Loading...
HomeMy WebLinkAboutEnergy Calcs FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: FY 445 SPEC Builder Name: SYNERGY HOMES,LLC. Street: 305 BAY STREET Permit Office: ST LUCIE COUNTY City,State,Zip: PORT ST LUCIE,FL,34952 Permit Number: Owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL,Fort Pierce County: St.Lucie(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types (1560.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a Concrete Block-Ext Insul, Exterior R=4.5 1392.00 ft2 b.Frame-Wood,Adjacent R=11.0 168.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (1597.0 sqft.) Insulation Area a Under Attic(Vented) R=30.0 1597.00 ft2 6. Conditioned floor area above grade(ft2) 1597 b.N/A R= ft2 c.N/A R= ft2 Conditioned floor area below grade(ft2) 0 R ft2 11.Ducts 7. Windows(124.0 sqft.) Description Area a Sup:Attic,Ret:Attic,AH:AHU CLST 6 140 a U-Factor: Sgl, U=0.30 124.00 ft2 SHGC: SHGC=0.29 b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a Central Unit 28.6 SEER:14.50 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a Electric Strip Heat 27.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0,290 14. Hot water systems a Electric Cap:50 gallons 8. Floor Types (1597.0 sqft.) Insulation Area EF:0.980 a Slab-On-Grade Edge Insulation R=0.0 1597.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits None Glass/Floor Area: 0.078 Total Proposed Modified Loads: 54.30 PASS Total Baseline Loads: 54.36 1 hereby certify that the plans and specifications covered by Review of the plans and -VTlE S74 this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. io PREPARED BY: Before construction is completed DATE: 4-23- this building will be inspected for 0 compliance with Section 553.908 ' ` I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. ��WL OWNER/AGENT eA BUILDING OFFICIAL: DATE: 4-23-7-07_e DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). 4/22/2020 11:23 AM EnergyGaugeO USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: FY 445 SPEC Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1597 Lot# Owner Name: Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: SYNERGY HOMES,LLC. Rotate Angle: 0 Street: 305 BAY STREET Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St.Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City,State,Zip: PORT ST LUCIE, Family Type: Single-family FL, 34952 New/Existing: New(From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1597 15288 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 M BATH 84 672 No 0 1 Yes Yes Yes 2 M W IC 72 576 No 0 1 Yes Yes Yes 3 MASTER BEDROO 264 2112 No 0 1 1 Yes Yes Yes 4 BEDROOM 3 149 1192 No 0 1 1 Yes Yes Yes 5 CLST 3 16 128 No 0 1 No Yes Yes 6 KITCHEN/DINING 378 4536 Yes 0 1 Yes Yes Yes 7 BATH 2 72 576 No 0 1 Yes Yes Yes 8 BEDROOM 2 144 1152 No 0 1 1 Yes Yes Yes 9 HALL 39 312 No 0 1 No Yes Yes 10 CLST 2 16 128 No 0 1 No Yes Yes 11 LAUNDRY 56 448 No 0 1 No Yes Yes 12 AHU CLST 9 72 No 0 1 No Yes Yes 13 GREAT ROOM 250 3000 No 0 1 Yes Yes Yes 14 FOYER 48 384 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulation M BATH 20 ft 0 84 ft2 ---- 1 0 0 2 Slab-On-Grade Edge Insulation M W IC 9 ft 0 72 ft2 ---- 1 0 0 3 Slab-On-Grade Edge Insulation MASTER BEDRO 29 ft 0 264 ft2 ---- 1 0 0 4 Slab-On-Grade Edge Insulation BEDROOM 3 11 ft 0 149 ft2 ---- 1 0 0 4/22/2020 11:23 AM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 5 Slab-On-Grade Edge Insulation CLST 3 1 ft 0 16 ft2 ---- 1 0 0 6 Slab-On-Grade Edge Insulation KITCHEN/DININ 26 ft 0 378 ft2 ---- 1 0 0 7 Slab-On-Grade Edge Insulation BATH 2 6 ft 0 72 ft2 ---- 1 0 0 8 Slab-On-Grade Edge Insulation BEDROOM 2 12 ft 0 144 ft2 ---- 1 0 0 9 Slab-On-Grade Edge Insulation HALL 1 ft 0 39 ft2 ---- 1 0 0 10SIab-On-Grade Edge Insulation CLST 2 1 ft 0 16 ft2 ---- 1 0 0 11Slab-On-Grade Edge Insulation LAUNDRY 1 ft 0 56 ft2 ---- 1 0 0 12SIab-On-Grade Edge Insulation AHU CLST 1 ft 0 9 ft2 ---- 1 0 0 13SIab-On-Grade Edge Insulation GREAT ROOM 28 ft 0 250 ft2 ---- 1 0 0 14SIab-On-Grade Edge Insulation FOYER 6 ft 0 48 ft2 ---- 1 0 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch v # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1683 ft2 0 ft2 Medium N 0.6 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 150 1597 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) M BATH 30 Blown 84 ft2 0.1 Wood 2 Under Attic(Vented) M W IC 30 Blown 72 ft2 0.1 Wood 3 Under Attic(Vented) MASTER BEDRO 30 Blown 264 ft2 0.1 Wood 4 Under Attic(Vented) BEDROOM 3 30 Blown 149 ft2 0.1 Wood 5 Under Attic(Vented) CLST 3 30 Blown 16 ft2 0.1 Wood 6 Under Attic(Vented) KITCHEN/DININ 30 Blown 378 ft2 0.1 Wood 7 Under Attic(Vented) BATH 2 30 Blown 72 ft2 0.1 Wood 8 Under Attic(Vented) BEDROOM 2 30 Blown 144 ft2 0.1 Wood 9 Under Attic(Vented) HALL 30 Blown 39 ft2 0.1 Wood 10 Under Attic(Vented) CLST 2 30 Blown 16 ft2 0.1 Wood 11 Under Attic(Vented) LAUNDRY 30 Blown 56 ft2 0.1 Wood 12 Under Attic(Vented) AHU CLST 30 Blown 9 ft2 0.1 Wood 13 Under Attic(Vented) GREAT ROOM 30 Blown 250 ft2 0.1 Wood 14 Under Attic(Vented) FOYER 30 Blown 48 ft2 0.1 Wood 4/22/2020 11:23 AM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below o 1 N Exterior Concrete Block-Ext Insul M BATH 4.5 6 0 8 0 48.0 ft2 0 0 0.6 0 2 E Exterior Concrete Block-Ext Insul M BATH 4.5 14 0 8 0 112.0 ft2 0 0 0.6 0 3 N Exterior Concrete Block-Ex[Insul M W IC 4.5 9 0 8 0 72.0 ft2 0 0 0.6 0 4 N Exterior Concrete Block-Ext InsiWIASTER BE 4.5 15 0 8 0 120.0 ft2 0 0 0.6 0 5 W Exterior Concrete Block-Ext InsLMASTER BE 4.5 14 0 8 0 112.0 ft2 0 0 0.6 0 6 E Exterior Concrete Block-Ext InstBEDROOM 3 4.5 11 0 8 0 88.0 ft2 0 0 0.6 0 7 N Exterior Concrete Block-Ext InsLKITCHEN/DI 4.5 11 0 12 0 132.0 ft2 0 0 0.6 0 8 W Exterior Concrete Block-Ext InsLKITCHEN/DI 4.5 15 0 12 0 180.0 ft2 0 0 0.6 0 9 E Exterior Concrete Block-Ext Insul BATH 2 4.5 6 0 8 0 48.0 ft2 0 0 0.6 0 10 E Exterior Concrete Block-Ext InstBEDROOM 2 4.5 12 0 8 0 96.0 ft2 0 0 0.6 0 11 S Garage Frame-Wood BEDROOM 2 11 12 0 8 0 96.0 ft2 0 0.1 0.6 0 12 S Garage Frame-Wood CLST 2 11 2 0 8 0 16.0 ft2 0 0.1 0.6 0 13 S Garage Frame-Wood LAUNDRY 11 7 0 8 0 56.0 ft2 0 0.1 0.6 0 14 S Exterior Concrete Block-Ext Ins6REAT ROO 4.5 14 0 12 0 168.0 ft2 0 0 0.6 0 15 W Exterior Concrete Block-Ext InstOREAT ROO 4.5 14 0 12 0 168.0 ft2 0 0 0.6 0 16 S Exterior Concrete Block-Ext Insul FOYER 4.5 6 0 8 0 48.0 ft2 0 0 0.6 0 DOORS # Ornt Door Type Space Storms U-Value W idth Height Area Ft In Ft In 1 S Insulated FOYER None .39 3 6 8 20 ft2 WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang v # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 4 Vinyl Low-E Single Yes 0.3 0.29 N 9.0 ft2 1 ft 0 in 1 ft 4 in None None 2 W 5 Vinyl Low-E Single Yes 0.3 0.29 N 15.0 ft2 1 ft 0 in 1 ft 4 in None None 3 E 6 Vinyl Low-E Single Yes 0.3 0.29 N 15.0 ft2 1 ft 0 in 1 ft 4 in None None 4 N 7 Vinyl Low-E Single Yes 0.3 0.29 N 40.0 ft2 1 ft 0 in 1 ft 4 in None None 5 W 8 Vinyl Low-E Single Yes 0.3 0.29 N 15.0 ft2 1 ft 0 in 1 ft 4 in None None 6 E 10 Vinyl Low-E Single Yes 0.3 0.29 N 15.0 ft2 1 ft 0 in 1 ft 4 in None None 7 S 14 Vinyl Low-E Single Yes 0.3 0.29 N 15.0 ft2 1 ft 0 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 441 ft2 441 ft2 21 ft 8 ft 11 4/22/2020 11:23 AM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000426 1783.6 97.92 184.15 .1585 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 14.5 28.6 kBtu/hr 858 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ftz DUCTS ----Supply---- ----Return---- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 140 ftz Attic 14 ft2 Default Leakage AHU CLST (Default)c(Default)c 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: CoolingJan Feb ]Mar Apr May rl Jun Jul Augri Se Oct Nov Dec Heatin Jan �Xj Feb lX]Mar f Apr f May Jun �xl Jul �xl AuSep Oct Nov X Dec Ventin Jan [ ]Feb XMar [X]A r [ Ma Jun Jul Aug Se [ Oct [X Nov [ Dec 4/22/2020 11:23 AM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(W D) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling(W EH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating(W D) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(W EH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 M BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 M W IC Default(8 Ibs/sq.ft. ft2 ft 0.3 MASTER BEDROO Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 3 Default(8lbs/sq.ft. ft2 ft 0.3 KITCHEN/DINING Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 HALL Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8 Ibs/sq.ft. ft2 ft 0.3 AHU CLST Default(8 Ibs/sq.ft. ft2 ft 0.3 GREAT ROOM Default(8lbs/s .ft. ft2 ft 0.3 FOYER 4/22/2020 11:23 AM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 6 of 6 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New(From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple-family 2. Single-family b) Return ducts R 6.0 c) AHU location AHU CLST 3. No. of units(if multiple-family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 28.6 a) Split system SEER 14.5 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area(sq.ft.) 6. 1597 d) Room unit/PTAC EER e) Other 7. Windows,type and area a) U-f actor:(weighted average) 7a. 0.300 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.290 14. Heating system: Capacity 27.0 c) Area 7c. 124.0 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-f actor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient(SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab-on-grade(R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.98 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame(Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry(Insulation R-value) 10A2. 4.5 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame(Insulation R-value) 10131. 11.0 2. Masonry(Insulation R-value) 1062. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit f) Programmable thermostat No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: gtjr 'O-. Date: Address of New Home: 305 BAY STREET City/FL Zip: PORT ST LUCIE, FL 34952 4/22/2020 11:23:49 AM EnergyGauge@ USA 6.0.04(Rev. 1)-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 This document was created with Win2PDF available at http://www.win2pdf.com. The unregistered version of Win2PDF is for evaluation or non-commercial use only. This page will not be added after purchasing Win2PDF.