Loading...
HomeMy WebLinkAboutPile Installation InspectionA%CA A KELLER, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, INC. MARTIN (/72) 337-7755 P.O. BOX 78-1377, SEBASTIAN, FL 32978-1377 SEBASTIAN (772) 589-0712 PALM BEACH (561) 845-7445 www.ksmengineering.net MELBOURNE (321) 768-8488 FAX (561) 845-8876 E-Mail: KSM@KSMENGINEERING.NET ST. LUCIE (772) 229-9093 C.A.: 5693 FAX (772) 589-6469 September 9, 2019 Joseph Miranda 9224 Bay Drive Surfside, FL 33154 Re: Re: Pile Installation Inspection 7916 S. Ocean Drive Jensen Beach, Florida KSM Project #: 193472-pile Dear Mr. Miranda: RI CEIVED f` .z02019 ST. Lucie County, Perm - As requested, we were present during the installation of the ninety-eight (98) auger -cast -piles for the above referenced site. Pile layout by others. The pile installation inspection was generally performed in accordance to the 'Inspector Guide to the Auger Cast -In -Place. Piles", published by the Auger Cast -In -Place Pile Committee of The Deep Foundation Institute. Based on this inspection, it is our professional opinion, that the piles constructed for the referenced project were. installed as specified on the construction drawings. The pile documentation: and Location Plan are attached. We are pleased to be of assistance to -you on this phase of your project. if you have any questions;. please feel free to contact the office. J ie E. Keller P- Emalf:4b: )miranda@jfminc.biz: FILE Copy Ronald G. Keller, RE.: 37293 / SI Lic. No.: 860 / Julie E. Keller, P.E.: 68366 Tl G! 1 t JL%17jMb KELLER, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, INC. MARTIN (772) 337-7766 P.O. BOX 78-1377, SEBASTIAN, FL 32978-1377 SEBASTIAN (772) 589-0712 PALM BEACH (561) 845-7445 www.ksmengineering.net MELBOURNE (321) 768-8488 FAX (561) 845-8876 E-Mail: KSM@KSMENGINEERING.NET ST. LUCIE (772) 229-9093 C.A.: 5693 FAX (772) 589-6469 Pile Installation Inspection 7916 S. Ocean Drive Jensen Beach, Florida KSM Project #: 193472 Date Installed: August 26 and 27, 2019 Pile Location (See Location Plan Pile Diameter Pile Length Pile Reinforcement Pump Strokes Truck No. Time Installed August 26, 2019 1 16" 25' (6) #6 Vertical 24' Bars w/ #3 Ties @ 12" c.c. to 20' 16 25316 9:33 2 16 25316 9:44 3 " 16 25316 9:53 4 17 25316 10:00 5 17 25316 10:07 6 16 25316/71287 10:13 7 16 25316/71287 10:21 8 17 71287 10:29 9 17 71287 10:36 10 18 71287 10:44 11 18 71287 10:56 12 18 71287/67685 11:05 13 17 67685 11:11 14 16 67685 11:18 15 19 67685 11:28 16 19 67685 11:36 17 18 67685/64624 11:43 18 18 64624 11:50 19 18 64624 12:02 20 17 64624 12:09 21 19 64624 12:19 22 18 64624 12:32 23 19 71287 12:45 24 17 71287 1:02 25 18 71287 1:16 26 18 71287 1:28 27 18 71287 1:42 28 " " 17 71287/67685 1:51 29 17 67685 2:00 30 18 67685 2:08 31 17 67685 2:16 32 " 17 67685 2:24 Ronald G. Keller, P.E.: 37293 / SI Lic. No.: 860 / Julie E. Keller, P.E.: 68366 Yam' o'► t AIL&JAW KELLER, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, INC. MARTIN (772) 337-7755 P.O. BOX 78-1377 SEBASTIAN, FL 32978-1377 SEBASTIAN (772) 589-0712 PALM BEACH (561) 845-7445 www.ksmengineering.net MELBOURNE (321) 768-8488 FAX (561) 845-8876 E-Mail: KSM@KSMENGINEERING.NET ST. LUCIE (772) 229-9093 C.A.: 5693 FAX (772) 589-6469 Pile Installation Inspection 7916 S. Ocean Drive Jensen Beach, Florida KSM Project #: 193472 Date Installed: August 26 and 27, 2019 Pile Location (See Location Plan Pile Diameter Pile Length Pile Reinforcement Pump Strokes Truck No. Time Installed August 26, 2019 33 16" 25' (6) #6 Vertical 24' Bars w/ #3 Ties @ 12" o.c. to 20' 20 67685/64624 2:32 34 19 64624 2:44 35 18 64624 2:54 36 16 64624 3:04 37 17 64624 3:10 38 18 64624 3:20 39 18 71287 3:31 40 17 71287 3:40 41 19 71287 3:49 42 I 17 71287 3:57 43 " 17 71287 4:05 44 20 71287 4:13 45 17 67685 4:24 46 18 67685 4:31 47 j 17 67685 4:38 48 19 67685 4:47 49 17 67685 4:54 50 20 67685 5:05 August 27, 2019 51 16" 25' (6) #6 Vertical 24' Bars w/ #3 Ties @ 12" o.c. to 20' 17 25756 8:40 52 ° 17 25756 8:50 53 " 21 25756 9:08 54 " M 19 25756 9:14 55 21 1 25756 9:29 56. 18 64624 9:37 57 I 18 64624 9:46 58 22 64624 9:55 59. I 19 64624 10:04 60 " 18 64624. 10:13 61 " 23 64624 10:48 , 62 --' 22 64623 10:58 Ronald G. Keller, P.E.: 37293 / SI Lic. No.: 860 / Julie E. Keller, P.E.: 68366 Tip OIL t "ClIlm KELLER, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, INC. MARTIN V72) 337-7755 P.O. BOX 78-1377, SEBASTIAN, FL 32978-1377 SEBASTIAN (772) 589-0712 PALM BEACH (561) 845-7445 www.ksmengineering.net MELBOURNE (321) 768-8488. FAX (561) 845-8876 _ E-Mail: KSM@KSMENGINEERING.NET ST. LUCIE (772) 229-9093 C.A.: 5693 FAX (772) 589-6469 Pile Installation Inspection 7916 S. Ocean Drive Jensen Beach, Florida KSM Project #: 193472 Date Installed: August 26 and 27, 2019 Pile Location . (See Location 1 Plan Pile Diameter Pile Length Pile Reinforcement Pump Strokes Truck No. Time Installed Au usf 27, 2019 63 I' j -16' 25'. (6) #6 Vertical 24' Bars. w/#3 Ties @ 12" e.c. to 20' 18. 64623 11:12- 64 18 64623 11:22 I 65 20 64623 11:34 66 18 64623 12:35 67 19 64624 1 12:47 68 _ " 18 64624 12:53 I 69 " " 18 i 64624 1:04 `70 _ _ _" 18 64624 1:13 1 .71 ....G 21 64624 1:30 j 72 — -- - . 8 26433 1:41 �- 73 j_ 19 1 26433 1:53 j 74 " 20: 26433 1:59 75 l " " 20` 26433 2:08 76 20 26433 2:15. 77 19 26433 2:30 78 " 21 25756 2:42 79 22 25756 2:49 80 " " 21 25756,4 2:57 81 19 25756 3:08 82 21 25756 3:27 -- 83 - . " " 18 66455 3:37 84 " 20 66455 3:43 85 " " 20 66455 3:52 - 86 19 66455 4:07 87 " 18 66455 4:18 88 19 66455 4:28 89 21 26433 4:37 90 " " 20 26433, 4:46 - 91. I9 26433 4:55 1 92 1 93 " -- - "" 18-- 18 26433. 26433 5:06 5:18 94 21 25756 5:26 I Ronald G. Keller, P.E.: 37293 / SI Lic. No.: 860 / Julie E. Keller, P.E.: 68366 �17M KELLER, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, INC. MARTIN (772) 337-7755 P.O. BOX 78-1377, SEBASTIAN FL 32978-1377 SEBASTIAN (772) 589-0712 PALM BEACH (561) 845-7445 www.ksmengineering.net MELBOURNE (321) 76868488 FAX (561) 845-8876 E-Mail: KSM@KSMENGINEERING.NET ST. LUCIE (772) 229-9093 C.A.: 5693 FAX (772) 589-6469 Pile Installation Inspection 7916 S. Ocean Drive Jensen Beach, Florida KSM Project #: 193472 Date Installed: August 26 and 27, 2019 Pile Pile Pile Pile Pump Truck No. Time Location Diameter Length Reinforcement Strokes Installed (See Location Plan August 27, 2019 95 16" 25' (6) #6 Vertical 24' Bars 17 25756 5:33 w/ #3 Ties @ 12" o.c. to 20' 96 21 25756 5:42 97 19 25756 5:53 98 20 25756 6:05 Notes: 1. Grout Strength 28 Days Compressive Strength — 5,000 PSI 2. 1 Pump Stroke = 2.35 cu. ft. of Grout Ronald G. Keller, P.E.: 37293 / SI Lic. No.: 860 / Julie E. Keller, P.E.: 68366 .r .r r �{. r .r .r "r ... •.• ^• `• ' 98 1 8 43 7 4S 9 46 10 48 11 49 12 50 1 J 55 18 17 15 38 14 — i Ism m 94. m m` I L� I I I 1 61 I I I fi0 I I SBm _ 51 _ r . 911911 ss I I ° 19 41 r s I e 29� i I a I4a 84 _ _ at 59 1 ®— 57 L57 47 82 - i�1 I L 45 t----- r ------ 13 • y 88 85 I 1 rztm .. h.. I 93 34 5 9 I 78 — 73 85 20 97 9fi e� a "I-T 37 35 __. 38 y-- e i 81 --79 75 L-� sa 92 ..�95 — 80 ; mi®s —r 191 m I — 88 ± L J 77 t i i I I 74 72 , 32 9 -- 90 33 89 m 30 m 87 29 m n ® 28 7fi 27 i C 25 PILING AND GRADE BEAM PLAN SCALE 11V =1'-0" O LOCATION OF AUGER PILES - RESIDENCE PROJECT. Miranda Residence, 7916 S. Ocean Drive, Jensen Beach, Florida SHEET 1 OF 2 DRAIVNBY: J.L. PERMIT#: PROJECT #: 793472-1 IJAW AND TESTIN DESIGNED BY.-J.K. SCALE: NONE 010 Ll ------------ 22 23 21 7169 a7 -- - ----- 62 , 63 t�J • I: 24 .�-66- 26' 14 O LOCATION OF AUGER PILES - POOL/SPA PROJECT.• Miranda Residence, 7916 S. Ocean Drive, Jensen Beach, Florida SHEET 2 OF 2 DRAWNBY.• J.L. r% IJDESIGNED BY:J.K. PERMIT#: ��j AND TESTIN DATE: °'° NONE PROJECT: 193472-2 SCALE: NONE