HomeMy WebLinkAboutEngineering, SETUP AND INSTALLATION OF SINGLE WIDE SHED 1. BUILDING IS PLACED IN REQUESTED LOCATION ON SCHEDULE 40 PVC TO ALLOW FOR MOVEMENT TO PLUM OR SQUARE UNIT TO HOUSE, FENCE, PROPERTY UNE, ETC. 2. ONCE UNIT IS SQUARE AND THE HIGH SPOT OF THE GROUND IS ESTABLISHED, THE BUILDING IS BLOCKED O THE HIGH SPOT AND TH N N LEVELED. E OTHER END OF THE BUILDING IS BROUGHT UP TO LEVEL AND BLOCKED. THEN THE CENTER OF THE BUILDING IS SUPPORTED TO LEVEL, BLOCKED, AND THEN SHIMMED. 3. AFTER THE BUILDING IS LEVEL, MORE BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING (SEE TABLE 3). 4. ANCHOR PLACEMENT IS ESTABLISHED BY THE WIDTH OF THE BUILDING. HOLES ARE DRILLED THRU THE 2"x4' BOTTOM PLATE WITH A 1/2" AUGER BIT. 1/2" EYEBOLT OR OPTIONAL 1/2" THREADED ROD (FOR A 'HIGH SET") IS SECURED THRU THE HOLE. 5. ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO FOOTER (GARAGE DOORS FOR EXAMPLE). HEADER DESIGN TRANSFERS THESE LOADS. B. IF THE UNIT HAS A FLOOR, EITHER A HOLE IS DUG FOR THE 30" AUGER ANCHOR AND BACKFILLED AND SECURED AS PER THE DETAIL OR A 1/2" HOLE IS DRILLED INTO THE CONCRETE 1-1/2" OFF OF RIM JOIST. THE EYEBOLT IS FASTENED THRU THE BOTTOM PLATE AND A SIMPSON A-24 (OR EQUAL) IS SECURED TO THE CONCRETE WITH A 1/2" WEDGE ANCHOR. 7. IF THE UNIT IS A 'NO FLOOR' OPTION, ANCHOR WITH 1/2"x5" WEDGE ANCHOR THRU THE 2"x4" BOTTOM PLATE. TABLE 1 ANCHORING TO CONCRETF TABLE 2 SKID RUNNER SPACING* SHED WIDTH UPLIFT (PLF) ANCHOR SPACING 20'-0" 400 3-e" 13'-8" 280 3-6" 11'-8" 240 S -C 1o'-0" 200 3'-e 8'-0" 160 3-0' 51' - 120 V -V -VALUES ME FROM END OF JOIST TO CENTERS OF (2) 4•x4• SKIDS ONLY. 13'-8' WADE SHEDS HAVE (4) SETS OF SKIDS. 7 30" AUGER ANCHOR (4,900LB) SETUP AND INSTALLATION OF DOUBLE WIDE SHED 1. BUILDING IS PLACED IN REQUESTED LOCATION. THE FIRST SECTION OF THE DOUBLE WIDE IS PLACED ON THE HIGHEST LOCATION OF GROUND AND IS LEVELED UP. 2. BLOCKS ARE THEN PLACED AT THE END, CENTER, AND OTHER END TO LEVEL ONCE THE BUILDING IS LEVEL, BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING (SEE TABLE 3). 3. THE NEXT SECTION OF THE SHED IS BACKED INTO PLACE AND UNLOADED PARALLEL WITH THE FIRST SECTION. THE TWO SECTIONS ARE CONNECTED AT THE LOWER CORNER WITH (1)j'x4j" BOLT AND NUT. THE SECOND SECTION IS THEN LEVELED AND THE OTHER BOLT HOLES ARE UNED UP AND BOLTED SECURE. THE REST OF THE BLOCKING IS THEN COMPLETED. THIS PROCEDURE IS REPEATED FOR MULTIPLE SECTION SHEDS UNTIL ALL SECTIONS ARE IN PLACE. 4. GROUND ANCHORS ARE THEN ADDED (SEE TABLE 4B). 5. ONCE THE BUILDING IS PROPERLY BLOCKED AND BOLTED TOGETHER, THE SUPPORT BRACING IS REMOVED. 6. ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO FOOTER (GARAGE DOORS FOR EXAMPLE). HEADER DESIGN TRANSFERS THESE LOADS. TABLE TABLE 2 SKID RUNNER SPACING* SHED WIDTH X1 X2 X3 13'-8" V-10)" V-16)" 1' -IO)" 11'-8" 2'-8" 6'-4' - 10'-0" V-7 6'-10" - 8'-0" 0'-9" 6'-6" - 6'-0" 0'-10" 51' - -VALUES ME FROM END OF JOIST TO CENTERS OF (2) 4•x4• SKIDS ONLY. 13'-8' WADE SHEDS HAVE (4) SETS OF SKIDS. 7 30" AUGER ANCHOR (4,900LB) SETUP AND INSTALLATION OF DOUBLE WIDE SHED 1. BUILDING IS PLACED IN REQUESTED LOCATION. THE FIRST SECTION OF THE DOUBLE WIDE IS PLACED ON THE HIGHEST LOCATION OF GROUND AND IS LEVELED UP. 2. BLOCKS ARE THEN PLACED AT THE END, CENTER, AND OTHER END TO LEVEL ONCE THE BUILDING IS LEVEL, BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING (SEE TABLE 3). 3. THE NEXT SECTION OF THE SHED IS BACKED INTO PLACE AND UNLOADED PARALLEL WITH THE FIRST SECTION. THE TWO SECTIONS ARE CONNECTED AT THE LOWER CORNER WITH (1)j'x4j" BOLT AND NUT. THE SECOND SECTION IS THEN LEVELED AND THE OTHER BOLT HOLES ARE UNED UP AND BOLTED SECURE. THE REST OF THE BLOCKING IS THEN COMPLETED. THIS PROCEDURE IS REPEATED FOR MULTIPLE SECTION SHEDS UNTIL ALL SECTIONS ARE IN PLACE. 4. GROUND ANCHORS ARE THEN ADDED (SEE TABLE 4B). 5. ONCE THE BUILDING IS PROPERLY BLOCKED AND BOLTED TOGETHER, THE SUPPORT BRACING IS REMOVED. 6. ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO FOOTER (GARAGE DOORS FOR EXAMPLE). HEADER DESIGN TRANSFERS THESE LOADS. TABLE 3 SHED DESCRIPTION FkD TYPES INTERIOR SPACING... TYPE PAD DIMENSIONS MAX. LOAD" MATERIAL I 2"x8"x16" 1778LBS CONCRETE BLOCK QUALITY END PAD SIDE RUNNER PAD TYPE CEMENT AND SAND MIX If 4'x8"x16" 3500LBS CONCRETE BLOCK QUALITY 6'-0" 1936LB CEMENT AND SAND MIX III 16'x16" 3950LBS ABS PLASNC PADS IV 8"x8'x16' 1900LBS CO CRETE BLOCK QUALITY 2558LB 1, II, III, OR IV CEMENT AND SAND MIX • BASED ON 20GOPSF SOIL BEARING CAPACW (2000PSF IS TYPICAL) OTE 1. HOLLOW OR SOLD CONCRETE BLOCKS (15%8•x18) MAY BE STACKED ON PMS FOR HIGH SER UP M 48• WITHOUT RBNFORCING. 2. ABS PADS REQUIRED ON IV -8' AND 13'-8' WIDE SHEDS ONLY. • LOAD WIDTH OF UPUFT ON RUNNER NOTES 1. PM SPACING IS END TO CENTER OF PAD. 2. PADS OTHER THAN END PADS SPACING 15 CENTER TO CENTER 3. USE SAME MAXIMUM SPACING FOR INTERIOR SPACING. GENERAL NOTES & SPECIFICATIONS FOR AUGER ANCHORS 1. BUILDING ANCHORS SHALL BE "MOBILE HOME" TYPE HP -1 SINGLE HELIX EYE AUGER ANCHOR BY HOME PRIDE OF BRISTOL, VA. OR EQUAL. AVERAGE HOLDING STRENGTH IS NOT LESS THAN 4,900 LBS, 2. ANCHORING SYSTEM TO GROUND PER LOCAL BUILDING CODE (BY DEALER). LOCATE ANCHORS PER TABLE 4A OR 4B. 3. THREADED ROD WITH EYEBOLTS SHALL BE PLACED THRU THE BOTTOM PLATE (FLOOR SYSTEM) AND ATTACHED TO ANCHOR. TABLE 3 SUPPORT FOOTING PAD SPACING FOR RUNNER BLOCKING FOR SINGLE & DOUBLE WIDE SHEDS SHED DESCRIPTION LW' PAD INTERIOR SPACING... MAXIMUM LOAD AND PAD TYPE SHED WIDTH TYPE LW-(PLF) END PAD MAX. SPACING END PAD SIDE RUNNER PAD TYPE INTERIOR PAD SIDE RUNNER PAD TYPE 13'-8" SW/DW ' 4.15/332 0' TO 6" 6'-0" 1936LB I, II, U. OR IV 1879LB I, IL III, OR IV 11'-8" SW/DW 6.00/480 0" TO 6" 6'-0' 2558LB 1, II, III, OR IV 2558LB I, II, III, OR N 10'-0" SW/DW 5.00/400 0' TO 6' 6'-0" 2400LB I, II, III, OR IV 2400LB I, II, III, OR IV 8'-0" SW 4.00/320 W TO 6' 6'-0' 2029LB I, II, III, OR IV 2133LO I, II, III, OR IV 6'-0' SW 3,00/240 0' TO C 6'-0' 1658LB I, 11, HE, OR IV 1866LO 1, If. III, OR N • LOAD WIDTH OF UPUFT ON RUNNER NOTES 1. PM SPACING IS END TO CENTER OF PAD. 2. PADS OTHER THAN END PADS SPACING 15 CENTER TO CENTER 3. USE SAME MAXIMUM SPACING FOR INTERIOR SPACING. GENERAL NOTES & SPECIFICATIONS FOR AUGER ANCHORS 1. BUILDING ANCHORS SHALL BE "MOBILE HOME" TYPE HP -1 SINGLE HELIX EYE AUGER ANCHOR BY HOME PRIDE OF BRISTOL, VA. OR EQUAL. AVERAGE HOLDING STRENGTH IS NOT LESS THAN 4,900 LBS, 2. ANCHORING SYSTEM TO GROUND PER LOCAL BUILDING CODE (BY DEALER). LOCATE ANCHORS PER TABLE 4A OR 4B. 3. THREADED ROD WITH EYEBOLTS SHALL BE PLACED THRU THE BOTTOM PLATE (FLOOR SYSTEM) AND ATTACHED TO ANCHOR. • LOM WIDTH OF UPLIFT ON RUNNER •• LOCATION FROM END WALL OF AUGER ANCHOR ••• MAXIMUM SPACING BETWEEN ANCHORS NOTES 1. ANCHOR SPACING IS DESIGNED AS PER ASCE-7. 2 ALL MEASUREMENTS ME CENTER -TO -CENTER 3. THE MINIMUM NUMBER OF ANCHORS PER SHED IS (4). (1) ANCHOR PER EACH CORNER, ADDITIONAL INFERIOR ANCHORS ME REWIRED IF SPACING IS MORE THAN 10'-0" BETWEEN ANCHORS - 4. ANCHORS SHALL BE ON SIDE WALLS EXCEPT WHEN THE SHOD IS PLACED NEXT TO AN MISTING BUILDING; IN WHICH ANCHORS CAN BE PLACED ON THE END WALLS AS CLOSE TO THE SIDE AS POSSIBLE TABLE 4A 30" AUGER ANCHOR SPACING - SINGLE WIDE SHED WIDTH LW' UPUFT (PLF) END ANCHOR-- MAX. INTERIOR SPACING... 13'-8" 7.00 243 0'-0" TO 3-0' 10'-0" 11'-8" 6.00 208 O-0' TO 3-0" 10'-0" 10'-0" 5.00 174 0'-0' TO 3-V 10'-0" 8'-0" 4.00 138 0'-0" TO 3-0" 10'-0" 670" 3.00 104 0'-0" TO 3-0' 10' -0 - FLOOR UYE LOAD THRU 2"x4' BOTTOM PLATE 1/2' WUPIER WA _: TABLE 30" AUGER ANCHOR SPACING B - DOUBLE WIDE SHED WIDTH LW" UPUFT (PLF) END ANCHOR-- MAX. INTERIOR SPACING... 20'-0" 10.00 400 0'-0" TO S -V 5'-0" • LOM WIDTH OF UPLIFT ON RUNNER •• LOCATION FROM END WALL OF AUGER ANCHOR ••• MAXIMUM SPACING BETWEEN ANCHORS NOTES 1. ANCHOR SPACING IS DESIGNED AS PER ASCE-7. 2 ALL MEASUREMENTS ME CENTER -TO -CENTER 3. THE MINIMUM NUMBER OF ANCHORS PER SHED IS (4). (1) ANCHOR PER EACH CORNER, ADDITIONAL INFERIOR ANCHORS ME REWIRED IF SPACING IS MORE THAN 10'-0" BETWEEN ANCHORS - 4. ANCHORS SHALL BE ON SIDE WALLS EXCEPT WHEN THE SHOD IS PLACED NEXT TO AN MISTING BUILDING; IN WHICH ANCHORS CAN BE PLACED ON THE END WALLS AS CLOSE TO THE SIDE AS POSSIBLE I CODE VERSION iS HII> OO, i2gery ASCE-) MINVFACfURER yypplpp glBq CONSRTUCRON TYPE T FIRE PROTECTION 2'x2' GALVANIZED WASHER FIRE SUPPRESSION SYSTEM NOW OcCuPANCY 2'x2' GALVANRFD WASHER AuaWARIE NUMBER OF SMRIR 1 WITH 1/2' NUT 1/z' THREADED ROD UPOSURE c WITH 1/2' NUT FNCLa30 INTERNAL PRESSURE COEFRCIENT +/- 0.14 OPTIONAL FOR 'HIGH SET' 1.15 NOTCH OR COUNTERSINK BOLT 1/2' THREADED ROTI OPTIONAL FOR 'HIGH SET' ROOF LNE LOAD xRs OR DORM EYES BOLTED TOGETHER WITH 1/2'x2' BOLT & NUT WITH (2)2•x2' GALVANIZED 7/2' CWPIFTt FLOOR UYE LOAD THRU 2"x4' BOTTOM PLATE 1/2' WUPIER WA _: WASHERS (2000L3 SHEAR CAPACIW) HURRICANE PROFECRON USAGE NO 2•x4' BOTTOM PULE NAILED TO 2"x B' P.T. BASE 1/2'x12' FORCED EYEBOLT SWINE FOOTODE ): , )( MIN. 1/2WEEDDG AN LB.J WNCRETE E CHOR INTO SLAB MIN. ° • . ° _ THRU 2•x4' P.T. BOTTOM PLATE• EYES BOLTED TOGETHER WITH 1/2'x2' TYPE I, II, III, PM (SEE TABLE I FOR SPACING) e------- "--- - - BOLT & NUT WITH (2)2•x2• GALVANIZED WASHERS (2.0001B SHEAR CAPACITY) y s OR N WITH BLOCKING AS REQUIRED SEE TABLE 3 ( )' 1/2•x3' (400 LBJ SIMPSON A-24 CONCRETE SLAB W OTHERS THROUGH WNCRETE SUB BY OTHERS THROUGH CONCRETE WEDGE ANCHOR CUP OR EQUAL LOCAL CODES AND JURISDICTION LOCA_ CODES AND JURISDICTION 30' EARTH AUGER ANCHOR (SEE TABLE 1 FOR SPACING) (SEE TABLE 4 FOR SPACING) SHED WITH SKID SHED WITH SKIDANCHORED SHED WITH FLOOR' OPTION TO PAD OR BLOCKING TO CONCRETE ANCHORED D TO CONCRETE TIE -DOWN DETAILS I CODE VERSION iS HII> OO, i2gery ASCE-) MINVFACfURER yypplpp glBq CONSRTUCRON TYPE V -B FIRE PROTECTION NON[ FIRE SUPPRESSION SYSTEM NOW OcCuPANCY SfORILE AuaWARIE NUMBER OF SMRIR 1 BASIC WIND SPEED y,.-16MgM1 UPOSURE c ENCLOSURE FNCLa30 INTERNAL PRESSURE COEFRCIENT +/- 0.14 IMPORTANCE FACTOR 1.15 ROOF DEAD LOAD 10FW ROOF LNE LOAD xRs OR DORM FLOOR DEAD LOAD 5,10, FLOOR UYE LOAD sM T(PSF - IIIEP3F OPT. R' RATNG OF WA . fL00K ROOF WA MGDULL9 PER BUILDING 1 HURRICANE PROFECRON USAGE NO XURRKINE SHELIFA USAGE NO SWINE FOOTODE LLb5 TVN T10 m.Ff. V) 0 W W 0 ►2 )N PUNS ME NOT PARI OF THIS AND ME GOVERNED BY LOCAL ION. DING IS EXEMPT FROM THE FBC :ONSERVATION WIDE PER SECTION DEFER TO TIE -DOWN DETAILS FOR PROPER RSTALATION REQUIREMENTS TO MEET CODE '< • _\CENSE • ��/i Q 'Ar - 0 r - O A g J al- Cn Z Sheet: STATE OF 7'� FCORIDI" S '• ...............•'•\_��0 \\\ i s!O NA I- �,\\\ Matthew T. Baldwin P.E. Florida Ucense 464608 AD -1 OF 1 2018-12-20 TOP LINE ENGINEERING APPROVAL PLAN #SS -B -180-C ALUMINUM ROOF SHEATHING FLOOR rR00P +27.8 -94.7 ACLS/DOORS ANDOWS +32.8/-29.2 ROOF FRAMING PLAN ELEVATION CROSS-SECTION TYPICAL AR 14 FRAM END ELEVATION WO GARAGE DOOR MY ON MD*" _Side Wall Header Schedule (180C"F.stenemvd End Wall HeadetC ule 1800 euilding Witlth Sizell Max. Span NFaster s wlo step S¢e (each end cFG-0" a -(e x 0.131' nails�yeavnl 94 x. a _".",. __us 4k4°w2k4' 8'-0" 7 8-3'x 0.731'nails NJ attack studs required to support each and. a. Tabulated Nelues are or No. 2 grade SpruceFinefir lumber. 11b. c. Laid flat b. NJ - Number ofjack studs required to support each end. d. No Jack studs but alb studs laid Iter c. Window header for window openings that halve more than 50% combined stud wall abote 11'-a• and below, otherwise use door header schedule. Date: J. Sea header details for attemete layouts, i.e. 2-2"x4" or 4"W" P.T. a. The header can be attached to the top I. 9F FASlF1:FA E06N£ ftRµypw IRMfMe. z sEE saRou¢ AIW11dl•L�nW. s' oeon plate and thus haw the combined strength n�aol�j, �sxk m001r000s°ftImllnnmsW'� 'e0w equivalent and use the maximum span stated. 0 s me z4 smos a 2,4 saE FLArE N/A VI N Odel u• oz MAx. FLaoR FRAIANs m TFL 0 I- O SS -B-1800 w 1x RUNNERS 0- I. Foulew Al F JNs µE Nar Fen or Txls qIN ¢I Aho N2 D m Sal£ I'IATE la W. o.oso• t''I J r/J:FINse el IINK .RI x�y z Ills euuUAE rs 011ir nKy rxE Fac 1141 Y OCNess AMN Far W/a-lo' � STANDARD WALL DETAI Nmc Mu FaA1 Iw buses ,wsµcaunaNumopusTrplw 1 m END WA TRUSS Fa- � 0 O 4. N= �D� • TMus95. M. ARE 2x4 l W. Ex�r As As Nalm. 2'x4• TRUSS O.C. N RIDGE Tata o.010• NoMN4 rl11LlNLas Two W Of e. ' ro fE lNsrNliD aN-s1rt an onlEas mw Lace �c-a• tax W 0 r. =NIX)" WNr wu D DOORS TO EEE WMu4 s Fh ref S ... L,_ As wo� sau FU �.� .... _ ...._ .......,._ _._._...._.- _ FLOOR rR00P +27.8 -94.7 ACLS/DOORS ANDOWS +32.8/-29.2 ROOF FRAMING PLAN ELEVATION CROSS-SECTION TYPICAL AR 14 FRAM END ELEVATION WO GARAGE DOOR MY ON MD*" _Side Wall Header Schedule (180C"F.stenemvd End Wall HeadetC ule 1800 euilding Witlth Sizell Max. Span NFaster s wlo step S¢e (each end cFG-0" a -(e x 0.131' nails�yeavnl 94 x. a _".",. __us 4k4°w2k4' 8'-0" 7 8-3'x 0.731'nails NJ attack studs required to support each and. a. Tabulated Nelues are or No. 2 grade SpruceFinefir lumber. 11b. c. Laid flat b. NJ - Number ofjack studs required to support each end. d. No Jack studs but alb studs laid Iter c. Window header for window openings that halve more than 50% combined stud wall abote 11'-a• and below, otherwise use door header schedule. Date: J. Sea header details for attemete layouts, i.e. 2-2"x4" or 4"W" P.T. a. The header can be attached to the top I. 9F FASlF1:FA E06N£ ftRµypw IRMfMe. z sEE saRou¢ AIW11dl•L�nW. s' oeon plate and thus haw the combined strength n�aol�j, �sxk m001r000s°ftImllnnmsW'� 'e0w equivalent and use the maximum span stated. 0 s me WA+L 214• wM cos FEIFa 12' MAX. 51DE &LIL WINDOWS DO RS G.F.I. I NOTES-OGmON E3F TR OUTLET -All WIRING SHALL BE B GAGE 3 -{'ARE MC CABLE. FI SOURCE N -ENCASE IN All METAL BOXES. L lr WIRING DIAGRAM (OPTIONAL) il� 2-W 4'M' 4"x4" W/2"x4" n 'M"�acwa ni.R'tE. N." III -09, ICC5185MO wPointeTear e lOnda34734 ac TYPE mON TYPE NUMBER OF SP® IMPORTANCE FACTOR J1.15 11 ROOF OFAD LOAD 101'9F ROOF LME ICAO aoFss OR 3WI6 PdM IaAO l..V.n. urc -u Ism. >aPss - 12OFS, mr. II 3 OF WALLS, FLOOR, FOR BUILDING PROTECTION USAGE SHELTER USWE son. w IEss NIST. YE 3alEdllE FNI saF 2 sMD raiz a1 aNOE � � i i ! Na xe kll7 Z Orden MTB 11'-a• Y -a' Date: � Z 12/12/17 DID w4L 0 s me z4 smos a 2,4 saE FLArE N/A VI N Odel u• oz MAx. FLaoR FRAIANs SS -B-1800 w MmEmm- 0- I. Foulew Al F JNs µE Nar Fen or Txls qIN ¢I Aho N2 D m Sal£ I'IATE la W. o.oso• t''I J r/J:FINse el IINK .RI x�y z Ills euuUAE rs 011ir nKy rxE Fac 1141 Y OCNess AMN Far W/a-lo' � STANDARD WALL DETAI Nmc Mu FaA1 Iw buses ,wsµcaunaNumopusTrplw a ala )ogCODE le ro IDosT�Foa FrmFw Nsrlu.•rmN ' �F11 F NNC WITH DOOR & WINDOW OPTIONS W�trrlNliars NtdnPAl .lR1� WI41 MrygpS AgA Fa- � 0 O 4. N= �D� • TMus95. M. ARE 2x4 l W. Ex�r As As Nalm. lEr a.W race, Nor CtlInNUgIa or O N Fs. ryg OR ESS ace, o stall BE ms. 11 CALVNX StFIl OF NT lE4 N F. lmccCnJW5 OAR 4W $P Fr. "u. mis M so• MWMuM Tata o.010• NoMN4 rl11LlNLas Two W Of e. ' ro fE lNsrNliD aN-s1rt an onlEas mw Lace �c-a• tax W 0 r. =NIX)" WNr wu D DOORS TO EEE WMu4 s Fh ref S ... L,_ As wo� sau FU �.� .... _ ...._ .......,._ _._._...._.- _ NIST. YE 3alEdllE FNI saF 2 sMD raiz xl Na xe IY-e' 1'-1r{' t' -id• P-IOj' 11'-a• Y -a' Yi• - a' -o• aw• Yom• - m M.rc�aW ®ssccIana`f4LVc M P.T. 24' a.a. TF, oFlpNAL 12OM' O 1a' o,C M. WIM 3/4'TW 0.reNR0 414' P,T. ARKNEo " H'N OR EWNkslrr. sEE n,aut 2 Fee aWNmY /No WAONG •L\CENSE . 0��� LLJ ) - 148r1" a Q_ pSTATE 0 1 IORIDP F ` O *11S / 0 N A L Q 0 Matthew T. Baldwin P.E. Z Florida License 64608 m Sheet: SSB -1 OF 1 _ �b� Manufactured Building Program 2601 Blair Stone Road dbpnerro~~~ ""��^=~ =^='' nu|nm �mhuaumuom�77o Phone:850.487.1824,Fax 851414.11436 Halsey Beshemrs, Secretary RmnDeSandm' Governor August o7, zn19 ' Alex Martens Superior Sheds, Inc. zoz3a.vo|usiaAve Orange City, FL32763 RE: Manufacturer Certification, ID MFT-113; Expiration Date: August 07, 2022 Dear Alex Martens ztismvpleasure ooinform you that Superior Sheds, Inc,located otz3asS.vn|us|aAve, Orange City, PL 32763, has been approved under the Manufactured Buildings Program, as provided for under Chapter 553, Part I, Florida Statutes, to manufacture Storage Sheds, Manufactured Buildings for installation inFlorida. Construction or modification on a manufactured building cannot begin until the Third Party Agency has approved the plans in accordance with the current Florida Building Code. Your Third Party Agency Js a contractor for the Department and has sta.tutory authority and responsibilities | that must be met to maintain approved status. You may expect and demand quality plans | review and inspections. Each Code change will make your plans obsolete until they have been reviewed, approved and indicated [on the cover page of the plans)for compliance with the Code by your Third Party / Agency for plans review. Please ensure that your plans are in compliance and are properly posted on our website.All site-related installation issues are subject to the local authority having jurisdiction. The Department's contractor will make unannounced monitoring visits atleast once each year, You must grant complete access tnyour manufacturing facility and records to remain in compliance with the rules and regulations ofthis program. Your certification is approv'ed for three years from this date.You will receive a renewal notice by Email generated bythe BUS ( for online renewal. zfyou have questions you may contact Robert Lorenzo at 850'717'1835 or our FAX at 850'414'8436. Please visit our website ut ww floridabuilding.org unsee valuable information vnthe Florida Manufactured Buildings Program,A copy of this letter must accompany applications for local ^ building| porm|ts. Sincerely, ^_V Robert Lorenzo Manufactured Buildings Program cc:TopLine Engineering, LLC ` �