HomeMy WebLinkAboutConstruction PlansGENERAL 1. CONSTRUCTION IS TO COMPLY WITH THE REQUIREMENTS OF THE GOVERNING BUILDING CODE AND ALL OTHER APPLICABLE FEDERAL, STATE, LOCAL CODES, STANDARDS, REGULATIONS AND LAW. THE GOVERNING CODE FOR THIS PROJECT IS THE FLORIDA BUILDING CODE 2017 INCLUDING ALL CURRENT AMENDMENTS. 2. THE STRUCTURE IS DESIGNED TO BE STRUCTURALLY SOUND WHEN COMPLETED. PRIOR TO COMPLETION, THE CONTRACTOR IS RESPONSIBLE FOR STABILITY AND TEMPORARY BRACING OR SUPPORT. 3. DESIGN SUPERIMPOSED LOADS BUILDING LIVE LOAD--------- 40 PSF ROOF LIVE LOAD --------- 20 PSF DECK LOAD ---------- ---- 100 PSF 4. DESIGN WIND LOADS GOVERNING CODE -------------------- ASCE 7-10 ULTIMATE DESIGN WIND SPEED ------------- 158 MPH NORMAL WIND SPEED ------------------- V=123 MPH RISK CATEGORY ------------- III IMPORTANCE FACTOR ------------------ 1=1.0 EXPOSURE—MWFRS------- B CLADDING AND COMPONENT--B INTERNAL PRESSURE COEFFICIENT— —GCP+/-0.55 (ENCLOSED) MEAN ROOF HIGH --------- 19.5 FEET WIND DIRECTIONAL FACTOR --- Kd= 0.85 TOPOGRAPHY FACTOR ------- 1.0 5. VERIFY ALL DIMENSIONS AND SITE CONDITIONS PRIOR TO START OF CONSTRUCTION. NOTIFY THE ARCHITECT/ENGINEER OF ANY DISCREPANCIES OR INCONSISTENCIES. NO CHANGES OF INFORMATION SHOWN ON THE DRAWINGS SHALL BE MADE WITHOUT THE SPECIFIC WRITTEN APPROVAL OF THE ARCHITECT/ENGINEER. DESIGN INFORMATION SHOWN ON THE DRAWINGS PROVIDE OVERALL DIMENSIONAL PARAMETERS AND DESCRIBE ELEMENTS TO BE CONSTRUCTED. THE CONTRACTOR SHALL ADJUST DIMENSIONS AND DETAILS AS REQUIRED TO FIT EXISTING CONDITIONS. THE ARCHITECT/ENGINEER SHALL BE NOTIFIED OF ANY PROPOSED MODIFICATIONS. 6. DETAILS LABELED "TYP." APPLY TO ALL SITUATIONS THAT ARE THE SAME OR SIMILAR TO THOSE SPECIFICALLY REFERENCED, WEATHER OR NOT THEY ARE KEYED IN AT EACH LOCATION. QUESTION REGARDING THE APPLICABILITY OF TYPICAL DETAILS SHALL BE RESOLVED BY THE ENGINEER. 1) ALL WINDOWS.SHALL MEET THE WIND PRESSURE SHOWN ON THIS SHEET SCOPE OF WORK: 1) REPLACE 1 - WINDOW 2) REPAIR BATHROOMS 3) INSTALL KITCHEN SINK 4) REPAIR SIDING 5) REPAIR STAIRWAY AND AND COUNTER TOP DECK ALL REPAIRS SHALL BE DONE PER THE DETAILS SHOWN IN THIS SET OF PLANS. COMPLIANCE METHOD LEVEL 3 R JACQUES REG15WE, P.E. 1 P.E. LICENSE NUMBER 43397 EBBSTONE, INC. 3370 CAPITAL CIRCLE NE, SUITE 1 TALLAHASSEE, FL 32308 CERTIFICATE OF AUTHORIZATION 9292 CONNECTORS ALL CONNECTORS AND FASTENERS SHALL BE GALVANIZED UNLESS OTHERWISE NOTED. 2. CONTRACTOR SHALL USE ALL FASTENERS REQUIRED TO OBTAIN MAXIMUM PUBLISHED CONNECTOR LOADS UNLESS OTHERWISE NOTED. 3. CONTRACTOR SHALL INSTALL ALL CONNECTORS IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. DIMENSIONAL LUMBER (NEW) .1. ALL LUMBER SHALL CONFORM TO AMERICAN SOFTWOOD LUMBER STANDARD PS-20. 2. MATERIAL SHALL BE SOUTHERN PINE, COMPLYING WITH THE FOLLOWING MIN. ALLOWABLE STRESS LIGHT FRAMING --------------- Fb (BENDING) 1500 PSI (2X2 THROUGH 4X4) E. 1,600.000 PSI BEAMS AND STRINGERS ---------- Fb (BENDING) 975 PSI POSTS AND TIMBERS ----------- Fb (BENDING) 850 PSI (5X5 AND LARGER) ULTIMATE DESIGN WIND PRESSURES (PSF) ZONE EFFECTNE WIND AREA 10 SF 100 SF 1 (ROOF 1) 40.0/-55.2 32.3/-51.4 2 (ROOF 2) 40.0/-85.6 32.3/-66.6 3 (ROOF 3) 40.0/-119.9 323/-97.0 4 (WALL 4) 59.0/42-8 52.3/-56.1 5 (WALL 5) 59,0/-74.2 52.3/-60R EDGE ZONE I.) . 3.0' ASCE 7-10 COMPONENT AND CLADDING DESIGN NOTE: ULTIMATE WIND PRESSURE FROM ASCE 7-10 WAS USED. COVERSION FACTOR OF 0.6 USING ASO CAN BE USED FOR WINDOWS SPECIFICATIONS. -w -WED FOR S1. LU;} IE COUNT-c ®CC RENOVATION PLANS I` C3V 4006 Avenue P, Fort Pierce Florida S -ETNO. s-1 III III III III III III III III III =; Ex. 2X8 JC III III III �IIIIII�� III III _________ III III III III III III III III III III III e III New 2X8 JC II�------------------ III III III III III III III SIMPSON ' III III III H2.5A@. III III III INTERSEC 6"X6' Columns III III III 6"X6" Columr (TYP)--------_ ---__--_— (TYI III III III III III III _ III III III e III III III III III III u, — — — — — — — — — — o III III III — o III III III III III III I M III 2-2X IO III III z - zxla (TYP) n III III III I o III III III III III III - III III 10"XIO" Columns III III III (TYP) III 4'-0" 1 11'-611 EXISTING BEAM LAYOUT REVISIONS 4-NEW 2X8 0 12' o.c. JACQUES REGISTE, P.E. P.E. LICENSE NUMBER 43397 EBBSTONE, INC. 3370 CAPITAL CIRCLE NE, SUITE 1 TALLAHASSEE, FL 31308 CERTIFICATE OF AUTHORIZATION 9292 i ■I�I�I■II■I�II�I�'' IL�I' �, !, I III► F I EXISTING FLOOR JOIST LAYOUT RENOVATION PLANS 4006 Avenue P, Fort Pierce Florida INSTALL FULL DEPTH BLOCKING (TYP) FED FOR MPLIANI COUNI I= -Ex. 2X8 JOIST @ 16.O.C. (TYP) 'ICI, 16 iD F.OWC.NO. sx�rno. S 2 Jluc V1CVV N.T.S. FRONT VIEW PTTRIM VK 'ED SIDING REVIEWED FOR CODE COMPLIANCE STo LUCIE COUNTY BOCC EXISTING BUILDING ELEVATION rz EVNs�o Ns JACQUES REGISTE, P.E. wr er' K.G. 01-2 asr.owc.rvo, onrt By oescwvriox onre ar oeswanox P.E. LICENSE NUMBER 43397 GIE RENOVATION PLANS EBBSTONE, INC. J.R. 01-2 01-20 3370 CAPITAL CIRCLE NE, SUITE 1 oeOBxmm vaoic<rxue TALLAHASSEE, FL 32308 J.R. 01-20 sxefrxo. CI MmBY: 4006 Avenue P, Fort Pierce Florida CERTIFICATE OF AUTHORIZATION 9292 J.R. ni-2n S-3 6"X6" Colun IT EXISTING FOUNDATION LAYOUT STAIRS TO BE REPAIRED a 0 0 y WINDOW TO IIII U BE REPLACED I n�1 IL L_JI I I I i j ILLILL I I I I 1p C-�- C�I I BATH TO BE I II I II I II I II I I I EXIST. ENTRY DOOR Sg KITCHEN TO BE REPAIRED 1:/►[9:17fZL'/;f1C TO BE REPAIRED 2 SLIDIND GLASS DOORS (EXIST.) a i� I _� II I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I �lrl• I�.IUf�ll� COI — — I i6 �IIK Ik EI ��Rrklb I IIII IIII �8'�X8'� Columns gb' C lyl )I I I I I I I I I I I I I I I 4'-0" NOTE: HATCHED AREA TO BE REPAIRED S0A 11'-6" 11'-81, ONCE NITY 'I mwplw-� EXISTING HOUSE PLAN U 5 REVISIONS JACQUES REGISTE, P.E.- � pA1E BY DESCWP¶ON DATE BY OESCRIPIION rK.G. 0]-2 REF.OWO.NO. P.E. LICENSE NUMBER 43397 KCKEpsr. RENOVATION PLANS EBBSTONE, INC. 01-203370 CAPITAL CIRCLE NE, SUITE J MEDBY.TALLAHASSEE, FL 32308 . 01-20sxEErNO.CERTIFICATE OF AUTHORIZATION 9292 'n7-7n 4006 Avenue P, Fort Pierce Florida 5 4 4 INSTALL 0 (H.D.G.) THRU BOLTS WITH NUTS AND WASHERS TO AT ALL JOIST & POST CONNECTIONS 3BEAMSSECUREDI TH 3-112"X8" HOG CH. BOLTS WI NUT D WASHERS TYP. EXISTING POST EXISTING STAIR DETAIL N.T.S. (TO BE REPAIRED) 2"X2" PICKETS 5-1/2"O.0 WITH A 30' CUT AT THE EXISTING POST 2X6 P. T. N RAIL WITH WITH (2)-3/8' 0 <H.➢.G) THRU AND BOLTS WITH NUTS AND WASHERS F.It TOP & BOTTOM ❑F POST (TYP.) 4" P.T. STANTION (2)-1/2"0 (H.D.G.) THRU BOLTS WITH NUTS AND WASHERS AT ALL J0IST PROPOSED STANTION DETAIL N.T.S. TOP AND THE BOTTOM 2"X2" PICKETS 5-1/2"O.C. WITH A 30' CUT AT THE 2"X6" TOP PLATE, WITH TOP AND THE BOTTOM A 1/4" OVER HANG THE OUTSIDE EDGE OF THE (2)-3/8" 0 THRU BOLTS PILING, (SECURED WITH WITH NUTS AND WASHERS AT THE (2)-(H.D.G,) SCREWS PER TOP AND BOTTOM OF THE POST PILING) CONNECTIONS. 2"X4" RAIL WITH BEVELED EDGES NJ 2"'8(H.D.G.) SCREWS TYP. 4"X4" P.T. STANTION 2"X4" RAIL WITH 1-1/2" GAP ABOVE DECKING 2"X6" P.T. JOIST (21-1/2"0 THRU I6'-0" TYP 6'-0"2XIO BCCIILTS WITH NUTS AND WASHERS AT ALL JOIST & 8"X8" POSTS) I I SEE DETAIL'A' PILING CONNECTIONS (BEAM TO COLUMN CONNECTION) 8"X8" POSTS I EXISTING GROUND ........... _ I, _U_ LI LI VIEW A -A PROPOSED DECK ELEVATION WITH RAILINGS N.T.S. 2%6" DECKING 2x8 P.T. - CROSS BEAM M (5) 2x6 P.T. JOIST (TYP.) SECTION 8-8 2 - 2XIO BEAMS I 8X8 COLUMN (2)-1/1" 0 (H.D.G.) THRU BOLTS WITH NUTS AND WASHERS TO AT ALL JOIST & POST CONNECTIONS SIMPSON STRONG TIE H2.5A @ JOIST/BEAM INTERSECTION (TYP.) (2)-3/a" 0 (H.D.G.) THRU BOLTS WITH NUTS AND WASHERS AT ALL BEAM TO POST CONNECTIONS (TYP.) —6"X6" POSTS WITH A MIN. DEPTH OF 6' BELOW NATURAL GRADES (AGO OF 2.5 LBS./IN.) (TYP.) 2X8 JOIST ADO 1 3/4' BOL T 2 - 2XIO BEAMS Exist. BOL IS DETAIL "A" N.T.S. (EXISTING BEAM TO C0.`L/4N CETNNECTION) ma EXISTING GROUND REVIEWED FOh CODE COMPLIA! OL ST. LUCIE COUN i Y BOCC Rev�s�orvs JACQUES REGISTE, P.E. Br scw r r BBB. Dwc,ND. WE BY DEDnTB UUMMox K.G. 01-2 P.E. LICENSE NUMBER 43397 .G.CHEM�$Y. RENOVATION PLANS EBBSTONE, INC. J.R. 01-20 3370 CAPITAL CIRCLE NE, SUITE 1 MMEDBY. wME TALLAHASSEE, FL 32308 J.R. 01-20 SBBBTND. CERTIFICATE OF AUTHORIZATION 9292 DBBG`mBµ 4006 Avenue P, Fort Pierce Florida S-5 J.R. 01-20 PANEL EDGE Nj IOD @ 4" O.C. '� FLOOR SHEATHING DETAILS (T[]P BBOT TOMl SCALE :N.i.i Simpson Strong -Tie H5 NOTES ALL HORIZONTAL AND INCLINED MEMBERS THAT RECEIVE DECKING SHALL BE FRAMED AS A WOOD STRUCTURAL PANEL DIAPHRAGMS. FASTENERS SHALL BE GALVANIZED 10D RECTION OF RINGSHANK NAILS SPACED 4" O.C. AT PANEL FACE GRAIN EDGES AND ENDS, AND 6" O.C. IN THE FIELD OF THE PANEL. JOISTS BLOCKING SHALL BE PROVIDED AT ALL PANEL EDGES, BE THE SAME SIZE AS THE JOIST, AND INSTALLED IN FULL DEPTH ORIENTATION (DO NOT LAY FLAT). DIRTIED PANEL SPACE PLYWOOD BUTT JOINTS 8' USING 16D EDGE NAILING BRIGHT COMMON NAIL AS TEMPORARY SPACER. FIELD NAILING AT INTERMEDIATE SUPPORTS Simpson Strong -Tie H5 LSTA18 Simpson Strong -Tie SHINGLE ROOF ROOF RAFTERS 22'-0' O.C. METAL DRIP GALV. TIEDOWN STRAP H5 AT EACH RAFTER WITHIN 2X8 OR 2X6 BEAMS JOIST INTERSECTIONS REINFORCEMENT AT ROOF/WALL AND FLOOR CONNECTION 12 4F__ INSTALL TIE DOWN - SIMPSON STRAP H2.5 TYP THROUGH OUT HURRICANE CLIPS EXISTING INSULATION EXISTING INSULATION SIMPSON LSTA18 (HOT -DIPPED GALV.) TIE DOWN STRAP AT EACH STUD (OUTSIDE FACE) TO RESIST UPLIFT. R-19 TO BE INSTALLED 2' X 8' 16' O.C. 2' X 8' BLOCKING PROPOSED 3/8' COX PLYWOOD 2- 2 X 10 BEAM'S SECURED TO PILING WITH (2) 5/8'0 X 14' Ga. MACH. NUT AND BOLTS WITH WASHERS TYP. ^�I EXIST. 10'0 PILING REVIEWED FOR CODE COMPLIANCE ST_ I imm COUNTY I^ 15' DEPTH (TYP) "I 1- • cxE=vESEONs JACQUES REGISTE, P.E. ogre er oEuwvnox are ar UESCWMN P.E. LICENSE NUMBER 43397 K.G. 0]-2 RENOVATION PLANS CHEMM Br: EBBSTONE, INC. J.R. 01-20 3370 CAPITAL CIRCLE NE, SUITE 1 MSMEoer. EorNNRE. TALLAHASSEE, FL 32308 J.R. 01-20 HEETxo. CERTIFICATE OF AUTHORIZATION 9292 ,pEaaoar: 4006 Avenue P, Fort Pierce Florida SS-6