Loading...
HomeMy WebLinkAboutmahlschnee child barrier affadavitPLANNING & DEVELOPMENT SERVICES DEPARTMENT NORM Building and Code Regulations Division 2300 VIRGINIA AVE FORT PIERCE, FL 34982 (772)462-1553 Fu (772)462-1578 AFFIDAVIT OF REQUIREMENT COMPLIANCE Residential Swimming Pools, Spa, and Hot Tub Safety Act PERMIT p I (We) aicklowledge that a new y"tllmling 1, spa, or hot tub will be constructed or installed at 6499z ` ��`+'K..S� and hereby affirm that one of the following methods (Please print etre t address) ,awill be used to meet the requirements of Chapter 515, Florida Statutes: (Please initial the method used for pool.) TThe pool will be misted from access to the home by an enclosure that meets the pool barrier requirements of Florida Statute 51529. The pool will be equipped with an approved safety pool cover that complies with ASTM F1246.91(Standard Performance Specifications for Safety Covers for Swimming Pools, Spas, and Hot Tubs). All doors and windows providing direct access from the home to the pool will be equipped with an exit alarm that has a minimum sound pressure rating of 85decibels at 10 feet. All doors providing direct access from the home to the pool will be equipped with self closing, self latching devices with release mechanisms placed no lower than 54 inches above the floor or deck. I understand that not having one of the above installed at the time of final inspection, or when the pool is completed for contract Purposes, will constitute a violation of Chapter 515, F.S., and will be considered as committing a misdemeanor of the second degree, punishable by Ones up to $500.00 and/or up to 60 days in jail as established in chapter 775, F.S. I understand that the St. Lucie County Building Inspections Department assumes no liability for the final inspection of one of the above protective devices, or the lack of maintenance, or the removal of such after the swimming pool has been finalized. f, thee contractor, agree to instruct the owner of the proper use and maintenance of such sa!fpty devic CO CiOR SIGNATURE ' �uej QO ER SIGNATtUST OF FLORIDA, COUNTY .NO Y PUBLIC The fore oing instrument was acknowledged before me this day of f I 1 .20 ZD , bym Personally Known or Produced Identification Type of IdentificationPro R • Josandra A. Ingraham NOTARY P L STATE OF FLORIDA o , o Catxrl# GG954178 Expires 3/9/2024 SLCPDS Revised 07/22/2014 TE OFFLORIDA, C L UN F C-�C. -/ C� '1 N04 OTARY P LIC The foregoing instrument was acknowledged before me this 4 day of m. 20 L0 by > Il� �i1)�5Cl�nU Personally Known or Produced Identification yL y� Type of Identification produced: 't JOsandra A. Ingraham NOTARY pUBLIC STATE OF FLORIDA mgi COtGG954778 ,Expires 3/9/2024 Life Saver Pool Fence Systems, Inc. Removable Pool Safety Mesh Barrier Fencing Technical Specifications Life Saver Pool Fence Systems, Inc. has manufactured removable pool safety fencing for over 13 years and has continuously evolved their methods and materials, often -time leading industry wide changes. A Manufacturer's Limited Lifetime Warranty guarantees every system for as long as they own it. Life Saver Pool Fence meets and exceeds all code requirements throughout Florida. Below you will find technical specifications on the components used in assembling the Life Saver Pool Fence. Textilene Mesh Textilene mesh has been used as the highest quality material to the pool fence industry for over 15 years. Laboratory testing shows its strengths to surpass all code specifications and applicable ASTM standards. Item Number: T70 DFS Product Description: Fabric using .025" dia. vinyl -coated 1000 den. polyester core yams in the warp and fill. Construction, end/inch Weight, oz/yd2 Tensile Strength (grab), Ibf Tensile Strength (strip), Ibf Tear Strength, (Trapezodial), Ibf Ball Burst, Ibf Bursting Strength, psi Elongation, % Abrasion Resistance (CS10/500 cydes/ with no added weight) Flammability Rating Weatherability, 1200 hours Mildew Resistance ASTM D3775-96 D3776-96 D5034-95 D5035-95 Di 117-97 D3787-89 D3786-89 D5035-95 D3884-92 13.0+ .5 221.4 194.9 65.4 24.3 Fill 11.0 + .5 W. 213.3 153.8 54.0 335 433 21.6 No exposure of core yarn CS -191-53 & CA 117E G53-96 No discoloration G21-96 No growth The above results are a representative of real data from single test samples. Presently no specification is incorporated. Warp refers to the horizontal threading while fill refers to the vertical threading. As shown, all testing confirms Textilene mesh meets and, on all strength tests, amply exceeds the set code requirements. Reinforced 1" Aluminum Pale Life Saver Pont Fence uses Reinforced W3T6 t" Atumamrn Totes spaced no more ttrarr 36" apart. Mesh is secured to the pole via an aluminum cove molding using roundhead screws spaced no greater than 6". The temper rating of T6 scores the highest tensile strength (30 ksi) within the 6063 alloy classification. On July 10, 2003, Life Saver Pool Fence Systems, Inc. contracted Nutting Engineers of Florida, Inc., an ASTM standards testing lab established in 1967, to test the pole strength as per the Florida Residential Code 4501.17 At the time of testing, a lateral force was applied W a single pale at a nwasarewnt of W, from the surface of the deck. In the test, the resistance to lateral pressure was found to exceed 70 lbs. of pressure before failure on any single pole in a free standing installation, thus exceeding the 52 lbs. of horizontal force prescribed by the Florida Building Code.