Loading...
HomeMy WebLinkAboutRevisionOFFICE USE ONLY: DATE FILED: REVISION FEE: LOCATION/SITE PERMIT # _ RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34962-5652 (772)462-1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION DETAILED DESCRIPTION OF PROJECT CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: CGC1513137 BUSINESS NAME: Houses By Vicki LLC QUALIFIERS NAME: Victoria Strickler ADDRESS: 2710 MAJESTIC OAKS COURT CITY: Plant City STATE: I-L ZIP: 33566 PHONE (DAYTIME): 813-967-0731 FAX: 813-262-1964 OR'NER/BUILDER INFORMATION: NAME: ADDRESS: CITY: PHONE (DAYTIME: ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: PHONE (DAYTIME): SLCCC: 9123109 Revised 06130117 ST. LUCIE CO CERT. #: 31409 STATE: ZIP: FAX: I SIES 3EN�tt'E� EN�'n_�g�FYY&74FG s��kt.'i��� An Engineering and Design ompany 50 W. Central Ave, Suite B - Lake Wales, FL 33853 - Office: 863.589.5980 Fax: 1(866) 865.2044 - Email: mbvnes senyben ing eering com May 11, 2020 Site Address: XXXX Southwind Trail Ft. Pierce, FL 34951 Subject: Additional Tie -down Method Dear Building Official: The provided foundation engineering plan requires Simpson's HETA 16 straps to be installed at 4'-0" on -center along sidewalls, endwalls, mateline (alternating sides) and within 12 inches of corners. In addition, each strap requires a minimum of (9) l Od x 1-1 /2" nails. Given that the modular structure is extending beyond the foundation by approximately 1-inch, the straps were bent (901) to allow for the installation of the straps to the perimeter joists and the sill plate. As a result, an additional Simpson's FJA strap shall be added on the inside of the foundation to replace each HETA 16 installed incorrectly. The FJA shall be installed as shown in the figure below: Figure 1: Simpson Strong -Tie FJA Installation Each FJA shall be nailed to the floor joist using (8)l Od x 1-1/2" nails and anchored to the foundation lintel block using (2) %:" x 5-1/2" wedge anchors. The FJA may be bent along bend line up to 20 degrees to accommodate installation. If you have any additiopal questions, please contact me directly. Sincerely No.C561 4F : p °: STATE OF %oFSS F� OR /0NAL , Mark Vincent Richter, P.E. #56196 To: Whom it may concern From: Brad Lipphardt Quality Assurance Manager Skyline Corp., Homette Division Re: Center Seal To Whom It May Concern, SKYLINE CORPORATION HONIETTE DIVISION #53 1230 S.W. 10" St. OCALA, FL 34478-2648 (352)629-7571 May 22, 2020 The double wide unit, serial number FL239-000-M-A010507AB for customer Cole (as well as every Skyline home regardless of it being a Modular or HUD variation) was constructed in the factory with Center Seal CSI-500 installed, per manufacturer's instructions, at the centerline at the floor, walls, and ridge beam to create a seal. Brad Lipphardt Quality Assurance Manager