Loading...
HomeMy WebLinkAboutPD_FBC FL27403-R1 WallProduct Manufacturer Carports Anywhere Address/Phone/Email 10858 S.E. County Road 221 Starke, FL (352)468-1116 bodom@carportsanywhere.com Authorized Signature Brandie Odom bodom@carportsanywhere.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Structural Components Subcategory Structural Wall Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Terrence E. Wolfe the Evaluation Report Florida License PE -44923 Quality Assurance Entity PRI Construction Materials Technologies, LLC. Quality Assurance Contract Expiration Date 06/13/2023 Validated By Brian Jaks, P.E. Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code FL27403 R1 COI Letter of Certification.odf 1709.2 Product Approval Method Method 2 Option B -.tet . + y.- •r sl�l BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search dbr a�".I Product Approval P USER: Public User Product Approval Menu > Product or Apolication Search > Application Lis[ > Application Detail FL # FL27403-R1 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Carports Anywhere Address/Phone/Email 10858 S.E. County Road 221 Starke, FL (352)468-1116 bodom@carportsanywhere.com Authorized Signature Brandie Odom bodom@carportsanywhere.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Structural Components Subcategory Structural Wall Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Terrence E. Wolfe the Evaluation Report Florida License PE -44923 Quality Assurance Entity PRI Construction Materials Technologies, LLC. Quality Assurance Contract Expiration Date 06/13/2023 Validated By Brian Jaks, P.E. Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code FL27403 R1 COI Letter of Certification.odf 1709.2 Product Approval Method Method 2 Option B Date Submitted 08/08/2019 Date Validated 08/09/2019 Date Pending FBC Approval 08/26/2019 Date Approved 10/15/2019 Summary of Products FL # Model, Number or Name Description 27403.1 Hampton Rib Wall Panel Hampton Rib Wall Panel over open Framing Limits of Use Installation Instructions Approved for use in HVHZ: No FL27403 R1 II Hampton Rib Wall Panel over open Approved for use outside HVHZ: Yes framing.Ddf Impact Resistant: N/A Verified By: Terrence E. Wolfe, P.E. 44923 Design Pressure: +46.9 psf/-57.3 psf Created by Independent Third Party: Yes Other: See Evaluation Report for various Design Pressures. Evaluation Reports Install per Manufacturer's Details. Not for use in HVHZ FL27403 R1 AE Hampton Rib Wall Panel over open Zones, framino.pdf Created by Independent Third Party: Yes 27403.2 Resi-Lap Siding Wall Panel Resi-Lap Siding Wall Panel over open Framing Limits of Use Installation Instructions Approved for use in HVHZ: No FL27403 R1 11 Resi-Lao Wall Panel.pdf Approved for use outside HVHZ: Yes Verified By: Terrence E. Wolfe, P.E. 44923 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +40.0 psf/-37.0 psf Evaluation Reports Other: +40.0 psf at 4'-0" o.c. -37.0 psf at 4'-0" o.c. Install FI -27403 R1 AE Resi-Lap Wall Panel.odf per Manufacturer's Details. Not for use in HVHZ Zones. Created by Independent Third Party: Yes Contact Us :: 2601 Blair Stone Road Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: U ® Ed M Credit Card Safe Force Engineering & Testing Inc. 19530 Ramblewood Drive Humble,TX 77338 Product Evaluation Report CARPORTS ANYWHERE Hampton Rib Wall Panel over open framing Florida Product Approval # 27403.1111 Florida Building Code 2017 Per Rule 61G20-3 Method: 2—B Category: Structural Components Subcategory: Structural Wall Compliance Method: 61G20 -3.005(2)(b) NON HVHZ Product Manufacturer: Carport Anywhere 10858 S.E. County Road 221 Starke, Florida 32091 Engineer Evaluator: Terrence E. Wolfe, P.E. # 44923 Florida Evaluation ANE ID: 1920 Validator: Brian Jaks, P.E. #70159 Contents: Evaluation Report Pages 1- 4 E CFNSF`�'� 449 �✓ 3��' STATE OF ; a 0 P11 ,,,, rrOr�i�ititis ♦V,�. FL# 27403.1 R1 August 8, 2019 Force Engineering & Testing Inc. 19530 Ramblewood Drive Humble,TX 77338 Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2017, Sections 1709.2. Product Description: Hampton Rib 26 Ga. and 29 Ga. Steel Wall Panel, 36" Wide, through fastened structural wall panel. Structural Application. Panel Material/Standards: Material: 26 Ga. Steel, ASTM A792 or ASTM A653 G90 Grade 50 29 Ga. Steel, ASTM A792 or ASTM A653 G90 Grade 80 Conforming to Florida Building Code 2017 Section 1405.2. Panel Dimension(s): Thickness: 26 Ga.: 0.0185" min. order thickness 29 Ga.: 0.0142" min. order thickness Width: 36" maximum coverage Rib Height: %" major rib at 9" O.C. Panel Rollformer: MRS Metal Rollforming Systems Panel Fastener: #12-14 x %" HWH SD#3 with 14mm neoprene bonded washing or approved equal. Corrosion Resistance: Per Florida Building Code 2017. Substrate Description: Minimum 14 Ga. (Grade 50) Steel framing, Minimum 16 Ga. (Grade 50) Steel framing, or Minimum 18 Ga. (Grade 50) Steel framing. See Table A & B for steel gauge. Framing must be designed in accordance w/ Florida Building Code 2017. Allowable Design Pressures: Table "A" 26 Ga. Hampton Rib Wall Panel Maximum Design Pressure: -57.3 psf -72.9 psf -67.7 psf +46.9 psf +54.7 psf Panel Fastener Pattern: 2-1-2-1 2-1-2-1 2-1-2-1 2-1-2-1 2-1-2-1 Panel Span: 5'-0" O.C. 4'-0" O.C. 4'-0" O.C. 5'-0" O.C. 4'-0" O.C. Substrate: Min. 14 Ga. Steel Framing Min. 14 Ga. Steel Framing Min. 18 Ga. Steel Framing Min. 18 Ga. Steel Framing Min. 18 Ga. Steel Framing *Design Pressure includes a Safety Factor = 2.0. `N`CsE CE ASF <'t`��i 470 * _ d ' STATE OF ; FL# 27403.1 Rl August 8, 2019 7� Force Engineering & Testing Inc. 19530 Ramblewood Drive Humble,TX 77338 Table "B" 29 Ga. Hampton Rib Wall Panel Maximum Design Pressure: -57.3 psf -150.9 psf +39.0 psf +143.1 psf Fastener Pattern: 6"-3"-6"-3"-6"-3"-6" 6"-3"-6"-3"-6"-3"-6" 6"-3"-6"-3"-6"-3"-6" 6"-3"-6"-3"-6"-3"-6" Fastener Spacing: 4'-0" O.C. 2'-0" O.C. 4'-0" O.C. 2'-0" O.C. Substrate: Min, 16 Ga. Steel Framing Min. 16 Ga. Steel Framing Min. 16 Ga. Steel Framing Min. 16 Ga. Steel Framing *Design Pressure includes a Safety Factor = 2.0. Code Compliance: The product described herein has demonstrated compliance with The Florida Building Code 2017, Section 1709.2. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2017, as relates to Rule 61G20-3. Performance Standards: The product described herein has demonstrated compliance with: ■ ASTM E 1592-05 (2012) Test method for structural performance of sheet metal roof and siding systems by uniform static air pressure difference Reference Data: 1. ASTM E 1592-05 (2012) Test Force Engineering & Testing, Inc. (FBC Organization # TST-5328) Report No. 667-006OT-18A-E, 667 -0061T -18A -D 2. Certificate of Independence By Terrence E. Wolfe, P.E. (No. 44923) @ Force Engineering & Testing, Inc. (FBC Organization # ANE ID: 1920) Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity. Installation: Install per manufacturer's recommended details. Insulation: Manufacturer's approved product (Optional) Panel Fire Classification: Fire classification is not part of this acceptance. ,,,��1►flttt�r�,, O ♦� �.t CE NSF<.o�i IVo. 444 • � �� A ' STATE OF ; a Sub crrkda. 1. ODA. • , •''��♦♦ CDA 41 .T . • V r2ern *Jr 1, r0 k 11111 1► N,`,♦ FL# 27403.1 R1 August 8, 2019 Force Engineering & Testing Inc. 19530 Ramblewood Drive Humble,TX 77338 Shear Diaphragm: Shear diaphragm values are outside the scope of this report. Design Procedure: Based on the dimensions of the structure, appropriate wind loads are determined using Chapter 16 of the Florida Building Code 2017 for wall cladding wind loads. These component wind loads for wall cladding are compared to the allowable pressure listed above. The design professional shall select the appropriate erection details to reference in his drawings for proper fastener attachment to his structure and analyze the panel fasteners for pullout and pullover. Support framing must be in compliance with Florida Building Code 2017 Chapter 22 for steel, and Chapter 16 for structural loading. %* C...E... 4,o C E NSF `'�` ^No. 47 '•'k' STATE OF ; a 0 RI 4' •''`':� sem. U ,,', FL# 27403.1 R1 August 8, 2019 26_ GA. HAMPTON RIB FASTENER, PATTERN 2-1-2-1 M12-14 x 3/4' H'7IH SD3 VJ/ 1.0/.H BONDED NEOPRENE WASHER 29 GA. HAMPTON RIB FASTENER PATTERN 6"-3"-6"-3 6"-3"-6" 3., 6. 3.. -- - 3F - ` it 12-14 x 3/4" HWH SD3 W/ 141,11.1 BONDED NEOPRENE VASHER ofnooft \\`Ntttlltt)Ir11/����/J `` � IN C E E, ii�4 $ van Nb. 44923 9 STA ; 0 X". W <OAlR10. August 8, 2019