Loading...
HomeMy WebLinkAboutPLANJET PUMP FROM POWER SUPPLY POOL FINISH APPROVED GROUND CLAMP CONTINUOUS BOND WIRE COMMON TO POOL STEEL, RAILS & EQUIPMENT 1" LIGHT CONDUIT M I N I M U M WATER LEVEL POOL PATIO UNDERWATER LIGHT DETAIL (NO SCALE) UNDERWATER LIGHT 1 8 " OUTSIDE ANGLE OF REPOSE 6' AND FURTHER = 4" THICK WALLS W/#3 REBAR @ 12" O.C. EACH WAY 3' TO 6' = 6" THICK WALLS W/#3 REBAR @ 12" O.C. EACH WAY 0' TO 3' = 8" THICK WALLS W/#3 REBAR @ 12" O.C. EACH WAY 4 " w a l l s 6 " 5 f t . 3 ft. 6 ft. 9 ft. 8 " w a l l s EXCAVATION INTO THE ANGLE OF REPOSE IS ALLOWABLE PROVIDED: * SHORING IS INSTALLED AT EXCAVATION AND SHORING SHOULD BE SUFFICIENT TO SECURE SOILS FROM EROSION OR SETTLEMENT * NO UNDERMINING OCCURS OR ENGINEER APPROVED IF ANY DOES * COMPACTION TEST OF THE BACKFILLED MARTIAL ARE PROVIDED AT C.O. OF THE SWIMMING POOL A N G L E O F R E P O S E MAX. WIDTH MIN. DEPTH 19'4" SHAPE FILL FROM EXCAVATION TILE FILTER PUMP HP: LIGHTS TRNFORM: MAIN DRAIN: SKIMMER RETURNS: VALVED VAC LINE DISCHARGE LINE CHLORINATOR HANDRAIL DIVING BOARD HEATER VACUUM HEAD VACUUM HOSE LEAF SKIMMER TREE / STUMP REMOVAL EXISITING PAVERS PUMP POOL PATIO RAIL FENCE BY PRINCE DEV. ELECTRICAL POOL PATIO DECK DRAIN GALLON CAPACITY-POOL 14,945 GAL. GALLON CAPACITY-SPA 808 TURN-OVER RATE TERMITE TREAT BARRIER MAX. LENGTH 30' 4'MAX. DEPTH 6.5' CUST STOCKPILE ELEVATION T.B.D INTERIOR FINISH GEM CS200 PUMP MAKE PER FBC 4501.20 2.7HP VS FLOPRO POOL SPA POOL 3 CLR LED SPA 1 POOL 300 WATT SPA POOL 2 SPA 1 (1) POOL 3 SPA 2 JETS:POOL SPA 8 INCL FILL LINE INCL TO GROUND JANDY TRUE CLEAR SALT NA LADDER NA NA SLIDE NA JANDY 400K BTU PROPANE INCL INCL INCL POLE BRUSH TEST KIT INCL INCL INCL NA NA EDS ELECTRIC TRAVERTINE BY TAURUS BY TAURUS 6 hrs INC INC NA SKIMMER MIN. FLOW 25 GPM SURFACE AREA OF POOL –444 SQ. FT 93 LN FT SPECIFICATIONS 100 WATT MAX. WATER VELOCITY - 6 ft./s FROM TRUNK LINES TO 8 ft./s SUCTION LINES, 10fps MAX RETURN LINE JOB NAME: OAKMONT HOMES/ ROAF ADDRESS: 7683 PELICAN POINTE DR, JENSEN BEACH, FL PERMIT NO.: DATE DRAWN: APRIL 15TH , 2020 DRAWN BY: JASON BARAN CHECKED BY: AARON H. ALLEN CUSTOMER APPROVAL: SCALE: 1/4" = 1' POOLS, INC. CONCRETE STEP DETAIL 1. TREAD IS MIN. OF 10" WIDE. 2. RISER NOT GREATER THAN 12" EXCEPT IF MORE THAN (3) TREADS ARE USED. 3. ALL STEPS TO BE SOLID GUNITE 4000 PSI. MISC. NOTES 1. ALL STEPS AND SWIMOUT BENCH EDGES WILL HAVE 2X6 CAPTILE BORDER OF OPPOSITE COLOR OF GEM FINISH FOR VISIBILITY 2. HAND HOLD TO BE INSTALLED AT ARE WHERE DECK RAISED +6" ABOVE POOL N.T.S. 12" MAX. 10" MIN. STEPS #8 GROUND WIRE HANDRAIL BONDING DETAIL WHERE APPLICABLE PER NATIONAL ELECTRICAL CODE 48" MAX WATER DEPTH *LOCATION OF GFI RECEPTACLE TO BE DETERMINED IN FIELD PER NEC 680 2.7HP VS FLOPRO FILTRATION PUMP COMPLIANT WITH ANSI/APSP/ICC-15 2011 2HP PHPM · APPROVED WITH THE 2017 FLORIDA BUILDING CODE 6TH EDITION FOR RESIDENTIAL W.L. 18" MIN. ( ENTIRE PERIMETER) #8 SOLID COPPER BOND WIRE W/ APPR. CLAMPS (ONE ON EACH SIDE OF POOL 4 TOTAL ) 8 GAUGE SOLID COPPER WIRE SOIL MINIMUM 18" FROM EDGE OF POOL AROUND ENTIRE POOL PERIMETER BURIED 4" TO 6" DEEP , 24" MAX FROM POOL EDGE PAVER DECK OR CONCRETE DECK EQUIPOTENTIAL BONDING GRID DETAIL PER N.E.C. 2017 SEC. 680.26 (WHERE ADOPTED) TO MAIN SERVICE PANEL IN APPROVED CONDUIT (SIZED PER LOAD) WIRING TO POOL LIGHT IN APPROVED CONDUIT UL APPROVED DECK BOX FOR DIRECT CONNECTION TO WET NICHE UNDERWATER LIGHT NOTE: POOL PUMP MOTOR LOCATED ABOVE GRADE. PROVIDE SEPARATE CIRCUIT FOR PUMP MOTOR(S)AND HEATER(S) ETC(NO SCALE) RAIN TIGHT OUTDOOR ELECTRICAL PANEL (SIZED PER LOAD) APPROVED WIRING IN 1" SCH 40 PVC W/ #8 BONDING CONDUCTOR POOL LIGHT SWITCH EITHER INDOOR OR OUTDOOR G.F.I OUTLET NOTE: INSTALL 125V 15 AMP WEATHERPROOF DUPLEX RECEPTACLE AT LEAST 10' AWAY AND NOT MORE THAN 20' FROM THE INSIDE WALL OF THE POOLOUTDOOR TIME-CLOCK PUMP MOTOR ELECTRICAL DIAGRAM AND GFI OUTLET PER 2017 NEC · NOTES: · (1) POOL PANEL AND SWITCHES MUST BE AT LEAST 5' FROM THE INSIDE WALL OF THE POOL · · (2) ALL ELECTRICAL WIRING AND EQUIPMENT MUST INSTALLED IN ACCORDANCE WITH THE 2017 EDITION OF THE NATIONAL ELECTRICAL CODE · · (3) PROVIDE PROPER WORKING CLEARANCE SPACES FOR ELECTRICAL EQUIPMENT AS PER HO-26 OF NFPA 70 BURIED POWER LINES SAFETY BARRIER PER FBC R4501.17.1- R4501.17.3 & ASTM5034-95, ASTM D3787- 89, ASTM 653-96 POOL BARRIER PER FBC R4501.17.1- R4501.1.17.3 AND ANSI/NSPI-5-1995 RETURN LINE WASTE SKIMMER PIPING SCHEMATIC (NO SCALE) HAIR & LINT CATCHER (COMPONENT OF PUMP) MUST HOLD 35 PSI FOR AT LEAST 30 MIN. PRESSURE GAUGEFILTER (2) MAIN DRAINS MIN. 3' APART PUMP 6"X6" TILE INTERIOR FINISH 1 " PAVER POOL PATIO STEEL-TEX FORM OR KRAFT WALL #3 @ 12" O.C.B.W. NOTE: FOR DEPTHS GREATER THAN 6' ADD 1- #3 COVE BAR @ 6" O.C. TO PUMP THREADED PLUG GRATE SHALL BE SECURED IN PLACE SO THAT TOOLS ARE REQUIRED FOR REMOVAL GRAVEL BED NOTE: REMOVE GRATE & WELL POINT PLUG FROM MAIN DRAIN & ATTACH AUX. PUMP LINE WHEN EMPTYING POOL TYPICAL WALL SECTION & WELL POINT (NO SCALE) RAIL FENCE BY PRINCE DEVELOPMENT SWIMOUTS WHEN PROVIDED SHALL BE AT 20" MAX. BELOW THE WATERLINE 18" N.T.S. Per F.R.C. 4501.18 AND ANSI/ NSPI-5-2003 20" max. 2' 30' 6.5' 17'8" CYCOLAC MAIN DRAIN LIGHT 1 ROW OF WATERLINE TILE #3 STEEL @ 12" O/C E.W. 6" THICK TYPICAL SECTION THRU POOL WATERLINE DECK WALLS SHALL NOT SLOPE GREATER THAN 11 FLOOR SLOPES FLOOR SLOPES SHALL BE REASONABLY UNIFORM AND COMPLY WITH ARTICLES 5.6.1 THRU 5.6.3 THE SLOPE OF THE FLOOR FROM THE SHALLOW END WALL TOWARDS THE DEEP AREA SHALL NOT EXCEED 1 FOOT IN 7 FOOT (NO SCALE) 4 ½” THICK 4' DECK, DECO DRAIN INSTALL, MUD SET BORDERS THROUGH OAKMONT BY TAURUS CONSTRUCTION. DAVE: 772-646-1610 N.T.S. N.T.S. N.T.S. N.T.S.N.T.S. TO THE BEST OF MY KNOWLEDGE, THESE DRAWINGS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES AARON H. ALLEN PE, FL REG. NO. 86620 FL A. ALLEN ENGINEERING LLC, CA NO. 33042, 2367 7TH STREET, LA VERNE, CA, 91750 LOCATION OF WATER BOND PB-2008 WATER DECK BONDING WIRE TO GRID POOLBOND PB-2008 N.T.S. UNBLOCKABLE CHANNEL DRAIN SPA DETAIL 8 FPS MAX 3" SUCTION LINE TO MAX 181 G.P.M. APPROVED MAIN DRAIN FRAMES AND GRATES PER V.G.B. ASME/ANSI 112.19.8-2007 3" SUCTION LINE 181 GPM MAX TO JET PUMP TO FILTRATION PUMP8 FPS MAX 2.5" RETURN LINE TO JETS 2.5" RETURN TO FIRST TEE · APPROVED WITH THE 2017 FLORIDA BUILDING CODE 6th EDITION FOR RESIDENTIAL AND THE ANSI/APSP-7 2006 FOR SUCTION ENTRAPMENT AVOIDANCE N.T.S. N.T.S. HIGH SPEED LOW SPEED JANDY PRO SERIES VS FloPro Series Pump VS-FHP2.7 Performance Curve CONSTRUCTION CONTACT FOR OAKMONT IS MICHAEL TRAPANI. CELL: 772-215-3218 TRAVERTINE POOL PATIO WATERLINE SPA WALL SECTIONTILE ON SPA BEAM #3 @ 12" O.C.B.W. (1) CHANEL DRAIN AND GRATE SHALL BE SECURED IN PLACE SO THAT TOOLS ARE REQUIRED FOR REMOVAL STEEL-TEX FORM OR KRAFT WALL 4 ½” TYP. WALL (NO SCALE)6"X6" TILE SPA BENCH 18" BELOW WATERLINE TO PUMP GRAVEL BED N.T.S. SAND SET TRAVERTINE DECK 1 2 " 8" ILLUSION SPA TROUGH 5 f t . 7 ft. 3 ft. WOOD BALCONY WALKWAY BY OTHERS 4' DEEP TILED STEP EDGES SKIMMER, AUTOFILL, OVERFLOW 6.5' DEEP TILED BENCH EDGE COLOR LED VAC LINE COLOR LEDCOLOR LED 36 SQ FT ILLUSION SPA RAISED 12" ABOVE WATERLINE, 8 HYDRO THERAPY JETS, JANDY RS4 AUTOMATION SYSTEM, JANDY 400K BTU GAS HEATER STEP 3 0 f t . 9 i n . 1 9 f t . 4 i n . 2 8 f t . 1 9 f t . X=DOORWINDOW ALARMS AS CHILD SAFETY BARRIER DECO DRAIN 5 f t . 48" HIGH ALUMINUM RAIL FENCE CORE DRILLED INTO STEM WALL AS REQUIRED BY CODE WITH 1 GATE 2'X4' INTERIOR DIMENSION MANUAL START FIRE PIT WITH TRAVERTINE EXTERIOR, BLUE FIRE GLASS, RAISED 24", GAS HOOKUP THROUGH BUILDER POOL DETAIL MINIMUM (2) SUCTION LINES PER PUMP 3 FT. SEPARATION OR SEPARATE PLANES 3 FT. MIN. 8 FPS MAX 6 FPS MAX 3" SUCTION MAX 181 GPM 3" PLUMBING LINES FROM SUMP W/ 3" TEE APPROVED MAIN DRAIN FRAMES AND GRATES PER V.G.B. ASME/ANSI 112.19.8-2007 TO FILTRATION PUMP 2.5" RETURN TO FIRST TEE APPROVED WITH THE 2017 FLORIDA BUILDING CODE 6TH EDITION FOR RESIDENTIAL AND THE ANSI/APSP-7 2006 FOR SUCTION ENTRAPMENT AVOIDANCE N.T.S. N.T.S. 8 ft. 4 in.14 ft. 8 in. 5 f t . 2 f t .7 ft. 2 ft.5 ft.3 ft. 3 f t . 1 2 f t . 7 i n . 30 ft. 10'4" JANDY RS4 IAQUALINK AUTOMATION 2 4 " 2' CONCRETE FIRE PIT DETAIL 6" 2 4 " 6" MANUAL ELEMENT WITH FIRE GLASS INTERIOR MEDIA #3 REBAR MINIMUM 3" COVER TILED EXTERIOR TRAVERTINE COPING 1.5"1"1" N.T.S. POOL DECKPOOL DECK (2) 1" DRAIN LINES (1) 1.5" GAS LINE 6 f t . 9 i n . 5 f t . 2 i n . 0 ft. 8 in. 7 f t . 1 0 i n . 5 ft. 3 f t . 6 i n . 3 f t . R R R RS4 R R HH H H H H H H 3" 1" 1" 2.5"2.5" 1" 1.5" 1"1.5" 1"1.5"2.5" 2" 1.5" 1" 3" 1.5" X XX X X XXX LEGEND 1. 1.5" VACUUM LINE 2. 3" POOL MAIN DRAIN 3. 2" SKIMMER LINE 4. 2.5" POOL RETURN LINE TO FIRST TEE, 1.5" TO POOL 5. 2.5" RETURN TO SPA 6. 2.5" RETURN TO HYDRO JETS 7. 3" JET SUCTION A. 1.5" TO WASTE OR DISCHARGE TO GROUND B. 2.7HP JANDY VARIABLE FHPM PUMP WITH W/APPR HAIR AND LINT STRAINER C. 2HP JANDY JET PHPM PUMP WITH W/APPR HAIR AND LINT STRAINER D. CARTRIDGE FILTER W/ PRESSURE GAUGE AND AIR RELIEF VALVE E. VALVES (TYPICAL) F. INSTALL PERMA-CAST WATER BOND OR APPROVED EQUAL TIED TO PUMP GROUND W/ #8 SOLID COPPER & APPROVED LUG (MIN. 9 SQ. IN SURFACE AREA EXPOSED TO WATER) PER MFGR’S SPECS (FIELD VERIFY LOCATION) G. JANDY 400K BTU PROPANE GAS HEATER H. JANDY TRUE CLEAR SALT SYSTEM EQ EQUIPMENT PAD PER FBC 4501.22(9.2) POOL EQUIPMENT ANCHORED PER FLORIDA BUILDING CODE 2017 &R4501.22 F P P H EQ. LAYOUT NO SCALE 30" CLEARANCE IN FRONT OF SUBPANEL EQUIPMENT PAD PER FBC 4501.22(9.2) VERIFY EXACT LOCATION OF EQ PAD WITH SUPERVISOR SALT S.P.S.T. TOGGLE SWITCH ELECTRICAL DIAGRAM 1. ALL ELECTRICAL TO COMPLY WITH 2017 NATIONAL ELECTRIC CODE. 2. 3-#12 THHN CU WITHIN ½” MIN. CONDUIT FOR POOL LIGHT (S) 3. GROUND ALL BOXES, LIGHTS, MOTORS, ETC, WITH #8 SOLID, BARE COPPER. 4. ALL POOL PUMPS TO GFCI PROTECTED PER NEC 680.22 (B) N.T.S. (1) SPA LIGHT IF APPLICABLE (GFI NOT REQUIRED) #8 SOLID CU GROUND WIRE TO EXISTING PANEL 60 AMP POOL PANEL W/(3) - #4 THHN CU WITHIN ¾” ELECTRICAL CONDUIT (3) POOL LIGHTS (GFI NOT REQUIRED) 2HP JANDY PLUS HP PUMP MOTOR W/BUILT- IN OVERLOAD SWITCH W/3- #10 THHN CU WITHIN ½” MIN. CONDUIT MANUAL MOTOR SWITCH VARIABLE SPEED FLOPRO PUMP MOTOR W/BUILT-IN OVERLOAD SWITCH W/3- #10 THHN CU WITH-IN ½” CONDUITTIME CLOCK W.P. DISCONNECT HEATER (GAS) IGNITIION SWITCH 3- #12 THHN CU WITHIN ½” CONDUIT (CONNECT TO 20 AMP-1 POLE GFCI BREAKER) · NOTES: · (1) POOL PANEL AND SWITCHES MUST BE AT LEAST 5' FROM THE INSIDE WALL OF THE POOL · · (2) ALL ELECTRICAL WIRING AND EQUIPMENT MUST INSTALLED IN ACCORDANCE WITH THE 2017 EDITION OF THE NATIONAL ELECTRICAL CODE · · (3) PROVIDE PROPER WORKING CLEARANCE SPACES FOR ELECTRICAL EQUIPMENT AS PER HO-26 OF NFPA 70 5. PROVIDE W.P.G.F.I. OUTLET 10' MIN. -20' MAX. FROM WATER’S EDGE. G A 4 B 1 23 EQUIPMENT LAYOUT N.T.S. 6 PIPING SCHEMATIC E F D C 7 5 H GENERAL NOTES: 1. SWIMMING POOL CONSTRUCTION TO COMPLY W/ FLA. BLDG. CODE AND WITH ALL LOCAL ORDINANCES AND ZONING REGULATIONS. 2. SWIMMING POOL TO BEAR ON ROCK OR UNDISTURBED SAND. ALL WALLS AND FLOORS SHALL BE GUNITED OR POURED IN- PLACE CONCRETE W/ MINIMUM 3,000 P.S.I. CONCRETE (@ 28 DAYS) COMPRESSIVE STRENGTH. 3. ENGINEER SHALL BE NOTIFIED IF SOIL BEARING LESS THAN 2500 P.S.F., OR MUCK, SILT OR LOOSE, SOFT SOIL IS FOUND. A SOIL BEARING CAPACITY OF 2,500 P.S.F. HAS BEEN USED IN THE DESIGN. 4. REINFORCING BARS SHALL BE NEW BILLET, GRADE 40. 5. ALL POOL PIPING TO BE P.V.C. SCHEDULE 40 MIN. AND BEAR THE N.S.F. APPROVAL. 6. BACK-WASH SHALL BE IN COMPLIANCE WITH LOCAL ORDINANCES. 7. DISPOSAL OF POOL WATER SHALL CONFORM TO LOCAL ORDINANCES. SURFACE GRADING SHALL CONTAIN WATER WITHIN PROPERTY LINES. PONDING SHALL NOT PERSIST FOR MORE THAN ONE HOUR. 8. WATER SUPPLY & DISPOSAL SHALL BE INSTALLED SO THAT THERE IS NO CROSS CONNECTION WITH A DOMESTIC WATER SUPPLY OR WATER DISPOSAL SYSTEM. 9. GRATE AT MAIN DRAIN SHALL HAVE A FREE AREA OF 4X THE AREA OF THE SUCTION LINE 10. HAIR & LINT STRAINERS SHALL HAVE A REMOVABLE SCREEN W/ A MINIMUM FREE AREA OF 3X THE AREA OF THE SUCTION LINE. 11. ELECTRICAL: INSTALL WIRING & DEVICES AS SHOWN IN "POOL DATA" HEREON. LIGHT CONNECTION TO CONFORM TO NATIONAL ELECTRICAL CODE- LATEST EDITION. 12. ALL METALLIC CONDUITS, PIPING SYSTEMS, REINFORCED STEEL, LIGHT FIXTURES & HOUSING, METAL PARTS OF LADDERS, HANDRAILS, DIVING BOARDS & SUPPORTS TO BE BONDED TOGETHER & GROUNDED TO A COMMON GROUND. BONDING CONDUCTOR SHALL NOT BE SMALLER THAN #8 COPPER. 13. NO OVERHEAD OPEN WIRE OVER POOL WATER. 14. CARTRIDGE FILTER SHALL HAVE A FILTRATION RATE NOT TO EXCEED 3 G.P.M. / S.F. OF FILTER AREA. NO BACK-WASH REQUIRED. 15. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT SITE BEFORE STARTING THE PROJECT. CONTRACTOR SHALL VERIFY LOCATION OF ELECTRICAL SERVICE BY F.P.&L. COMPANY. 16. SPECIAL ATTENTION SHALL BE GIVEN TO EXISTING FOUNDATION TO PREVENT UNDERMINING. 17. PLANTER SPECIES SHALL BE SELECTED WITH NON-INVASIVE ROOT SYSTEMS (SPECIES SELECTION BY OTHERS) THERAPY PUMP = 2HP JANDY STEALTH PLUS PHPM LOW SPEED = 36 GPM MAX. HIGH SPEED = 144 GPM @ 44 TDH MAX. 3" SUCTION PIPE @ 147 GPM = 7.29 FT./SEC. (8FT./SEC. MAX. – SUCTION LINES) 2.5" PRESSURE PIPE @ 147 GPM = 7.99 FT./SEC. (10 FT./SEC. MAX. – PRESSURE LINES) ANSI-7/ANSI-15 WATER FEATURE PUMP = 2.7HP JANDY VARIABLE FLO PRO VARIABLE SPEED LOW SPEED – 36 GPM MAX HIGH SPEED = 117 GPM @ 48 TDH 3" SUCTION PIPE @ 117 GPM = 5.63 FT/SEC. (8 FT./SEC. MAX. – SUCTION LINES) 3" BRANCH PIPE @ 60 GPM = 4.13 FT./SEC. (6 FT./SEC. MAX. – PRESSURE LINES) 2.5" PRESSURE PIPE @ 117 GPM = 8.43 FT./SEC. (10 FT./SEC. MAX. – PRESSURE LINES) 200 SQ. FT. CARTRIDGE FILTER X 0.375 = 75 GPM BACKWASH VALVE NO 4 1 f t . 1.5"1"1" N.T.S. 1 2 " 1 2 " (3) #3 REBAR 12" O.C.E.W. 3"