Loading...
HomeMy WebLinkAboutEnergy Code, FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential TeFla IVED Project Name: MIRIAM SUE MURRELL Builder Name: MAR 12 2020 Street: 161 SE SERENATA COURT Permit Office: City, State, Zip: PORT ST. LUCIE , FL, Permit Number: ST. Lucie County, Permitting Owner: MIRIAM SUE MURRELL Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or ebsting Addition 9. Wall Types (582.1 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Frame - Wood, Exterior R-13.0 582.08 ft' b. N/A R= fill 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms(Bednns In Addition) 0(0) d. N/A R= ft' 10. Ceiling Types (256.0 sgft.) Insulation Area 5. Is this a worst case? No a. Cathedral/Single Assembly (Unvented)R=30.0 256.00 ft 6. Conditioned floor area above grade (ft') 256 b. N/A R= ft' c. N/A R= ft' Conditioned floor area below grade (ft') 0 11. Ducts R ft' 7. Windows(16.0 sgft.) Description Area a. U-Factor: Sgl, U=0.65 16.00 ft' SHGC: SHGC=0.25 b. U-Factor. N/A ft' 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 12.0 SEER:19.00 c. U-Factor. N/A ft' SHGC: 13. Heating systems kBtuthr Efficiency d. U-Factor: N/A ft' a. Electric Heat Pump 12.0 HSPF:9.50 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems - None required a. Cap: N/A B. Floor Types (256.0 sqft.) Insulation Area EF:-5.22418E017 a. Slab -On -Grade Edge Insulation R=0.0 256.00 ft' b. Conservation features b. N/A R= ft' c. N/A R= ft' 15. Credits Patel Glass/Floor Area: 0.063 Total Proposed Modified Loads: 8.73 PASS Total Baseline Loads: 11.25 I hereby certify that the plans and specifications covered by Review of the plans and O ES this calculation are in compliance with the Florida Energy specifications covered by this „ O*, Code. calculation indicates compliance the Florida Energy Code.PREPARED �with BY: [_ ).1/� Before constructionis completedDATE: 3-10-20Qo@a this building will be inspected for compliance with Section 553.908 a Y. hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. COD {yEv OWNER/A E T UILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (11402.4.1.2). 3/9/2020 4:20 PM EnergyGaugera USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition Qom t 10 SPage 1 of 4 7 4FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: MIRIAM SUE MURRELL Bedrooms: 0 User Conditioned Area: 256 MIRIAM SUE MURRELL Total Stories: 1 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: No Whole House Fan: No Single-family Addition Address Type: Street Address Lot# Block/Subdivision: PlatBook: Street: 161 SE SERENATA CO County: St. Lucie City, State, Zip: PORT ST. LUCIE , FL, CLIMATE Design Location Design Temp TMY Site 97.5 % 2.5 % Inl Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 256 2406.4 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 ENCLOSED ROOM 256 2406.4 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpel 1 Slab -On -Grade Edge Insulatio ENCLOSED ROO 55 ft 0 256 ft2 ---- 0 1 0 ROOF # Type Roof Gable Roof Materials Area Area Color Red Barr Solar SA Emitt Emill Deck Pitch Absor. Tested Tested Insul. (deg) 1 Gable or shed Composition shingles 270 ft2 42 ft2 Medium N 0.5 No 0.9 No 0 18.4 ATTIC # Type Ventilation Vent Ratio (1 in) Area RIBS IRCC 1 No attic Unvented . 0 256 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Cathedral/Single Assembly (UnvENGdLOSED ROO 30 Blown 256 ft2 0.1 Wood 3/9/2020 4:20 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 !IFORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 N 2 E 3 S 4 W Exterior Frame - Wood Exterior Frame -Wood Exterior Frame - Wood Exterior Frame - Wood ENCLOSED 13 7 0 10 7 74.1 ft' 0 ENCLOSED 13 16 0 10 7 169.3 ft2 0 ENCLOSED 13 16 0 10 7 169.3 ft' 0 ENCLOSED 13 16 0 10 7 169.3 ft2 0 0.25 0.6 0.25 0.6 0.25 0.6 0.25 0.6 0 0 0 0 DOORS # Ornt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 W Insulated ENCLOSED None .39 3 7 21 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / V # Wall Omt ID Frame Panes Overhang NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S 3 Metal Low-E Single Yes 0.65 0.25 N 16.0 ft2 2 ft 0 in 1 ft 4 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000299 200.5 11.01 20.7 .1104 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heal Pump/Suppleme Split Singl HSPF:9.5 12 kBtu/hr 1 Ductless COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/Supplemental for Split Singl SEER: 19 12 kBtu/hr cfm 0.7 1 Ductless SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector System Model # Collector Model # Area Storage Volume FEF ft2 3/9/2020 4:20 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 ,'J=oRM R405-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programablre Cfreiling Fans: ]Thermosta[[t:]]Y [[ ]] Mar MayX] r Dec Heatiov ng Jan [)q Feb [)9 Apr May Jun 4 Jul 4 Aug Sep Oct ([rj Nov € Dec Venting [) Jan l l l 11 Feb ll�xll Mar [ ] Jun [ [ [X Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 lbs/s .ft. 0 ft' 0 ft 0.3 ENCLOSED ROOM 3/9/2020 4:20 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 78 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. Addition 12. Ducts, location & insulation level a) Supply ducts R 2. Single-family or multiple -family 2. Single-family b) Return ducts R c) AHU location 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 0 13. Cooling system: Capacity 12.0 a) Split system SEER 19.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 256 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.650 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 14. Heating system: Capacity 12.0 c) Area 7c. 16.0 a) Split system heat pump HSPF 9.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. 13.0 e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2, f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. b) Cross ventilation No b) Single assembly 11b. 30.0 c) Whole house fan No c) Knee walls/skylight walls 11C. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be comple ed based on inst led code compliant features. Builder Signature: f_ f�. ".- ._+ Date: 3J c20�� Address of New Home: 161 SE SERENATA COURT City/FL Zip: PORT ST. LUCIE, FL 3/9/2020 4:20:23 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 78 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. Addition 12. Ducts, location & insulation level a) Supply ducts R 2. Single-family or multiple -family 2. Single-family b) Return ducts R c) AHU location 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 0 13. Cooling system: Capacity 12.0 a) Split system SEER 19.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 256 d) Room uniUPTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.650 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 14. Heating system: Capacity 12.0 c) Area 7c. 16.0 a) Split system heat pump HSPF 9.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) Ba. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. 13.0 e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. b) Cross ventilation No b) Single assembly 11b. 30.0 c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be competed based on installed code compliant features. Builder Signature: Ok'' '+ c - Date: Address of New Home: 161 SE SERENATA COURT City/FL Zip: PORT ST. LUCIE, FL 3/9/2020 4:20:23 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1