HomeMy WebLinkAboutCasey EngineeringDESIGN CRITERIA: APPLI_CABLE_CODES, REGULATIONS & STANDARDS_. 1. THE 2017 FLORIDA BUILDING CODE, SPECIFICALLY CHAPTER 16 STRUCTURAL DESIGN, CHAPTER 20 ALUMINUM & CH. 23 WOOD. 2. AA ASM 35 & SPECIFICATIONS FOR ALUMINUM STRUCTURES, PART 1-A OF THE ALUMINUM DESIGN MANUEL PREPARED BY THE ALUMINUM ASSOCIATION, INC. WASHINGTON D.C. 2005 ED. 3. ASCE 7-10 & SE17 4. NDS NATIONAL DESIGN SPECIFICATION FOR WOOD. 5. ACI318 CONCRETE REFRENCE MANUAL. WIND LOADS 1. BUILDING OCCUPANCY CATEGORY, PARAGRAPH 1604.5 & TABLE 1604.5: RISK CATEGORY 1. 2. BASIC WIND SPEED, TABLE 1609C, STATE OF FLORIDA DEBRIS REGION & BASIC WIND SPEED, PARAGRAPH 1609.3.1 & TABLE 1609.3.1 EQUIVALENT BASIC WIND SPEED: _ 150 MPH EXPOSURE CATEGORY, PARAGRAPH 1609.4.3: C 3. WIND LOADS PER FBC TABLE 2002.4 (MWFRS) VULT = 150 MPH & EXPOSURE = C FOR 20 X 20 X 0.013' MESH SCREEN HORIZONTAL PRESSURES ON WINDWARD SURFACES = 43 PSF HORIZONTAL PRESSURES ON LEEWARD SURFACES = _ 34 PSF VERTICAL PRESSURES ON SCREEN SURFACES = 12 PSF VERTICAL PRESSURES ON SOLID SURFACES = 36 PSF FOR 18 X 14 X 0.013" MESH SCREEN, APPLIED FACTOR = .88 FOR ALLOWABLE STRESS DESIGN, APPLIED FACTOR = .6 FOUNDATION DESIGN FOOTING SIZE EXISTING CONCRETE SLAB. NO ADDITIONAL FOOTING OR FOUNDATION SYSTEM IS REQUIRED BY THE PROPOSED CONSTRUCTION IF A MINIMUM 4" CONCRETE SLAB IS PROVIDED IN SOUND CONDITION, FREE FROM STRUCTURAL CRACKING, SPALLING & OTHER DETERIORATION. EXISTING FOUNDATION/FOOTING UNDER CONCRETE SLAB MINIMUM 8"x8" W/ (1) #5 BAR TO BE VERIFIED BY CONTRACTOR. SEE TYPICAL FOOTING DETAILS FOR NEW FOOTING DESIGN MINIMUM REQUIREMENTS. SPECIFICATIONS THE FOLLOWING SPECIFICATIONS ARE APPLICABLE TO THIS PROJECT: 1. WHERE CONCRETE SPECIFICATIONS ARE REQUIRED, WHETHER IN THE SCREEN ENCLOSURE SCOPE OF NOT, BY ONE OR MORE REGULATORY AGENCY, THE FOLLOWING SPECIFICATIONS ARE APPLICABLE: a. CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING COMPONENTS: i. PORTLAND CEMENT TYPE 1 - ASTM C 150 ii AGGREGATES - LARGE AGGREGATE 3/4 MAX. - ASTM C 33 iii. AIR ENTRAINING +/- 1 %- ASTM C 260 iv. WATER REDUCING AGENT - ASTM C 494 v. CLEAN PORTABLE WATER vi. OTHER ADMIXTURES NOT PERMITTED b. METAL ACCESSORIES SHALL CONFORM TO: i. REINFORCING BARS - ASTM A615, GRADE 60 ii. WELDED WIRE FABRIC - ASTM A185 c. CONCRETE SLUMP AT DISCHARGE CHUTE NOT LESS THAN 3" OR MORE THAN 5". WATER ADDED AFTER BATCHING IS NOT PERMITTED. d. PREPARE & PLACE CONCRETE PER AMERICAN CONCRETE INSTITUTE MANUAL OF STANDARD PRACTICE, PART 1, 2, & 3 INCLUDING HOT WHEATHER RECOMMENDATIONS. e. MOIST CURE OR POLYETHYLENE CURING PERMITTED. f. PRIOR TO PLACING CONCRETE, TREAT THE ENTIRE SUBSURFACE ARE FOR TERMITES IN COMPLIANCE WITH THE FBC. g. CONCRETE SHALL BE PLACED OVER A POLYETHYLENE VAPOR BARRIER. 2. WHEN PAVERS ARE UNDER ALUMINUM MEMBERS, CONTRACTOR SHALL EPDXY TO DECK OR GROUT TO DECK w/3000 PSI GROUT WITH BONDING AGENT 3. WHEN APPLICABLE FOR NEW SLAB ADDITION TO ADJACENT DRILL & EPDXY #5 X 8" REBAR INTO EX. FOUNDATION WITH 1" MIN. HOLE, EMBED 4" MIN W/ NON -SHRINKING SIMPSON EPDXY -TIE (OR EQUAL) 48" O.C. TYP. ALL LOCATIONS 4. WHEN APPLICABLE FOR NEW FOOTER TO EXISTING, DRILL & EPDXY NEW STEEL INTO EX. FOUNDATION WITH 1" MIN. HOLE, EMBED 6" MIN W/ NON -SHRINKING SIMPSON EPDXY -TIE (OR EQUAL) TYP. ALL LOCATIONS 5. MINIMUM CONCRETE STRENGTH 3000 PSI UNLESS OTHERWISE NOTED. ALUMINUM SPECIFICATIONS ALUMINUM MEMBERS DIMENSIONS 1. ALUMINUM EXTRUSIONS SHALL BE 6005 T5 ALLOY UNLESS OTHERWISE NOTED. HOLLOW SECTIONS 2. ALL SELF MATING BEAM SECTIONS ARE TO BE STITCHED WITH 2 x 2: 2"x2"x0.044" # 12 SCREWS 6' FROM ENDS & 24" CENTER TO CENTER. 2 x 3: 2"x3"x0.050" 3. ROOF BRACING SHALL BE A MINIMUM 2"X2"X.050". 2 x 4: 2"x4"x0.050" 4. THE MINIMUM NORMAL THICKNESS OF PROTECTOR PANELS 2 x 5: 2"x5"x0.050" (KICKPLATES) SHALL BE AN INDUSTRY STANDARD OF 0.024 INCHES. OPEN BACK SECTIONS 5. VINYL AND ACRYLIC PANELS SHALL BE REMOVED WHEN 1 x 2: 1"x2"x0.044" WIND SPEEDS EXCEED 75 MPH PER FBC. 1 x 3: 1"x3"x0.045" 6. SCREEN MATERIAL SHALL BE 18/14 SCREEN UNLESS APPROVED BY FLORIDA ENGINEERING LLC. SNAP SECTIONS 5. 1 "X2" & 1 "X3" NON STRUCTURAL MEMBERS MAY BE USED 2 x 2 SNAP: 2"x2"x0.045" INTERCHANGEABLY. 2 x 3 SNAP: 2"x3"x0.050" 2 x 4 SNAP: 2"x4"x0.045" FASTENER SPECIFICATIONS 1. FASTENERS ARE REQUIRED TO BE SAE GRADE 2 OR BETTER ZINC PLATED. (CONCRETE ANCHORS ARE TO BE TAPCONS OR BETTER, INSTALLED TO MFG. SPECIFICATIONS) 2. IT IS THE OWNERS RESPONSIBILITY TO MAINTAIN THE SCREENS, FASTENERS AND SCREENS TO MANUFACTURING SPECIFICATIONS. 3. WHERE WOOD DECK IS PRESENT USE 1 /4" X 3-1/2" GALV. LAG SCREWS IN LIEU OF MASONRY ANCHORS. UNLESS OTHERWISE SPECIFIED. 4. 1"X2" NON STRUCTURAL MEMBERS ATTACHED TO HOST A. FOR MASONRY/CONCRETE APPLICATION USE GALVANIZED 1 /4" X 2-3/4" TAPCONS OR EQUAL AT 24" O.C. AND 6" FROM ENDS B. FOR WOOD APPLICATION USE # 14 X 2-3/4" WOOD SCREW AT 24" O.C. AND 6" FROM ENDS. C. FOR ALUMINUM APPLICATION USE #10 X 1-1/2" SMS OR TEK SCREW AT 24" O.C. AND 6" FROM ENDS D. WHERE 1 "X2" INSTALLED THROUGHOUT AN "OPEN VIEW' SPACING SHALL BE REDUCED TO 18" O.C. AND 6" FROM ENDS MASONRY SPECIFICATIONS 1. CONCRETE MASONRY UNITS (CMU) SHALL BE STANDARD HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED ON TYPE M OR S MORTAR. 2. ALL MORTAR SHALL BE TYPE M OR S. 3. ALL GROUT SHALL BE 2000 PSI MINIMUM AND HAVE MAXIMUM COARSE AGGREGATE SIZE OF 3/8". 4, PROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING REINFORCEMENT WHEN GROUT POUR EXCEEDS 5-0" IN HEIGHT. MISCELLANEOUS 1. SCREENED ENCLOSURES CONTAINING SWIMMING POOLS SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF FBC R4501.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS. 2. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME. IF THE EXISTING STRUCTURE IS ONE OF THESE, A SEPERATE 4TH WALL SUPPORT SYSTEM IS SO TO BE ENGINEERED SO THAT NO ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED HOME. 3. DOOR LOCATION MAY BE RELOCATED BY CONTRACTOR IN THE FIELD. 4, WHERE PAVERS ARE UNDER ALUMINUM MEMBERS, CONTRACTOR SHALL EPDXY TO DECK OR GROUT TO DECK w/3000 PSI GROUT WITH BONDING AGENT. 5. INTEGRITY OF EXISTING/ HOST STRUCTURE SHALL NOT BE COMPROMISED WITH THE ATTACHMENT OF THE PROPOSED STRUCTURE. 6. ALL 2X4 & GREATER ARE TO BE 2 x 4 SMB: 2"x4"x0.044"x0.100" UNLESS OTHERWISE INDICATED. RESPONSIBILITIES 1. ALL SITE WORK SHALL BE PERFORMED BY A LISCENED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDANANCES, AND THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES. 2. FOR FASTENERS WHICH ARE NOT VISIBLE AFTER INSTALLATION, THE CONTRACTOR SHALL VERIFY AND ENSURE INSTALLATION HAS BEEN ACCOMPLISHED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS AND IN ACCORDANCE WITH THE ATTACHED DETAILS. 3. FOR "PICTURE WINDOW" MODIFICATION TO EXISTING SCREEN ENCLOSURES, ALL OTHER "EXISTING SCREEN ENCLOSURE" FEATURES ARE TO MEET THE TYPICAL DETAILS AS PROVIDED IN THESE DETAILS. CONTRACTOR IS TO VERIFY & ASSURE EXISTING SCREEN ENCLOSURE IS STRUCTUALLY SOUND. SELF MATING (SMB) 2 x 4 SMB: 2"x4"x0.044"x0.100" 2 x 5 SMB: 2"x5"x0.050"x0.100" 2 x 6 SMB: 2'k6"x0.050"x0.120" 2 x 7 SMB: 2"x7" x0.057"x0.120" 2 x 8 SMB: 2"x8"x0.072"x0.124" 2 x 9 SMB: 2"x9"x0.082"x0.124" 2 x 10 SMB: 2"x10"x0.092"x0.398" DETAIL A m N Lo m co co 0 0 U CD U Oco a) F' co C ry0)a) U � 0 0- R 0- c o N c c C al N t- ti o co H w U Q U 0 z U W 0 n ry 0 r) U O J O z W W Q W J J 0 U O¢� U) cl� w ��- c) W c } z U af W O z o o WM� a O w (� M J Q�Q d ' U �- z O O af U d DESIGN DATE: 05/21/2020 REVISION 1: DATE REVISION 2: DATE_ PAGE: DRAWN BY: TCP SCALE: NTS O 1X3 2X3 DJ 2X3 D1 2X5SMB c» m N 2X5SMB �tD L 1X3 I N X m I 1X3 + 3X2 1X2 m `. m � cn Ln ` \ Ln X ` x N fV 2X3 TYP`\ 1X3 TYP. 3'-0" 2X3X.050 DIAG. BRACE TYP. -r 4'-0" MAX. N O O O W eq t3 w �O) Q 45ro U CD N Lo 00 --J �� O (y) V ~ 0_ Z z Q E U LL O cr- p U U WJOoo- W < J � LL Ls7 E o z ry -, a)_ W CV ---_�-� 1X3 RR f D cH Z Cy O 2X3DJDJ W 2X3 DJ < --- Q = rY 0 to T— cr- O cy) T- 2X5SMB _I - - - -- -_}- LL CL o I�_ 1X3 ( -8'-6" 2X9 SMB C.B.--- m / ry u1 � - Ln i X i N m i -� O X CQ J 0 W W 1X3 TYP. n Q I U O -- 30 -0 - -- W z 2'-8" - --� Of U w a z Q U)m2 Q U Q M Q F-d O ly c� a DESIGN DATE: 05/21/2020 REVISION 1: DATE REVISION 2: DATE PAGE: DRAWN BY: TCP SCALE: NTS FLASHING "'x2 STEN TO COL (-PRNAL) Wi(2) #T i ill` S,11 S. PASIEN TO EA(_ RAMS ABO'Ni TIOXI-I?2" SMS 2L` O.C. AND 6' FRO�A END ,- TABLE "D" \41 BEAM.'ett �C A5.LE� 2x3 2 x 4 2 5/12 2 x 5 5/12 2 x 6 _--_ 2 X 7 _ -�-- 6lI2 7112 2 x 8 - 8114 2 x 9 --- _- 9 / 14 9 / 14 M f A.N _.IN OF 5/8 SEP RAT10N FRO.l EDGE 07 BEAN S'IS O.C. TYP NOTE: IF PAVERS ARE PRESENT, CONCRETE - ANCHORS < t RA' E I 7 Cl ZN OTING 2 - �7 Y. .,NOTE ALPIN F AS! -EN,NG TO WOOD USE i ' GA - , - o, v CON' �A(NC C AND G,. z /.. T URAR .. N "EA H (TYP 0R17ONTAL OR SLOPED BEAM PER PLAN NOTCHED TO RECEIVE COLUMN WITHIN SMS. (EACH SIDE) 01 Y FIER TABLE D NOTCH PROF!LE MAY VARY 0 PERMIT CORRECT # EMS COLUMN PER PLAN DETAIL 'E" - UPRIGHT TO BEAM CONNECTION SCALE: N.T.S. 1/4" UPRIGHTTOTY. 2X3_ 2X4 2X5 DIA. TAPCON SCHEDULE TAPCONI OTY. 912 SMS E/S (1) 1/4" TAPCON/ (4) #12_ (2) 1/4" TAPCON/ (4) #12 (2) 1/4" TAPCON/ (4) #12 2X6_ (3) 1/4" TAPCON/ (6) #12_ 2X7 (3) 1/4" TAPCON/ (6) #12 2X8 (4) 1/4 TAPCON/ (8) #12 2X9 2XIO (4) 1/4' -IAPCON/ (8) #12 (5) 1/4" TAPCON/ (10) #12 SCHEDULE BASED ON 2-1/4' MIN. CONCRETE ANCHOR EMBEDMENT 1;8"xZ"x2'x. ANGLE ° 5032 H-32 ANGLE (2) - #:2 SMS INTO COLUMN MASONRY ANCHOR EACH ANGLE - EACH SIDE COL. 0 01 Z--i/4" MIN, CON,. 0 0 I ANCHOR EMBEDMENT G 3000 PSI CONE, a SLABI FTG 6x6-10x10 WWM SIDE VIEW OR FIB RMESH /LA MASONRY ANCFOP AT EACH ANGLE (2) a1Gn2" INTO BEAM BEAM 5 BRACE 0 CORNER 3/8" DIA. TAPCON SCHEDULE 1 UPRIGHT OTY. TAPCON/ CITY. 912 SMS E 2X3 (1) 3/8" TAPCON/ (4) #12 2X4 (2) 3/8" TAPCON/ (4) #12 2X5 (2) 3/8" TAPCON/ (4) #12 1 2X6 (2) 3/8" TAPCON/ (6) #12 2X7 (2) 3/8" TAPCON/ (6) #12 2X8 (3) 3/8 TAPCON/ (6) #12 f 2X9 (3) 3/8" TAPCON/ (6) #12 _ 2X10 (4) 3/8" TAPCON/ (8) #12 SCHEDULE BASED ON 2-U4` MIN. CONCRETE ANCHOR EMBEDMENT SELF -MATING OR SNAP SECTION TYP, PER PLAN I'r,2' 0.B- BASE PLATE-TYP. 7-1/L" MIN- CONE. �— ANCHOR EMBEDMENT ZA MIN. ANCHOR SPACING WHEN GREATER THAN 2,A a UPRIGHT IS USED SEE TAPCON SCHEDULE ABOVE 2-#12 SMS i/C TAPCON XL (RED HEAD MFG. OR EOUAL) 2 @ Ix2 BASE 2 @ SLAB (BEYOND) BASE PLATE ANCHORED TO CONE vri VA' MASONRY ANCHOR 6' MAX EACH SIDE OF POST AND 2L' O.C. MAX 3000 PSI CONE. --- -- SLAB/ FTG 6x6-10,10'.4P1M FRONT VIEW OR FIBERMEShi DETAIL "B" - 2"W' OR LARGER SELF MATING UPRIGHT TO DECK DETAILS SCALE: N.T.S. (2) #10x3 SMS INTO SCRErJ BOSSES FOR EDGE `"EMBER DETAIL "D" - ROOF BRACING CONNECTION SCALE: N.T.S. EDGE MEMBER OR PURLIN G 062 '6063 6 FLAT PLATE (8) 0X31SMS MIN. 12 EDGE DISTANCE PLATE MAY BE PAST _NED N7PRN4t-t Y TO BRAG_ r ❑FRS PER PLAN' PAGE 2 . _ R_ VARY PER L-'N °AGE 2 FASTEN TOP OF HEADER TO R ER (z): o n .. "P IAT ION INTO R , BOSS 0- -r ,YP BOTH, S,OES DOOR JAMB PER PLAN FASTEN HEADER ,(2) #I0x3' INTO SCREW BOSS OF HEADER ALTERNATE HEADER CONNECTION INHEN 7-BAR IS USED - FASTEN Z-BAR TO COLIHEADER AT EACH CORNER AND 18" O/C ALTERNATE BASE PLATE CONNECTION! ATTACH MEMBER TO BASE PLATE tNTERNU vs/(2)ERN"L) r�l(2) #(Ox2" SMS ATTACH BASE PLATE TO MEMBER ul(2) K!0x3" SMS INTO SCREW -� BOSS OF BASE PLATE 'ILUMINUM INTERNAL OR RECEIVING CH P- rc INTO GIRT OR PURLIN 8 (2) - 7- INTO BEAK` OR UPRIGHT C G 2 : ' E C_PS f ( : t x2' SmS IN 0 SCR *BOSSES URLIN UPRIGHT, BEAM —SNAP, `tEMBER S_. MATING. OR HOLLO,V DETAIL "C" - GIRT OR PURLIN TO BEAM OR POST DETAIL SCALE: N.T.S. �Y °° ° ° ° ° °� a°" °n IL" TAPCON (RED HEAD MFG. OR EOU ) it - H N 6" OF COLUMN 8 cam0 C_ MAX. 1 ,/L" PENETRATION INTO UNDERLYING FOOTING DETAIL 'IF" - DOOR JAMB & HEADER CONNECTION SCALE: N.T.S. S,2 x 06 DIM, TO MATCH P iRLIN SIZ C ,NG CHANNEL (2) S (. RNAL RA (3) 12 -AC SIDE x2 C _N cAi EA-1 R-GON (2) #t0x2" SMS THRU X2 INTO -AVE RAIL EACH SIDE OF COLD! DETAIL "G" - SLOPED PURLIN CONNECTION SCALE: N.T.S. ! a I O � ui i LLi qJ r O D ' U N co p J — rn cl) i- cy') Z Q E � W U O U I.L O� (p U LU O 00 W�LLLn.� 1rn r W Z 75 O� Li .0 a� QQ= 3: o F— U r 0� 1-U2'x WEI' PLATE (12) #12W SMS (TOP OR BOTTOM) @ i" SPACING Q U p 2"x2" EDGE BEAM J O (2) #10x3' SMS W INTO SCREW BOSSES U O Q CONNECTING EDGE BEAM TO PURLIN U) U "x2"FASTENED TO COLUMN } ;.10 #10x1-112" SMS INTO W a Z SCREW BOSSES FOR SMB �- OR SNAP COLUMN 0 z Q W M I"x2` SNAP F 0- w U ('7 co 0- W NOTCH COLUMN AS REO'D. Z COLUMN PER PLAN O IL v _ a DESIGN DATE: 05/21/2020 REVISION 1: DATE ALTERNATE DETAIL "G" SLOPED REVISION 2: DATE PAGE: PURLIN CONNECTION SCALE: N.T.S. DRAWN BY: T_CP SCALE: NTS G:RT F.,SEN.D INTERNALLY AlEACH END ., ..E _ACH SCREW GROOVEFAST TG "`-. ,., 2x2s.:25 ANGLE (2) #:2 SMS #C J1 THRU ANG'_ ,NTO ;? -.. r_ NO GIRT IS PRESEN•. ATTAtti ..w-a. DIRECTLY TO GUTTER -\ 2'I:2 u.ANGLE I t2 z SMs ORB .�M - BOd_ 2,8 INSTAL_ GUTTER BRACE _ AT MIDPOINT B % nE'-,8 'NCI 2" vL .-R BRACE .,T EACH BEADS _OCATQN BEAM ° FO,. G . ER TC FASCIA: (2) #12 SMS (1) 2 !8` 0 C ° FOR GUTTER BRACE/ STRAP- (2) =1A EA. STRAP CLOSE BOTTOM OF o o l B WHEN E RIMMED S OE VIEW RECE 1CHANNEL Pi \\ a I� (2)) 12 SMS FOR BEAM OVER Zx5 EACH SOE OF BEAM -0AL RECEIVING C6iANN•-EL TO S .RUCTURAL GUTTER INTERNALLY 1(2) i2 EMS L E RNATEL'+ 2x2x.:8" ANGLE BELOW G R 12) FIL SMS INTO AM 8 (2) 12 S , 1NTG S RUCTUR GU- trc SIDE VIEW GIRT =10 SMS 'N!T*!M 6" 0 EAM Cl 24" 0-C. 2,2,118" ANGLE -A. SIDE OF wi(2) #12 SMS EACH LEG EACH S�DE TOP VIEW DETAIL "H" BEAM TO GUTTER CONNECTION SCALE: N.T.S. S.:.N GUTTER TO SC;A If #!Al2- OO SCREW 18" O.C. 1 -2 SMS (2) a,:.x2.. A00D SCREW ASc (2^...6" MIN. STRU'TURA. - 1-- 0 F o o 0 o o of 1 o ° o ° \\\ r ° o 0 0 0 0 o 0� c \` y o 3/i6"-SO52--H32 GUSSET o \ _ F INTERNAL OR EXTERNAL 8" INTO EA. SIDE TYP. (2XIOSMB ILLUSTRATED) NOTE r INSTAL! FASTENERS ALONG PERIMETER OF GUSSET -BEAM JOINT 3/8''MIN, FROM EDGE. FASTENERS MAY BE STAGGERED TO INSURE PROPER QUANTITY PER TABLE B-I FASTENER PATTERN MAY APPEAR DIFFERENT FROM ILLUSTRATION, MAINTAIN t%2" SEPARATION BETWEEN FASTENERS. MAINTAIN 3B" MIN, FASTENER SEPARATION FROM BEAM JOINT OR EDGE OF BEAM LAP FASTENERS MAY BE EVENLY SPACED AROUND EDGE OF GUSSET WITHIN 318' OF BEAM JOINT. FASTENER MAY BE STAGGERED TO INSURE PROPER QUANTITY PER TABLE B-I TABLE B-I BEAM SIZE CGl TO d�Af GTY 5, c/ �1Dc Cr COL- _ BEAM TO BEAM OTY SMSI FACE/SIDE 2 x 4 (5) #12 (9) #12 2 x 5 (5) #12 (9) #12 2 x 6-----_(7) #12 (9) #12 2 x 7_--- -_(10) #12 (10) #12 2 x 8 (12) #12 _- (14) #12 2 x 9 (14) #14 (14) #14 2 x 10 _ (16) #14 (15) #14 DETAIL "K" GUSSET CONNECTION SCALE: N.T.S. 050'G U T T __ „7!PFNER (Z) 2'.0- SCREW ASI EN TC G;, TER w(2) a:2 SMS GUTTER GUTTER WHEN BEAM 8 HIT ON CORNER - FASTEN OUTSID^ OF BEAM 8 BuRL"N w/ '8`x2"x2 ANGLE 6 (A) #12 SMS EACH LEG FASTEN NSOE CORNER (BEAM OFURL - ') vr! t8'x2 xt ,.,aGLE nz)'12 SMs INTO EA NIzMEER (BEAM 8 PORLIidt DETAIL "M" BEAM & PURLIN TO GUTTER CONNECTION SCALE: N.T.S. - (2) #G. WOOD SCREWS (2) #i2 SMS INTO FA --CA 2:t2aI/8" ANGLE wH2} GIRT :2 S"S _L. LEG 0 0 SMB — 8 AT YGL OR .'8 a2 a w Zi w/( < 4 AEI. RSEC G MEMBER PER!METE FRAMING DETAIL 1-2" CABLE CONNECTION AT CORNER SCALE: N.T.S. N O_ O M r,.�..- W C O � N � C � ui U � N J c:) r f- (`) zzQ o o ) o N LL L.l_ Q U (� O 00 0, W Q J C� LL z � I " W a) I— co c- UJ < I aa) cr Cy) EYEBCLT FOR /�- CABLE TENSION 0 rK� 1 O Q- u8' STAINLESS STEEL BRAIDED CABLE I `+ H - I•E STAIN- PSS STEEL VB 2"xL"� RAP STRUCTURAL OUT, BRAIDED CBLE (2) 12 S.) INTO BEAM SIDE VIEW Aoo MiN. f2) =12 S, INTO OUT, I ER 500 MAX. GIRT ! (2) GUTTER BRACES FASCIA EACH wl(2) #12 SMS INTO GUT i ER 8 (2) #IA R. 2" A` MUd. SLAB :HOOD SCREWS INTO FASCIA yr/FOOTNG 3/8" DIA r. 3" EMBED CONC.SCREW ANCHOR 2x2x; l8` ANGLE AIM° - (TAPCON OR EQUAL) =i2 SMS EA. LEG 4 __- 3000 PSI CONC. 6x6-IO:.'IO AOD MIN- WVJM OR FIBERMESH SMB 60I MAx , '_ 178"x2"xL' STRAP (2) #12 IS INTO BEAM GIRT - (2 #!2 SMS INTO GUTTER STRUCTURAL GUTTER ` A" MIN. SLAB TOP VIEW w/FOOTING L5'x5.5' ALUM. STRAP vd(2) 1/4" DIA. x 2-I/A" MASONRY ANCHOR DETAIL "L" CORNER GUTTER IT OR EQUAL) CONNECTION SCALE: N.T.S. DETAIL "I-1" CABLE CONNECTION AT FOUNDATION SCALE: N.T.S. 3000 PSi CONC. 6x6-10a!O ! 4J`! OR FIBERMESH 00 I- C:) M E- W U Q U (.0 N O z W 0 U Q J J O z W w w v -j ¢ o u- r W U�S� W } ZU W F- z o U) co Q U Q M Q w U r- W Z O p Of C) D- DESIGN DATE: 05/21/2020 REVISION 1: DATE REVISION 2: DATE PAGE: DRAWN BY: TCP SCALE: NTS - - - - - - _ ---- -- — - ------ -- I 3/16" 5052-H32 GUSSET - - 1" X 2" O.B. FASTENED TO CORNER #14 SMS @ 1 1/4" O.0 POST W/ #12 X 1 1/2" SMS AT 6" FROM -- 2"X2" X 1/8" X 4" ANGLE 2" X PURLINS ATTACH TO - --�, --- - TOP &BOTTOM RAILS TYPICALLY @ 24" O.C. PROVIDE #14 X 1" INTO EACH -- BEAM WITH MIN (4) #10 X 1 1/2" SMS 1/8" X 2" X 2" EXTRUDE ANGLE 5052 MEMBER AS INDICATED BELOW PLACE WASHER UNDER SCREW -� - H-32 ALLOY EA CORNER W/ (2) #14 X 2" IN GUSSET CORNER CORNER POST -SMS INTO POST & (1) 3/8" DIA - SCREW ANCHOR INTO CONCRETE 0 0 0 6" o 0 0 0 } ° (2) #10 X 1 1/2" SMS 1~ - 1 1/4" (TYPICAL) o tz THRU SCREW BOSSES z va MJv coNc \ 5" NCHOR EMBEDMENT 5" ---X23� a''� � � SLAB/FOOTING l NOTES: SEE PLAN L`_ _,`. ; (r} �— M c LL NOTES: _ 1. CONNECTION DETAIL �_ 0 U C AT EAVE RAIL SIMILAR SIDE VIEW_ U 1. GUSSET DIMENSION ARE MINIMUM (2) O _ REQ'D (1) EA SIDE OF BEAM - MAYBE UJ—I INTERNAL OR EXTERNAL I cr) 2. AS BEAM SIZE CHANGES, ADD OR CORNER K-BRACE DETAIL uJ Q LL r SUBTRACT SCREWS TO MAINTAIN 1-1/4" C/C SPACING SCALE: N.T.S. ry 3. GUSSET LENGTHS REMAIN CONSTANT z WIDTHS CHANGE TO MATCH BEAM SIZE. I — 2"X2"X1/8" ANGLE X 4" LONG PROVIDE #14 X 1" INTO EACH MEMBER AS INDICATED BELOW PROVIDE INTERIOR ANGLE ABOVE AND BELOW CHAIRRAIL EXTERIOR PLATE CORNER POST - EAVE RAIL 1"x2"O.B. PATIO SECTION 3" x 3" x 0.050" MIN., 6063-T6 ALLOY PLATE DR STRONGER (ONE SIDE) WITH (3) - #12 x 314" S.M.S. EACH SIDE AS TOWN (3/8" MIN. PLATE EDGE DISTANCE & C-C FASTENER SPACING) 2x2X0.033, BkACE (TYP K-BRACE LATERAL "K"-BRACING CONNECTION DETAILS GUSSET PLATE PER E-SERIES PURLIN M MrAli 44-1 3" x 2" x 0.050" MIN., 6063-T6 ALLOY PLATE DR STRONGER (ONE SIDE) (3) - #12 x 3/4" S.M.S., EACH SIDE AS SHOWN (1/2" MIN. PLATE EDGE DISTANCE & C-C FASTENER SPACING) SELF MATING BEAM CONTRACTOR TO INSTALL (2) #14 X 2" SMS THRU BRACE INTO BEAM THRU GUSSET PLATE CORNER POST K-BRACE 2"x2x0.093 BRACE(TYF 3/8" 0 CONCRETE ANCHOR (2 PLATES) FOUNDATION / IN LIEU OF TYP. 1/4" 0 CONCRETE SCREWS FOR CORNER COLUMN LATERAL "K"-BRACING CONNECTION DETAILS —J (4) #14 X 3/4" SMS INTO POST 1" X 2" BASE PLATE ANCHORED TO CONC W/ 1/4" CONCRETE SCREW ANCHOR (MIN. 1 1/4" EMBED) 6" MAX EACH SIDE OF POST AND 24" O.C. MAX FRONT VIEW 2" CORNER POST W/ 1" X 2" @ 4,—,.-/ BAC KSI D E 3/8" X LENGTH AS REQUIRED FOR 2 114" EMBED CONCRETE SCREW ANCHOR INTO CONCRETE CP-1 CORNER POST TO CONCRETE DETAIL A-4 SCALE: NTS 6" x 5" x 0.050" 6063-T6 ALLOY PLATE - (ONE SIDE) OR STRONGER 2 x 2 x 0.093 BRACE (TYP.) K-BRACE — 2 x 3 x 0.070 CHAIR RAIL \ O A i ® o K-BRACE i o —Q - — O 2x2x0,093 BRACE (TYP.) (11 TOTAL) - #12 x 3/4" S.M.S. AS SHOWN (1/2" MIN. PLATE EDGE DISTANCE & LATERAL "K"-BRACING C-C FASTENER SPACING) CONNECTION DETAILS COLUMN i I A 1 GIRT (CHAIR RAIL) (2) 1/4" DIA. MACHINE _ BOLTS w/ WASHERS 3"x3" POST (SEE PAGE-2 (2) 3/8" DIA. EXPANSION BOLTS FOR SIZE) SEE NOTE # 1 THIS PAGE - FOR BOLT PLACEMENT "x3''x0.145ANGLE 3000 PSI CONC. / SLAB/FTG. FRONT VIEW 6x6-1Ox10 WWM OR FIBERMESH 3"x3" POST CONNECTION DETAIL SCALE: NTS (3) 1/4" DIA. MACHINE BOLTS w/ 3/4" DIA. WASHERS THRU CARRIER BEAM & POST 2'x2' FASTENED TO CARRIER BEAM w/(2) # 10x1-1 /2' SMS INTO SCREW BOSSES EACH END 0) CARRIER BEAM \- I"x2' MEMBER FOR SCREENING VARIES -HORIZONTAL BEAM ON ITS SIDE POST (IF REQUIRED) _--- ------ -� Z' FOR SINGLE 2"x2'k0.125' HORIZONTAL BEAM RECEIVING CHANNEL OR At,IGLE EACH SIDE -- 4" FOR DOUBLE HORIZONTAL (6) # IOxO.75" SMS BEAM OR 4'k4" EACH SIDE 6" FOR TRIPLE HORIZONTAL (12) # 1 Ox0.75"SMS BEAM OR 6X6 2 ROWS OF (6) FOR RECEIVING CHANNEL OR (6) EACH ANGLE CARRIER BEAM TO POST DETAIL SCALE: NTS CARRIER BEAM 2"x2"xO.125' RECEIVING CHANNEL ROOF BEAM (SLOPED OR FLAT) (NOTE USE SIMILAR DETAIL. FOR NOTCHED UPRIGHT CONNECTION TO CARRIER BEAM 1"XZ' MEMBER FOR SCREENING 3/4"SMS SEE TABLE FOR SCREW \ SIZE/ QUANTITY (TYP. EACH SIDE) (2) ROWS OF 3/4" SMS SEE TABLE # Ioxl-1 l2" SMS <;" 24" FOR SCREW SIZE/ QUANTITY O.C. MAX CONNECTING --� TO 1"x2" CARRIER BEAM NOTE: FOR DOUBLE OR TRIBLE CARRIER # 1 Ox 1-1 /2' SMS 4 24" BEAM, OUTSIDE WEBS SHALL OVERLAP O.C. MAX CONNECTING -- 4x4 POST OR NOTCH POST AS ABOVE 70 1'k2" POST FOR 6x6 POST. ALL CASES, CONNECT USING MACHINE BOLTS DECRIBED ABOVE. ROOF BEAM TO CARRIER BEAM CONNECTION DETAIL SCALE: NTS (2) 3/8" DIA. EXPANSION BOLTS SEE NOTE # 1 THIS PAGE FOR BOLT PLACEMENT (2) 3/8" DIA. EXPANSION BOLTS SEE NOTE # 1 THIS PAGE FOR BOLT PLACEMENT 12) 1/4" DIA. MACHINE BOLTS w/ WASHERS Z' FROM EDGE 2' FROM EDGE � ,7in �] OF SLAB( FTG. OF SLAB/ FTG. ---- — 3"x3" POST TOP VIEW (SEE PAGE-2 FOR SIZE) (2) 1/4" DIA. MACHINE BOLTS w/ WASHERS (2 TOTAL PER POST/SMB CONNECTION) (2) 3/8" DIA. EXPANSION BOLTS SEE NOTE # 1 THIS PAGE - FORBOLTPLACEMENT 2" FROM EDGi OF SLAB/ FTG. Z'x SMB (SEE PAGE-2 FOR SIZE) (2) 1/4" DIA. MACHINE -' BOLTS w/ WASHERS i Z' FROM EDGE OF SLAB/ FTG. TOP VIEW STITCH w/(2) # 12x3/4" SMS 12" O.C. - 2"x_ SMB -(SEE PAGE-2 FOR SIZE) r- 3"x3"x0.125" ANGLE 3000 PSI CONC. SLAB/FTG.- FRONT VIEW 6x6-1Ox10 WWM OR FIBERMESH 3"xX POST w/ 2x SMB CONNECTION DETAIL SCALE: NTS NOTES: 1. 3x3 POST TO HAVE 3/8" RED HEAD - TRUBOLT WEDGE ANCHORS (STAINLESS STEEL, PROVIDE MINIMUM 2" FROM EDGE OF SLAB AND PROVIDE MINIMUM 2" SPACING TO ANY OTHER CONNECTOR. SEE MFG, NOTES FOR INSTALLATION REQUIREMENTS. THREADED ROD REQUIRES 3" MINIMUM EDGE DISTANCE. 2. 4x4 POST TO HAVE 1/2 " RED HEAD - TRUBOLT WEDGE ANCHORS (STAINLESS STEEL, PROVIDE MINIMUM 3-3/4" FROM EDGE OF SLAB AND PROVIDE MINIMUM 3-3/4" SPACING TO ANY OTHER CONNECTOR. SEE MFG. NOTES FOR INSTALLATION REQUIREMENTS. 3. WHERE PAVERS ARE PRESENT ANCHOR LENGTH SHALL BE INCREASED BY THICKNESS OF PAVER NOT TO EXCEED 2-1/2" FOR PAVER THICKNESS MORE THAN 2-1/2" SPECIFICATIONS SHALL BE REQUIRED. PAVERS SHALL BE BONDED TO UNDERLYING CONCRETE FOUNDATION. ROOF BEAM TO C.B. W/ REC. CHANNEL TABLE BEAM SIZE 2 x 4 2 x 5 QUANTITY/ SIZE LEG TO BEAM E/S (4) # 12 OR (2) # 16 (5) # 12 OR (3) # 16 QUANTITY(SIZE TO BEAM. INTERNAL. i (8) # 12 OR (3) # 16 (10) # 12 OR (3) # 16 2 x 6 2 x 7 (5) # 12 OR (3) # 16 (6) # 14 OR (4) # 16 (10) # 12 OR (4) # 16 (12)#14OR(4)#16 2x8 (7) # 14 OR (4) # 16 (12)#14OR(6)1,16 2x9 2x10-(9)#14OR(6)#16 18) # 14 OR (5) # 16 (14) # 14 OR (6) # 16 (14) # 12 OR (7) # 16 (2) 1 /2" DIA. EXPANSION BOLTS SEE NOTE #2 THIS PAGE FOR BOLT PLACEMENT (3) 1/4" DIA. MACHINE BOLTS_ - w/ 3/4" DIA. WASHERS THRU POST CARRIER BEAM & POST TOP VIEW on CARRIER BEAM I O (3) 1/4" DIA. MACHINE BOLTS w/ 3/4" DIA. WASHERS THRU CARRIER BEAM & POST POST BEAM (3) 1 /4" DIA. MACHINE BOLTS w/ 3/4" DIA. WASHERS THRU CARRIER BEAM & POST FRONT VIEW CORNER CARRIER BEAM CONNECTION DETAIL SCALE: NTS t — � 3-3/4" FROM EDCE 3-3/4" FROM EDGE OF SLAB/ FTG. OF SLAB( FTG.---------_-- � -(3) 114" DIA. MACHINE BOLTS w/ WASHERS (4) 3/8"x4" TAPCON THRU BOTTOM LEG OF ANGLE INTO CONC. 1' (3) 1/4" DIA. MACHINE- BOLTS w( WASHERS I 2" 3-3/4" FROM EDC 1" OF SLAB/ FTC. J -v— U) co 0 C`7 Z Q O Z — U �—/ 1_I_ CY O U W 0 00 - 1 0) Lo V WQ_�(1) \� 4— U �— ry o (o H j O n N O O W 0_ c N e4 a C U W rn W � H- v to N ti O M F- 0_ W U U o N O U W ry 0- TOP VIEW (3) 1/4" DIA. MACHINE TOP VIEW BOLTS w/ WASHERS 4"x4" POST (2) 1/2' DIA. EXPANSION (SEE PAGE-2 -COLUMN PER PLAN BOLTS SEE NOTE #2 FOR SIZE) THIS PAGE FOR BOLT (3) BOLTS Iw/ WASHERS PLACEMENT i /8"x7'x2'x3-3/4" 2"x4'k0.125 ANGLE (LENGTH) ANGLE ON - (THRU BOTTOM T M LEG (INTERNAL) U O THRU BOTTOM LEG I OF ANGLE INTO CONC. J O ., W QJ - e> ry a OLL 3000 PSI CONC. —a--- sLA6/ FTG. FRONT VIEW 3000 PSI CONC. ° W � U Z U 6x6-1Ox10 WWM SLAB/ FTG.- FRONT VIEW W p OR FIBERMESH 6x6-1Ox10 WWM O p W OR FIBERMESH Z ¢ (n co J 4"x4" POST CONNECTION DETAIL 4X4 COLUMN ALT. BASE ATTACHMENT Q O Q M Q SCALE: NTS DETAIL SCALE: NTS o_ U a o ° c� a DESIGN DATE: 05/21/2020 REVISION 1: REVISION 2: PAGE: DRAWN BY: TCP SCALE: NTS