HomeMy WebLinkAboutPermit WorksheetsMobile Home Permit Worksheet
Installer: eddie grundel License # IH1118467
Address of home 754 NWTTLES BLVD
being installed
Manufacturer JACOBSEN Length xwidth 20X35/39
NOTE: if home is a single wide rill out one half of the blocking plan
if home is a triple or quad wide sketch in remainder of home
I understand Lateral Arm Systems cannot be used on any home (new or used)
where the sidewall ties exceed 5 ft 4 in.
Installers initials EG
Typical pier spacing %
6' / 11"rat
2' L�
Application Number." -
New Home 0 Used Home
Home installed to the Manufacturer's Installation Manual
Home is installed in accordance with Rule 15-C
Single wide Wind Zone II Wind Zone III
Double wide Q Installation Decal # TBD
Triple/Quad Serial # TBD
PIER SPACING TABLE FOR USED HOMES
B
0
Load
bearing
capacity
Footer
size
(sq in)
16" x 16"
(256)
18 1/2" x 18
1/2'(342)
20" x 20"
(400)
22" x 22"
(484)•
24" X 24"
(576)•
26" x 26"
(676)
000 osf
3
4
5
0 ps
8
s
6
8
8
s
8.
3000 pst8
8
s
8
8
mcerporacea from nwe i oi� i pier spacing came.
PIER PAD SIZES
I-beam pier pad size 17X22.5
Perimeter pier pad size 16X16
Other pier pad sizes
(required by the mfq.)
r- -r Draw the approximate locations of marriage
wall openings 4 foot or greater. Use this
1 ••) symbol to show the piers.
List all marriage wall openings greater than 4 foot
and their pier pad sizes below.
Opening Pier pad size
14 17X22.5
24
90,
SUM
i[-ERg G�W1*1l
irs's�N
MEMMEK-21MINU
M.
00MFIil1.F1i�
- r
r
fik7i[ �Yc1iC:lMME
fYflf'3'i�b'ilf".�Lr.•M
Ifi�krszloil
(:�
ANCHORS
4ft _V"_5ft_
FRAME TIES
within 2' of end of he --
spaced at 5' 4" oc _ _
TIEDOWN COMPONENTS OTHER TIES
Number
Longitudinal Stabilizing Device (LSD) Sidewall
Manufacturer OLIVER Longitudinal
Longitudinal Stabilizing Device w/Lateral Arms Marriage wall
Manufacturer Shearwall
23X31
Mobile,Home Permit Worksheet Application Number: ' I Date:
POCKET PENETROMETER TES
The pocket penetrometer tests are rounded down to 1500 psf
or check here to declare 1000 lb. soil without testing.
X 1,500 X 1,500 X 1,500
POCKET PENETROMETER TESTING METHOD
1. Test the perimeter of the home at 6 locations.
2. Take the reading at the depth of the Tooter.
3. Using 500 lb. increments, take the lowest
reading and round down to that increment.
X 1,500 X 1,500 X 1.500
TORQUE PROBE TEST
The results of the torque probe test is 289 inch pounds or check
here if you are declaring 5' anchors without testing . A test
showing 275 inch pounds or less will require 5 foot anchors.
Note: A state approved lateral arm system is being used and 4 ft.
anchors are allowed at the sidewall locations. I understand 5 ft
anchors are required at all centerline tie points where the torque test
reading is 275 or less and where the mobile home manufacturer may
requires anchors with 4000 lb holding capacity.
Installer's initials
ALL TESTS MUST BE PERFORMED BY A LICENSED INSTALLER
Installer Name eddie
Date Tested
Electrical
Connect electrical conductors between multi -wide units, but not to the main power
source. This includes the bonding wire between mutt -wide units. Pg.
Plumbina
Connect all sewer drains to an existing sewer tap or septic tank. Pg.
Connect all potable water supply piping to an existing water meter, water tap, or other
independent water supply systems. Pg.
Site Preparation
Debris and organic material removed YES
Water drainage: Natural Swale Pad X Other
Fastening multi wide units
Floor: Type Fastener: LAG Length: 6" Spacing: 24"
Walls: Type Fastener. LAG Length: 6" Spacing: 24"
Roof: Type Fastener: LAG Length: 6" Spacing: 94"
For used homes a min. 30 gauge, 8" wide, galvanized metal strip
will be centered over the peak of the roof and fastened with galy.
roofing nails at 2" on center on both sides of the centedine.
Gasket (matherpmfing mqulmmen)
I understand a properly installed gasket is a requirement of all new and used
homes and that condensation, mold, meldew and buckled marriage walls are
a result of a poorly installed or no gasket being installed. I understand a strip
of tape will not serve as a gasket.
Installer's initials _
Type gasket FOAM Installed:
Pg. Between Floors Yes X
Between Walls Yes X
Bottom of ridgebeam Yes X
Weatherproofing
The bottomboard will be repaired and/or taped. Yes . Pg.
Siding on units is installed to manufacturer's specifications. Yes X
Fireplace chimney installed so as not to allow intrusion of rain water. Yes X
Miscellaneous
Skirting to be installed. Yes X No
Dryer vent installed outside of skirting. Yes X N/A
Range downflow vent installed outside of skirting. Yes X N/A
Drain lines supported at 4 foot intervals. Yes X
Electrical crossovers protected. Yes X
Other:
Installer verifies all information given with this permit worksheet
is accurate and true based on the
manufacturer's installation instructions and or Rule 15C•1 & 2
Installer Signature
Page 2 of 2