HomeMy WebLinkAboutShop Drawing,10045613-4-1 St Lucie Fire StationsA
C
RJ
#2 END STILE LOCK
QTY = 2 PLCS
1.00" SOLID STEEL SHAFT
SUPPORT BRACKET
SHAFT COUPLER
L.H. WOUND TORSION SPRING
STD LIFT CABLE DRUM
N
ELEVATION VIEW
INSIDE LOOKING OUT
DRAWN BY:
DRAWING NUMBER:
DATE:APPROVAL SIGNATURE:
SHEET:
CUSTOMER:
CSR/DC:
APPROVAL DATE:
JOB:
SHOP DRAWING
DOOR CONFIGURATION
MODEL DESIGN TOP GLAZING FINISHINSUL
IMPORTANT: This document must be signed and returned prior
to any fabrication. Please reference this drawing number on all
correspondence. Thank you!
NOTICE: Confidential/Proprietary information of CLOPAY
BUILDING PRODUCTS CO. is contained herein and may not be
disclosed, used, duplicated, made available, or distributed
without its prior consent. Failure to observe this notice may
result in liability for any damages and losses resulting therefrom.
OVERHEAD CLEARANCEG
DIM.DESCRIPTION DIMENSIONS
QUANTITY OF SECTIONS HIGH
HEADROOM (MIN.)
SPRING PAD OFFSET 1
FLOOR TO CEILING (MIN.)
JAMB HEIGHT (MIN.)
R
M
L
E
F
J
OPENING WIDTH
OPENING HEIGHT
DOOR WIDTH
DOOR HEIGHT
B
D
C
A
N
SHAFT CENTER LINE
SPRING PAD OFFSET 2
BACKROOM (MIN.)
K
QUANTITY OF PANELS WIDE
H
NOTES:
S TRACK BACKROOM
WEIGHT
(LBS)
W8
12'-2"
12'-0"
12'-9"
12'-9"
3
7
1'-10"
14'-7"
13'-4"
14'-8"
14'-7"
5'-6"
0'-4.5"
0'-4.5"
16'-9"
13'-11"
0'-7"
ACTUAL DOOR HEIGHT IS APPROX. 1" OVER BECAUSE OF
JOINTS BETWEEN SECTION PLUS BOTTOM ASTRAGAL
1. ( ) DOOR
2. DOOR TO BE SUPPLIED WITH
CYCLE TORSION SPRINGS.
3. DOOR TO BE SUPPLIED WITH REVERSE
ANGLE MOUNTED, 2" GALVANIZED
STEEL TRACK WITH 15" RADIUS STANDARD LIFT.
4. DOOR TO HAVE (2) INTERIOR MOUNTED
#2 END STILE SLIDE BOLT DOOR LOCKS.
P OPERATOR BACKROOM (MIN.)
2 12'-2" X 12'-9"
100,000
495
W8MODEL 524
524 SECTIONS ARE 2" NON-INSULATED 24GA. ROLL
FORMED RIBBED STEEL CONSTRUCTION.
1 OF 2
WHITESOLID
COUNTERBALANCE SIDEROOM
TRACK SIDEROOM
SPECIAL NOTE: THE DESIGN OF THE SUPPORTING
STRUCTURAL ELEMENTS SHALL BE THE RESPONSIBILITY
OF THE PROFESSIONAL OF RECORD FOR THE BUILDING
OR STRUCTURE IN ACCORDANCE WITH CURRENT
BUILDING CODES.
DOOR MASTER SERV INC DBA SUPERIOR
ST LUCIE FIRE STATION
10045613-4-1
WC
CBUKER
05-26-20
72885
7. DOOR TO BE SUPPLIED WITH A TROLLEY
OPERATOR. REFER TO QUOTE OR ORDER
ACKNOWLEDGEMENT FOR MODEL, HP, VOLTAGE
AND PHASE. MANUFACTURER RECOMMENDS
INTERLOCK SWITCHES FOR ALL LOCKED DOOR
CONFIGURATIONS.
6. DOOR TO HAVE A 4" 50KSI T-STRUT PER
SECTION.
A
(DOOR)"S" DIM INCLUDES
STRUTS & TRACK
COMPONENTS WHEN
DOOR IS CLOSED
S
B
(OPENING)
JAMB DETAILS
ADJUSTABLE TRACK
MOUNTS
M* (TRACK
SIDEROOM)
1/2"
5. DOOR TO MEET OR EXCEED +52/-58 PSF
DESIGN WINDLOAD AND A +78/-87 PSF TEST
WINDLOAD REQUIREMENT.
INSIDE WALL ELEVATION
OPENING PREPARATION
SPRING PAD LOCATION
10" X 12" X 1/4" STEEL
(2) REQ'D BY G.C.
PRECAST, CMU BLOCK
OR MASONRY MEMBERS
K
F R
FINISHED FLOOR LINE
12"
E
D
J
G
H
SIDE ELEVATION
STANDARD LIFT
TRACK DETAIL
P
TROLLEY
OPERATOR
HORIZONTAL TRACK END HANGER BRACKET
(SUPPLIED BY DOOR INSTALLER) CLOSES
ROLLER CHANNEL. INTERMEDIATE HANGER
REQUIRED FOR DOORS 12'-0" AND HIGHER.
GALVANIZED STEEL
TRACK SECTIONS
HORIZONTAL - 14 GA.
VERTICAL - 16 GA.
DRAWN BY:
DRAWING NUMBER:
DATE:APPROVAL SIGNATURE:
SHEET:
CUSTOMER:
CSR/DC:
APPROVAL DATE:
JOB:
SHOP DRAWING
IMPORTANT: This document must be signed and returned prior
to any fabrication. Please reference this drawing number on all
correspondence. Thank you!
NOTICE: Confidential/Proprietary information of CLOPAY
BUILDING PRODUCTS CO. is contained herein and may not be
disclosed, used, duplicated, made available, or distributed
without its prior consent. Failure to observe this notice may
result in liability for any damages and losses resulting therefrom.
7/16" PUSHNUT INSTALLED
ON ROLLER SHAFT
CENTER HINGE OF 14 GA. GALV.
STEEL, FASTENED WITH (4) 1/4"
X 5/8" DRIVE SCREWS
SECTION JOINT DETAIL
INTERMEDIATE
HINGE DETAIL
CENTER STILE OF 18 GA. GALV. STEEL
FASTENED TO EXTERIOR SKIN WITH
TOG-L-LOC JOINING SYSTEM
DOUBLE END HINGE DETAIL
END STILE OF 16 GA. HOT DIPPED
GALVANIZED G-40 STEEL WITH NO OIL
COATING, FASTENED TO EXTERIOR
SKIN WITH TOG-L-LOC JOINING
SYSTEM2" ROLLERS FEATURE (1) 1/4" DIA. STEEL
BALL-BEARINGS, FULL FLOATING IN CASE
HARDENED STEEL RACES.
REFER TO HINGE DETAIL ON APPROVED WINDLOAD
INSTALLATION DRAWING FOR ADDITIONAL SCREWS
REQUIRED FOR W8 APPLICATIONS.
ROLLER HINGE OF MIN. 14 GA. GALVANIZED STEEL
FASTENED WITH 1/4" X 5/8" DRIVE SCREWS
SECTIONS ARE 2" THICK PANELS, ROLL
FORMED FROM 24 GA. (0.022" MIN)
COMMERCIAL QUALITY STEEL; HOT DIP GALVANIZED PER ASTM
A653; PHOSPHATIZED AND FINISHED BOTH SIDES WITH BAKED ON
EPOXY PRIMER (0.2 MIL MIN.) AND PRE-PAINTED POLYESTER TOP
FACE COAT (0.65 MIL MIN.) ON THE EXTERIOR SIDE.
SKIN HAS TWO 1/2" DEEP REINFORCING RIBS ON 8" CENTERS,
COMPLEMENTED BY 1/8" DEEP BEADS ON 2" CENTERS.
ADJUSTABLE TOP ROLLER BRACKET OF 12 GA.
GALV. STEEL, FASTENED WITH (4) 1/4" X 5/8"
DRIVE SCREWS
MEETING RAILS ARE ROLL FORMED INTO A
WEATHER TIGHT TONGUE AND GROOVE JOINT
13 GA. GALV. STEEL STEP PLATE/LIFT
HANDLE - MOUNTED TO BOTTOM BRACKET.
BOTTOM BRACKET OF 12 GA. GALV. STEEL,
FASTENED WITH (5) 1/4" X 5/8" DRIVE SCREWS
BOTTOM SECTION REINFORCED WITH A
TEMPERED ALUMINUM EXTRUSION WITH
INTEGRAL RETAINER AND VINYL SEAL
1/8" DIA. X 7 X 7 AIRCRAFT CABLE & NICO
PRESS SLEEVE
2 OF 2
IMPORTANT: PLEASE REFERENCE THE DRAWING NUMBER ON ALL CORRESPONDENCE
DOOR MASTER SERV INC DBA SUPERIOR
ST LUCIE FIRE STATION
10045613-4-1
WC
CBUKER
05-26-20
72885
4" T-STRUT
T-STRUT DETAIL