APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
DETAILED DESCRIPTION OF PROJECT
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: CGC1513137
BUSINESS NAME: Houses By Vicki LLC
QUALIFIERS NAME: Victoria Strickler
ADDRESS: 2710 MAJESTIC OAKS COURT
CITY: Plant City STATE: I-L ZIP: 33566
PHONE (DAYTIME): 813-967-0731 FAX: 813-262-1964
OR'NER/BUILDER INFORMATION:
NAME:
ADDRESS:
CITY:
PHONE (DAYTIME:
ARCHITECT/ENGINEER INFORMATION:
NAME:
ADDRESS:
CITY:
PHONE (DAYTIME):
SLCCC: 9123109
Revised 06130117
ST. LUCIE CO CERT. #: 31409
STATE: ZIP:
FAX:
I SIES
3EN�tt'E� EN�'n_�g�FYY&74FG s��kt.'i���
An Engineering and Design ompany
50 W. Central Ave, Suite B - Lake Wales, FL 33853 - Office: 863.589.5980
Fax: 1(866) 865.2044 - Email: mbvnes senyben ing eering com
May 11, 2020
Site Address: XXXX Southwind Trail
Ft. Pierce, FL 34951
Subject: Additional Tie -down Method
Dear Building Official:
The provided foundation engineering plan requires Simpson's HETA 16 straps to be installed at 4'-0" on -center
along sidewalls, endwalls, mateline (alternating sides) and within 12 inches of corners. In addition, each strap
requires a minimum of (9) l Od x 1-1 /2" nails.
Given that the modular structure is extending beyond the foundation by approximately 1-inch, the straps were
bent (901) to allow for the installation of the straps to the perimeter joists and the sill plate. As a result, an
additional Simpson's FJA strap shall be added on the inside of the foundation to replace each HETA 16 installed
incorrectly. The FJA shall be installed as shown in the figure below:
Figure 1: Simpson Strong -Tie FJA Installation
Each FJA shall be nailed to the floor joist using (8)l Od x 1-1/2" nails and anchored to the foundation lintel block
using (2) %:" x 5-1/2" wedge anchors. The FJA may be bent along bend line up to 20 degrees to accommodate
installation.
If you have any additiopal questions, please contact me directly.
Sincerely
No.C561
4F :
p °: STATE OF
%oFSS F� OR
/0NAL ,
Mark Vincent Richter, P.E. #56196
To: Whom it may concern
From: Brad Lipphardt
Quality Assurance Manager
Skyline Corp., Homette Division
Re: Center Seal
To Whom It May Concern,
SKYLINE CORPORATION
HONIETTE DIVISION #53
1230 S.W. 10" St.
OCALA, FL 34478-2648
(352)629-7571
May 22, 2020
The double wide unit, serial number FL239-000-M-A010507AB for customer Cole (as
well as every Skyline home regardless of it being a Modular or HUD variation) was
constructed in the factory with Center Seal CSI-500 installed, per manufacturer's
instructions, at the centerline at the floor, walls, and ridge beam to create a seal.
Brad Lipphardt
Quality Assurance Manager