544-1402 754-222-9155 JOB TITLE 4006 Avenue P Category 5 Hurricane Calculations JOB NO. SHEET NO. CALCULATED BY JR DATE 1/20120 CHECKED BY JFS DATE 1/23/20 Wind Loads - MWFRS hS60' (Low-rise Buildings) Enclosed/partially enclosed only Kz = Kh (case 1) = 0.70 Edge Strip (a) = 3.0 ft Base pressure (qh) = 38.1 psf End Zone (2a) = 6.0 ft GCpi = +/-0.55 Zone 2 length = 12.0 ft Wind Pressure Coefficients CASE A CASE B 9= 18.4 deg Surface GCpf w/-GCpi w/+GCpi GCpf w/-GCpi w/+GCpi 2 -0.69 -0.14 -1.24 -0.69 -0.14 -1.24 3 -0.47 0.08 -1.02 -0.37 0.18 -0.92. 4 -0.42 0.13 -0.97 -0.45 0.10 -1.00 5 0.40 0.95 -0.15 6 -0.29 0.26 -0.84 1 E 0.78 1.33 0.23 -0.48 0.07 -1.03 2E -1.07 -0.52 -1.62 -1.07 -0.52 -1.62 3E -0.67 -0.12 -1.22 -0.53 0.02 -1.08 4E -0.62 -0.07 -1.17 -0.48 0.07 -1.03 5E 0.61 1.16 0.06 6E -0.43 0.12 -0.98 Ultimate Wind Surface Pressures (psf) 2 -5.3 -47.2 -5.3 -47.2 3 3.1 -38.8 6.8 -35.0 4 5.1 -36.7 3.8 -38.1 5 36.1 -5.7 6 9.9 -32.0 1 E 50.6 8.8 2.7 -39.2 2E -19.8 -61.6 -19.8 -61.6 3E -4.7 -46.5 0.8 -41.1 4E -2.6 -44.4 2.7 -39.2 5E 44.1 2.3 6E 1 4.6 -37.3 Parapet Windward parapet = 0.0 psf (GCpn =+1.5) Leeward parapet = 0.0 psf (GCpn = -1.0) Horizontal MWFRS Simple Diaphragm Pressures (Ps Transverse direction (normal to L) Interior Zone: Wall 35.5 psf Roof -8.4 psf " End Zone Wall 53.2 psf Roof -15.1 psf " Longitudinal direction (parallel to L) Interior Zone: Wall 26.3 psf End Zone: Wall 39.6psf NOTE: Total horiz force shall not be less than that determined by neglecting roof forces (except for MWFRS moment frames). The code requires the MWFRS be designed for a min ultimate force of 16 psf multiplied by the wall area plus an 8 psf force applied to the vertical projection of the roof. Windward roof overhangs = 26.6 psf (upward) add to windward roof pressure Location of MWFRS Wind Pressure Zones Ebbstone, Inc. JOB TITLE 4006 Avenue P 1125 NE 125th Street, Suite 503 Category 5 Hurricane Calculations North Miami, Florida 33161 JOB NO. SHEETNO. 850-544-1402 CALCULATED BY JR DATE 1/20/20 754-222-9155 CHECKED BY JFS DATE 1/23/20 ZONE 2: lessor of 0.5 B or 2.5 h ,If 2 is negative CASE A L"Wrm =CTION RANGE CASE B WLSID DIRECTION RANGE NOTE: Torsional loads are 26% of zones 1 - 6. See code for loading diagram. ASCE 7 -99 and ASCE 7-10 (& later) \j,�"•. = �.If 2snegati• 1E 1VMDMECHON r Transverse Direction Longitudinal Direction NOTE: Torsional loads are 26% of zones 1 - 4. See code for loading diagram. Ebbstone, Inc. JOB TITLE 4006 Avenue P 1125 NE 125th Street, Suite 503 Category 5 Hurricane Calculations North Miami, Florida 33161 JOB NO. SHEET NO. 860-544-1402 CALCULATED BY JR DATE 1120120 754-222-9155 CHECKED BY JFS DATE 1/23/20 Ultimate Wind Pressures Wind Loads - Comoonents & Claddina : h <= 60' Kh(case 1)= 0.70 h= 19.5 ft Base pressure (qh) = 38.1 pat a = 3.0 ft Minimum parapet ht = 0.0 It GCpi = +/-0.55 Roof Angle (0) = 18.4 deg Type of roof = Gable Roof Area Negative Zone 1 Negative Zone 2 Negative Zone 3 Positive All Zones Overhang Zone 2 Overhang Zone 2 Parapet GCp+/- GCpi Surface Pressure (psf) User Input 10 at 50 at 100 at 10 at . 50 sf 100 sf 26 sf 56 sf -1.45 -1.38 -1.35 -55.2 -52.5 -51.4 -53.6 -52.3 -2.25 -1.90 -1.75 -85.6 -72.3 -66.6 -77.7 -71.4 -3.15 -2.73 -2.55 -119.9 -103.9 -97.0 -11 OA -102.8 1.05 0.91 0.85 40.0 34.6 32.3 36.8 34.3 -2.20 -2.20 -2.20 -83.7 -83.7 -83.7 -83.7 -83.7 .3.70 -2.86 -2.50 -140.8 -108.9 -95.1 -121.8 -106.6 Overhang pressures In the table above assume an Internal pressure coenlclent tOcp1) of U.0 Overhang soffit pressure equals adj wall pressure (which includes internal pressure of 18.5 psf) qp = 0.0 pelf CASE A = pressure towards building (pos) CASE B = pressure away from bldg (neg) Walls Area Negative Zone 4 Negative Zone 5 Positive Zone 4 & 5 Solid Parapet Pressure Surface Pressure s Userinput '10 elf I 100 elf I 500 elf I 40 at :ASE A: Interior zone: Corner zone: 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 ;ASE B: Interior zone: Corner zone: 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 +-GCpi Su ace Pressure ps) Userinput 0 at 500 sf 10 sf 100 sf 500 at 50 sf 120 sf E1.55-l'.37 .47 -1.35 -62.8 -56.1 -51.4 -58.1 -55.5 .60 -1.35 -74.2 -60.8 -51.464.8 -59.7 1.25 59.0 52.3 47.6 54.3 51.7 Ebbstone, Inc. JOB TITLE 4006 Avenue P 1125 NE 125th Street, Suite 503 Category 5 Hurricane Calculations North Miami, Florida 33161 JOB NO. SHEET NO. 850-544-1402 CALCULATED BY JR DATE 1120/20 754-222-9155 CHECKED BY JFS DATE 1/23120 Ultimate Wind Pressures Roofs w/ 6 5 10* and all walls h>60' Monoslope roofs 10°<6530° h 5 60' & aft design h<90' Location of C&C Wind Pressure Zones Walls h <_ 60' Gable, Sawtooth and & all design h<90' Multispan Gable 6 5 7 degrees & Monoslope 5 3 degrees h <_ 60' & all design h<90' Multspan Gable & Hip 7° < e 5 27' Gable 7° <05 45' Stepped roofs e 5 3° h 5 60' & sit design h<90' 02' I u Monoslope roofs 3°<0510, h 5 60' & all design h<90' Sawtooth 10* <0 5 45` It 5 60' & Bit design h<90' Ebbstone, Inc. Jae TITLE 4006 Avenue P 1125 NE 125th Street, Suite 503 Category 5 Hurricane Calculations North Miami, Florida 33161 JOB NO. SHEET NO. 850-544-1402 CALCULATED BY JR DATE 1/20/20 754-222-9155 CHECKED BY JFS DATE 1123/20 Roof Design Loads Items Description Multiple I psf (max) psf (min) Roofing Wood Shingles 3.0 2.0 Roofing 3 ply felt & gravel 5.5 5.0 Framing Wood Trusses @ 24" 3.0 2.5 Insulation R-30 Fiberglass insul. x 2.0 1.8 1.8 Ceiling 5/8" gypsum 2.8 2.5 Mach & Elec Mach. & Elec. 2.0 0.0 Misc. Misc. 0.5 0.0 0.0 0.0 Actual Dead Load O 18.6 C 13.8 Use this DL instead* 20.0 • 9.0 Live Load 20.0 0.0 Snow Load 0.0 0.0 Ultimate Wind (zone 2 - 100sf) 32.3 -66.6 Loading D + Lr 40.0 - D+0.75(0.6'W+Lr) 49.6 - OVD+0.6'W - -34.6 LRFD Loading 1.2D+1.6 Lr +O.SW 72.2 - 1.2D+1.OW+0.51-r 66.3 - 0.9D+1.OW - -58.5 Roof Live Load Reduction Roof angle 4.00 / 12 18.4 deg 0 to 200 sf: 20.0 psf 200 to 600 sf: 24 - 0.02Area, but not less than 12 psf over 600 sf: 12.0 psf 300 sf 18.0 psf 400 sf 16.0 psf 500 sf 14.0 psf User Input: 450 sf 15.0 psf e Ebbstone, Inc. 1125 NE 125th Street, Suite 503 North Miami, Florida 33161 850-544-1402 754-222-9155 JOB TITLE 4006 Avenue P Category 5 Hurricane Calculations JOB NO. SHEET NO. CALCULATED BY JR DATE 1/20120 CHECKED BY JFS DATE 1/23/20 Floor Design Loads Items IDescription Multiple psf(max) psf(min) Flooring Sheet vinyl x 1.0 1.5 0.5 Flooring Thin Set Tile 4.0 3.0 Insulation R-19 Fiberglass insul. 0.6 0.6 Decking 3/4" plywood/OSB 2.7 2.3 Ceiling 5/8" gypsum 2.8 2.5 Roofing Asphalt Shingles w/roll roofing 3.0 2.0 None 0.0 0.0 None 0.0 0.0 Misc. Misc. 0.5 0.0 Actual Dead LoadD 15.1 10.9 Use this DL instead* 100.0 65.0 15.0 0.0 Partitions Live Load 50.0 0.0 _____ Total Live Load 65.0 ___ 0.0 165.0 65.0 Total Load FLOOR LIVE LOAD REDUCTION (not including partitions) NOTE: Not allowed for assembly occupancy or LL>100psf or passenger car garages, except may reduce columns 20% if 2 or more floors & non -assembly L=Lo(0.25+15/4KLLAT) Unreduced design live load: Lo = 50 psf Floor member & 1 floor cols KLL = 2 Tributary Area AT = 300 sf Reduced live load: L = 43.1 psf Columns (2 or more floors) KLL = 4 Tributary Area AT = 500 sf Reduced live load: L = 29.3 psf IBC alternate procedure Smallest of: R= .08%(SF - 150) R= 23.1(1+D/L) = 69.3% R= 40% beams; 60% columns R = 12.0% Reduced live load: L = 44.0 psf R = 28.0% Reduced live load: L = 36.0 psf Ebbstone, Inc. Joe TITLE 4006 Avenue P 1125 NE 125th Street, Suite 503 Category 5 Hurricane Calculations North Miami, Florida 33161 JOB NO. SHEET NO. 850-544-1402 CALCULATED BY JR DATE 1/20/20 754-222.9155 CHECKED BY JFS DATE 1/23/20 Wall Design Loads Items Description Multiple psf (max) psf (min) 0.0 0.0 Sheathing 518" gypsum 2.8 2.5 Framing 2x4 wood stud @ 16" 1.3 0.8 Sheathing Plaster per 1" 8.0 6.0 veneer 4" Glass Block x 0.38 6.8 6.0 Insulation R-11 Fiberglass insul. 0.4 0.4 Mach & Elec Mach. & Elec. 1.0 0.0 Misc. Misc. 0.5 0.0 Actual Dead Load 01 20.7 15.6 Use this DL instead 01 55.0 • 50.0 Wall Design Loads Items iDescription Multiple I psf (max) psf (min) Framing 2x4 wood stud @ 16" 1.3 0.8 Insulation R-19 Fiberglass insul. 0.6 0.6 0.0 0.0 Sheathing 518" plywood/OSB 2.2 1.8 Wall Covering Solid Flat Tile on 1" mortar bi x 0.38 8.6 7.5 0.0 0.0 0.0 0.0 0.0 0.0 Actual Dead Load 0 12.7 O 10.7 Use this DL instead 50.0 O 40.0 ROOF UPLIFT AND WALL FLEXURE CALCULATIONS Ebbstone, Inc. JOB TITLE 4006 Avenue P 1125 NE 125th Street, Suite 503 Category 5 Hurricane Calculations North Miami, Florida 33161 JOB NO. SHEET NO. 850-544-1402 CALCULATED BY JR DATE 1/20/20 754-222-9155 CHECKED BY JFS DATE 1/23/20 W= Theta Pitch heta H = H He= L= H L Slab Span length W Reinforced Slab Truss Spacing End Zone Dead Load 0.6 Width of End Zone= 2a Roof slab size where a = lesser of 10% of least horizontal dimension or = 40 % of eave height 2.4 or 6.8 2.4 But not less than 40% of least horiz. Dim or 3 feet 9.6 or 3.00 3 a= (edge trip) =0 End Zone = 2a= 6 Roof Truss Wind Pressure From Component and Cladding Middle -52.3 Windward roof load zone 1 Edge -71.4 LeeWard roof load Zone 2 Corner -102.8 Windward Overhang Zone3 -411 R2= -931 plf R1= -1107 plf 24 ft Bldg. width least dimension 18.43 A Degree 4/12 Pitch H/W 17 Eave 21.00 Mean Roof height 38 ft Long dimension ft 0 psf "topping' 2 ft. 0 psf 0 inch Arm1 Arm2 Arm3 19 6 -1862 Total both ends -2215 Total both ends (Controls) Arm4 1 12 ROOF UPLIFT AND WALL FLEXURE CALCULATIONS E ibs e, Inc. ROOF UPLIFT AND SHEAR WALL CALCULATIONS PAGE 2 OF 2 Engineer: Jacques Registe Project: 4006 Avenue P DATE: 3/16/20 SHEAR WALLS Lateral on End Walls Assume that roof diaphragm carry load of 1/2 wall height + full roof height Roof height "rh" = W/2 * Pitch = 24.0 rd= 24.0 d= 2.00 ' 2a= 6 rd H= 17 H/2= 8.5 M W 1.2a en—dzbne Horizontal windward (MWF) "p" = 39.6 psf Horizontal leeward (MWF) "pl" = 26.3 psf ww force = A*p = 2256 lbs. Iw force =AI*pl 9846 lbs. Total Force = 12102 lbs. Check Roof Truss for Uplift Load Sum of Perforated Shear wall Lengths = 10.00 ft. Shear Capacity Adjustment Factor for wood framing only Table.4.3.3.5, NDS 2015 0.69 Unit Shear of Wall (Tbl 1 APA p.7) 530 lbs. per ft. :15/32", 2" thick, 8d nails @ 4" at corners; Check the unit shear wall strength OK T=C= 0 lbs. Moment F*H/2 = 102863 ft-lbs Walls 1=1/12bhA3 0 in^4 GENERAL 1. CONSTRUCTION IS TO COMPLY WITH THE REQUIREMENTS OF THE GOVERNING BUILDING CODE AND ALL OTHER APPLICABLE FEDERAL, STATE. LOCAL CODES, STANDARDS, REGULATIONS AND LAW. THE GOVERNING CODE FOR THIS PROJECT IS THE. FLORIDA BUILDING CODE 2017 (EXISTING BUILDING). 2. THE STRUCTURE IS DESIGNED TO BE STRUCTURALLY SOUND MEN COMPLETED. PRIOR TO COMPLETION. THE CONTRACTOR IS RESPONSIBLE FOR STABILITY AND TEMPORARY BRACING OR SUPPORT. 3. DESIGN SUPERIMPOSED LOADS BUILDING LIVE LOAD--------- 40 PSF ROOF UVE LOAD 20 PSF DECK LOAD--------------100 PSF 4. DESIGN WIND LOADS GOVERNING CODE -------------------- ASCE 7-10 ULTIMATE DESIGN WIND SPEED 158 MPH NORMAL WIND SPEED ------------------- V=123 MPH RISK CATEGORY III IMPORTANCE FACTOR ------------------ 1-1.0 EXPOSURE—MWFRS------- B CLADDING AND COMPONENT--B INTERNAL PRESSURE COEFFICIENT--GCP+/-0.55 (ENCLOSED) MEAN ROOF HIGH 19.5 FEET WIND DIRECTIONAL FACTOR --- KE= 0.85 TOPOGRAPHY FACTOR ------- 1.0 5. VERIFY ALL DIMENSIONS AND SITE CONDITIONS PRIOR TO START OF CONSTRUCTION. NOTIFY THE ARCHITECT/ENGINEER OF ANY DISCREPANCIES OR INCONSISTENCIES. NO CHANGES OF INFORMATON SHOWN ON THE DRAWINGS SHALL BE MADE WITHOUT THE SPECIFIC WRITTEN APPROVAL OF THE ARCMITECT/ENGINEER. DESIGN INFORMATON SHOWN ON THE DRAWINGS PROVIDE OVERALL DIMENSIONAL PARAMETERS AND DESCRIBE ELEMENTS TO BE CONSTRUCTED. THE CONTRACTOR SMALL ADJUST DIMENSIONS AND DETAILS AS REQUIRED TO FIT EXISTING CONDITIONS. THE ARCHITECT/ENGUNEER SHALL BE NOTIFIED OF ANY PROPOSED MODIFICATIONS. 6. DETAILS LABELED 'TYP' APPLY TO ALL SITUATIONS THAT ARE THE SAME OR SIMILAR TO THOSE SPECIFICALLY REFERENCED. WEATHER OR NOT THEY ARE KEYED IN AT EACH LOCATION. QUESTION REGARDING THE APPLICABILITY OF TYPICAL DETAILS SHALL BE RESOLVED BY THE ENGINEER_ WINDOW C(`HFDI II F 1) ALL WINDOWS SHALL MEET THE WIND PRESSURE SHOWN ON THIS SHEET SCOPE OF WORK: 1) REPLACE 1 - WINDOW 2) REPAIR BATHROOMS 3) INSTALL KITCHEN SINK AND COUNTER TOP 4) REPAIR SIDING 5) REPAIR STAIRWAY AND DECK ALL REPAIRS SHALL BE DONE PER THE DETAILS SHOWN IN THIS SET OF PLANS. ` COMPLIANCE METHOD LEVEL 3 NO ALTERATION TO TEH EXISTING ELETRICAL OR PLUMBING SYSTEM. CONNECTORS I. ALL CONNECTORS AND FASTENERS SHALL BE GALVANRED UNLESS OTHERWISE NOTED. 2. CONTRACTOR SHALL USE ALL FASTENERS REQUIRED TO OBTAIN MAXIMUM PUBLISHED CONNECTOR LOADS UNLESS OTHERWISE NOTED. 3. CONTRACTOR SHALL INSTALL ALL CONNECTORS IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATONS. DIMENSIONAL LUMBER (NEWT L ALL LUMBER SHALL CONFORM TO AMERICAN SOFTWOOD LUMBER STANDARD PS-20. 2, MATERIAL SHALL BE SOUTHERN PINE, COMPLYING WITH THE FOLLOWING MIN. ALLOWABLE STRESS LIGHT FRAMING --------------- Fb (BENDING) 1500 PSI (2X2 THROUGH 4X4) E. 1.600.000 PSI BEAMS AND STRINGERS ---------- Fb (BENDING) 975 PSI POSTS AND TIMBERS Fb (BENDING) 850 PSI (5X5 AND LARGER) INDEX OF DRAWINGS S-1 GENERAL NOTES S-2 FLOOR LAYOUT S-3 EXISTING HOUSE ELEVATION S-4 FOUNDATION LAYOUT S-5 STAIRS AND DECK DETAILS S-6 CONNECTION DETAILS S-7 INTERIOR REPAIR PLANS IACOUES REGI$TE, P£. P.E. LICENSE NUMBER 43397 EBBAONE. INC. 3370 CAPRAL CIRCLE NE. SURE 1 O 5 4 4 5 5 OLTW2 0 XIN WIND MBSUPE5 OI M $ONE EiTEC1Ih WIND MG ID SF 1. ss I (Rmr IT wo/-xi m/" 2 (ROOF i) •¢0/-646 ss-1/-656 3 (RWF 3) IpD/-II99 R]/-U. s LWut s) ss.o/-7•� s2.1/-Wa 7-10 COMPONENT AND CLADDING DESIGN PRESSURES NOTE: ULTIMATE WIND PRESSURE FROM ASCE 2-10 WAS USED. COVERSION FACTOR OF 0.6 USING ASD CAN BE USED FOR WNDOWS SPECIFICATIONS. GENERAL NOTES RENOVATION PLANS 4006 Avenue P, For[ Pierce FIDTIda 6-X6• Columns (TYP) III III III III III III III ^ III III Ex. 2XB JOIST 0 1 III III III III III III III III III III III III III R III III N— 2X8 JOIST 0 I III - ___------ II III III 4----_____ III III III III SIMPSON STRONG 11 III III III 4 M25A @ JOIST/BE III III III INTERSECTION Rt III 6'X6' Columns III B III lu (TYP! III III III III III III _ _ Ju III III III III ul III z-zxlB 2 - 2XIO ITYP1 III III III III III III III III III IPXW Columns III "') 4-NEW 2X8 a 12'o.c. — EXISTING BEAM LAYOUT JACQUES REGISTE, P.E. Pi. LICENSE NUMBER I3397 EBBSTONE, INC. 3370 CAPITAL CIRCLE NE. SURE I 'A iIF Ir i III_ _ all _J I�L�I�II■I�I�I_ _!�I�ItII■I�I�I �I�I■II■I�I�I I�I�I�II�I�I�I IE �ii�iiu�i�ii w I�I�I�II■I�I�I I�I�I�II�I�I�I _I�I�I�!!■I�I�I=� I�lal�ll�l�l�l I�I�Il�il�l�l .�W�IW" I�I�I�II■I�I�I �I�I�II�L�I�II I.- 7—INSTALL FULL DEPTH BLOCKING ITYP3 r Ex. 2X8 JOIST 0 I6'O.C. ITYP1 EXISTING FLOOR JOIST LAYOUT FLOOR LAYOUT RENOVATION PLANS �wn� 4006 Avenue P, Fort Pierce Florida 1IW PT TRIM PLANK LAPPED BIDIND WODD POST C 8'X6 Post 6'X6' Post INDOW TO SIDE VIEW BE REPLACED N.T.S. i%A PTTRIM APPEDLANN LIPPED GIDIND FRONT VIEW EXISTING, HOUSE ELEVATION N.T.S. JACQUES USISTE, P.E. K.G. I-- EXISTING HOUSE ELEVATION P.E. LICENSE NUNBER 43 3B1 RENOVATION PLANS EBSSIDNE. INC. 3310 VYRAL CIRCLE NF, SURE 1 J.R. %-10 ..e Senn TUTANAssEE, a az3aB 4006 Avenue P, Fort Pierce Florida CEATIF![A!F OF AUTNOPIIATION 9391 /.a. 0]-10 Sd 6-W Columns (TYP) —— — ---------- �----u WINDOW TO BE REPLACED I II II IL—J1 STAIRS TO BE REPAIRED r06E0 RE R At D q I II I AT T E EP R I I e _ __— ZEE I I — I EXISF. LH Y _ENTRY ODOR KI E P T E i KITCHEN TO BE REPAIRED ` I 6 a - HATCHED AREA TO BE REPAIRED b _ _ 2 SLIDIND CLASS 00017S !EXIST.) _L ' II IIIII�II-ss I� I�I�III�IITIIII IIIIIIIIIIIIIIIIII '' �IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII I0'xW cPwmRs 6 �b P�I��IPI�Jr b I I I 'B''x'a' columns I I I I I I I I I rTYP) I I I I I ir�Pi I I I I I I I I I I I I I I Ell 11111111111M111111111 IIIIIIIIIIIIIIIIIIIII EXISTING FOUNDATION LAYOUT HATCHED AREA TO BE REPAIRED EXISTING HOUSE PLAN IACo.E1 RE66TF, P.F. *1'2B FOUNDATION LAYOUT P.E. OCME NuweFR A3391 RENOVATION PLANS EBBSIONE.INC. 33T0 CAPRAL CIRCLE NE, SUITE I TAUWASSEE, FL32308 0006 Avenue P, Fort Pierce Florida CERTIRCATE OF AUTHORIZATION 9393 S'A INSTALL )-p' D (H.D.C.) THRU BOLTS WITH NUTS AND WASHERS TO AT ALL JOIST k POST CONNECTIONS ��JY/j" 2X6 P.T. ///f/y//// 2%4 RAIL WIP WITH WITH NUT' m (H.DGI THRI BOLTS VITH NUTS AND VASTER'. I AT TOP 6 BDTiDN OF POST (TYP. 4"%4' P.T. STAUNCH 2"BEAMS SECURED WRN }tfl%B'XmG 0 WPSNERSIYP N EXISTING POSTS AND SOL I/B'm (HI 'T. U THROE WASHERS AT ALL JOSTT — EXISTING ADS ii PROPOSED STANTION DETAIL N.T.S. EXISTING STAIR DETAIL N.T.S. (TO BE REPAIRED) 2"%2" PICKETS 5-1/2"O.0 .TH A DO' CUT AT THE TOP AND THE BOTTOM ".2" PICKETS 5-1/2'O.C. WITH A 30' CUT AT THE 2"%6" TOP PLATE. KITH TOP AND THE BOTTOM A 1/q- OVER HANG THE OUTSIDE EDGE OE THE (21-3/e" m MRU BOLTS PILING, (SECURED WITH kfM ! AND WASHERS AT THE (2j-(H.D.G) SCREWS PER ,J TOP AND BOTTOM OF THE POST PILING) CONNED➢ONE 2"%4" RAIL WITH BEVELEEDGES 2" 98 (HDG)DSCREWS TVA. 0 %q" P.T. STANTON "%4" RAIL WITH 2"%6' P.T. JOSL GAP ABOVE DECKINGECKING (21-1/Ym THROE 6'-0" ttP 6'-0 TYP 2XIO WITH SISTWASHERA JOIST AT PILING CONNECTIONS I I I I SEE DETAIL 'A B"%8" POSTS (BEAM TO COLUMN CONNECTION) EXISTING GROUND 'I LI LI VIEW A -A PROPOSED DECK ELEVATION WITH RAILINGS JACOUES REGISTE, P.E. P.E. LICENSE NUMBER 13397 EBBSTONE. INC. 3370 CAPITAL CIRCLE NE, SURE I 2"4" DECKING 2'S P.T. - CROSS BEAM JOST (i R ) SECTION B-B (2)-NUAN m D. TH BOLTS LATH NUTS WASHERS TO AT ALL JOIST WW & P05i CONNECTIONS Su1PSON STRONG RE HB.SA ®. ' G E T / BE M' INTERSECTION (TYP.) (2)-$" 0 (TOO.) THROE BOLTS MATH NUTS AND WASHERS AT ALL Li BEAM TO POST CONNECTIONS (TYP.) --6"X6" POSTS WITH A MIN. DEPTH OF 6' BELOW NATURAL GRADES (AGO OF 2.5 LBS./IN) (ttP.) II 2 - 2XIB BEAMS 2X8 JOIST ADD 13/4'BOLT _ 2 - 2XIB BEAMS _ Eust SOL TS I I 8XB COLUMN DETAIL "A" N.T.S. (EXISTING BEAM TO COLUMN CONNECTION) STAIRS AND DECK DETAILS RENOVATION PLANS 4006 Avenue P, For[ Pierce Florida EXISTING GROUND -j NOTES 12 HURRICANE CLIPS ALL HORIZONTAL AND INCLINED MEMBERS THAT RECEIVE DECKING SHALL BE FRAMED AS A SHINGLE ROOF A WOOD STRUCTURAL PANEL DIAPHRAGMS. i FASTENERS SHALL BE GALVANIZED 10D ROOF RINGSNANK NAILS SPACED 4 O.C. AT PANEL RAFTERS 22'-0' DC. — — — — EXISTING PANEL EDGE NAILING IRECTION OF EDGES AND ENDS, AND 6' O.C. IN THE FIELD INSULATION IOD ® 4 O.C. FACE GRAIN OF THE PANEL. METAL GRIP ��� JOISTS BLOCKING SHALL BE PROVIDED AT ALL PANEL EDGES, BE THE SAME SIZE AS THE JOIST, AND INSTALLED IN FULL DEPTH ORIENTATION (00 NOT LAY FLAT). SUPPORTED PANEL SPACE PLYWOOD BUTT JOINTS +' USING 16D GALV. TIEDOWN STRAP HE AT EDGE NAILING BRIGHT COMMON -NAIL AS TEMPORARY SPACER. EACH RAFTER WITHIN FIELD NAILING AT INTERMEDIATE SUPPORTS 0\FLOOR SHEATHING DETAILS l LOP ® BOITOM/ 2XB OR 2X6 BEAMS V1 i+ HT2NTER.5 01111TSECTIONS Simpson Strong -Tie Simpson Strong -Tie m LSTA18 HE HS Simpson Strong -Tie REINFORCEMENT AT ROOF/WALL AND FLOOR CONNECTION P.E. LICENSE NUMBER 43397 EBWONE, INC. 3370 C09AL CIRCLE NE: SURE I TALLAHASSEE, FL 3Z308 CERTIFICATE OF AUTHORIZATION 9292 SIMPSON LSTA18 (HOT -DIPPED GALV.) TIE DOWN STRAP AT EACH STUD (OUTSIDE FACE) TO RESIST UPLIFT. R-19 TO BE INSTALLED 2' X e' 16' 0C. 2' X B' BLOCKING PROPOSED 3/8' COX PLYWOOD INSTALL TIE DOWN 5 v_ 2_ 2 R 10 BEAMS SECURED 'TO ISIMPSONNSTALL STRAP M2.G HL�—f — PILING WITH AM 5/8'0 X 1A' TYP THROUGH OUT I Go. MACH. BOLTS WITH NUT AND WASHERS TYP. ^�� r EXIST. 10-0 PILING III// I 15' DEPTH (TYP) CONNECTION DETAILS RENOVATION PLANS 4006 Avenue P. Fort Plerce Florida :L IryryII',�I—II--_� WINDOW TO I BE REPLACED BEDROOM BEDROOM n IIII I CONSr. SHOWER II II II p -�--] rz II ) i INSTA LVANI YE M BEDROOM ® L O INSTALL VANITY & uJ I CONST.ORYNALI. B; o I INSTALL CABINET& —__ LIVING AREA II rxe Columns rrYP1 INSIDE RENOVATION PLAN IACOUES REOISTE, P.1, I; G. Oi-2 INTERIOR flEPNF PLANS PS. ucEx9f rvuxeER 4339) FENOVATION PLANS REGISTE, SDOER ENGINEERING. INC. JA. 0)-I0 3330 CAPITAL GIRLIE NE. SURE l l X. 01 , TqL SEF. FL 3:399 4006 Avenue P, Fort Pierce Florida CERTIFICATE OF AVTNORIZATION 9292 F.R. 01OP]0 9'>