HomeMy WebLinkAboutaNDOCHICK ENTEGRA 2017 EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
(203) 262-9245
EVALUATION REPORT
Entegra Roof Tile, LLC
1289 NE 9th Avenue
Okeechobee, FL 34972
(602) 515-6933
Evaluation Report E39310.11.11-2-R5
FL7804-R10
Date of Issuance: 11/02/2011
Revision 5 : 10/17/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code (non-
HVHZ) sections noted herein.
DESCRIPTION: Entegra Concrete Roof Tiles (non-HVHZ jurisdictions)
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. Trinity|ERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words “Trinity|ERD Evaluated” may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized by Robert
Nieminen, P.E. on 10/17/2017. This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. Trinity|ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity|ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing produ cts for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval proc ess of the
product.
5. This is a building code evaluation. Neither Trinity|ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless r etained
specifically for that purpose.
Exterior Research and Design, LLC. Evaluation Report E39310.11.11-2-R5
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL7804-R10
Entegra Roof Tiles Revision 5: 10/17/2017
Page 2 of 6
ROOFING SYSTEM EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Roofing Tiles
Compliance Statement: Entegra Concrete Roof Tiles, as produced by Entegra Roof Tile, LLC, have demonstrated
compliance with the following sections of the 6th Edition (2017) Florida Building Code through testing in accordance
with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of
Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.3.5, R905.3.5 Physical Properties ASTM C1492 2003(2009)
1507.3.7, R905.3.7 Attachment Requirements FRSA/TRI April 2012 (04-12) 2012
1504.2.1.1 Overturning Moment SSTD 11 1997
3. REFERENCES:
Entity Examination Reference Date
ATL (TST3782) Physical Properties RT0615.01-11 06/28/2011
ATL (TST3782) Physical Properties RT0615.02-11 06/28/2011
ATL (TST3782) Physical Properties RT0615.03-11 06/28/2011
ATL (TST3782) Physical Properties RT0615.04-11 06/28/2011
ATL (TST3782) Physical Properties RT0615.05-11 06/28/2011
ATL (TST3782) Physical Properties RT0316.01-12 05/31/2012
ATL (TST 3782) Physical Properties RT1103.01-15 11/07/2015
ATL (TST 3782) Physical Properties RT1103.02-15 11/07/2015
ATL (TST 3782) Physical Properties RT1103.03-15 11/07/2015
ATL (TST 3782) Physical Properties RT1103.04-15 11/07/2015
ATL (TST 3782) Physical Properties RT1103.05-15 11/07/2015
PRI (TST5878) Physical Properties ESI-001-02-01 11/06/2006
PRI (TST5878) Physical Properties ESI-002-02-01 11/06/2006
PRI (TST5878) Physical Properties ESI-003-02-01 11/06/2006
PRI (TST5878) Physical Properties ESI-004-02-01 11/06/2006
PRI (TST5878) Physical Properties ESI-005-02-01 12/12/2006
PRI (TST5878) Physical Properties HRT-023-02-01 11/19/2007
PRI (TST5878) Physical Properties HRT-026-02-01 01/08/2008
Tile Roof Institute SSTD 11 Membership Confirmation Current
PRI (QUA9110) Quality Assurance Service Confirmation Exp. 11/02/2018
Exterior Research and Design, LLC. Evaluation Report E39310.11.11-2-R5
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL7804-R10
Entegra Roof Tiles Revision 5: 10/17/2017
Page 3 of 6
4. PRODUCT DESCRIPTION:
4.1 ASTM C1492, Type III (low-profile) BERMUDA FLAT, PLANTATION FLAT and HORIZON FLAT
Bermuda Flat
Plantation Flat
Horizon Flat
Exterior Research and Design, LLC. Evaluation Report E39310.11.11-2-R5
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL7804-R10
Entegra Roof Tiles Revision 5: 10/17/2017
Page 4 of 6
4.2 ASTM D1492, Type II (medium-profile) BELLA HIGH “S”, ESTATE “S” and HACIENDA
Bella High “S”
Estate “S”
Hacienda
4.3 ASTM C1492, Type I (high-profile) GALENA SPANISH “S” and REGAL
Galena Spanish “S”
Regal
Exterior Research and Design, LLC. Evaluation Report E39310.11.11-2-R5
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL7804-R10
Entegra Roof Tiles Revision 5: 10/17/2017
Page 5 of 6
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity|ERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire classification is not part of this evaluation; refer to FBC 1505.2, Exception 2 (for non-combustible deck)
or listing by an approved testing agency for fire rating of this product.
5.4 Underlayment shall hold Florida Local or Statewide Product Approval for use with tile roofing systems. The
underlayment Product Approval shall specify allowable method(s) of tile installation (mechanical
attachment, mortar-set and/or adhesive-set) for use with the specific underlayment. For mortar-set or
adhesive-set tile roofing applications, the underlayment Product Approval shall specify attachment methods
for the underlayment system to resi st wind uplift design loads in accordance with Table 1A of FRSA/TRI April
2012 (04-12).
5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3.
6. INSTALLATION:
6.1 Entegra Concrete Roof Tiles may be mechanically fastened, mortar-set or adhesive-set. Installation shall
comply with manufacturer’s current published instructions, but not less than the requirements of FBC
1507.3, the FRSA/TRI April 2012 (04-12) and, for mortar-set or adhesive-set applications, the mortar or
adhesive manufacturer’s Product Approval.
6.2 Underlayment shall be installed in accordance with FRSA/TRI April 2012 (04-12) or the underlayment
manufacturer’s current Product Approval. For mortar-set or adhesive-set tile roofing applications, the
underlayment current Product Approval shall specify attachment methods for the underlayment system to
resist wind uplift design loads in accordance with Table 1A of FRSA/TRI April 2012 (04-12).
6.3 Attachment:
6.3.1 Mechanically Attached Tile:
Wind load resistance shall be in accordance with Table 3 of FRSA/TRI April 2012 (04-12) to resist the Uplift
Moment determined in Table 2A or 2B of FRSA/TRI April 2012 (04-12) or FBC 1609.5.3.
6.3.2 Mortar-Set Tile:
Wind load resistance shall be in accordance with Table 2A or 2B of FRSA/TRI April 2012 (04 -12) or FBC
1609.5.3 in conjunction with the mortar manufacturer’s Product Approval .
6.3.3 Adhesive-Set Tile:
Wind load resistance shall be in accordance with Table 2A or 2B of FRSA/TRI April 2012 (04-12) or FBC
1609.5.3 in conjunction with the adhesive manufacturer’s current Product Approval. Refer to the current
version of the referenced Florida Product Approval for paddy -placement details and performance data.
TILE ADHESIVES FOR ADHESIVE-SET TILE SYSTEMS
Manufacturer Product(s) Florida Product Approval
DAP Foam, Inc.
“Touch N’ Seal Storm Bond” FL14506
“Touch N’ Seal Storm Bond 2” FL21374
Dow Chemical “TILE BOND™” FL22525
ICP Adhesives & Sealants, Inc. “Polyset® AH-160” FL6332
Exterior Research and Design, LLC. Evaluation Report E39310.11.11-2-R5
Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL7804-R10
Entegra Roof Tiles Revision 5: 10/17/2017
Page 6 of 6
6.3.4 Hip and Ridge Tile:
Tile shall be installed in accordance with FRSA/TRI April 2012 (04-12). For hip and ridge tile installations
atop hip and ridge metal, refer to the hip and ridge metal manufacturer’s current Product Approval (e.g.,
FL5374) or test report in accordance with SSTD 11 for allowable loads to resist those determined in
accordance with Table 1A of FRSA/TRI April 2012 (04-12).
7. LABELING:
7.1 Each unit shall bear the imprint and/or identifiable marking of the manufacturer’s name or logo. Tile lots
shall be labeled in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to pr operly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Plant Profiles
Okeechobee, FL Bermuda Flat, Plantation Flat, Estate “S”, Bella High “S”, Galena Spanish “S”
Ft. Myers, FL Horizon Flat, Hacienda
Deerfield Beach, FL Horizon Flat, Hacienda, Regal
10. QUALITY ASSURANCE ENTITY:
PRI Construction Materials Technologies, LLC. – QUA9110; (813) 621-5777