Loading...
HomeMy WebLinkAboutANDOCHICK ENGINEERINGENGINEERING & TESTING, INC. Phone: (866) 781-6889 •Fax: (866) 784-8550 trrcu,.florid aengineeringandte s ting.com 250 S.W. 13"' Avenue Pompano Beach, FL 33069 DATE: 5/27/20 JOB ORDER #: 20-2048Rev. CLIENT: Onshore RoofinE ADDRESS: 4401 S.E. Commerce Avenue Stuart Florida 34997 PROJECT: Andochicic Residence Sloped Tile Roof Deck ADDRESS: 13008 NW Harbor Ridee Palm City, Florida 2017 FBC/ASCE-7 DESIGN PRESSURE CALCULATIONS Proieet Information: Mean Roof Height = 30' Exposure: C Basic/Ultimate Wind Speed: V„i,=170 mpli Length = 60' Category: II Nominal Wind Speed: Vasd=V1,*110.6 Width = 40' Slope: 6/12 (asd = allowable strength design) Parapet Wall: N/A Residential K� = 0.98, KA = 1.0, Kd = 0.85 Desien Calculations: Velocity Pressure: q = 0.00256*KX�,KdV2 Velocity Pressure (,d,): q=0.00256(0.98)(1.0)(0.85)(170)2] = 61.63 psf Velocity Pressure (asd): q=0.00256(0.98)(1.0)(0.85)(170*40.6)2] = 36.98 psf Width of Pressure Coefficient: Effective Wind Area: <10ft2 0.1(40') = 4.0' 0.4(30') = 12.0' } use: 4'0" For hip roofs with a roof slope of 25 degrees or less, zone three (3) shall be treated as zone two (2). External Pressure Coefficient: Internal Pressure Coefficient: 1) GCP1 = -0.9 1) GCP; = 0.18 2) GCP2 = -1.7 3) GCP3 = -2.6 Design Pressures Based on Vasd: 1) Field PI = 36.98*[(-0.9)—(0.18)]=-39.9psf 2) Perimeter P2 = 36.98*[( -1.7) — (0.18)] = -69.5 psf 3) Corners P3 = 36.98*[(-2.6)—(0.18)]=-102.8psf Attachment Requirements Per RAS 127: The system is acceptable as approved based on the requirements of Florida Product Approval # FL7804-R10 for adhering the Entegra Estate "S" low/medium profile clay/concrete tile with independent large single paddy ICP foam adhesive to the self adhered Polystick TU Max (back - nailed within the selvedge -edge side laps using 12 ga. x 1-1/4" ring shank nails through 32 ga., I- 5/8" diameter tin caps spaced 12" o.c.) to the min. 15/32" plywood deck (primed with WB -3000). Section 6.3.3 of the tile product approval references Tables 2A or 2B and IA of the FRSA/TRI April 2012 for the required uplift moment and required design pressure, respectively.. Ih� X11 vQ U (lrraiity �tj A iy ✓Ys rwanee Page 2,5127/20, Job Order #20-2048 Revised Onsbore Roofing - Adochick Residence 13008 NW Harbor Ridge; Palm City, Florida: FLO A Per Table 2A of the FRSA/TRI April 2012 for Tile: Required Aerodynamic Uplift Moment (Ma) = 37.5ft-Ibf; for Zone 3, Exposure C, basic wind speed of 170mph, mean roof height of 30', and roof pitch of 6/12 or less Per Table I of ICPAdhesivePolyset Product Approval # FL 6332-R8: Allowable Overturning Moment = 67ft-Ibf; for a low/medium profile clay/concrete tile adhered with independent large (2"x10", approx. 54grams) single paddy ICP Adhesive Required Aerodynamic Uplift Moment < Allowable Overturning Moment 37.5ft-lbf < 67ft-Ibf ACCEPTABLE Per Table IA of the FRSAITRIApri12012 for Underlayment: Required Design Pressure = 102.8psf; for mean roof height of 30', exposure C, basic wind speed of 170mph, category II building having a 2:12 and greater pitch Per Page 6 Option 4 of Polyglass Roof Underlayments Product Approval # FL 5259-R29: Maximum Design Pressure=105psf; for self adhering the Polystick TU Max (back -nailed within the selvedge -edge side laps using 12 ga. x 1-1/4" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12" o.c.) to the min. 15/32" plywood deck (primed with WB -3000) Required Design Pressure < Maximum Design Pressure 102.8psf < 105psf ACCEPTABLE therefore, the system is acceptable as approved for ALL roof zones for adhering the Entegra Estate "S" low/medium profile clay/concrete tile with independent large singe paddy ICP foam adhesive to the self adhered Polystick TU Max (back -nailed within the selvedge -edge side laps using 12 ga. x 1-1/4" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12" o.c.) to the min. 15/32" plywood deck (primed with WB -3000) based on the requirements of Florida Product Approval # FL7804-R10 and FRSA/TRI. Notes: • Corners and perimeter area dimension shall not be less than a = 4'0" • Contractor to verify that the fastening patterns meet manufacturer's requirements for issuance of a warranty (as applicable). • All work shall be in compliance with the local building code product control notice of acceptance and manufacturer specifications and Florida Building Code 2017 Edition. • Wad load calculations based on ASCE-7, 2017 FBC, and information provided by client. Client is responsible for verifying existing/proposed conditions/decks as it pertains to the above provided product approval. • All work shall be insp��g4,gd by our field engineer (or authorized representative) or a building department ins 21r )R�vg "ppliance with specifications. Sincerely, °�P 0 k1 ,ys;,�s�';; * No 42-- -- -00.7.14 0= Mark A. Mesfat(9, P.I,.. "y/E n, * Florida Engin Florida Reg. T Certificate of