Loading...
HomeMy WebLinkAboutReview CommentsEbbstone March 17, 2020 Andrew. Manero St. Lucie County Planning & Developmental Services I RE: 4006 Avenue P Fort Pierce, Florida House Repair Plans CIVIL, STRUCTURAL & WATER RESOURCE ENGINEERING Dear Mr. Manero, For your review, Ebbstone, Inc. has provided the following documentation for the repair of the referenced property. r • Signed and Sealed Repair Plans �4 Sete • Signed and Sealed Structural Assessment L2 t)e ) • Comment Responses Z e Sl Note, that the electrical and plumbing work its manor in nature and HVAC will bel done later.` Alcontractor will be hired to add a heat pump system, he will then pull the p rmit. Please review the attached documentation and give me call if you have any quE at (850) 544-1402. 1 am willing to work with you to get this repair done the best possible. Sincerely, P.E. Chief Engineer i r �i I 4QiG it Services L. 34982 ,ess: 4006 Avenue P ! State / Zip: Fort Pierce, FI 34947 el #: f 2405-601-0306-000/9 i n9; RS-4 Number: ; 1912-0389 REVIEW COMMENTS Owner(s): Jacques Registe Jurisdiction: SAINT LUCIE COUNTY Type: I I BUILDING RESIDENTIAL RENOVATION Name: ness Name: ness Addr. ! State / Zip: teview Type 'RONT COUNTER REVIEW Comment: E REVIEW COMMENTS (2) !Comment: 12/19/2019 i 12/19/2019 <Comment: 12119/2019 ! existing Lot#: 18 Stories: Block: 16 Automatic Fax Number. Email: Status Reviewed By Date Started Date Completed COMPLETE Deanna Givens 12/19/2019 12/1912019 INCOMPLETE Jpi, Inc -Andrew 1/17/2020 1) PLEASE SEE THE FLORIDA BUILDING CODE, EXISTING AND CLASSIFY THE LEVEL OF (CH5) PROVIDE THE COMPLIANCE METHOD. (CH3) PHOTOS INDICATE 100% OF THE FLOOR SYSTEM WAS CHANGED. Based on the photo provided the Compliance method is level 3 2) PLEASE PROVIDE A COMPLETE SET OF PLANS FOR REVIEW: ([A] 107.2.1) A) STRUCTURAL FLOOR FRAMING PLAN, ALL MEMBER SIZES & CONNECTIONS B) FLOOR PLAN WITH ROOMS LABELED & EGRESS SHOWN. C) LOCATE PLUMBING FIXTURES, APPLIANCES, ELEC. METER. D) ELECTRICAL PLAN, COMPLIANT WITH SECTION (808.3) INCLUDE LOCATION OF SMC ALARMS. (703.2) Signed and sealed Structural Plans is included for your review. No electrical f Electrical system was not altered. E) PLANS & SPECIFICATIONS SHOWING THE EXTENT OF PLUMBING WORK Plumbing work in the bathroom and kitchen is minimal and areas are shov 3) PLEASE PROVIDE AN ENGINEERING EVALUATION AND ANALYSIS THAT ESTABLISHE STRUCTURAL ADEQUACY OF THE ALTERED STRUCTURE- SHALL BE PREPARED BY A REGISTERED DESIGN PROFESSIONAL AND SUBMITTED TO THE CODE OFFICIAL. ([BSI 9 INCLUDE THE LATERAL LOAD -RESISTING SYSTEM. ([BS] 907.4.2) Signed and sealed structural analysis is attached for your reviews System? No 12/19/2019 as the I in the plans THE '.4.1) �HGtG (/06ifur�"E i Planning A Development Services Building 8, Cods Regulation Division 2300 Virgtnla Avenue Fort Pierce, FL 34982 REVIEW COMMENTS 12/19/2019 Comment: 4) ALTERATIONS SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE, ENERGY CONSERVATION. NO INFORMATION PROVIDED FOR INSULATION. (908. Insulation of floor and exterior wall will be provided per the i 121i9/2019 Comment: 5) PLEASE PROVIDE PRODUCT APPROVALS FOR ALL PROPOSED COMPONENTS & CLADDING (WINDOW). (707.4) Product approval is included in the plans 12/19/2019 Comment: BUILDING ENVELOPE. ([A] 12/20/2019 Comment: ([A] 107.2.1) ME hire A HVAC contractor 1/17/2020 Comment: 1/16/20, JACQUES REGISTE." 6) PLEASE PROVIDE A COMPLETE DETAIL FOR THE ALTERED AREAS IOF THE Areas altered are shown in the plans 107.2.1) 7) IT IS UNCLEAR THE EXTENT OF MECHANICAL WORK PERFORMED IF No mechanical work is planned. Once all other work is completb, we To install a Heat Pump Unit. They will acquire permit at that "COMMENTS BELOW ARE FROM PLANS EMAILED FROM THE OWNER C Noted I REVIEW COMMENTS Planning 8 Development Services Building & Code Regulation Division 270D Virglnla Avenue Fort Pierce, FL 34982 1/17/2020 - Comment: •-9) STRUCTURAL DRAWINGS RECEIVED. ALL WORK ON THE BUILDING WILL NEED T DOCUMENTED ON THE PLANS." All work is shown in the plans 1/17/2020 Comment: —10) PLEASE SEE SECTION 301.1 OF THE FL BUILDING CODE EXISTING, NOTATE ON WHICH COMPLIANCE METHOD WILL BE USED." Compliance method level 3 alteration will be used 'Comment: "11) PLEASE SEE SECTION 501.1 OF THE FL BUILDING CODE EXISTING, NOTATE ON' 1/17/2020 THE LEVEL OF ALTERATION IS. BASED ON THE PHOTO ATTACHED FROM THE CODE BELIEVE THIS IS A LEVEL 3 ALTERATION, WORK AREA EXCEEDS 50 PERCENT OF THE Yes level 3 alteration has been used 1/17/2020 Comment: —12) THE BEAM AND JOIST LAYOUTS WILL NEED TO BE RE -LABELED AS'NEW'. ALL MEMBER SIZES & CONNECTIONS WILL NEED TO BE " SPECIFIED." All members have been relabeled new or existing 1/17/2020 Comment: "13) ALL BUILDING DEPARTMENT COMMENTS WILL NEED TO BE ADDRESSED." Noted PLANS EXAMINER REVIEW COMPLETE Jpi, Inc -Andrew 12/1912019 1/17/2020 1/17/2020 Comment: '6 PLANS PLANS WHAT CER, WE �c^ .'