REVIEW COMMENTS
I
PROPERTY INFORMATION
Address: 4006 Avenue P Owner(s):
Jacques Registe
City / State / Zip: Fort Pierce, FI 34947
Parcel #: 2405-601-0306-000/9 Jurisdiction: SAINT LUCIE COUNTY
Zoning: RS-4 Lot#: 18 Block: 16
APPLICATION INFORMATION
Permit Number: 1912-0389 Stories: Automatic Sprinkler System? No
Permit Type: BUILDING RESIDENTIAL RENOVATLqN_
CONTRACTOR INFORMATION
Contractor Name: Fax mber:
Business Name:
Business Addr:
City / State / Zip:
REVIEWS AND COMMENTS
Review Tvpe Status Reviewed By Date Completed Date Released
FRONT COUNTER REVIEW COMPLETE Deanna Givens 1211912019 12/1912019 1211912019
Comment:
[ PE REVIEW COMMENTS (2) INCOMPLETE Jpi, Inc -Andrew 1/17/2020
Comment: 1).PLEASE SEE THE FLORIDA BUILDING CODE, EXISTING AND CLASSIFY THE LEVEL OF WORK. (CH5)
12/19/2019 PROVIDE THE COMPLIANCE METHOD. (CH3)
PHOTOS INDICATE 100% OF THE FLOOR SYSTEM WAS CHANGED.
Comment: 2) PLEASE PROVIDE A COMPLETE SET OF PLANS FOR REVIEW: ([A] 107.2.1)
A) STRUCTURAL FLOOR FRAMING PLAN, ALL MEMBER SIZES & CONNECTIONS
1211912019 B) FLOOR PLAN WITH ROOMS LABELED & EGRESS SHOWN.
C) LOCATE PLUMBING FIXTURES, APPLIANCES, ELEC. METER.
D) ELECTRICAL PLAN, COMPLIANT WITH SECTION (808.3) INCLUDE LOCATION OF SMOKE ALARMS. (703.2)
E) PLANS & SPECIFICATIONS SHOWING THE EXTENT OF PLUMBING WORK.
Comment: 3) PLEASE PROVIDE AN ENGINEERING EVALUATION AND ANALYSIS THAT ESTABLISHES THE STRUCTURAL
12/19/2019 ADEQUACY OF THE ALTERED STRUCTURE- SHALL BE PREPARED BY A REGISTERED DESIGN
PROFESSIONAL AND SUBMITTED TO THE CODE OFFICIAL. ([BS] 907.4.1) INCLUDE THE LATERAL LOAD -
RESISTING SYSTEM. ([BS] 907.4.2)
12119/2019 Comment: 4) ALTERATIONS SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE, ENERGY
CONSERVATION. NO INFORMATION PROVIDED FOR INSULATION. (908.1)
12(19/2019 Comment: 5) PLEASE PROVIDE PRODUCT APPROVALS FOR ALL PROPOSED COMPONENTS & CLADDING (WINDOW).
(707.4)
12/19/2019 Comment: 6) PLEASE PROVIDE A COMPLETE DETAIL FOR THE ALTERED AREAS OF THE BUILDING ENVELOPE. ([A]
107.2.1)
12120/2019 Comment: 7) IT IS UNCLEAR THE EXTENT OF MECHANICAL WORK PERFORMED IF ANY. ([A] 107.2.1)
�417/2020 Comment: "COMMENTS BELOW ARE FROM PLANS EMAILED FROM THE OWNER ON 1/16/20, JACQUES REGISTE."
1117/2020 Comment: "9) STRUCTURAL DRAWINGS RECEIVED. ALL WORK ON THE BUILDING WILL NEED TO BE DOCUMENTED
ON THE PLANS.—
JG, lLLGTC/ (/(1LFiL�M
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL 34982
REVIEW COMMENTS
1/1712020
Comment:
"10) PLEASE SEE SECTION 301.1 OF THE FL BUILDING CODE EXISTING, NOTATE ON THE PLANS WHICH
COMPLIANCE METHOD WILL BE USED."
Comment:
"l1) PLEASE SEE SECTION 501.1 OF THE FL BUILDING CODE EXISTING, NOTATE ON THE PLANS WHAT
111712020
THE LEVEL OF ALTERATION IS. BASED ON THE PHOTO ATTACHED FROM THE CODE OFFICER, WE
BELIEVE THIS IS A LEVEL 3 ALTERATION, WORK AREA EXCEEDS 50 PERCENT OF THE BUILDING AREA.-
1/17/2020
Comment:
" 12) THE BEAM AND JOIST LAYOUTS WILL NEED TO BE RE -LABELED AS 'NEW'. ALL MEMBER SIZES &
CONNECTIONS WILL NEED TO BE SPECIFIED."
1/1712020
Comment:
"13) ALL BUILDING DEPARTMENT COMMENTS WILL NEED TO BE ADDRESSED."
PLANS EXAMINER REVIEW COMPLETE Jpi, Inc -Andrew 12/1912019 1/1712020 111M020
Comment:
Planning 8. Development Services
Building & Code Regulation Division
2300 VtrginlaAvenuo
Fort Pierce, FL 34982
PROPERTY INFORMATION
Address: 4006 Avenue P
City / State / Zip: Fort Pierce, FI 34947
Parcel#: 2405-601-0306-000/9
Zoning: RS4
APPLICATION INFORMATION
REVIEW COMMENTS
Owner(s):
Jacques Registe
Jurisdiction: SAINT LUCIE COUNTY
Lot#: 18 Block: 16
1
Permit Number: 1912-0389 Stories: Automatic Sprinkler System? No
Permit Type: BUILDING RESIDENTIAL RENOVATION
CONTRACTOR INFORMATION
Contractor Name: Fax Number:
Business Name:
Business Addr: Email:
City / State / Zip:
REVIEWS AND COMMENTS
Review Type Status Reviewed By Date Started Date Completed Date Released
FRONT COUNTER REVIEW COMPLETE Deanna Givens 12/1912019 1211912019 12/19/2019
Comment:
PE REVIEW COMMENTS (2) INCOMPLETE Jpi, Inc -Andrew 1/1712020
Comment: 1) PLEASE SEE THE FLORIDA BUILDING CODE, EXISTING AND CLASSIFY THE LEVEL OF WORK.
12/1912019 (CH5) PROVIDE THE COMPLIANCE METHOD. (CH3)
PHOTOS INDICATE 100%OF THE FLOORSYSTEMWAS CHANGED.
Based -on -the photo -provided -the Compliance method -is -level 3
12/1912019 Comment:
2) PLEASE PROVIDE A COMPLETE SET OF PLANS FOR REVIEW: ([A] 107.2.1)
A) STRUCTURAL FLOOR FRAMING PLAN, ALL MEMBER SIZES & CONNECTIONS
B) FLOOR PLAN WITH ROOMS LABELED & EGRESS SHOWN.
C) LOCATE PLUMBING FIXTURES, APPLIANCES, ELEC. METER.
D) ELECTRICAL PLAN, COMPLIANT WITH SECTION (808.3) INCLUDE LOCATION OF SMOKE
ALARMS. (703.2)
12I19/2019
Signed and sealed Structural Plans is included for your review. No electrical plans as the
existing
Electrical system was not altered.
E) PLANS & SPECIFICATIONS SHOWING THE EXTENT OF PLUMBING WORK.
Plumbing work in the bathroom and kitchen is minimal and areas are shown in the plans
Comment:
3) PLEASE PROVIDE AN ENGINEERING EVALUATION AND ANALYSIS THAT ESTABLISHES THE
STRUCTURAL ADEQUACY OF THE ALTERED STRUCTURE- SHALL BE PREPARED BY A
REGISTERED DESIGN PROFESSIONAL AND SUBMITTED TO THE CODE OFFICIAL. ([BS] 907.4.1)
INCLUDE THE LATERAL LOAD -RESISTING SYSTEM. ([BS] 907.4.2)
]�
Signed and sealed structural analysis is attached for your reviews
/rn f.61(illi (J01=
REVIEW COMMENTS
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce; FL U982
Page 2
12/19/2019 Comment: 4) ALTERATIONS SHALL COMPLY WITH THE REQUIREMENTS OF THE
FLORIDA BUILDING CODE, ENERGY
CONSERVATION. NO INFORMATION PROVIDED FOR INSULATION. (908.1)
Insulation of floor and exterior wall will be provided per the plans
12/19/2019 Comment:
5) PLEASE PROVIDE PRODUCT APPROVALS FOR ALL PROPOSED
COMPONENTS $ CLADDING (WINDOW).
(707.4)
Product approval is included in the plans
12/19/2019 Comment:
6) PLEASE PROVIDE A COMPLETE DETAIL FOR THE ALTERED AREAS OF THE
BUILDING ENVELOPE. ((A]
Areas altered are shown in the plans
107.2.1)
12/20/2019 Comment:
7) IT IS UNCLEAR THE EXTENT OF MECHANICAL WORK PERFORMED IF ANY.
([A] 107.2.1)
P,
No mechanical work is planned. Once all other work is complete, we
will hire A HVAC contractor
P
To install a Heat Pump Unit. They will acquire permit at that time.
1/17/2020 Comment:
"COMMENTS BELOW ARE FROM PLANS EMAILED FROM THE OWNER ON
1/16/20, JACQUES REGISTE."
Noted
S��EtGJL GotfitG j "�
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
FortPierce, FL 34982
REVIEW COMMENTS
1/17/2020 Comment: "9) STRUCTURAL DRAWINGS RECEIVED. ALL WORK ON THE BUILDING WILL NEED TO BE
DOCUMENTED ON THE PLANS."
All work is shown in the plans
3
1117/2020 Comment:
" 10) PLEASE SEE SECTION 301.1 OF THE FL BUILDING CODE EXISTING, NOTATE ON THE PLANS
WHICH COMPLIANCE METHOD WILL BE USED."
Compliance method level 3 alteration will be used
Comment:
"11) PLEASE SEE SECTION 501.1 OF THE FL BUILDING CODE EXISTING, NOTATE ON THE PLANS WHAT
1/17/2020
THE LEVEL OF ALTERATION IS. BASED ON THE PHOTO ATTACHED FROM THE CODE OFFICER, WE
BELIEVE THIS IS A LEVEL 3 ALTERATION, WORK AREA EXCEEDS 50 PERCENT OF THE BUILDING AREA."
Yes level 3 alteration has been used
1/17/2020
Comment: "12) THE BEAM AND JOIST LAYOUTS WILL NEED TO BE RE -LABELED
AS'NEW . ALL MEMBER SIZES & CONNECTIONS WILL NEED TO BE
SPECIFIED."
All members have been relabeled new or existing
1/17/2020
Comment: "13) ALL BUILDING DEPARTMENT COMMENTS WILL NEED TO BE
ADDRESSED."
Noted
PLANS EXAMINER REVIEW COMPLETE Jpi, Inc -Andrew 12/1912019
1/1712020 1117/2020
Comment:
�j rrcro Goratx�
Planning A Development Services
Building 9 Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL 34982
REVIEW COMMENTS
1
PROPERTYINFORMATION
Address: 4006 Avenue P
City / State / Zip: Fort Pierce, FI 34947
Parcel #: 2405-601-0306-000/9 Jurisdiction:
Zoning: RS-4 Lot#:
APPLICATION INFORMATION
Permit 1912-0391 Stories:
Number: BUILDING (MISCELLANEOUS)
Permit
Type:
CONTRACTOR INFORMATION
Contractor Name:
Business Name:
Business Addr:
City / State / Zip:
Owner(s):
Jacques Registe
SAINT LUCIE COUNTY
16 Block: 16
Automatic Sprinkler System? No
Fax Number:
Email:
REVIEWS AND COMMENTS
Review Type Status Reviewed By Date Started Date Completed Date Released
FRONT COUNTER REVIEW COMPLETE Karen Nielsen 1211912019 12119/2019 12/19/2019
Comment:
PLANS EXAMINER REVIEW INCOMPLETE Jpi, Inc -Andrew 12119/2019
Comment: 1) PLEASE SEE THE FLORIDA BUILDING CODE, EXISTING AND CLASSIFY THE LEVEL OF WORK. (CH5)
12120/2019 PROVIDE THE COMPLIANCE METHOD. (CH3)
Compliance method is level 3
Comment: 2) PLEASE PROVIDE A COMPLETE SET OF PLANS FOR REVIEW:
12120/2019 A) STRUCTURAL FLOOR FRAMING PLAN, ALL MEMBER SIZES & CONNECTIONS.
B) DETAIL FOR HOUSE TO DECK CONNECTION.
A set of Plans is attached
12/20/2019
Comment: 3) PLEASE PROVIDE AN ENGINEERING EVALUATION AND ANALYSIS THAT ESTABLISHES THE
STRUCTURAL ADEQUACY OF THE ALTERED STRUCTURE- SHALL BE PREPARED BY A REGISTERED DESIGN
PROFESSIONAL AND SUBMITTED TO THE CODE OFFICIAL. ([BS] 907.4.1) INCLUDE THE LATERAL LOAD -RESISTING
SYSTEM. ([BS] 907.4.2)
12/20/2019 Comment: 4) A DESIGN PROFESSIONAL IS REQUIRED FOR THIS PERMIT. ([A] 107.1)
A__.' Signed and sealed plans attached
ZONING REVIEW PENDING
Comment: