HomeMy WebLinkAboutaquacal HP permit markup spesA quality heat pump designed to t any budget 13 9 8 _ 2 _ 1 5 _ v 8 Rated in accordance with ARI standard 1160 water temp/ambient air/relative humidity Specications subject to change BTUs 80/80/80 80/80/63 80/50/63 Coecient of Performance 80/80/80 80/80/63 80/50/63 Refrigerant Heat Exchanger Electrical kW Input Voltage/Hz/Phase Minimum Circuit Ampacity Maximum Fuse Size Water Flow Minimum/Maximum (gpm) Physical Weight (lbs) Length x Width x Height (in) Shipping Weight (lbs) Length x Width x Height (in) Decibels (dB) T55 51,000 47,500 30,000 5.6 5.5 4.0 R410A Tube in Tube 2.7 208-230/60/1 19.4 30 20/45 180 36" x 25" x 28” 220 38” x 26” x 33” 65 T75 72,000 67,000 46,000 5.4 5.3 4.0 R410A Tube in Tube 3.9 208-230/60/1 26.8 45 20/45 200 36" x 25" x 32" 240 38” x 26” x 33” 65 T115 112,000 106,000 74,000 5.6 5.4 4.0 R410A ThermoLink 5.9 208-230/60/1 35.4 60 30/70 259 38" x 29" x 40" 309 40” x 30” x 45” 65 T90 96,000 90,000 65,000 6.0 5.8 4.2 R410A ThermoLink 4.7 208-230/60/1 40.0 60 30/70 255 38" x 29" x 40" 305 40” x 30” x 45” 65 T135 132,000 125,000 84,000 5.7 5.6 4.0 R410A ThermoLink 6.8 208-230/60/1 43.3 60 30/70 287 38" x 29" x 44” 337 40” x 30” x 49” 65 • Microprocessor controlled automatic defrost allows operation down to the mid to lower 40s • High performance titanium heat exchanger (Patented ThermoLink heat exchanger in T90, T115 & T135 models) • Optimum heat output in small footprint • Large surface and corrosion resistant evaporator • Vinyl coated fan grill 2737 24th Street North • St. Petersburg, FL 33713 • 727.823.5642 • aquacal.com Producing quality heat pumps since 1981 A Heater Bypass Kit is required when ow rates exceed the maximum