Loading...
HomeMy WebLinkAboutARNOLD ENGINEERINGF1,0tt1X3A ENGINEERING & TESTING, INC. Phone: (866) 781-6889 *Fax: (866) 784-8550 www.floiidaengmeeringandtesting.com 250 S.W.13`h Avenue Pompano Beach, FL 33069 DATE: 5/22/20 JOB ORDER #: 20-2098 CLIENT: Onshore Roofing ADDRESS: 4401 S.E. Commerce Avenue Stuart, Florida 34997 PROJECT: Anderson Residence Sloped Tile Roof Deck ADDRESS: 8007 Plantation Lakes Drive Port Saint Lucie, Florida 2017 FBC/ASCE-7 DESIGN PRESSURE CALCULATIONS Proiect Information: Mean Roof Height = 20' Exposure: C Basic/Ultimate Wind Speed: VWc=170 mph Length = 81' Category: II Nominal Wind Speed: Vasa=Vuit*40.6 Width = 76' Slope: 6/12 (asd = allowable strength design) Parapet Wall: N/A Residential KZ = 0.90, Kzt = 1.0, Ka = 0.85 Design Calculations: Velocity Pressure: q = 0.00256*Kj<�.KaV2 Velocity Pressure (ult): q=0.00256(0.90)(1.0)(0.85)(170)2] = 56.60 psf Velocity Pressure (.d): q=0.00256(0.90)(1.0)(0.85)(170*40.6)2] = 33.96 psf Width of Pressure Coefficient: Effective Wind Area: <1 Oft 0.1(761) = 7.6' 0.4(20') = 8.0' } use: 8'0" For hip roofs with a roof slope of 25 degrees or less, zone three (3) shall be treated as zone two (2). External Pressure Coefficient: Internal Pressure Coefficient: 1) GCP 1 = -0.9 1) GCP; = 0.18 2) GCP2 = -1.7 3) GCP3 = -2.6 Design Pressures Based on Vasd: 1) Field P1 = 33.96*[( -0.9) - (0.18)] = -36.7 psf 2) Perimeter P2 = 33.96*[( -1.7) - (0.18)] = -63.8 psf 3) Corners P3 = 33.96*[( -2.6) - (0.18)] = -94.4 psf Attachment Requirements Per RAS 127: The system is acceptable as approved based on the requirements of Florida Product Approval # FL7473R8 for adhering the Eagle Bel Air flat profile clay/concrete tile with independent large single paddy ICP AH -160 foam adhesive to the self adhered Polystick TU Max (back -nailed within the selvedge -edge side laps using 12 ga. x 1-1/4" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12" o.c.) to the min. 15/32" plywood deck (primed with WB -3000). Section 6.3.3 of the tile product approval references Tables 2A or 2B and lA of the FRSA/TRI April 2012 for the required uplift moment and required design pressure, respectively. ! L.,' ` �1 Quality Q QA i8!.4murance '%* Cir'. f Page 2, 5/22/20, Job Order #20-2098 Onshore Roofing- Anderson Residence FLO A 8007 Plantation Lakes Drive; Port Saint Lucie, FL: Per Table 2A of the FRSAITRIApril2012 for Tile: Required Aerodynamic Uplift Moment (Ma) = 34.4ft-lbf; for Zone 3, Exposure C, basic wind speed of 170mph, mean roof height of 20', and roof pitch of 6/12 or less Per Table 1 of lCPAdhesive Polyset AH -160 Product Approval # FL 6332-R8: Allowable Overturning Moment = 112ft-lbf; for a flat profile clay/concrete tile adhered with independent large (2"x10", approx. 45grams) single paddy ICP AH -160 Adhesive Required Aerodynamic Uplift Moment < Allowable Overturning Moment 34.4ft-lbf < 112ft-lbf ACCEPTABLE Per Table IA of the FRSA%TRI April 2012 for Underlayment: Required Design Pressure = 94.4psf; for mean roof height of 20', exposure C, basic wind speed of 170mph, category II building having a 2:12 and greater pitch Per Page 6 Option 4 of Polyglass Roof Underlayments Product Approval # FL 5259-R29: Maximum Design Pressure = 105psf, for self adhering the Polystick TU Max (back -nailed within the selvedge -edge side laps using 12 ga. x 1-1/4" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12" o.c.) to the min. 15/32" plywood deck (primed with WB -3000) Required Design Pressure < Maximum Design Pressure 94.4psf < 105psf ACCEPTABLE therefore, the system is acceptable as approved for ALL roof zones for adhering the Eagle Bel Air flat profile clay/concrete tile with independent large single paddy ICP AH -160 foam adhesive to the self adhered Polystick TU Max (back -nailed within the selvedge -edge side laps using 12 ga. x 1-1/4" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12" o.c.) to the min. 15/32" plywood deck (primed with WB -3000) based on the requirements of Florida Product Approval # FL6332-118 and FRSA/TRI. Notes: • Comers and perimeter area dimension shall not be less than a = 8'0" • Contractor to verify that the fastening patterns meet manufacturer's requirements for issuance of a warranty (as applicable). • All work shall be in compliance with the local building code product control notice of acceptance and manufacturer specifications and Florida Building Code 2017 Edition. • Wnd load calculations based on ASCE-7, 2017 FBC, and information provided by client. Client is responsible for verifying existing/proposed conditions/decks as it pertains to the above provided product :}ppr&mlw,,,, • All work shall be iengmeer (or authorized representative) or a building department inspe, vi specifications. Sincerely, = •' No. 48202 Mark A. Mesiano, PX -P ' •,FLnp !QP.•\�tc� Florida Engineering & $Inc,: • G Florida Reg. No. 48202 ;.'jONA!_ Certificate of Authorization No.1592� "'