HomeMy WebLinkAboutShop drawing, 10045613-3-1 St Lucie Fire StationsA C RJ #2 END STILE LOCK QTY = 2 PLCS 1.00" SOLID STEEL SHAFT SUPPORT BRACKET SHAFT COUPLER L.H. WOUND TORSION SPRING STD LIFT CABLE DRUM N ELEVATION VIEW INSIDE LOOKING OUT DRAWN BY: DRAWING NUMBER: DATE:APPROVAL SIGNATURE: SHEET: CUSTOMER: CSR/DC: APPROVAL DATE: JOB: SHOP DRAWING DOOR CONFIGURATION MODEL DESIGN TOP GLAZING FINISHINSUL IMPORTANT: This document must be signed and returned prior to any fabrication. Please reference this drawing number on all correspondence. Thank you! NOTICE: Confidential/Proprietary information of CLOPAY BUILDING PRODUCTS CO. is contained herein and may not be disclosed, used, duplicated, made available, or distributed without its prior consent. Failure to observe this notice may result in liability for any damages and losses resulting therefrom. OVERHEAD CLEARANCEG DIM.DESCRIPTION DIMENSIONS QUANTITY OF SECTIONS HIGH HEADROOM (MIN.) SPRING PAD OFFSET 1 FLOOR TO CEILING (MIN.) JAMB HEIGHT (MIN.) R M L E F J OPENING WIDTH OPENING HEIGHT DOOR WIDTH DOOR HEIGHT B D C A N SHAFT CENTER LINE SPRING PAD OFFSET 2 BACKROOM (MIN.) K QUANTITY OF PANELS WIDE H NOTES: S TRACK BACKROOM WEIGHT (LBS) W8 11'-9" 11'-7" 12'-9" 12'-9" 3 7 1'-10" 14'-7" 13'-4" 14'-8" 14'-7" 5'-3.5" 0'-4.5" 0'-4.5" 16'-9" 13'-11" 0'-7" ACTUAL DOOR HEIGHT IS APPROX. 1" OVER BECAUSE OF JOINTS BETWEEN SECTION PLUS BOTTOM ASTRAGAL 1. ( ) DOOR 2. DOOR TO BE SUPPLIED WITH CYCLE TORSION SPRINGS. 3. DOOR TO BE SUPPLIED WITH REVERSE ANGLE MOUNTED, 2" GALVANIZED STEEL TRACK WITH 15" RADIUS STANDARD LIFT. 4. DOOR TO HAVE (2) INTERIOR MOUNTED #2 END STILE SLIDE BOLT DOOR LOCKS. P OPERATOR BACKROOM (MIN.) 3 11'-9" X 12'-9" 100,000 480 W8MODEL 524 524 SECTIONS ARE 2" NON-INSULATED 24GA. ROLL FORMED RIBBED STEEL CONSTRUCTION. 1 OF 2 WHITESOLID COUNTERBALANCE SIDEROOM TRACK SIDEROOM SPECIAL NOTE: THE DESIGN OF THE SUPPORTING STRUCTURAL ELEMENTS SHALL BE THE RESPONSIBILITY OF THE PROFESSIONAL OF RECORD FOR THE BUILDING OR STRUCTURE IN ACCORDANCE WITH CURRENT BUILDING CODES. DOOR MASTER SERV INC DBA SUPERIOR ST LUCIE FIRE STATION 10045613-3-1 WC CBUKER 05-26-20 72885 7. DOOR TO BE SUPPLIED WITH A TROLLEY OPERATOR. REFER TO QUOTE OR ORDER ACKNOWLEDGEMENT FOR MODEL, HP, VOLTAGE AND PHASE. MANUFACTURER RECOMMENDS INTERLOCK SWITCHES FOR ALL LOCKED DOOR CONFIGURATIONS. 6. DOOR TO HAVE A 4" 50KSI T-STRUT PER SECTION. A (DOOR)"S" DIM INCLUDES STRUTS & TRACK COMPONENTS WHEN DOOR IS CLOSED S B (OPENING) JAMB DETAILS ADJUSTABLE TRACK MOUNTS M* (TRACK SIDEROOM) 1/2" 5. DOOR TO MEET OR EXCEED +52/-58 PSF DESIGN WINDLOAD AND A +78/-87 PSF TEST WINDLOAD REQUIREMENT. INSIDE WALL ELEVATION OPENING PREPARATION SPRING PAD LOCATION 10" X 12" X 1/4" STEEL (2) REQ'D BY G.C. PRECAST, CMU BLOCK OR MASONRY MEMBERS K F R FINISHED FLOOR LINE 12" E D J G H SIDE ELEVATION STANDARD LIFT TRACK DETAIL P TROLLEY OPERATOR HORIZONTAL TRACK END HANGER BRACKET (SUPPLIED BY DOOR INSTALLER) CLOSES ROLLER CHANNEL. INTERMEDIATE HANGER REQUIRED FOR DOORS 12'-0" AND HIGHER. GALVANIZED STEEL TRACK SECTIONS HORIZONTAL - 14 GA. VERTICAL - 16 GA. DRAWN BY: DRAWING NUMBER: DATE:APPROVAL SIGNATURE: SHEET: CUSTOMER: CSR/DC: APPROVAL DATE: JOB: SHOP DRAWING IMPORTANT: This document must be signed and returned prior to any fabrication. Please reference this drawing number on all correspondence. Thank you! NOTICE: Confidential/Proprietary information of CLOPAY BUILDING PRODUCTS CO. is contained herein and may not be disclosed, used, duplicated, made available, or distributed without its prior consent. Failure to observe this notice may result in liability for any damages and losses resulting therefrom. 7/16" PUSHNUT INSTALLED ON ROLLER SHAFT CENTER HINGE OF 14 GA. GALV. STEEL, FASTENED WITH (4) 1/4" X 5/8" DRIVE SCREWS SECTION JOINT DETAIL INTERMEDIATE HINGE DETAIL CENTER STILE OF 18 GA. GALV. STEEL FASTENED TO EXTERIOR SKIN WITH TOG-L-LOC JOINING SYSTEM DOUBLE END HINGE DETAIL END STILE OF 16 GA. HOT DIPPED GALVANIZED G-40 STEEL WITH NO OIL COATING, FASTENED TO EXTERIOR SKIN WITH TOG-L-LOC JOINING SYSTEM2" ROLLERS FEATURE (1) 1/4" DIA. STEEL BALL-BEARINGS, FULL FLOATING IN CASE HARDENED STEEL RACES. REFER TO HINGE DETAIL ON APPROVED WINDLOAD INSTALLATION DRAWING FOR ADDITIONAL SCREWS REQUIRED FOR W8 APPLICATIONS. ROLLER HINGE OF MIN. 14 GA. GALVANIZED STEEL FASTENED WITH 1/4" X 5/8" DRIVE SCREWS SECTIONS ARE 2" THICK PANELS, ROLL FORMED FROM 24 GA. (0.022" MIN) COMMERCIAL QUALITY STEEL; HOT DIP GALVANIZED PER ASTM A653; PHOSPHATIZED AND FINISHED BOTH SIDES WITH BAKED ON EPOXY PRIMER (0.2 MIL MIN.) AND PRE-PAINTED POLYESTER TOP FACE COAT (0.65 MIL MIN.) ON THE EXTERIOR SIDE. SKIN HAS TWO 1/2" DEEP REINFORCING RIBS ON 8" CENTERS, COMPLEMENTED BY 1/8" DEEP BEADS ON 2" CENTERS. ADJUSTABLE TOP ROLLER BRACKET OF 12 GA. GALV. STEEL, FASTENED WITH (4) 1/4" X 5/8" DRIVE SCREWS MEETING RAILS ARE ROLL FORMED INTO A WEATHER TIGHT TONGUE AND GROOVE JOINT 13 GA. GALV. STEEL STEP PLATE/LIFT HANDLE - MOUNTED TO BOTTOM BRACKET. BOTTOM BRACKET OF 12 GA. GALV. STEEL, FASTENED WITH (5) 1/4" X 5/8" DRIVE SCREWS BOTTOM SECTION REINFORCED WITH A TEMPERED ALUMINUM EXTRUSION WITH INTEGRAL RETAINER AND VINYL SEAL 1/8" DIA. X 7 X 7 AIRCRAFT CABLE & NICO PRESS SLEEVE 2 OF 2 IMPORTANT: PLEASE REFERENCE THE DRAWING NUMBER ON ALL CORRESPONDENCE DOOR MASTER SERV INC DBA SUPERIOR ST LUCIE FIRE STATION 10045613-3-1 WC CBUKER 05-26-20 72885 4" T-STRUT T-STRUT DETAIL