Loading...
HomeMy WebLinkAboutReview CommentsJl� /�rrGfli (/QG£lcus �` Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL M82 REVIEW COMMENTS I PROPERTY INFORMATION Address: 4006 Avenue P Owner(s): Jacques Registe City / State / Zip: Fort Pierce, FI 34947 Parcel #: 2405-601-0306-000/9 Jurisdiction: SAINT LUCIE COUNTY Zoning: RS-4 Lot#: 18 Block: 16 APPLICATION INFORMATION Permit Number: 1912-0389 Stories: Automatic Sprinkler System? No Permit Type: BUILDING RESIDENTIAL RENOVATLqN_ CONTRACTOR INFORMATION Contractor Name: Fax mber: Business Name: Business Addr: City / State / Zip: REVIEWS AND COMMENTS Review Tvpe Status Reviewed By Date Completed Date Released FRONT COUNTER REVIEW COMPLETE Deanna Givens 1211912019 12/1912019 1211912019 Comment: [ PE REVIEW COMMENTS (2) INCOMPLETE Jpi, Inc -Andrew 1/17/2020 Comment: 1).PLEASE SEE THE FLORIDA BUILDING CODE, EXISTING AND CLASSIFY THE LEVEL OF WORK. (CH5) 12/19/2019 PROVIDE THE COMPLIANCE METHOD. (CH3) PHOTOS INDICATE 100% OF THE FLOOR SYSTEM WAS CHANGED. Comment: 2) PLEASE PROVIDE A COMPLETE SET OF PLANS FOR REVIEW: ([A] 107.2.1) A) STRUCTURAL FLOOR FRAMING PLAN, ALL MEMBER SIZES & CONNECTIONS 1211912019 B) FLOOR PLAN WITH ROOMS LABELED & EGRESS SHOWN. C) LOCATE PLUMBING FIXTURES, APPLIANCES, ELEC. METER. D) ELECTRICAL PLAN, COMPLIANT WITH SECTION (808.3) INCLUDE LOCATION OF SMOKE ALARMS. (703.2) E) PLANS & SPECIFICATIONS SHOWING THE EXTENT OF PLUMBING WORK. Comment: 3) PLEASE PROVIDE AN ENGINEERING EVALUATION AND ANALYSIS THAT ESTABLISHES THE STRUCTURAL 12/19/2019 ADEQUACY OF THE ALTERED STRUCTURE- SHALL BE PREPARED BY A REGISTERED DESIGN PROFESSIONAL AND SUBMITTED TO THE CODE OFFICIAL. ([BS] 907.4.1) INCLUDE THE LATERAL LOAD - RESISTING SYSTEM. ([BS] 907.4.2) 12119/2019 Comment: 4) ALTERATIONS SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE, ENERGY CONSERVATION. NO INFORMATION PROVIDED FOR INSULATION. (908.1) 12(19/2019 Comment: 5) PLEASE PROVIDE PRODUCT APPROVALS FOR ALL PROPOSED COMPONENTS & CLADDING (WINDOW). (707.4) 12/19/2019 Comment: 6) PLEASE PROVIDE A COMPLETE DETAIL FOR THE ALTERED AREAS OF THE BUILDING ENVELOPE. ([A] 107.2.1) 12120/2019 Comment: 7) IT IS UNCLEAR THE EXTENT OF MECHANICAL WORK PERFORMED IF ANY. ([A] 107.2.1) �417/2020 Comment: "COMMENTS BELOW ARE FROM PLANS EMAILED FROM THE OWNER ON 1/16/20, JACQUES REGISTE." 1117/2020 Comment: "9) STRUCTURAL DRAWINGS RECEIVED. ALL WORK ON THE BUILDING WILL NEED TO BE DOCUMENTED ON THE PLANS.— JG, lLLGTC/ (/(1LFiL�M Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 REVIEW COMMENTS 1/1712020 Comment: "10) PLEASE SEE SECTION 301.1 OF THE FL BUILDING CODE EXISTING, NOTATE ON THE PLANS WHICH COMPLIANCE METHOD WILL BE USED." Comment: "l1) PLEASE SEE SECTION 501.1 OF THE FL BUILDING CODE EXISTING, NOTATE ON THE PLANS WHAT 111712020 THE LEVEL OF ALTERATION IS. BASED ON THE PHOTO ATTACHED FROM THE CODE OFFICER, WE BELIEVE THIS IS A LEVEL 3 ALTERATION, WORK AREA EXCEEDS 50 PERCENT OF THE BUILDING AREA.- 1/17/2020 Comment: " 12) THE BEAM AND JOIST LAYOUTS WILL NEED TO BE RE -LABELED AS 'NEW'. ALL MEMBER SIZES & CONNECTIONS WILL NEED TO BE SPECIFIED." 1/1712020 Comment: "13) ALL BUILDING DEPARTMENT COMMENTS WILL NEED TO BE ADDRESSED." PLANS EXAMINER REVIEW COMPLETE Jpi, Inc -Andrew 12/1912019 1/1712020 111M020 Comment: Planning 8. Development Services Building & Code Regulation Division 2300 VtrginlaAvenuo Fort Pierce, FL 34982 PROPERTY INFORMATION Address: 4006 Avenue P City / State / Zip: Fort Pierce, FI 34947 Parcel#: 2405-601-0306-000/9 Zoning: RS4 APPLICATION INFORMATION REVIEW COMMENTS Owner(s): Jacques Registe Jurisdiction: SAINT LUCIE COUNTY Lot#: 18 Block: 16 1 Permit Number: 1912-0389 Stories: Automatic Sprinkler System? No Permit Type: BUILDING RESIDENTIAL RENOVATION CONTRACTOR INFORMATION Contractor Name: Fax Number: Business Name: Business Addr: Email: City / State / Zip: REVIEWS AND COMMENTS Review Type Status Reviewed By Date Started Date Completed Date Released FRONT COUNTER REVIEW COMPLETE Deanna Givens 12/1912019 1211912019 12/19/2019 Comment: PE REVIEW COMMENTS (2) INCOMPLETE Jpi, Inc -Andrew 1/1712020 Comment: 1) PLEASE SEE THE FLORIDA BUILDING CODE, EXISTING AND CLASSIFY THE LEVEL OF WORK. 12/1912019 (CH5) PROVIDE THE COMPLIANCE METHOD. (CH3) PHOTOS INDICATE 100%OF THE FLOORSYSTEMWAS CHANGED. Based -on -the photo -provided -the Compliance method -is -level 3 12/1912019 Comment: 2) PLEASE PROVIDE A COMPLETE SET OF PLANS FOR REVIEW: ([A] 107.2.1) A) STRUCTURAL FLOOR FRAMING PLAN, ALL MEMBER SIZES & CONNECTIONS B) FLOOR PLAN WITH ROOMS LABELED & EGRESS SHOWN. C) LOCATE PLUMBING FIXTURES, APPLIANCES, ELEC. METER. D) ELECTRICAL PLAN, COMPLIANT WITH SECTION (808.3) INCLUDE LOCATION OF SMOKE ALARMS. (703.2) 12I19/2019 Signed and sealed Structural Plans is included for your review. No electrical plans as the existing Electrical system was not altered. E) PLANS & SPECIFICATIONS SHOWING THE EXTENT OF PLUMBING WORK. Plumbing work in the bathroom and kitchen is minimal and areas are shown in the plans Comment: 3) PLEASE PROVIDE AN ENGINEERING EVALUATION AND ANALYSIS THAT ESTABLISHES THE STRUCTURAL ADEQUACY OF THE ALTERED STRUCTURE- SHALL BE PREPARED BY A REGISTERED DESIGN PROFESSIONAL AND SUBMITTED TO THE CODE OFFICIAL. ([BS] 907.4.1) INCLUDE THE LATERAL LOAD -RESISTING SYSTEM. ([BS] 907.4.2) ]� Signed and sealed structural analysis is attached for your reviews /rn f.61(illi (J01= REVIEW COMMENTS Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce; FL U982 Page 2 12/19/2019 Comment: 4) ALTERATIONS SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE, ENERGY CONSERVATION. NO INFORMATION PROVIDED FOR INSULATION. (908.1) Insulation of floor and exterior wall will be provided per the plans 12/19/2019 Comment: 5) PLEASE PROVIDE PRODUCT APPROVALS FOR ALL PROPOSED COMPONENTS $ CLADDING (WINDOW). (707.4) Product approval is included in the plans 12/19/2019 Comment: 6) PLEASE PROVIDE A COMPLETE DETAIL FOR THE ALTERED AREAS OF THE BUILDING ENVELOPE. ((A] Areas altered are shown in the plans 107.2.1) 12/20/2019 Comment: 7) IT IS UNCLEAR THE EXTENT OF MECHANICAL WORK PERFORMED IF ANY. ([A] 107.2.1) P, No mechanical work is planned. Once all other work is complete, we will hire A HVAC contractor P To install a Heat Pump Unit. They will acquire permit at that time. 1/17/2020 Comment: "COMMENTS BELOW ARE FROM PLANS EMAILED FROM THE OWNER ON 1/16/20, JACQUES REGISTE." Noted S��EtGJL GotfitG j "� Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue FortPierce, FL 34982 REVIEW COMMENTS 1/17/2020 Comment: "9) STRUCTURAL DRAWINGS RECEIVED. ALL WORK ON THE BUILDING WILL NEED TO BE DOCUMENTED ON THE PLANS." All work is shown in the plans 3 1117/2020 Comment: " 10) PLEASE SEE SECTION 301.1 OF THE FL BUILDING CODE EXISTING, NOTATE ON THE PLANS WHICH COMPLIANCE METHOD WILL BE USED." Compliance method level 3 alteration will be used Comment: "11) PLEASE SEE SECTION 501.1 OF THE FL BUILDING CODE EXISTING, NOTATE ON THE PLANS WHAT 1/17/2020 THE LEVEL OF ALTERATION IS. BASED ON THE PHOTO ATTACHED FROM THE CODE OFFICER, WE BELIEVE THIS IS A LEVEL 3 ALTERATION, WORK AREA EXCEEDS 50 PERCENT OF THE BUILDING AREA." Yes level 3 alteration has been used 1/17/2020 Comment: "12) THE BEAM AND JOIST LAYOUTS WILL NEED TO BE RE -LABELED AS'NEW . ALL MEMBER SIZES & CONNECTIONS WILL NEED TO BE SPECIFIED." All members have been relabeled new or existing 1/17/2020 Comment: "13) ALL BUILDING DEPARTMENT COMMENTS WILL NEED TO BE ADDRESSED." Noted PLANS EXAMINER REVIEW COMPLETE Jpi, Inc -Andrew 12/1912019 1/1712020 1117/2020 Comment: �j rrcro Goratx� Planning A Development Services Building 9 Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 REVIEW COMMENTS 1 PROPERTYINFORMATION Address: 4006 Avenue P City / State / Zip: Fort Pierce, FI 34947 Parcel #: 2405-601-0306-000/9 Jurisdiction: Zoning: RS-4 Lot#: APPLICATION INFORMATION Permit 1912-0391 Stories: Number: BUILDING (MISCELLANEOUS) Permit Type: CONTRACTOR INFORMATION Contractor Name: Business Name: Business Addr: City / State / Zip: Owner(s): Jacques Registe SAINT LUCIE COUNTY 16 Block: 16 Automatic Sprinkler System? No Fax Number: Email: REVIEWS AND COMMENTS Review Type Status Reviewed By Date Started Date Completed Date Released FRONT COUNTER REVIEW COMPLETE Karen Nielsen 1211912019 12119/2019 12/19/2019 Comment: PLANS EXAMINER REVIEW INCOMPLETE Jpi, Inc -Andrew 12119/2019 Comment: 1) PLEASE SEE THE FLORIDA BUILDING CODE, EXISTING AND CLASSIFY THE LEVEL OF WORK. (CH5) 12120/2019 PROVIDE THE COMPLIANCE METHOD. (CH3) Compliance method is level 3 Comment: 2) PLEASE PROVIDE A COMPLETE SET OF PLANS FOR REVIEW: 12120/2019 A) STRUCTURAL FLOOR FRAMING PLAN, ALL MEMBER SIZES & CONNECTIONS. B) DETAIL FOR HOUSE TO DECK CONNECTION. A set of Plans is attached 12/20/2019 Comment: 3) PLEASE PROVIDE AN ENGINEERING EVALUATION AND ANALYSIS THAT ESTABLISHES THE STRUCTURAL ADEQUACY OF THE ALTERED STRUCTURE- SHALL BE PREPARED BY A REGISTERED DESIGN PROFESSIONAL AND SUBMITTED TO THE CODE OFFICIAL. ([BS] 907.4.1) INCLUDE THE LATERAL LOAD -RESISTING SYSTEM. ([BS] 907.4.2) 12/20/2019 Comment: 4) A DESIGN PROFESSIONAL IS REQUIRED FOR THIS PERMIT. ([A] 107.1) A__.' Signed and sealed plans attached ZONING REVIEW PENDING Comment: