HomeMy WebLinkAboutREVISION, ENERGY CALCS i
OFFICE USE ONLY:
DATE FILED: b- L) PERMIT,# 1908-0355
REVISION FEE: .D RECEIPT#
PLANNING&DEVELOPMENT SERVICES
BUILDING&CODE REGULATION DIVISION
2300 VIRGIIVIA AVE
___—___ -------------____-. FORT PIERCE,FL 349
(772),462-1553 FAN(79 )_Q
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
1. LOCATION/SF,SON I EREY
ADDRESS: lyl
2. DETAILED DESCRIPTION OF PROJECT
REVISIONS:
REVISED ENERGY CALCS TO SHOW 50 GALLON HOT WATER HEATER
3. CONTRACTOR INFORMATION:
STATE of FL REG./CERT.#: ST.LUCIE COUNTY CERT.#: .8898
BUSINESS NAME: L.ildingorporation
Ew
ADDRESS: N 800b South U wy. ui e
CITY: Fort St. Lucie STATE: ZIP:
PHONE(DAYTIME): - FAX: 772) 878-7 56
4. OWNER/BUILDER INFORMATION:
NAME: Wynne Building Corporation
ADDRESS: 8000 SouthHwy. I Suite 402
CITY: STATE: FL ZIP: 34952
PHONE: (772) 878-5513 FAX: (772) 878-7656
5. ARCHITECT/ENGINEER INFORMATION:
NAME: BRADEN&BRADEN
ADDRESS:- 417 COCON UTAVE.
CITY: STUART STATE: FL ZIP: 34996
PHONE(DAYTIME): (772) 287-8258 FAX:
i .
Revised 07/22/2014
OPeontract®r
Copy
REVISION
_ iT--
CIA
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE.THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR. j
Street: . \JJ _4 \ Permit Office: ST.LUCIE COUNTY
City,State,Zip: FT.PIERCE,FL, Permit Number:
Owner: WY NNE BUILDING CROP Jurisdiction: ST.LUCIE COUNTY
Design-Location: FL,Fort Pierce County: St.Lucie(Florida Climate Zone 2}
1. New construction or existing New(From Plans)- 9. Wall Types(1442.0 sgft.) Insulation Area i
2. Single family or multiple familySingle-family a.Concrete Block-Int insul,Exterior R=4.1' 1250.00 ft2,
b. Frame-Wood,Adjacent -R=11.0 192.00 ft
3:.Number of units,if multiple family 1 c.N/A R= ftz
4. Number of Bedrooms 2 d.N/A R= ftz .
10.Ceiling Types (1476.0 sgft.) insulation Area
5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1446.00 ft?
6. Conditioned floor area above grade(ftz) 1446 b.knee Wall(Vented) R=19.0 30.00 ftz
Conditioned floor area below grade(ftz) 0 c.N/A R= ft?
11.Ducts R ft'
7. Windows(141.3 sgft.) Description Area a.Sup:Attic,Ret:Attic,AH:Attic 6 175
a. U-Factor:' Sgl,U=1,.04 101.25 ftz
SHGC: SHGC=0.29
b. t1-Factor: Sgl,U=1.11 40:00 ftz 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.27 a.Central Unit 34.8 SEER:15.00
C, U-Factor:' N/A ftz.
SHGC: 13.Heating systems kBtu/hr Efficiency
d. U-Factor. NIA ftz a.Electric Heat Pump 34.8 HSPF:8.50
SHGC:
.Area Weighted Average Overhang Depth: 3.832 ft.
Area Weighted Average SHGC: 0.284 14.Hot water systems
8. F1oar Types (1445.5 sqft.) Insulation Area a.Electric Cap:50 gallons
EF:0.970
a.Slab-On-Grade Edge Insulation R=0.0 1445:50 ftz. b. Conservation features
b.N/A R= ftz None
C.N/A R= ftz 15.Credits Pstat
Glass/Floor Area: 0.098 Total Proposed Modified Loads: 47.47 PASS
Total Baseline Loads: 48.09
I hereby certify that the plans and specifications covered by Review of the plans and
this calculation are in compliance with the Florida Energy specifications covered by this
Code. calculation indicates complianceij„r
with the Florida Energy Code.
PREPARED BY; Before construction is completed
DATE. _A129-20 this building will be inspected-for
compliance with'Section 553.908
I herebycerti that this building,as designed,is in compliance Florida Statutes.
00,
fY 9. �
with the Florida Energy Coder : `
OWNER/ Ti BUILDING OFFICIAL:
DATE: .
- compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1. ��
-Compliance requires an.AiFBarrier.and Jnsulation Inspection Checltiist in accordance with R402.4.1.1 and this project requires an
envelope leakage test repgd with envelope leakage no prpater than 7.0o ACH50(R402.4.1.2):
kfv
REV
ctor
ICODE
LU 4 .. Ply
4/21/2020 10:27 AM EnergyGauge@ t 11:02 JRL-v.1)-FlaRes201] J liant Software Page'1 of 5
i
FORM R405=2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
i
-1,
Title: WYNNE THE GRAND CARL Bedrooms: 2 Address Type: Street Address
Building Type: User Conditioned Area: 1446 Lot#
Owner Name: WYNNE BUILDING CROP Total Stories: 1 Block/Subdivision: I
#of Units. 1 Worst.Case: Yes PlatBook:
Builder Name: WYNNE BUILDING COPR. Rotate Angle:. 180 Street:
Permit Office: ST.LUCIE COUNTY Cross Ventilation: . No County ..St.Lucie
Jurisdiction: ST.LUCIE COUNTY Whole House Fan: No City,State,Zip: FT.PIERCE, ;I
Family Type: Single-family- FL,
New/Existing: New(From Plans)
Comment:
li
CLIMATE j
,i
Design Temp Int Design Temp Heating Design Dail Tem
,/ 9 9 Y P
V Design Location TMY Site 97.5% 2.5% Winter /Summer Degree Days Moisture Range
FL,Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 'l Low
i'
BLOCKS
Number Name Area Volume
1 Entire.House 1446 11568
SPACES.
Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled i;:Heated
u
1 BEDROOM 301 2408 No 0 1 1 Yes. Yes Yes
2` WIC 63 504• No 0 1 No Yes ;:Yes
3 M.BATH 56 448 No 0 1 Yes Yes I Yes
I
4 KITCHEN 192 1536 Yes 0 1 No Yes Yes
5 BATH 45 360 No 0 1 Yes Yes II.Yes .
6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes !I Yes
I'
7 ENTRY 55 440 No 0 1 Yes _ Yes Yes
8 LAUNDRY 42 336 No 0 1 Yes Yes i, Yes
9 GREAT/DINING 488 3904 No 0 1.. Yes Yes Yes
FLOORS j
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio BEDROOM 52 ft 0 301 ft2 ____ 0 1. it 0
2 Slab-On-Grade Edge Insulatio WIC 1 ft 0 63 ft2 __-_ 0 1 0
3 Slab-On-Grade Edge Insulatio M:BATH 8 ft 0 56 ft2 ____ 0 1 1,i 0
i
4 Slab-On-Grade Edge Insulatio KITCHEN 1 ft 0 192 ft2 _--_ 0 1 ls 0
5 Slab-On=Grade.Edge Insulatio BATH 5 ft 045 ft2 _ 0 1 0
6 Slab-On-Grade Edge Insulatio BEDROOM 2' 32.2 ft 0 203.5 ft2 .0 1 0
7-Slab-On-Grade Edge Insulatio ENTRY 7 ft 0 55 ft2 ____ 0 1 0
I
ii
.4/21/2020 10:27 AM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 2 of 5
i
Fi
I I
I
FORM R405-2017 INPUT SUMMARY.CHECKLIST REPORT
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
8 Slab-On-Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft2 -__- 0 1 0
9.SIab-On-Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft2 0 1 0
ROOF
/ Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch
V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg)
1 Gable or Shed Metal 1524 ft2 240 ft2 Light N 0.6 No 0.9 No 01 18.4
ii
ATTIC
V # Type- Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 150 1446 ft2 N N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
" 1 Under Attic(Vented) BEDROOM 30 Blown 301 ft2 0.1 Wood
2 Under Attic(Vented) WIC 30 Blown 63 ft2 0.1 Wood
3 Under Attic(Vented) M.BATH 30 Blown 56 ft2 0.1 Wood
4 Under Attic(Vented) KITCHEN 30 Blown 192 ft2 0.1 Wood
5 Under Attic(Vented) BATH 30 Blown 45 ft2 0.1 Wood ;I
6 Under Attic(Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood
7 Under Attic(Vented) ENTRY 30 Blown 55 ft2 0.1 Wood
8 Under Attic(Vented) LAUNDRY 30 Blown .42 ft2 0.1 Wood
9 Under Attic(Vented) GREAT/DINING 30 Blown 488 ft2' 0.1 Wood
ii
10 Knee Wall(Vented) GREAT/DINING 19 Blown 30 ft2 0.11 Wood
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
_
10 Ft In Area R-Mqhle Eraction Absori o
1 NE=>SW Exterior Concrete Block-Int InsuBEDR00M 4.1 10 0 8 0 80.0 ft2 0 0 0.4 II 0
_2 SW=>NE Exterior Concrete Block-Int InsdBEDROOM 4.1 28 0 8 0 224.0 ft2 0 0 0.4 0
3 NW=>SE Exterior Concrete Block-Int InsuBEDROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.4 0
4 SW=>NE Exterior Concrete Block-Int Insul M.BATH 4.1 8 0 8 0 64.0 ft2. 0 0 0.4 0 .
5, NE=>SW Exterior Concrete Block-Int Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.4 0
6 NE=>SW Exterior Concrete Block-Int InsBEDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.4 0
7 SE=>NW Exterior Concrete Block-Int InsSEDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0
8 S=>N Exterior Concrete Block-Int InsBEDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.4 0
9 SW=>NE Exterior Concrete Block-Int InsENEDROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 0.4 0
10 SE=>NW Exterior Concrete Block-Int Insul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0
11 SW=>NE Exterior Concrete Block-Int Insul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0 0.4 0
12 SW=>NE Exterior Concrete Block-Int InsuLAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0
_13 NE=>SW Exterior Concrete Block-Int Inst GREAT/DINI 4.1 26 0 8 0 208.0.ft2 0 0 0.4 0
14 NW=>SE Exterior Concrete Block_-Int InstOREAT/DINI 4.1 20 0 8 0 160.0 ft2 0 0 .0.4 0
4/21/2020 10:27 AM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 3 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
VA ()Mf Th Wall lype Adjacent Cavity Width Height Sheathing Framing Solar '' Below
Space
21
15 N=>S Garage Frame-Wood KITCHEN 11 24 8 192.0 ft2. 0.23 0.4 1 0
DOORS
# Omt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ft2
WINDOWS
Orientation shown is the entered orientation.=> chan ed to Worst Case..
/ Wall Overhang
# Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening
1 NW=>SE 3 Metal Low-E Single Yes 1.04 0.29 Y 32.9 ft2 1 ft 0 in 1 ft 5 in Drapes/blinds Exterior 5
2 SW=>NE 4 Metal. Low-E Single Yes 1.04 0.29 Y 6.9 ft2 1 ft 0 in 1 ft 5 in None None
3 SE=>NW 7 Metal Low-E Single Yes 1.04 0.29 Y 24.0 ft2 6 ft 0 in 1 ft 5 in None None
4 NE=>SW13 Metal Low-E Single Yes 1.04 0.29 Y 37.5 ft2 1 ft 0 in 1 ft 5 in None None
5 NW=>SE 14 Metal.. Low-E Single Yes 1.11 0.27 Y 40.0 ft2 8 ft 0 in 1 ft 5 in Drapes/blinds Exterior 5
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wali Height Exposed Wall Insulation
1 315ft2 315 ft2 24 ft 8ft 11
i
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000356 1349.6 74.09 139.34 .1233 7
HEATING SYSTEM
# System Type Subtype Speed Efficiency Capacity Block Ducts
1 Electric Heat Pump/ Split Singl HSPF:8.5 34.8 kBtu/hr 1 ;jsys#1
COOLING SYSTEM
# System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ Split Singl SEER:15 34.8 kBtu/hr ch 0.8 1 sy8#1
HOT:WATER SYSTEM
# System Type SubType Location ' EF Cap Use SetPnt Conservation.
1 Electric None Garage 0.97 50 gal 60.9 gal 120 deg' None
4/21/202010:27 AM EnergyGauge®.USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 4 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
SOLAR HOT WATER SYSTEM f
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area. Volume FEF
None None ft2
DUCTS
f --Supply— --Return.-- Air CFM 25 CFM25 HVAC#
`J # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 175 ft2 Attic 65 ft2 Default Leakage Attic (Default) (Default)
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
Cooling [[ ]]Jan [[�]Feb [ Mar A r [ 7 May. [X]Jun (X]Jul (X]Aug ]Se [ Oct C�.Nov f XJ Dec
j
He [)C]Jan t 1 Feb [�Mar. [ ]Ar. [ )May t I.Jun t.I Jut [ I Aug 3 Sep 17 Oct Nov
Nov l 1 Dec
� Ventin [[ ]]Jan [[[ 111 Feb [X]Mar [X]Apr: [ ]May ( ]Jun [ 1 Jul [ ]Aug Se !Xl Oct .Nov Dec
Thermostat'Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM' 78 78 78 78 78 78 78 78 80 80 80 ,; 80
PM 80 80 78 78 78 78 78 78 78 78 78 .78
Cooling(WEH) AM 78 78 78 78 78 78 78' 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
! Heating(WD) PM 68 68 68 68 68 68 68 68 68 68 66 i 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 1 '68
` PM 68 68 68 68 68 68 68 68 68 68 66, 66
MASS. '{
Mass Type Area Thickness Fumifure Fraction Space
Default(8 lbs/sq.ft. 0 ft2 0 ft 0.3 MASTER BEDROO
Default(8 lbs/sq.ft. ft2 ft 0.3 WIC
Default(8 lbs/sq.ft. ftz ft 0.3 MASTER BATH
Default(8 lbs/sq.ft. ft2 ft 0.3 M.BATH
Default(8 lbs/sq.ft. ft2 ft 0.3 LAUDRY
Default(8 lbsJsq.ft. ft2 ft 0.3 BEDROOM 2
Default(8.Ibs/sq.ft. ft2 ft" 0,3 DINING/GREAT R
Default(8 lbs/sq.ft. ft2 ft 0.3 KITCHEN
Default(8 lbs/sq.ft. ft2 ft 0.3 BATH
Default(8lbs/sq.ft. ft2 ft 0.3 HALL
Default(8 lbs/sq.ft. ft2 ft 0.3 FOYER
Default(8 lbs/s .ft. ft2 ft . 0.3 BEDROOM:3
4/21/2020 10:27 AM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 5 of 5
' 2017 -AIR.BARRIER AND INSULATION-INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR.
Street: Permit Office: ST.LUCIE COUNTY
City,State,Zip: FT.PIERCE,FL, Permit Number:
Owner: WYNNE BUILDING CROP Jurisdiction: ST.LUCiE COUNTY
Design Location: FL,Fort Pierce
COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA
General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall
The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material.
requirements Breaks or joints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit
Ceiling/attic the insulation and any gaps-in the air.barrier shall be sealed. shall be aligned with the air barrier.
Access openings,drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls
The junction,of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity
sealed. with a material having a thermal resistance of R-3
Knee walls shall be sealed. per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows,skylights The space between window/door jambs and framing,and
and doors skylights and framing shall be sealed.
Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated.
Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed,to
(including Insulation. maintain permanent contact with the underside of
above-garage subfloor decking,or floor framing cavity insulation
and cantilevered shall be permitted to be in contact with the top side
floors) of sheathing,or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation
a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace
Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to
exterior or unconditioned s ace shalt be sealed.
'Batts in narrow cavities shall be cut to fit,or narrow
Narrow cavities cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spac as.
Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building
shall be sealed to the drywall. thermal envelope shall be air tight and IC rated.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls,or insulation that on
installation readily conforms to available space shall
Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall
on exterior wall tubs shall separate them from the showers and tubs. be insulated.
Electrical/phone box or The air barrier shall be installed behind electrical or communication
exterior wails boxes or air-sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub-floor or drywall.
Concealed When required to be sealed,concealed fire sprinklers shall only be
sprinklers sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
.a.In addition,inspection of log walls shall be in accordance with the provisions of ICC-400.
4/21/2020 10:32 AM EnergyGaugeO USA 6.0.02(Rev.1)-F1aRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 1
4
2017-EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX*= 99
The lower the-Energy Performance Index,the more efficient the home.
1.New home or,addition 1. New(From Plans) 12. Ducts,location&insulation level
a)Supply ducts R 6.0 I
2. Single-family or multiple-family 2. Single-family ',b)Return ducts R 6.0
c)AHU location Attic
3.No.of units(if multiple-family) 3. 1
4. Number of bedrooms 4. 2 13. Cooling system: Capacity 34.8
a)Split system SEER 15.0
5. Is this a worst case?(yes/no) 5. Yes b)Single-,package SEER
c)Ground/water source SEER/COP
6. Conditioned floor area(sq.ft.) 6. 1446 d)Room unit/PTAC EER
e)Other
7.Windows,type and area
a)U-factor:(weighted average) 7a. 1.060
b)Solar Heat Gain Coefficient(SHGC) 7b. 0.284 14. Heating system: Capacity 34.8 {
c)Area 7c. 141.3 a)Split system heat pump HSPF. 8.5 .
b)Single package heat pump_HSPF
8.Skylights c)Electric resistance COP
a)U-factor:(weighted average) 8a. NA d)Gas furnace,natural gas AFUE
b)Solar Heat Gain Coefficient(SHGC) 8b. NA e)Gas furnace, LPG AFUE
D Other
9. Floor type,insulation level:
a)Slab-on-grade(R-value) 9a. 0.0
b)Wood, raised (R-value) 9b. 15.Water heating system
c)Concrete,raised(R=value) 9c. a)Electric resistance EF 0.97
b)Gas fired,natural gas EF
10.Wall type and insulation: c)Gas fired,LPG EF
A.Exterior: d)Solar system with tank EF
1.Wood frame(Insulation R-value) 10A1. e)Dedicated heat pump with tank EF
2.Masonry(insulation R-value) 10A2. 4.1 f)Heat recovery unit HeatRec%
B.Adjacent: g)Other
1.Wood frame(Insulation R-value) 10B1. 11.0
2.Masonry(Insulation R-value) 10132.
16. HVAC credits claimed(Performance Method)
11.Ceiling type and insulation level a)Ceiling fans
a)Under attic 11a. 30.0 b)Cross ventilation No
b)Single assembly 11b. c)Whole house fan No
c)Knee walls/skylight walls 11c. 19.0 d)Multizone cooling credit
d)Radiant barrier installed 11d. No e)Multizone heating credit
f)Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code,Energy Conservation,if not DEFAULT.,
I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy
saving features which will be installed(or exceeded).in this home before final inspection.Otherwise,a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: �/ �" � Date:
Address of New Home: \ �' �+\ '� City/FL Zip: FT PIERCE FL
4/21/202010:32:17 AM EnergyGaugeO USA 6:0.04(Rev.1)-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1