HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: MEAD ADDITION Builder Name: Street: 5519 PINE TREE DRIVE Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number. Owner. GERARD MEAD Jurisdiction: Design Location: FL, Fort Pierce County: St Lucie (Florida Climate Zone 2 ) 1. New construction or existing Addition 9. Wall Types(485.3 sgft.) Insulation Area a. Frame - Wood, Exterior R=13.0 485.33 ft' 2. Single family or multiple family Single-family b. WA R= ft2 3. Number of units, if multiple family 1 c. WA R= ft2 4. Number of Bedrooms(Bedrms In Addition) 0(0) d. WA R= ft2 10. Ceiling Types (ente sqR.) Insulation 0 n 5. Is this a worst case? No a. Under Attic (Vented) R=19 396.00Area 6. Conditioned floor area above grade 396 b. WA R= ft2 c. WA R= ft2 Conditioned floor area below grade at0 0 11. Ducts R ft2 7. Windows(15.0 sgft.) Description Area a. Sup: Attic, Rat: Attic, AH: ADDITION 6 79 a. U-Factor. Sgl, U=0.65 15.00 ft2 SHGC: SHGC=0.30 12. Cooling systems kBtu/hr Efficiency b. U-Factor. WA ft2 a. Central Unit 18.8 SEER:16.00 SHGC: c. U-Factor. N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor. WA ft2 a. Electric Strip Heat 17.0 COP:1.00 SHGC: Area Weighted Average Overhang, Depth: 2.000 R Area Weighted Average SHGC: 0.300 14. Hot water systems- None required a, Cap: N/A 8. Floor Types (396.0 sgfL) Insulation Area EF: 0.000 a. Slab -On -Grade Edge Insulation R=0.0 396.00 ft2 b. Conservation features b. N/A R= ft2 c. N/A R= ft2 15. Credits None Total Proposed Modified Loads: 11.80 PASS Glass/Floor Area: 0.038 Total Baseline Loads: 12.23 I hereby certify that the plans and specifications covered by Review of the plans and O� Clifi STgpB this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREP D Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 ° e I hereby certify that this building, as designed, is in compliance Florida Statutes. 5S COD with the Florida Energ Code. WE OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 7/23/2019 3:56 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4 r norm Reny-,)n17 IMPI IT All IMMARY CHFCKI IST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/F)dsbng: Comment MEAD ADDITION User GERARD MEAD 1 ST. LUCIE COUNTY Single-family Addition Bedrooms: 0 Conditioned Area: 396 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: Whole House Fan: Address Type: Street Address Lot # Block/Subdivision: PlatBook: Street: 5519 PINE TREE DRIV County: St. Lucie City, State, Zip: FT. PIERCE, FL, CLIMATE Design Location ' Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blockl 396 3168 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 ADDITION 396 3168 No 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio ADDITION 78 ft -0 396 ft' — 0 0 1 ROOF # Type Roof Gable Roof Materials Area Area Color Red Bar Solar SA Emitt Emitt Deck Pitch Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 429 ft' 0 ft' Medium N 0.6 No 0.9 No 0 22.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 396 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) ADDITION 19 Blown 396 ft' 0.11 Wood 7/23/2019 3:56 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _ 1 W _ 2 N 3 S Exterior Frame - Wood Exterior Frame - Wood Exterior Frame - Wood ADDITION 13 16 8 8 133.3 ft' 0 0.25 0.6 ADDITION 13 22 8 176.0 ft' 0 0.25 0.6 ADDITION 13 22 8 176.0 ft' 0 0.25 0.6 0 0 0 WINDOWS Orientation shown is the entered, Proposed orientation. # Wall Omt ID Frame Panes Overhang NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S 3 Metal Low-E Single Yes 0.65 0.3 N 15.0 ft' 2 ft 0 in 1 ft 4 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 369.6 20.29 38.16 .1233 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/Supplemen None COPA 17 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/Supplemental for None SEER: 16 18.8 kBtu/hr 564 cfm 0.8 1 sys#1 SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume ' FEF fF DUCTS # — Supply — Location R-Value Area — Return — Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT ON RLF HVAC # Heat Cool 1 Attic 6 79 it' Attic 20 ft' Default Leakage ADDITION (Default) (Default) 1 1 7/23/2019 3:56 PM EnergyGauge® USA 6.0.02 (Rev. 1) FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 rnona Penr_inI7 IMPI IT RI IMMARV CFIFCKLIST REPORT TEMPERATURES Programabl[e T]hermosta[[t]]N C[eilling Fans: Heating [X] Jan [X] Feb Mar [ ] [ ] [ 1 [X] ] Jun [X] ] Jul [X] [ ] Aug [X] ] Sep ] LJ Oct Nov Dec Venting ll 11 Jan [[ 1) Feb X Mar [X) Apr [ l) May E 1 Jun E )Jul [)Aug E )Sep Lxl Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 .78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 Healing (WD) AM 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 Heating OJVEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft' 0 ft 0.3 ADDITION 7/23/2019 3:56 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 2017 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: MEAD ADDITION Builder Name: Street 5519 PINE TREE DRIVE Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number. Owner. GERARD MEAD Jurisdiction: W x Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) - of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floorinsulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on Narrow cavities installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light factures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind ninino and wirinn Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication . exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire snrinkler cover rilateig and walls or cemlinog a. In addition, inspection of log walls shall be in accordance with the provisions or IUU-4UU. 7/23/2019 3:56 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. Addition 12. Ducts, location & insulation level a) Supply duds R 6.0 2. Single-family or multiple -family 2. Sinole-family b) Return ducts R 6.0 c) AHU location ADDITION 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 0 13. Cooling system: Capacity 18.8 a) Split system SEER 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/Water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 396 d) Room unit/PTAC EER e) Other 16.0 7. Windows, type and area a) U-factor.(weighted average) 7a. 0.650 b) Solar Neat Gain Coefficient (SHGC) 7b. 0.300 c) Area 7c. 15.0 8. Skylights a) U-factor.(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee wallsiskylight walls d) Radiant barrier installed 10A1. 13.0 10A2. 10131. 1062. 11a. 19.0 11b. 11c. 11d. No 14. Heating system: Capacity 17.0 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP 1.0 d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE 0 Other 15. Water heating system a) Electric resistance EF b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF_ f) Heat recovery unit HeatReC% g) Other 16. HVAC credits claimed (Performance Method) a) Ceiling fans b) Cross ventilation No c) Whole house fan No d) Multizone cooling credit e) Multizone heating credit f) Programmable thermostat No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder SignaturA Dater ! 7 ZC.) Address of New Home: 5519 PINE TREE DRIVE City/FL Zip: FT. PIERCE. FL 7/23/2019 3:56:16 PM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 wrightsoft' Project Summary Me: Enure House By. QUICK CALCS, INC. 317 ST.. LUCE LANE. FORrPERCE, FL34946 PMM:772d66-6799 E=I:QUICKCALCS@AOL.COM For. GERARDADDITION 5519 PINE TREE DR, FT. PIERCE, FL Notes: Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF OF Outside db 90 75 OF OF Inside db 70 Inside db Design TD 28 OF Design TD 15 OF Daily range Relative humidity M 50 % Moisture difference 61 grllb Heating Summary Sensible Cooling Equipment Load Sizing Structure 11570 Btuh Structure 12022 Btuh Duds 2000 Btuh Duds 2870 Btuh Central vent (0 dm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh (none) Blower 0 Btuh Piping 0 Btuh Equipment load 13570 Btuh Use manufacturer's data n Rate/swingg multiplier 0.95. Infiltration Equipmenisensibleload 14148 Btuh Method Simplified Latent Cooling Equipment Load Sizing . Construction quality Average Structure 1412 Btuh Duds 809 Btuh Central vent (0 dm) 0 Btuh Area.(ff� Heatingg . 704 Coolingg 704 (none) Equipment latent load 7991 Btuh Molume (fta) Airchangges/hour 6336 0.61 6336 0.32 Equipment Total Load (Sen+Lat) 0.70 SHR 16369 1.7 Btuh ton Equiv. AVF (dm) 64 34 Req. total capacity at Heating Equipment Summary Cooling Equipment Summary Make Make Trans Trade Trade TRANE Model Cond 4TTR4018L1 AHRI ref Coil TEM6AOB24H21++TDR AHRI ref 7567539 Efficiency 100 EFF Effictency 13.0 EER 16 SEER Heating input 3.8 kW Sensible cooling 13160 5640. Btuh Btuh Heating output Temperature rise 12812 50 Bhih OF Latent000ling Total cooling 18800 Btuh Actual airflow 233 cfm Actual airflow 627 dm Airflowfactor 0.017 dm/Btuh Airflowfador 0.042 dm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.87 Calculations approved byACCAtD meet all requirements of Manual J 8th Fit. _ -1�1 wrigh�o� 2019.d1-2316:1029 RigtFSutaou,, e W 201919.0.07 RSU03101 Page 1 ACCK _UICMDOa rtsWngtto6HVACWIEAD,GERARDnp CaIc=MI6 Frort Doarfeces E wrightsoft' Right-M Worksheet Date: Entire House Dabs BY• QUICK CALCS, INC. 317 ST.. LUCIE LANE, FORTPIERCE, FL34946 Phore: 772-466-6799 Ema1:QUlCKCALCS@AOL.COM 1 Room reme EnbreHoure b4A9TER WH 2 E>posedwall 120.0 it 44.0 it 3 Room height 9.0 It 9.0 it heaflmol 4 Room dmensl re 1.0 x 256.0 it 5 Roomarea 704.0 tf 256.0 fF Ty Construction U-vdlue Or HTM Area (W) Load Area (IF) Load number (Buff-9 (BWMP) or perimeter (w (Bbdt) or perimeter (fQ (Bb h) Heat Cad Gros NIBS Heat Cod Gros WPIS Heat Cod 6 W 12C-0av 0.091 n 255 1.98 144 144. 367 282 -144 144 367 282 y/ 12C4)SN 0.091 a 265 1.96 396 366 933 716 126 12S 321 247 --G IA -Glom 1270 a 35.56 87.05 30 2 1067 2612 ' D 0 0 0 W 12C-09N 0.091 s 255 1.96 144 144 397 282 0 a 0 0 11 12C-0av 0.091 w 255 1.96 396 339 864 664 126 110 280 215 �G tAclom 1270 w 35.56 88.14 41 2 1451 3596 0 0 0 0 `G 4A5-2ob 0.660 w 15.68 41.45 16 1 251 663 16 1 251 663 C 16B-19ad 0.049 - 1.37 2.45 704 704 966 1725 256 256 351 627 F 22A-b11 0.989 - 27.69 0.00 704 120 3323 0 256 44 1218 0 6 C)AED euwson 926 367 Emelopeloslgain %588 11465 2789 2401 12 a) brblbabon 1902 557 727 204 b) RmmwrNlaffm 0 0 0 0 13 Internal gains Omryanfs@ 230 0 0 0 0 Applianceslbl er 0 0 Subtotal QinWM313) 11570 12022 3516 2605 Lesse)bnW load 0 0 0 0 Les7ansrer 0 0 D 0 Redsbibubon 0 0 0 0 14 Subblfal 11570 12022 3516 2W5 15 Dudloads 17% 24% 2M) 2870 17% 24% W8 622 Total room load 13570 14892 4123 3227 Airrequired (dm) 233 827 71 136 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. _ -1W wri9hLsofY 2019-al-23 16:1029 •--- RigtFSut�ERARDaW Cal9=MJ8 SU08101 Pagel 'tea^...UICIMoamerlsiWri9HsoRl'IVACWCAD,GERARDnp CaIc=MJ6 Fmdpoorfaoes: E IirF wrightsoft• Right-M Worksheet Job: Entire House Dom` sy: QUICK CALCS, INC. 317 ST.. LUCIE LANE, FORTPIERCE, FL34946 Phom:772-466-6799 Emil: 1 Room name WIC WIC2 2 EVO dvell ao It 8.0 It 3 Room height 9.0 it heaYm01 9.0 a heaNmol 4 Room cfine ons 6.0 x 8.0 R 6.0 x 8.0 ft 5 Roan area 48.0 IF 48.0 IF Ty Conttrudion U-value Or HTM Area (T) Load Area (M Load number (Buir-n (BWMF) a perimeter (ff) (Bfuh) a perimeter (ff) (Btrfi) Heat Cool Cross NIPIS Halt Carl Cross NIPIS Heat Cod 6 W 12C-0sv 0.091 n 255 1.96 0 0 0 0 0 0 0 0 Vp/ 12C�v 0.091 a 255 1.96 0 0 0 0 72 72 183 141 I--G 1Aclom 1270 a 35.56 97.06 0 0 0 0 0 0 0 0 W 12C-0sN 0.091 s 265 1,96. 0 0 0 0 0 0 0 0 11 l4J 12C-Ow 0.091 w 255 1.96 72 72 183 141 0 0 0 0 1AcIom 1270 w 35.65 88.14 0 0 0 0 0 0 0 0 ��GG 4A5-20b 0.560 w 15.68 41.45 0 0 0 0 0 0 0 0 C 16B-19ad 0.049 - 1.37 245 48 48 66 118 48 48 66 116 F 22A-V 0.989 - 27.69 0.00 48 8 222 0 48 8 222 0 6 C)AEDowsim 0 0 Frnetope lossfgain 471 258 471 258 12 a) Mallon 132 37 132 37 b) Room %endlaBon 0 0 0 0 13 Intnal gains 00awnls@ 230 0 0 0 0 Appliancesfolher 0 0 Subtotel(lines6lo13) 603 296 603 296 Lessextemallmd 0 0 0 0 Lesstran4er 0 0 0 0 RedatfbiAon 0 0 0 0 14 Sublotal 663 296 603 296 15 DUQleads 17% 24% 104 71 179% 24% 104 71 Total room load 707 366 707 366 hrrequired (dm) 12 15 12 15 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. 2019JW-2316:1029 Rigft-SULOLhimrersa1201919.0.07 RS1A6101 Page 2 �� ...UICIODoa rts\WdgttsoBHVACNAEAD,GERARD.np Caic=MJ8 FrortDcorfaces: E I wrightsof , Right-J@ Worksheet Job: Entire House pate: By. QUICK CALCS, INC. 317 ST. LUCIE LANE, FORTPIERCE, FL34946 P1ure: 772-466-6799 EmaII:QUICKCALCS@AOL.COM 1 Rcom nave MASTER BEDROOM 2 Exposedvdl 60.0 ft 3 Room height 9.0 ft hea d 4 Roomdimenaons 16.0 x 220 ft 5 Rcom 3520 ft' Ty Construmon U-value Or HTM Area (ftF) Load Area Load number (BUVF-*F� or pedmew (11) (evh) or perimeter Heat Cool Gross NBS Heat Cool Gross NIP1S Het Coal 6 W 12C-0ex 0.091 n 255 1.96 '0 0 0 .0 12C-0sv 0.091 a 255 1.96 198 168 428 329 1Aalem 1270 a 35.56 87.06 30 2 1067 2612 W 12C-09v 0.091 s 255, 1.96 144 144 367 282 11 U11 12C-09N 0.091 w 2.55 1.95 198 157 401 308 " I`----GG 1Acl m 1270 w 35.55 88.14 41 2 1451 3596 4A5-2ob 0.560 w 15.68 41.45 0 0 0 0 C 16B-19ad 0.049 - 1.37 245 352 352 483: 862 F 22A-bA 0.989 - 27.69 0.00 352 60 1662 0 6 c)AED murson 560 Envelope losslgain 5858 8548 12 a) In6ltraim 991 279 b) Reomwdatm 0 0 13 Ntemal gains Cmipan5@ 230 0 0 . Applimmslotller 0 Subtotal(Iinm5to 13) 6849 8826 LesseMemal load 0 0 Lesstransfer 0 0 Redistri bution 0 14 J0 Subtotal - 6849 8626 15 DUGloatls 17% 24% 1184 2107 Total:loatl 8032 10933 Airrequired(dm) 138 460 Calculations approved bVACCAto meet all requirements of Manual J 8th Ed. wri9F+_esoR- 2019-Jd-2316:1029 Rigt[Sule®Uriversa1201919.0.07 RSU08101 Page 3 ...UICKUoa rtstWdghWft HVACNEAD,GERARD.np Calc=MJB FmrtDoorfaces E wrightsoft• Duct System Summary Entire House QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE. FL34946 Phone: 772466-6799 ErreiI:QUICKCALCS@AOL.COM For. GERARDADDITION 5519 PINE TREE DR., FT. PIERCE, FL External static pressure Pressure losses Available static pressure Supply/return available pressure Lowestftiction rate Actual airflow Total effective length (TEL) Heating 0.50 in H2O 0.28 in H2O 0.22 in H2O 0.110/0.110 in H2O 0.080 in/100ft 233 dm 88 ft Supply Branch Detail Table Job: Data: By. Cooling 0.50 in H2O 0.28 in H2O 022 in H2O 0.110/0.110 in H2O 0.080 in/100ft 627 ch Design Htg Clg Design Diam H x W Dud Actual Ftg.Egv Name (Btuh) (Cann) (Clm) FIR (in) (in) Mat Ln (ft) Ln (ft) Trunk MASTERSAni C 3227 71 136 0.080 7.0 OxO VIFx 9.0 70.0 MASTERBEDROOM c 5467 69 230 0.080 &0 OxO VIFx 4.1 70.0 MASTERBEDROOWB C 5467 69 230 0.080 &0 OxO VIFx 18.0 70.0 WIC c 366 12 15 0.080 4.0 Ox0 VIFx 3.6 70.0 WIC2 c 366 12 15 0.080 4.0 Ox0 VIFx 3.6 70.0 Return Branch Detail Table Name Grille Size (in) Htg (cfrn) Clg (ch) TEL (it) Design I FIR(fpm) Veloc I Diam (in) H x W (in) Stud/Joist Opening (in) Dud Matl Trunk rb1 Ox0 233 627 0 1 0 0 0 Ox 0 VIFx BdditOc values have been manwfly overldCen wrightsoft'° ,.._,., Riga-Sufe®Unversa1201919.0.07 RSU06101 ' C6, ...UICK\Doamerb\WrightsoftWACWIEAD,GERARDnp Calc=MJ6 Fmri Docrfaces E 2019-JU-2316:1029 Page 1