Loading...
HomeMy WebLinkAboutCompaction testHeadquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net DATE TESTED:KSM JOB #:200778-2df/MH/jo PERMIT #:NUC #630 CONTRACTOR:Adams Homes Nuc Model:MC-10R-P JOB LOCATION:5811 Balsam Drive Nuc Serial #:30630 Fort Pierce, Florida ITEM TESTED:Compacted Foundation Fill - 2nd Lift TEST LOCATION OF SAMPLE DEPTH PEN READ DRY DENSITY MAX. DRY PROCTOR VALUE (P.C.F) PERCENT COMPACTION 1. S.W.12" - 24"10 95.1 111.2 85.5% 2. N.W."15 95.2 "85.6% 3. Center "9 90.3 "81.2% 4. S.E."12 93.4 "84.0% 5. N.E."11 92.5 "83.2% 101.1 0.9 Soil Description: Brown Sand with traces of Shell Fragments In Place Moisture: 16.7% Proctor Optimum Moisture: 11.0% Proctor Max. Dry Density: P.C.F. 111.2 @ Test Locations the Density & Penetrometer readings indicate the Degree of Compaction DOESN’T MEET Minimum Required for Unstaked Foundation Respectfully Submitted: Bryan E. Dahlke, P.E. V.P. of Engineering PE # 81439 4/23/2020 Email to: joeandujar@yahoo.com; rjohnson@adamshomes.com FAILED Compaction test has FAILED.It is the responsibility of the contractor to evaluate the current condition of the tested area and take necessary actions to compact the tested area further and contact KSM for a follow up compaction test. Proudly Serving Florida since 1990 SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 6938 April 22, 2020 108.0 109.0 110.0 111.0 112.0 113.0 8 9 10 11 12 13 14 W E I G H T P . C . F . D R Y Moisture -% of Dry Weight