Loading...
HomeMy WebLinkAboutM Garcia Engineering SealedI . THESE PLANS PERTAIN ONLY TO THE STRUCTURE, INCLUDING MAIN WIND FORCE RESISTING SYSTEM, COMPONENTS AND CLADDING, AND BASE RAIL ANCHORAGE. OTHER DESIGN ISSUES, INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET—BACKS, FINISH FLOOR ELEVATION AND SLOPE, OR OTHER LOCAL ZONING REQUIREMENTS ARE THE RESPONSIBILITY OF OTHERS. 2. THIS STRUCTURE IS DESIGNED AS A NON—HABITABLE UTILITY/STORAGE BUILDING (RISK CATEGORY 1) CAPABLE OF SUPPORTING DEAD LOAD OF THE STRUCTURE AND APPLICABLE LIVE AND WIND LOADS. IMPROVEMENTS NOT SPECIFICALLY ADDRESSED HEREIN, INCLUDING DOORS, WINDOWS, OR OTHER COMPONENTS NOT LISTED IN THE FBC APPROVED PRODUCTS LIST, AND NOT PROVIDED AND INSTALLED BY CARPORTS ANYWHERE, INC., WHICH EXERT ADDITIONAL LOADS ON THE STRUCTURE SHALL BE AT THE OWNER'S RISK. CARPORTS ANYWHERE NOR THE ENGINEERING DESIGN SHALL NOT BE RESPONSIBLE FOR STRUCTURAL DAMAGE OR FAILURE DUE TO THE APPLICATION OF ADDITIONAL LOADS. 3. THIS BUILDING IS EXEMPT FROM THE FBC ENERGY CONSERVATION CODE PER SECTION C101.4.2. 4. ALL STEEL TUBING SHALL BE 50 KSI STEEL AND MEETS/EXCEEDS GALVANIZATION PER ASTM A1003/A1003M-15. 5. PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET—BACKS, AND/OR OTHER LOCAL CODE REQUIREMENTS ARE THE RESPONSIBILITY OF THE OWNER. 6. ROOF AND WALL SHEATHING SECURED WITH #12-14x1" SELF—DRILLING SCREWS WITH SEAL WASHERS ® 6" O.C. MAX. 7. FIELD FRAMING CONNECTIONS SECURED WITH #12-14x3/4" SELF—DRILLING SCREWS. 8. ALL SHOP FRAMING CONNECTIONS ARE TO BE WELDED. NO WELDING ONSITE. ALL WELDING DONE IN SHOP. 9. CONCRETE EXPANSIONS ANCHORS ARE TO BE MINIMUM 1/2" DIAMETER & 2,500LB TENSILE STRENGTH. 10. 12 OR 14GA- FRAMING IS 2.5"x2.5" TUBE STEEL. NIPPLES ARE 2-25"x2.25" TUBE STEEL. GROUND ANCHOR WITHIN 6" OF EACH POST. ANCHOR SECURED WITH 4" GRADE 5 BOLT MINIMUMBASE JAIL WITH 2" WASHERS "i' "ASPHALT OR MINIMUM SOIL DOUBLE 4" HELIX EARTH BEARING CAPACITY AUGER GROUND ANCHOR 2,000 PSF (TYP.) (SEE CHART FOR LENGTH) GROUND ANCHOR BASE RAIL DETAIL Ground Anchor Length (all buildingwidths:_30') Wind Speed (mph) Soil Type :5140 145-155 160-170 175-180 Very dense and/orcementedsand,coarsegrave 1, 3011 30" 48" 48" cobbies, preloaded silts, clays a nd coral OCCUPANCY UTILITY, U WIND SPEED Vult-150mph Medium dense coarse sands, sandygravels, 30" 48" 48" 60" very stiff silts and clays IMPORTANCE FACTOR 1.0 ROOF DEAD LOAD IOPSF Loose to medium dense sands, firm to stiff 48" 48" 60" 60" clays, silts, and alluvial fill "R"RATING OF WALLS, FLOOR, ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE Loose sands, firm clays, silts, and alluvial fill 48" 60" 60"* 60"* * - 2 anchors per post unless soil changes to a more desirea ble type at half depth ors ha (lower. 30'-0" O 0 I n 1 0 i 0 CODE VERSION FBC 2017 6th Edition, ASCE-7-10 MANUFACTURER CARPORTS ANYWHERE BUILDING TYPE UTILITY STRUCTURE CONSTRUCTION TYPE II—B RISK CATEGORY I FIRE PROTECTION NONE FIRE SUPPRESSION SYSTEM NONE OCCUPANCY UTILITY, U WIND SPEED Vult-150mph EXPOSURE B ENCLOSURE OPEN INTERNAL PRESSURE COEFF. +/— 0.0 IMPORTANCE FACTOR 1.0 ROOF DEAD LOAD IOPSF ROOF LIVE LOAD OPSF OR 3001b P.L. FLOOR DEAD LOAD 10PSF FLOOR LIVE LOAD 50PSF "R"RATING OF WALLS, FLOOR, ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE NO SQUARE FOOTAGE 900 SQ. FT. REVISIONS MTB 4/26/20 5213 Buchanan Dr., Ft. Pierce I"" 30'L X 30'W X 12'H 11 O aV!'cf, N�.xw s,. W 4%27%20` z Matthew" T. BOIdWin P.E. Florida License #64608 Q w J E Sheet: CA— OF 4 12 3 _- "° �. MPX j O I i'4 CAMRT'SiAWAFHERE CODE INFORMATION CODE VERSION FBC 2017 6th Edition, ASCE-7-10 MANUFACTURER CARPORTS ANYWHERE BUILDING TYPE UTILITY STRUCTURE CONSTRUCTION TYPE II—B RISK CATEGORY I FIRE PROTECTION NONE FIRE SUPPRESSION SYSTEM NONE OCCUPANCY UTILITY, U WIND SPEED Vult-150mph EXPOSURE B ENCLOSURE OPEN INTERNAL PRESSURE COEFF. +/— 0.0 IMPORTANCE FACTOR 1.0 ROOF DEAD LOAD 1OPSF ROOF LIVE LOAD 20PSF OR 3001b P.L. FLOOR DEAD LOAD 1OPSF FLOOR LIVE LOAD 50PSF "R°RATING OF WALLS, FLOOR, ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE NO SQUARE FOOTAGE 900 SQ. FT. REVISIONS REV DESCRIPTON DATE BY 30'-0" FRONT/REAR END WALL W DRAWN BY: MTB DATE: 4/26/20 LOCATION: 5213 Buchanan Dr., Ft. Pierce SIZE: 30'L X 30'W X 12'H r i \ \ N' v .. 4's" O.C. MAX. ' 3,-8 ' 6 6 6 6 IIIF 3'-8 3'-8 3'-8P6' 30'-0"- 3,— „ 3,_8 „ 3,_8 3,_$ „ 6 6 6 �� LEFT/RIGHT SIDE WALL W o .a:t th Y Matthew T. Baldwin P.E. Florida License #64608 rSZt-_CA-2 OF 4 N CARP MANYMERE CODE INFORMATION CODE VERSION FBC 2017 6th Edition, ASCE-7-10 MANUFACTURER CARPORTS ANYWHERE BUILDING TYPE UTILITY STRUCTURE CONSTRUCTION TYPE II—B RISK CATEGORY I FIRE PROTECTION NONE FIRE SUPPRESSION SYSTEM NONE OCCUPANCY UTILITY, U WIND SPEED Vult-150mph EXPOSURE B ENCLOSURE OPEN INTERNAL PRESSURE COEFF. +/— 0.0 IMPORTANCE FACTOR 1.0 ROOF DEAD LOAD 1OPSF ROOF LIVE LOAD 20PSF OR 3001b P.L. FLOOR DEAD LOAD 1OPSF FLOOR LIVE LOAD 50PSF "R"RATING OF WALLS, FLOOR, ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE NO SQUARE FOOTAGE 900 SQ. FT. REVISIONS REV DESCRIPTON DATE BY 30'-0" FRONT/REAR END WALL N 0 I LL Z W DRAWN BY: MTB DATE: 4/26/20 LOCATION: 5213 Buchanan Dr., Ft. Pierce SIZE: 30'L X 30'W X 12'H — � _ t 30'-0" LEFT/RIGHT SIDE WALL � LL_I Matthew T. Baldwin P.E. Florida License #64608 Sheet: CA-3 OF 4 MINIMUM 6" TS NIPPLE. NIPPLE SECURED TO WALL POST WITH (4)#12-14xi" SELF—DRILLING SCREWS _ 11 NIPPLE TO T BASE RAIL POST TO BASE RAIL CONNECTION NIPPLE BASE RAIL/ v\` 26 GAUGE ROOF SHEATHING SECURED WITH (1)# MINIMUM 6" TS NIPPLE. NIPPLE SECURED TO WALL POST WITH (4)#12-14xi" SELF—DRILLING SCREWS +20.0/-22.2 2"x2"x2" 16 GA. ANGLE CLIP SECURED WITH (4) #12-14xq" FL27403.1 SELF—DRILLING SCREWS +20.0/-22.2 END POST TO BASE RAIL CONNECTION SCREWS TO EACH RAFTER. ROOF PANEL CONNECTIO VERTICAL SHEATHING OPTION DESIGN PRESSURES - 150 Mph ROOF +19.3/-41.4 FL27402.1 —R1 WALLS +20.0/-22.2 DOORS +20.0/-22.2 FL27403.1 WINDOWS +20.0/-22.2 1 2 3 4 5 ZONE +9.3 -21.9 +12.3 -35.1 +19.3 -41.4 +18.8 -21.9 +20.0 -22.2 NIPPLE TO TRUSS F16 GA. U—CHANNEL BRACE, MIN. 24" UP TO 7' POST, MIN. 48" OVEF 7' POST. MIN. 45° TO MAX. 60° FROM HORIZ. (EXCLUDE END—WALLS) MINIMUM 6" TS NIPPLE. NIPPLE SECURED TO WALL POST WITH (4)#12-14xi" SELF—DRILLING SCREWS BOX SAVE RAFTER TO POST CONNECTION DETAIL NIPPLE TRUSSED RAFTER CONNECTION DETAIL APPROVED PRODUCTS APPROVAL NO. ROOF SHEATHING Carports Anywhere FL27402.1 —R1 Hampton Rib Roof Panel WALL SHEATHING Carports Anywhere FL27403.1 Hampton Rib Wall Panel CODE VERSION FBC 2017 6th Edition ASCE-7-10 MANUFACTURER CARPORTS ANYWHERE BUILDING TYPE UTILITY STRUCTURE CONSTRUCTION TYPE II—B RISK CATEGORY I FIRE PROTECTION NONE FIRE SUPPRESSION SYSTEM NONE OCCUPANCY UTILITY, U WIND SPEED Vult-150mph EXPOSURE B ENCLOSURE OPEN INTERNAL PRESSURE COEFF. +/— 0.0 IMPORTANCE FACTOR 1.0 ROOF DEAD LOAD 1OPSF ROOF LIVE LOAD OPSF OR 3001b P.L. FLOOR DEAD LOAD 1OPSF FLOOR LIVE LOAD 50PSF "R"RATING OF WALLS, FLOOR, ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE NO SQUARE FOOTAGE 900 SQ. FT. REVISIONS REV DESCRIPTON DATE BY unnnry GT: MTB DATE: 4/26/20 LOCATION: 5213 Buchanan Dr., Ft. Pierce SIZE: 30'L X 30'W X 12'H J Matthew T. Baldwin P. E. Q Florida License #64608 I:i W Sheet: CA -4 OF I 4